• Title/Summary/Keyword: Optometry

Search Result 577, Processing Time 0.029 seconds

A New Application of Human Visual Simulated Images in Optometry Services

  • Chang, Lin-Song;Wu, Bo-Wen
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.328-335
    • /
    • 2013
  • Due to the rapid advancement of auto-refractor technology, most optometry shops provide refraction services. Despite their speed and convenience, the measurement values provided by auto-refractors include a significant degree of error due to psychological and physical factors. Therefore, there is a need for repetitive testing to obtain a smaller mean error value. However, even repetitive testing itself might not be sufficient to ensure accurate measurements. Therefore, research on a method of measurement that can complement auto-refractor measurements and provide confirmation of refraction results needs to be conducted. The customized optometry model described herein can satisfy the above requirements. With existing technologies, using human eye measurement devices to obtain relevant individual optical feature parameters is no longer difficult, and these parameters allow us to construct an optometry model for individual eyeballs. They also allow us to compute visual images produced from the optometry model using the CODE V macro programming language before recognizing the diffraction effects visual images with the neural network algorithm to obtain the accurate refractive diopter. This study attempts to combine the optometry model with the back-propagation neural network and achieve a double check recognition effect by complementing the auto-refractor. Results show that the accuracy achieved was above 98% and that this application could significantly enhance the service quality of refraction.

A Research on Career Awareness of the Students Majoring in Department of Optometry in Gyeongnam Area (경남지역 안경광학과 학생들의 진로의식 조사)

  • Kim, Bong-Hwan;Han, Sun-Hee;Hwang, Ji-Hyeon;Park, Min-Ji;Jang, Yeong-Hee;Park, Eun-Hee;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.4
    • /
    • pp.216-222
    • /
    • 2014
  • Purpose. The purpose of this study was to investigate career awareness of the students majoring in optometry in Gyeongnam area so that it could be used as a database to educate them on their career. Methods. The graduates of the Department of Optometry in 6 universities of Gyeongnam area were surveyed through a questionnaire. Results. Most of their motive for entering Department of Optometry was for 'finding a job(38%), while at the time of entrance, most of them (55%) thought 'optician' as their job after graduation. Now most of them are the expectant graduate and they still think 'optician' as their job(54%). The biggest reason why they think of this career was 'aptitude(34%),' and most of them wanted their first monthly wage as less than '1.5 million won (46%).' For the desired work time, most of them said 'less than 10 hours a day (73%),' and they have been figured out to want '2 days off a week and monthly paid holiday (35%).' For the questions asking any improvements that are needed for department of Optometry, they (32%) answered 'equipments that are old or in short.' For the question asking if they are willing to choose optical task even if they entered a company that is irrelevant with it, most of them (37%) said they will if the conditions work, and the other 37% said they didn't know. Conclusions. The cooperation among universities and the field and their interest are required so that the students of the Department of Optometry would be able to work with pride as a professional to improve social welfare.

The Global Status of Ophthalmic Education and Legislation (검안 교육과 법률의 국제적 현상)

  • Penisten, Douglas K.;Di Stefano, Anthony F.;Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.73-84
    • /
    • 2003
  • This paper reviews the current status of ophthalmic education and legislation worldwide. The impact of the profession of optometry in providing eye and vision care in different regions of the world and strategic directions for optometry in Korea are discussed. The role of the World Council of Optometry in advancing the access and delivery of eye and Vision care is emphasized.

  • PDF

Analysis of refractive error according to the position of vision measurement using an automatic refractor (자동굴절검사기를 이용한 시력측정 자세에 따른 굴절이상도 분석)

  • Bong-Hwan, Kim;Sun-Hee, Han;Se-Hyeon, An;Chang-Seop, Sin;Won-Jeong, Jang;In-Seon, Hwang;Hyung-Soo, Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.10 no.2
    • /
    • pp.1587-1593
    • /
    • 2022
  • Purpose. This study was to investigate the degree of refractive error that occurs depending on the measurement location of the subject when performing a refraction test using the automatic refractor. Methods. When performing the auto-refraction test, measurements were taken while increasing the distance between the forehead and the forehead rest, and the measurements were made by tilting the head clockwise and counterclockwise. Results. During the auto-refraction test, significant refractive error occurred when the forehead was not attached to the forehead support or the subject's head was turned clockwise or counterclockwise. Conclusions. When performing a refraction test using an automatic refractor, the examiner will have to pay attention to whether the subject's forehead is in close contact with the forehead rest, and whether the head is tilted.

A Survey on the Awareness of Consumers on the Expertise of Optometrists (소비자가 생각하는 안경사의 전문성에 대한 인식도 조사)

  • Han, Sun-Hee;Kim, Bong-Hwan;Yun, Da-bhin;Song, Jeong-Ho;Yoon, Ji-Min;Kim, Hyeong-Su
    • Journal of Korean Clinical Health Science
    • /
    • v.9 no.2
    • /
    • pp.1502-1510
    • /
    • 2021
  • Purpose. To investigate on the awareness of consumers on the expertise of optometrists. Methods. Data were collected and analyzed through an online questionnaire targeting 63 consumers (42 consumers over the age of 10 who wore glasses, and 21 students in the Department of Optometry). Result. As a consideration when choosing an optometrist, consumers considered the variety of products (15 persons(23.8%)), expertise such as optometry and fitting, kindness and credibility (11 persons(17.5%)). Students in the Department of Optometry of each selected expertise such as optometry and fitting, kindness and credibility (5 persons(7.9%)) and the results were high. In addition, about the main tasks of optometrists, 20 consumers (31.7%) and 9 students (14.3%)(SD 14.5±5.5) answered that they were medical technicians specializing in vision health. And the service satisfaction of the optometrist (5 point scale) was evaluated as 3.77 points for the consumers and 3.76 points for students(SD 3.77±0.01), and the reliability (5 point scale) for the consumers was 3.42 points and students 3.53 points (SD 3.48±0.06). In terms of expertise (5 point scale), the consumers scored 3.47 points and current students 3.58 points (SD 3.53±0.06). Conclusion. As a result of the study on consumer awareness of the expertise of optometrists, there was no significant difference in the perceptions of the reliability, service, and expertise of optometrists in the opinion of the consumers and students of the Department of Optometry. In terms of reliability and expertise, students in the Department of Optometry were evaluated somewhat higher than the consumers. Therefore, in order for consumers to be able to trust the expertise of optometrists in the future, it is necessary to take pride in being a medical technician specializing in vision health, and to actively promote and make efforts to inform consumers that optometrists are experts recognized by the state.

The Change of the Near Eye Position according to the Spectacle and Contact Lens Wearing (안경과 콘택트렌즈 착용에 따른 근거리안위의 변화)

  • Han, Sun-Hee;Kim, Bong-Hwan;Kim, Hak-Jun;Park, Jun-Sung;Park, Hae-Been;Kim, Mi-Jeong;Park, Ju-Hyeong;Kim, Jin-Sol;Lee, Kyeong-Hoon;Kim, Jong-Hwan;Ha, Na-Ri
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.4
    • /
    • pp.435-443
    • /
    • 2015
  • Purpose. This study was to investigate comparison of the near eye position according to the spectacle and contact lens wearing. Methods. We measured the AC/A ratio and near horizontal phoria using modified Thorington method in each case spectacle and contact lens wearing of equivalent spherical power after measuring the full corrected diopter for 20 subjects (men 5, woman 15, $21.15{\pm}1.35$ years) without specific ocular diseases, ocular surgery experience and vision anomalies. Results. It was shown high correlation between spectacle and contact lens wearing as AC/A ratio is a correlation coefficient 0.99 (p=0.00), near horizontal phoria is a correlation coefficient 0.95 (p=0.00). And contact lens wearing increased as AC/A ratio by $0.32{\pm}1.35$ ${\Delta}/D$ (p=0.31) and near horizontal phoria by $-0.17{\pm}2.18$ ${\Delta}$ (p=0.73) than spectacle wearing but there was no statistically significant difference. As the higher myopic grade AC/A ratio increased and then was shown decreased tendency in -6.00 D < $SED{\leq}-4.00$ D group (p>0.05) and as the higher myopic grade near exophoria increased but there was no statistically significant difference (p>0.05). Conclusions. We should consider that the subjects who had the lower AC/A ratio or higher near exophoria in -6.00 D < $SED{\leq}-4.00$ D group were necessary to measure AC/A ratio and near horizontal phoria when they were wearing contact lens because contact lens wearing tended to increase the near exophoria than spectacle wearing.

Empirical Fitting Curve for Luminous Transmittance in Tinted Lenses Using Superposition of Exponential Decay Curves (지수감소곡선의 중첩을 이용한 착색렌즈 시감투과율의 실험적 맞춤곡선)

  • Choi, Eun Jung;Lee, Sin Ui;Lee, Eun Jin;Yoon, Moon Joo;Jeong, Ji-Hyeon;Kim, Chang-Jin;Yang, Gye Tak;Jeong, Ju-Hyun;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.283-291
    • /
    • 2011
  • Purpose: To find an empirical fitting curve to represent the relationship between the luminous transmittance and tinted time in tinted lenses using exponential decay curves. Methods: Total ninety tinted lenses were prepared with CR-39 lenses and six different colored dyes. Single, double and triple exponential decay curves were used as trial curves in order to find the empirical fitting curve. Result: The results showed that the best empirical fitting curve was triple exponential decay curves. Conclusions: We propose triple exponential decay curves as proper empirical fitting curves to represent the tinted-time dependence of the luminous transmittance in tinted lenses.

A Questionnaire Study on Present Status of the Cyberchondria in Korean Optometry (한국 안경광학 분야에서 사이버콘드리아의 현황에 관한 설문 조사 연구)

  • Wang, Mi Young;Lee, Sun Ah;Kim, Dal-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.97-105
    • /
    • 2011
  • Purpose: The aim of this study was to figure out present status of the cyberchondria in Korean optometry and present an appropriate countermeasure against it. Methods: We conducted a survey of consumer group and optician group about the cyberchondria, and analyzed its results. Results: In Korean optometry, a large difference of awareness of the on-line information was revealed between the consumer group and the optician group, so that we could know existence of the cyberchondria. Conclusions: We conclude that opticians' active consulting is the most proper and effective countermeasure against the cyberchondria.

The Correlation Between Corneal Eccentricity and Radius Curvature by Fitting Status of Soft Contact Lens Wearer (소프트 콘택트렌즈 착용자의 피팅 상태에 따른 각막 이심률과 곡률반경과의 상관관계)

  • Han, Sun-Hee;Kim, Bong-hwan;Park, Jun-Sung;Baek, Su-won;Kwon, Sung Jin;Kim, Eun Kyoung;Yoon, Jung Na;Choi, So Min;Heo, A Jeong;Park, Eun Hye
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.662-670
    • /
    • 2016
  • Purpose. Because of a recent increase in use of soft contact lens at younger ages, in the present study, the correlation between corneal eccentricity and radius of curvature and fitting types of contact lens was investigated. Methods. The study evaluated the fitting status of targets through lens centration, push-up test, dynamic lag test and static lag test of lenses usually worn by 49 men and women (98eyes) in their 20s to 30s who put on soft contact lenses. After evaluation, the subjects were classified into 3 categories by fitting status(steep, aligment and flat). The radius of corneal curvature in the naked eyes was measured by using keratometer. Moreover the corneal eccentricity in the nasal side, temporal side, superior side and inferior side was measured by using the device capable of measuring the corneal eccentricity. Results. The radius of corneal curvature and corneal eccentricity of soft lenses worn by subjects were higher in the order of steep fitting and flat fitting, and the higher average corneal curvature radius and corneal eccentricity is intend to be more steep fitting(p=0.051, p=0.052). The corneal eccentricity showed a tendency to nasal fitting type at the higher eccentricity and temporal fitting type at the smaller eccentricity, statistically significant difference was observed(p<0.05). The study showed there were low correlation that nasal and temporal side at steep fitting, superior side at normal fitting and 4side(nasal, temporal, superior, inferior) at flat fitting, therefore when the corneal eccentricity changed the radius of corneal curvature also changed. The corneal eccentricity and the radius of corneal curvature showed statistically significant difference at 4side and each fitting types(p<0.05). Conclusions. The results of this study, the fitting status, of wearer are based on radius of corneal curvature and corneal eccentricity, and if lens fitting would be done considering that, it seems to be useful in a soft contact lens prescription.

Current Status of Ophthalmic Optometry Laboratory Personnel in Korea, Japan, and the United States (한국, 일본, 미국 안과검사인력의 현황)

  • Okhwan, Jeon;Junbeom, Park;Dae Jin, Kim;Dae Eun, Kim;Cheol, Moon;Bon-Kyeong, Koo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.4
    • /
    • pp.285-292
    • /
    • 2022
  • The education and training system, the ISCO (International Standard Classification of Occupations), and the legal systems of Japan and the United States consider all ophthalmic optometry laboratory personnel as ophthalmologists. They encompass optometrists, orthoptists, optometric technicians, and ophthalmic medical technicians. Data retrieved from the KOSIS (Korean Statistical Information Service) revealed that the number of opticians associated with the department of ophthalmology in 2022 could be appraised by classifying their medical institutions; contrarily, the number of clinical laboratory technologists could not be assessed. However, the current research investigated a general tertiary hospital and determined that clinical laboratory technologists outnumber opticians. Classification in Korea is based on ophthalmic optometry laboratory personnel, ISCO, ISCED (International Standard Classification of Education), the medical service act, the act on medical service technologists, and the higher education act. These results cannot be compared to the optometrists evaluated in the United States. Ophthalmology is a suitable profession for optometric technologists and technicians who perform under the instructions of ophthalmologists and optometrists. The field of eye healthcare would be benefitted by assigning the management based on their qualification according to the requirement of the job title, such as 'Clinical Optometry Technologist' to be given to clinical laboratory technologists and opticians who work in the ophthalmic optometry laboratories after obtaining a private qualification endowed by the Korean Ophthalmological Society and the Korean Optometry Society.