• Title/Summary/Keyword: Optometry

Search Result 582, Processing Time 0.023 seconds

Comparison of Contrast Sensitivity at Near Between Functional Progressive Addition Lenses and Sigle Vision Lenses (기능성 누진가입도렌즈와 단초점렌즈의 근거리 대비감도 비교)

  • Kim, Chang-Jin;Kim, Hyun Jung;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.381-388
    • /
    • 2010
  • Purpose: This study was to compare the contrast sensitivity evaluated the visual ability at near wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition for 2 months. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses(EYE-T, Chemilens Co., Korea, ADD 0.75D) for 2 months. Corrected visual acuity at distance and near and contrast sensitivity at near were tested right after wearing functional progressive addition lenses to compare wearing single vision lenses. And we had second test after 2 months later. Results: Comparing between test and retest, contrast sensitivity at near wearing functional progressive addition lenses was improved more than wearing single vision lenses at all spatial frequency of right, left and both eyes. Conclusions: There was considered that contrast sensitivity test is useful to evaluate the visual ability as well as quality of near work and can be applied variously.

Changes in Corneal and Internal Astigmatism with Age (연령에 따른 각막난시와 내부난시의 변화)

  • Lee, Hyun;Kim, Jung-Hyun;Lee, Sung-Bok;Eom, Jeong-Hee;Rhee, Kang-Oh;Lee, Tae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.3933-3940
    • /
    • 2013
  • The purpose of present study was to determine the frequency of RA with age and to investigate the age-related trends and changing-factors in RA, CA and IAs. The refractive power of the eye and the power of corneal anterior surface were measured with auto-refractor among 1,017 inhabitants aged 5 to 59 years in Cheongju in July 2010. The overall frequency of RA was 22.7%, and frequency of RA increased from 8.9% in 5~9 years age group to 36.8% in 20~29 years age group. It then dipped to 19.2% in 40~49 years age group but increased again 28.6% in 50~59 years age group. $J_{45}$ components for RA, CA, and IAs were fairly stable in different age groups, the changes in $J_0$ components for both RA and CA appeared to be decreased after age of 30 years. In addition, the refractive power on the vertical direction was changed slightly with age, but the refractive power on the horizontal direction was changed significantly with age. It was expected that the change in the frequency of astigmatism with age was due to the change in the refractive power of horizontal meridian.

Comparisons of Adherence Level of Micro-organisms According to Contact Lens Materials and Protein Deposition and Disinfection Efficacy of Multipurpose Solution (콘택트렌즈 재질 및 침착 단백질에 따른 균 흡착 정도와 다목적용액의 살균력 비교)

  • Sung, Hyung Kyung;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.35-42
    • /
    • 2015
  • Purpose: The present study was aimed to compare the difference in adherence level of microorganisms according to contact lens materials and protein deposition and to evaluate disinfection efficacy of multipurpose solution. Methods: The evaluations of micro-organisms' adherence and disinfection efficacy of multi-purpose solution were conducted by employing the Part 2. Regimen Procedure for Disinfecting Regiments in the Disinfection Efficacy Testing under the "FDA Evaluation Criteria & Method". Results: Pseudomonas aeruginosa, Serratia marcescens, Candida albicans except Staphylococcus aureus adhered more on etafilcon A lens and disinfection efficacy of total 4 products investigated was almost perfect except Candida albicans. The 3 micro-organisms except Serratia marcescens adhered more to albumin-predeposited lens. Disinfection efficacy of multi-purpose solution was higher against the micro-organisms adhered to albumin-deposited lens than against the micro-organisms adhered to the lysozyme-deposited lens. Furthermore, disinfection efficacy of multi-purpose solution was different according to types of micro-organisms. Conclusions: It was revealed that the type of micro-organisms, the lens materials and type of absorbed tear protein affected the amount of adhered micro-organisms to contact lens and that adhesion of tear protein could induce the change of disinfection efficacy of multi-purpose solution. It suggest that the hygienic condition of contact lens can vary by these factors influencing on disinfection efficacy and the occurrence of adverse effect can be affected.

The Evaluation of Visual Quality by Employing Double-pass Principle in Circle Contact Lens Wearers after Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용시 double-pass 원리를 이용한 시력의 질 평가)

  • Kwon, Ki Nam;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.277-284
    • /
    • 2015
  • Purpose: The study aimed to evaluate the effect of circle contact lens wearing on visual quality of the eyes after a refractive surgery. Methods: The objective visual quality was evaluated for 40 eyes who did not get refractive surgery and 30 eyes who got a refractive surgery after applying plano circle contact lenses on their eyes, respectively. Modulation transfer function (MTF), objective scatter index (OSI) and the focusing ratio on retina (Strehl ratio) were measured by using optical quality analysis system (OQAS) and the correlation between pupil size and objective visual quality was analyzed by measuring the pupil size. Results: When wearing circle contact lens on the eyes after refractive surgery, MTF and Strehl ratio were reduced and OSI was increased compared with the eyes without refractive surgery. The eyes after a refractive surgery showed more significant difference changes in MTF, OSI and Strehl ratio according to the pupil size compared with those without refractive surgery. Conclusions: The results showed that wearing of circle contact lens after the refractive surgery has deteriorated the objective visual quality based on the quality of focused image on the retina. Therefore, we suggest that sufficient understanding and consideration about the deterioration of visual quality is necessary in the case of circle contact lens wearing after refractive surgery.

Relationship between Reading Speed and Blinking Rate according to Longitudinal Chromatic Aberration during Book Reading (종이책 독서 시 종색수차에 따른 읽기속도와 순목횟수의 상관관계)

  • Kim, Se-il;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.369-375
    • /
    • 2015
  • Purpose: The current study was performed to estimate the changes in reading speed and blinking rate according to different background colors when reading paper book and further investigate their correlation. Methods: Twenty-nine adults (10 males, 19 females) who consented to the present study and had no ocular disease, ocular surgery history showing normal binocular vision were participated into the study. The subjects were asked to read the novels with black letter printed on white, red, green and blue background for 15 min, respectively. Then, the reading speed per page and blinking rate per page were measured during reading and analyzed according to background colors. Results: Reading speed per page according to the background color showed a tendency to accelerate in the white and green background as the reading time increased however, it was almost unchanged in the blue background and rather decelerated in the red background. On the other hand, the blinking rate per page tended to decrease in all background as the reading time was increased however, the smallest reduction was shown in the red background. There was a correlation that the reading speed increased as the blinking rate decreased in all backgrounds and the best correlation was shown in the green background. Conclusions: From the results, a correlation between the increasing reading speed and the reducing blinking rate while reading paper book with same demand on accommodation and convergence was confirmed however, the change in blinking rate and reading speed was varied depending on the main wavelength of light. It might mean that the working speed and visual fatigue can be varied depending on the difference of main wavelength when doing near work. Thus, it can be suggested that the adjustment of working environment and conditions should be made according to the kind of required perception.

Relationship between the Deposition of Tear Constituents and the Adherence of Candida albicans according to Soft Contact Lens Materials and Pigmentation (소프트콘택트렌즈 재질과 착색에 따른 눈물성분 침착과 칸디다균 흡착의 상관관계)

  • Park, So Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.215-225
    • /
    • 2016
  • Purpose: The aim of this study was to figure out how the characteristics of soft contact lens materials and pigmentation affect the adherence of C. albicans on soft contact lenses pre-deposited with tear constituents. Methods: The adherent number of C. albicans on clear soft contact lenses (hereinafter clear lenses) and circle soft contact lenses (hereinafter circle lenses) made of etafilcon A, hilaiflcon B and nelfilcon A, respectively, was measured before and after the deposition of artificial tear. Also, bacteria adherence on lenses were observed by a scanning electron microscope. Results: Adherence of C. albicans was significantly different according to lens materials. The amount of adsorption was not different between clear lenses and circle lenses made of etafilcon A however, the number of bacteria absorption was bigger in hilafilcon B and nelfilcon A lenses. More absorption of C. albicans was found in the non-pigmented central area compared the pigmented area, and non-pigmented peripheral area has more bacterial absorption than non-pigmented central area. The number of C. albicans decreased in the case that tear protein was pre-deposited. The maintenance of antibacterial activity against C. albicans was different according to lens materials thus, etafilcon A has the longest period of its maintenance. Conclusions: It was revealed that the number of C. albicans was different according to the characteristics of lens materials, pigmentation or non-pigmentation, the pigmented area of soft contact lenses. Thus, it is suggested that the management method should be different according to the adsorption characteristics of C. albicans.

Evaluation of Reliability for Combined Refractive Power of Lenses in an Automatic Phoropter (자동포롭터 내부렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2015
  • Purpose: To evaluate the reliability of refractive power by comparing the marked refractive power in an automatic phoropter and actually measured spherical/cylindrical refractive power. Methods: Actual refractive power of minus spherical lens and cylindrical lens in an automatic phoropter was measured by a manual lensmeter and compared with the accuracy of marked refractive power. Furthermore, combined refractive power and spherical equivalent refractive power of two overlapped lenses were compared and evaluated with the refractive power of trial lens. Results: An error of 0.125 D and more against the marked degree was observed in 70.6% of spherical refractive power of spherical lens which is built in phoropter, and the higher error was shown with increasing refractive power. Single cylindrical refractive power of cylindrical lens is almost equivalent to the marked degree. Combined spherical refractive power was equivalent to spherical refractive power of single lens when spherical lens and cylindrical lens were overlapped in a phoropter. Thus, there was no change in spherical refractive power by lens overlapping. However, there was a great difference, which suggest the effect induced by overlapping between cylindrical refractive power and the marked degree when spherical lens and cylindrical lens were overlapped. Spherical equivalent refractive power measured by using a phoropter was lower than that estimated by trial glasses frame and marked degree. The difference was bigger with higher refractive power. Conclusions: When assessment of visual acuity is made by using an automatic phoropter for high myopes or myopic astigmatism, some difference against the marked degree may be produced and they may be overcorrected which suggests that improvement is required.

Individual Difference in the Decrease of Visual Acuity and the Change in Contrast Threshold According to the Level of Optically Induced Retinal Defocus (광학적으로 유발된 망막흐림의 정도에 따른 시력감소의 개인차와 인식 대비도의 변화)

  • Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.93-98
    • /
    • 2014
  • Purpose: We were aim to investigate individual difference of visual acuity (VA) decrease and the change of contrast threshold (CT) according to the level of optically induced retinal defocus. Methods: A total of 69 eyes were examined using consist of ten-graded decimal vision chart (Landolt's ring). After conducted full correction of subject's refractive error, a monocular VA and CT were measured according to sequential increase by 0.25 D each time. Results: VA gradually decreased according to the increase of retinal defocus level. Individual difference of VA decrease was range from 1.2 to 0.6 in retinal defocus induced by +0.25 D. When retinal defocus was induced as much as +0.50 D and +0.75 D, it was in the range of 1.0 to 0.3 and 0.9 to 0.1 respectively. With +1.00 D, some participants didn't even recognize the 0.1 in the chart. With +1.75 D, whole participant did not recognize the 0.1. Also, CT was gradually decreased with increase of the retinal defocus level. Conclusions: Examiners should consider individual difference in the decrease of VA according to the level of residual refractive error when determining final prescription of a patient.

Comparison on Accommodative Response Changes in the Normal Group and Convergence Insufficiency (정상군과 폭주부족군에서 조절반응 변화량의 비교)

  • Kwak, Ho-Weon;Lee, Se-Hee;Kwak, Hyung-Bin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.79-85
    • /
    • 2014
  • Purpose: This study investigated accommodative changes by measuring accommodative response, appearing on the normal and convergence insufficiency Group, by using both eyes open-view auto-refractometer (Nvision-K5001, shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 74 college students (54 males and 20 females) aged between 19 and 29 ($21.59{\pm}2.53$), spherical equivalent OD $-2.28{\pm}2.03$ D, OS $-2.18{\pm}2.01$ D, by measuring accommodative responses at full correction and under correction with plus lens +0.25, +0.50, +0.75 arbitrarily added. Results: In the group of normal and convergence insufficiency, the shorter fixation distances were, the greater accommodative lags showed. The group of convergence insufficiency showed the lesser changes of accommodative response than those of normal. But we found that the convergence insufficiency group had a little larger accommodative amplitude in the total fixation distances. The full correction of convergence insufficiency group and the under correction (+0.50 D) of normal were alike in the accommodative responses. We have also investigated that the correlation between accommodative responses and fixation distances was decreased steeply at the excessive low vision correction. Conclusions: Under correction (+0.50 D) in a near distance is expected to avoid unnecessary accommodative responses, make eyes relaxed and comfortable.

An Evaluation of Habitual Head Posture in Phoria (사위에서 습관적인 머리위치의 평가)

  • Ha, Eun-Mi;Son, Jeong-Sik;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.341-346
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate whether a relationship exists between head posture and phoria, and usefulness in examining habitual head posture. Methods: Twenty two subjects (20 males and 2 females, mean age $23.6{\pm}2.7$ years) with abnormal phoria from participants randomized were enrolled in this study. For all subjects, testing included case history, cover test, refraction, phoria and vergence test. Habitual head posture (head posture, head tilt and face turn) was measured by Impression IST, and observed by examiners. Results: The abnormal head posture was revealed in some subjects with abnormal phoria. Spearman' correlation ($\rho$=0.524, p=0.045) showed significant correction between face turn and phoria at distance in 15 subjects with prism prescription. No significant relationship between head posture and phoria was found in subjects with abnormal phoria. The objective measurement and subjective observation of head posture showed insignificant correction but there was a distinct difference. The former was detail and the latter was discriminate. Conclusions: Presence of abnormal head posture was found in phoric subjects. The results indicate the need to observe habitual head posture at all major positions of gaze in phoria.