• Title/Summary/Keyword: Optometry

Search Result 582, Processing Time 0.024 seconds

A Study of Research on Uncorrected Refractive Error in Elementary School Children in Mokpo (목포지역 초등학생들의 미교정안 현황에 관한 연구)

  • Kim, In Suk;Jang, Jung Un
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.313-317
    • /
    • 2011
  • Purpose: This study was to assess prevalence of refractive errors and uncorrected refractive errors in elementary school children in Mokpo and uncorrected refractive errors were to be used as the basic data. Methods: Vision tests were conducted on 400 subjects of 1st~6th grades at 3 elementary schools in Mokpo city, and subjective, objective refraction test were also performed to survey uncorrected refractive errors. Results: The prevalence of myopia was 256, 64% of total subjects, Hyperopia was 21, 5.3%, astigmatism was 19, 4.8%. The prevalence of uncorrected refractive errors were increased as higher grade and more oculus dexter higher than oculus sinister. Conclusions: Vision impairment which need an accurate vision correction for elementary school students requires the regular examination and actively correction in order to protect the elementary school students for basic welfare.

Assessment of Reproducibility and Repeatability for Color Vision Test (색각검사법의 재현성 및 반복성평가)

  • Joo, Seok-Hee;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.109-114
    • /
    • 2008
  • Purpose: To assess the reproducibility and repeatability for each color vision test method. Methods: The subjects for color vision test were 30 students without congenital color vision deficiency and they major in optometry in a university, Korea. The type of color vision test selected for this study were Hans color vision test, Hans 15 hue test and Lanthony D 15 hue test. The Ishihara test was added for assessment of reliability of inter-tester. Results: All of the subjects were classified into normal at pseudoisochromatic plates, but one subject's result showed mild blue-yellow color deficiency at Hue discrimination. Results of 3 repeated test for subjects and inter-tester examination showed no errors at pseudoisochromatic plates. There were differences in mild errors among repeated test at Hue discrimination, but no differences were found in the results of repeated test to classify color vision deficiency. Conclusion: Each tester had better be more skilled to test even simple color vision test for eliminating the possibility of mild errors. Each subject might just as well be careful in color vision test. It is required to test both method of pseudoisochromatic plates and Hue discrimination in screening test.

  • PDF

Analysis of Induced Heterophoria Variations by Repeated Binocular Vision Examinations (반복된 양안시 검사로 유발된 사위도 변화 분석)

  • Leem, Hyun-Sung;Lee, Eun-Hee;Song, Yun-Young;Jung, Mi-A
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.281-286
    • /
    • 2018
  • The purpose of this study was to evaluate the degree of heterophoria variations according to visual fatigue induced by increasing number of examinations while repeating binocular vision examinations. Twenty - one adults in their twenties who had no heterotropia other eye disease or systemic disease underwent binocular vision examinations. As the examinations progressed, the degree of heterophoria increased in both orthophoria and heterophoria. When the distance examinations was repeated 5 times, orthophoria increased degree of $1.56{\Delta}$ heterophoria. and heterophoria increased degree of $1.63{\Delta}$ heterophoria. When the near examinations was repeated 5 times, orthophoria increased degree of $1.78{\Delta}$ heterophoria. and heterophoria increased degree of $2{\Delta}$ heterophoria.. As the number of examinations increased, the result gradually deviated from the normal range as visual fatigue increased. The degree of the variation is judged to be enough to make the wrong prescription in the clinic. In conclusion, it was found that the binocular vision examinations should be conducted more accurately and promptly.

Thirteen-week repeated-dose oral toxicity study of KOB03, a polyherbal medicine for allergic rhinitis, in rats (알러지성 비염 한약제제 KOB의 랫드에서의 13주 반복 경구투여에 의한 독성 연구)

  • Kang, Seok Yong;Park, Yeong-Chul;Park, Yong-Ki
    • The Korea Journal of Herbology
    • /
    • v.28 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • Objectives : To evaluate the safety of KOB, a polyherbal medicine for allergic rhinitis, we conducted a subchronic toxicology study. Methods : Dried extract of KOB(Lot. No. 11003, yield : 41.1%) was prepared from GLP company (Hanpoong Pharm & Food Co., Ltd). KOB was repeatedly administrated orally of male SD rats at daily dose levels of 500 (G2), 1250 (G3) and 5000 (G4) mg/kg/day for 13 weeks. We recorded the clinical signs of toxicity, body weight, food intake/consumption, optometry, urine analysis, organ weights, hematology, and conducted serum biochemical analysis, necropsy, gross and histological changes in target organs of Sprague-Dawley rats, and clinical chemistry analysis. Results : Neither death nor any toxicological signs were obserbed in KOB at all doses of 500, 1250 and 5000 mg/kg/day during the administration period for thirteen-week. Furthermore, there was no difference in body weight and food-take consumption, optometry, necropsy, organ weight, gross pathological findings, and urine analysis among the groups of rats treated with different doses of KOB, during at the observation period for thirteen-week. The hematological analysis and clinical blood chemistry data were revealed no toxic effects from repeated-dose administration of KOB in rats during the observation period. Conclusions : Based on these results, the no observable adverse effect level (NOAEL) of KOB was considered to be 5000 mg/kg/day for male rats under these study conditions.

Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth of 20 to 24 Years old population in Korea (한국인 20세부터 24세까지의 중심 각막 두께, 앞방 부피, 앞방 깊이에 대한 상관관계 분석)

  • Sang Yeul Park;Douk Hoon Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.12 no.1
    • /
    • pp.1654-1659
    • /
    • 2024
  • Purpose: The aim of this study was to determine Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth in Koreans aged 20 to 24 years using the Pentacam tool. Methods: The subjects of this study were 53 Korean adults with healthy eyes. The central corneal thickness(CCT), anterior chamber volume(ACV), and anterior chamber depth(ACD) was measured with Pentacam device. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 22.0±2.01 years. The mean +/- central corneal thickness of the right eye and left eye were 546.66±32.221mmg and 545.70±32.759mm, respectively. Also The mean central cornea thickness was 546.19 um in the whole sample. The mean anterior chamber volume the right eye and left eye was 181.66±33.738 mm3 and 180.12±30.84 mm3, respectively. The mean anterior chamber depth was 3.158±0.257 mm and 3.122±0.233 mm in right eye and left eye, respectively. There was a statistically significant difference between anterior camber volume and anterior chamber depth(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and anterior chamber volume. Also there was no statistically significant difference between central cornea thickness and anterior chamber depth. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adolescents.

The Deposition of Tear Protein according to Soft Lens Materials and The Cleaning Efficacy of Multi-purpose Solution according to the Surfactant Types (소프트렌즈 재질 별 누액단백질 침착 및 계면활성제 종류에 따른 다목적용액의 세척효율)

  • Park, Mijung;Kwon, Young Dae;Lee, Wang Jae;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.179-188
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the cleaning efficacy of multi-purpose solutions containing different types and content of surfactants and their effect on the visible light transmittance of soft lens. Methods: Soft lenses made of different materials (etafilcon A and hilafilcon B) were deposited tear proteins by using the artificial tear and then compared the resulting cleaning efficacy and visible light transmittance after cleaning the lens with 6 types of multi-purpose solutions containing different content of surfactants. Results: The cleaning efficacy of multi-purpose solutions was variously shown as approximately 23~43% according to the active concentration of surfactants and surface tension in multi-purpose solution when etafilcon A lens cleaned with rubbing. The highest cleaning efficacy was detected when cleaned with the multi-purpose solution containing hydrogen peroxide besides surfactant however, the amount of remaining protein was still high on the lens. After washed with multi-purpose solution, the visible light transmittance of lens was in 89.8 to 90.8%. The amount of protein deposited on hilafilcon B lens was very small compared with it on etafilcon A lens even though it was incubated in artificial tears for 7 days, which showed 5~10% of protein amount in etafilcon A lens and the decrease of visible light transmittance was also not significant. In case of rubbing with multi-purpose solution, the cleaning efficacy on hilafilcon B lens was in 45.4 to 67.4% however, the order of cleaning efficacy of multi-purpose solution was different from it on etafilcon A lens. The visible light transmittance of hilafilcon B lens has been restored to the level of new lens. Conclusions: From the result, it is concluded that the appropriate multi-purpose solution should be selected according to the lens material and the amount of protein deposit on the basis of understanding surfactants and active principle for proper care of protein deposit on soft lens and the cleaning with rubbing is more efficient for lens care regardless of manufacturer's guideline.

The Change in Refractive Powers of Soft Contact Lenses Caused by the Deposition of Tear Proteins (누액 단백질 침착에 의한 소프트콘택트렌즈의 굴절력 변화)

  • Choi, Jin-Yong;Park, Jae-Sung;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.383-390
    • /
    • 2011
  • Purpose: The present study was conducted to investigate whether refractive powers of soft contact lenses were induced by the deposition of tear proteins when wearing soft contact lenses. Methods: The soft contact lenses (material: etafilcon A, hilafilcon A and comfilcon A) with refractive powers of -1.00 D, -3.00 D, -5.00 D and -7.00 D were incubated in artificial tear for 1 day, 3 days, 5 days, 7 days and 14 days, respectively. After incubation, their refractive powers were measured by wet cell method with an auto-lens meter and their protein deposited on the lenses was determined by the method of Lowry. Results: Among three types of soft contact lenses, the most protein deposition was detected in ionic etafilcon A lens material and significant change of its refractive power was manifested. In other words, refractive powers of etafilcon A lenses firstly decreased after 1 day incubation in artificial tear and then gradually increased with increasing incubation period again. The observed change in refractive powers of all diopters of etafilcon A material was beyond the scope of standard error and bigger in the lens with lower optical power. On the other hand, non-ionic hilafilcon A showed less protein deposition as much as about 20% in etafilacon A and statistically significant increase of refractive powers with increasing incubation period in artificial tear. The change in refractive power of hilafilcon A was also beyond the scope of the standard of error when incubating in artificial tear and greater in the lens with lower diopter. The least protein deposit was shown in silicone hydrogel lens material, comfilcon A as approximately 10% of it in etafilcon A, indicating less change in refractive power within the standard range of error. Conclusions: The large change of refractive powers that was beyond the scope of standard error by the deposition of tear proteins on soft contact lenses was differently detected depending on lens materials in the current study. Thus, the deposition of tear proteins induced by longer period of lens wearing may be one of the causes that induces blurred vision, suggesting that soft contact lens wearers with the amount of tear proteins may need to choose proper lens material.

The Contamination Level of Lens Cases by Various Wearing and Storage Periods of Soft Contact Lens and the Actual Condition of Lens Cases Care (소프트 콘택트렌즈 착용 기간과 보관 기간에 따른 보관 용기의 오염도 및 보관 용기 관리 실태)

  • Kim, So Ra;Shin, Sang Mok;Park, Jong Ae;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.135-145
    • /
    • 2011
  • Purpose: This study was conducted to investigate the actual condition of caring soft contact lens cases and the change in contamination level of lens cases by wearing and storage period of soft contact lens. Methods: The actual condition of caring soft lens cases was surveyed with sixty-three of contact lens wearers. Soft contact lenses were worn for 1, 3, 7 and 14 days, and the lenses were separately stored in 12 lens cases for 1, 3 and 7 days. The contamination level of lens cases was determined by counting the numbers of microorganisms, gram negative bacteria and fungi. Results: Only 14% of survey answerers cleaned their lens cases with a brush, rinsed and dried them upside down before next usage of lens case when those lenses were kept for a long time. Furthermore, 54% of total answerers just kept soft contact lens in the case without changing the multipurpose solution. Microorganisms, gram negative bacteria and fungi were detected in lens cases even when soft contact lens were kept for 1 day in the lens case after wearing for 1 day and cleaning it with multipurpose solution. The numbers of microorganisms, gram negative bacteria and fungi in lens cases increased with storage periods of soft contact lens, and also contamination level of lens cases was increased in accordance with wearing period of lens. In the lens cases without changing multipurpose solution, the numbers of microorganisms, gram negative bacteria and fungi increased with storage period of lens with statistical significance. Conclusions: This study showed that lens wearers' concerns on caring contact lens case were not satisfactory. As the result, the contamination of lens cases was related to increase of lens wearing and storage periods suggesting that the proper instruction and education for lens wearers are required.

A Comparison of the Movement of Aspheric RGP Lens on Cornea by the Amounts of Keratometric Astigmatisms using Keratometer and Corneal Topography (각막곡률계와 각막지형도를 이용한 각막난시 측정값에 따른 비구면 RGP 렌즈의 각막에서 동적움직임 비교)

  • Park, Sang-Il;Lee, Se Eun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.123-133
    • /
    • 2011
  • Purpose: The present study was conducted to analyze any difference in the movement of aspheric RGP lens by the amounts of keratometiric astigmatisms using keratometer and corneal topography. Methods: Corneal curvatures in thirty six eyes of males and females of with-the-rule keratometric astigmatisms in their twenties were measured by a keratometer and worn aspheric RGP lenses. Then, lens rotations, vertical and horizontal movements of lens by blinking were measured to compare with lens movements when aspheric RGP lenses were fitted by total keratometric astigmatisms using corneal topography. Results: The case having higher amount of central keratometric astigmatism was 61.1% of subjects, however, 36.1% of subjects showed higher total keratometric astigmatism indicating that central keratometric astigmatism was not always bigger than total keratometric astigmatism. Since over 0.25 diopter difference between total and central keratometric astigmatisms was shown in 19 eyes (52.8% of subjects), the prescription for lens fitting could be changed. Significant difference in horizontal movement was detected with increase of astigmatism when it compared based on the amount of keratometric astigmatism measured by a keratometer. However, there was no significant difference in lens rotation, horizontal and vertical movements by comparison with the amount of total keratometric astigmatism using a corneal topography. When central keratometric astigmatism measured by keratometer was bigger than total keratometric astigmatism estimated by corneal topography, bigger lens rotation was shown compared with opposite case. Also, the tendency of bigger lens rotation was measured with the increase of keratomatric astigmatism in the case of same prescription having same base curves with same amount of keratometric astigmatism but different curvatures. Conclusions: From the present study, we concluded that lens movements on cornea were not totally different when aspheric RGP lens fitted on with-the-rule astigmatism by keratometer and corneal topography. However, there was some difference in certain lens movements. Therefore, we concluded that further study on the relationship between the prescriptions for lens fitting should be conducted for improving the rate of successful lens fitting by keratometer or for the proper application of corneal topography for lens fitting.

Validating a New Approach to Quantify Posterior Corneal Curvature in Vivo (각막 후면 지형 측정을 위한 새로운 방법의 신뢰도 분석 및 평가)

  • Yoon, Jeong Ho;Avudainayagam, Kodikullam;Avudainayagam, Chitralekha;Swarbrick, Helen A.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.223-232
    • /
    • 2012
  • Purpose: Validating a new research method to determine posterior corneal curvature and asphericity(Q) in vivo, based on measurements of anterior corneal topography and corneal thickness. Methods: Anterior corneal topographic data, derived from the Medmont E300 corneal topographer, and total corneal thickness data measured along the horizontal corneal meridian using the Holden-Payor optical pachometer, were used to calculate the anterior and posterior corneal apical radii of curvature and Q. To calculate accurate total corneal thickness the local radius of anterior corneal curvature, and an exact solution for the relationship between real and apparent thickness were taken into consideration. This method differs from previous approach. An elliptical curve for anterior and posterior cornea were calculated by using best fit algorism of the anterior corneal topographic data and derived coordinates of the posterior cornea respectively. For validation of the calculations of the posterior corneal topography, ten polymethyl methacrylate (PMMA) lenses and right eyes of five adult subjects were examined. Results: The mean absolute accuracy (${\pm}$standard deviation(SD)) of calculated posterior apical radius and Q of ten PMMA lenses was $0.053{\pm}0.044mm$ (95% confidence interval (CI) -0.033 to 0.139), and $0.10{\pm}0.10$ (95% CI -0.10 to 0.31) respectively. The mean absolute repeatability coefficient (${\pm}SD$) of the calculated posterior apical radius and Q of five human eyes was $0.07{\pm}0.06mm$ (95% CI -0.05 to 0.19) and $0.09{\pm}0.07$ (95% CI -0.05 to 0.23), respectively. Conclusions: The result shows that acceptable accuracy in calculations of posterior apical radius and Q was achieved. This new method shows promise for application to the living human cornea.