• Title/Summary/Keyword: Optimum treatment criteria

Search Result 25, Processing Time 0.025 seconds

Development of the Automatic Control System for the Advanced Phosphorus Treatment in Sewage Treatment Plant (하수처리시설에서 인 고도처리를 위한 자동제어시스템 개발에 관한 연구)

  • Kim, Seon-Gok;Lee, Ho-Sik;Jun, Tae-Sung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.300-304
    • /
    • 2012
  • It has a limitation to satisfy the phosphorus effluent criteria of 0.2 mg/L which will be reinforced from 2012 with the Biological Nutrient Removal (BNR) process. The chemical coagulation process has been operated in parallel with the biological treatment process for advanced treatment of phosphorous in the developed countries including Europe. However, the coagulation process has some disadvantages such as the desired goal may not be achieved without injecting the optimum dosage of the coagulant. This study developed the automatic control system to inject the optimum dosage of phosphorous coagulant into the coagulation process. The adopted coagulant was 10% Poly Aluminum Chloride (PAC) in this study. The automatic control system developed in this study was adopted for the treatment of the phosphorus from the effluent in SBR process. The automatic control system was composed of the data receiving part, the optimum coagulant dosage control part and the data transmit part. The result of the phosphorous advanced treatment of the SBR effluent using the automatic control system showed the removing efficiency over 95% consistently with the phosphorous concentration under 0.02 ~ 0.15 mg/L. The reproducibility analysis for checking the safety of automatic control system showed more than 95% correlation.

Dynamic EMCs and Optimum Treatment Criteria for Stormwater Runoff of a Railway Station (철로 역사 건설에 따른 강우 유출수내 비점오염물질의 동적 EMCs 및 처리방안 연구)

  • Lim Kyeong-Ho;Kim Kee-Dong;Lee Byung-Sik;Kim Lee-Hyung
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.4
    • /
    • pp.308-313
    • /
    • 2005
  • In order to successfully propel the stormwater management program, administration plan of stormwater management is enacted in Spring, 2005. Hereafter, in a newly developing area such as a railway station, the best management practices should be established to control the nonpoint pollutant. Construction of a railway station means the increasing of imperviousness rate and lots of nonpoint pollutant emissions during rainfall. Therefore this research was performed to determine the pollutant EMC and to suggest the possible best management practice for treating nonpoint pollutants from a railway station. The $95\%$ confidence intervals of pollutant EMC were ranged to 69.4-115.2mg/L for TSS, 132.7-190.4mg/L for COD, 5.4-15.1ug/L for Oil & Grease, 4.9-12.4mg/L for TKN and 568.4-620.1ug/L for TP. The first flush criteria was ranged to 5-10mm accumulated rainfall using dynamic EMCs, Also laboratory reactor testing was performed. It shows that Zeolite media is useful for removing the washed-off pollutants from a railway station, especially for metal ions.

An Application of AHP for the Selection of Optimum Product of BWTS for over 10,000 TEU Container Ship (AHP 기법을 이용한 10,000 TEU 이상 컨테이너선에 적용되는 선박평형수 처리장치 최적제품 선정에 관한 연구)

  • Lee, Sang-Won;Kim, Dong-Joon;Seo, Won-Chul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.5
    • /
    • pp.395-406
    • /
    • 2015
  • The Ballast Water Treatment System was developed to prevent the unintended transport of unwanted organisms from one region to another as demanded by the IMO (International Maritime Organization). Although various types of BWTS in the world have been developed until now and applied to various ships, there has been no systematic basis for its selection and installation. Currently, the system selection and installation are as per ship owner’s suggestion or by easy installation point of view by the shipyard. In order to organize, systemize and solve problems related to the selection and installation of BWTS, a definitive study has been performed to come up with the best alternative to derive value and criteria which were to be met for vessels which are to be equipped with BWTS. Multiple criteria were compared alongside each other during the course of this study. Accordingly an AHP (Analytic Hierarchy Process) analysis method for A, B and C companies were done for container ships with size 10,000 TEU and above. Equipment type for “A” company is “Filter, UV & TiO2” combined type. For “B” company it is “Filter & UV” combined type. Finally for “C” company it is “Electrolysis” type. Henceforth, the results of this study aims to come up with the optimum way to select the best and the most suitable BWTS for a certain vessel.

A Study on the Recreation Carrying Capacity of Lawn Areas in Parks(I) -Estimation of treading times criteria based on the tolerence of the turf to treading pressure- (공원잔디공간의 『레크레이션』 수용능력에 관한 연구(I) -잔디에 미치는 답압의 영향 및 수용능력의 답압회수 기준설정-)

  • 엄붕훈
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.20 no.1
    • /
    • pp.53-68
    • /
    • 1992
  • This study was carried out to estimate the recreation carrying capacity of lawn areas in parks. Recreation carrying capacity in this study is composed of two parts, ecological carrying capacity and psychological carrying capacity. As the first part, this paper deals with the treading times criteria based on the tolerence of the turf to treading pressure. The plant material used for this study was Zoysia japonica, and the treading experiment was done in the experimental fields in Kyungju and Suwon, Korea. The major results of the first part of the study are summarized as follow: 1. As shown in annual change of the growth of the turf, The growth of turt grass was represented by the number of leaf. 2. The tolerance to treading was not significantly different by the time of treading treatment. And the tolerance varies depending on growth rate of grasses, which showed significant relationship with precipitations. 3. From the result of different numbers of simulated treading treatment, the damage of the turf was increased by the increase of the frequency of treading. And the damage was very serious within short period(about 20 days) in high frequency(over 20 times/day) of treading treatment. But low frequency(1∼3times/day) of treading shows good effects on the growth of the turf. 4. The criteria of treading number per day for each carrying capacity level are estimated as 7 times/day for optimum carrying capacity, 13 times/day for standard carrying capacity, and 20 times/day for critical carrying capacity.

  • PDF

Effects of Surface Treatment on Field Emission Properties for Carbon Nanotube Cathodes (탄소나노튜브 캐소드에서 표면처리 방법이 전계방출 특성에 미치는 영향)

  • Seong, Myeong-Seok;Oh, Jeong-Seob;Lee, Ji-Eon;Jung, Seung-Jin;Kim, Tae-Sik;Cho, Young-Rae
    • Korean Journal of Materials Research
    • /
    • v.16 no.1
    • /
    • pp.37-43
    • /
    • 2006
  • Carbon nanotube cathodes (CNT cathodes) were fabricated by a screen printing method using multi-walled carbon nanotubes. The effects of surface treatment on CNT cathodes were investigated for use in high efficiency field emission displays. The optimum surface treatment for a CNT cathode is dependent on a relative bonding force of CNT films on the cathode after a heat treatment. Because of the high bonding force used in the Liquid method, this method is recommended for CNT cathodes which are heat-treated at $390^{\circ}C$ in a $N_2$ atmosphere. The Rolling method is applicable for CNT cathodes fabricated at $350^{\circ}C$ in an atmosphere of air. The results of this study provide basic criteria for the selection of an appropriate surface treatment for large area CNT cathodes.

Optimum Sewage Discharge Strategy for Coastal Waters

  • Kang, Yun-Ho;Lee, Moon-Ock
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_3
    • /
    • pp.97-106
    • /
    • 2001
  • To improve the water quality, particularly for sea bathers, the behaviour of wastewater from sewage outfalls in water adjacent to Swansea, UK, was studied using a mathematical model. The water quality in the sewage receiving basin was determined using factors like the outfall diffuser location(distance from land boundary), sewage treatment scheme, discharge time, and bacteria decay rate, etc. With respect to these factors, an optimal strategy for sewage discharge was then investigated to minimize bacteria levels along the bathing beaches. As water quality criteria, predicted faecal coliform levels were monitored along the coast adjacent to the outfall locations. The resultant values were compared with EC Mandatory(<2000, 95 % of 20 samples) and Guideline Standards(< 100, 80 % of 20 samples). For the advective-diffusion equation, the non linear advective terms were represented using the ULTIMATE algorithm and the third-order accurate QUICKEST scheme to avoid numerical diffusion. Details of the simulation results are then presented as an optimal policy for sewage discharge in the region.

  • PDF

A Study for Optimal Dose Planning in Stereotactic Radiosurgery

  • Suh, Tae-suk
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.23-29
    • /
    • 1990
  • In order to explane the stereotactic procedure, the three steps of the procedure (target localization, dose planning, and radiation treatment) must be examined separately. The ultimate accuracy of the full procedure is dependent on each of these steps and on the consistancy of the approach The concern in this article was about dose planning, which is a important factor to the success of radiation treatment. The major factor in dose planning is a dosimetry system to evaluate the dose delivered to the target and normal tissues in the patient, while it generates an optimal dose distribution that will satisfy a set of clinical criteria for the patient. A three-dimensional treatment planning program is a prerequisite for treatment plan optimization. It must cover 3-D methods for representing the patient, the dose distributions, and beam settings. The major problems and possible modelings about 3-D factors and optimization technique were discussed to simplify and solve the problems associatied with 3-D optimization, with relative ease and efficiency. These modification can simplify the optimization problem while saving time, and can be used to develop reference dose planning system to prepare standard guideline for the selection of optimum beam parameters, such as the target position, collimator size, arc spacing, the variation in arc length and weight. The method yields good results which can then be simulated and tailored to the individual case. The procedure needed for dose planning in stereotactic radiosurgery is shown in figure 1.

  • PDF

The Condition of Optimum Coagulation for Recycling Water from CMP Slurry

  • Seongho Hong;Oh, Suck-Hwan
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.415-420
    • /
    • 2001
  • Water usage in the semiconductor industries is dramatically increased by not only using bigger wafer from 8 inches to 12 inches but also by adapting new process such as Chemical Mechanical Planarization (CMP) process invented by IBM in late '80. However, The document published by International Semiconductor Association suggests the decreasing ultra pure water (UPW) use from 22 gallon/in$^2$in 1997 to 5 gallon/in$^2$ in 2012. The criteria will possibly used as exporting obstacle in the future. Generally, Solid content of CMP slurry is about 15wt%. The slurry is diluted with UPW before fed to a CMP process. When the slurry is discharged from the process as waste, it contains 0.1~0.6wt% of solid content and 9~10 at pH. The CMP waste slurry is discharged to stream with minimum treatment. In this study, to find optimum condition of coagulation for water recovery from the waste CMP slurry various condition of coagulation were examined. After coagulation far 0.1 wt% solid content of waste CMP slurry, the sludge volume was 10~15% after 30 min of sedimentation time. For the 0.5 wt%, sludge volume was 50~55% after one hour of sedimentation time. For more than 80% of water recycling, the solid content should be in the range of 0.1 to 0.2wr%. Based on the result of the turbidity removal, the Zeta Potential and the analysis of heavy metals, the optimum condition for 0.1 wr% of waste CMP slurry was with 20 mg/L of PACI at 4 to 5 of pH. The result showed that the optimum conditions fer the 0.1 wt% waste CMP slurry were 100mg/L of Alum at 4~5 of pH, 100 mg/L of MgCI$_2$at pH 10 to 11 and 100 mg/L of Ca(OH)$_2$at pH 9 to 11, respectively.

  • PDF

Optimal Policy for a Regional Water Distribution System

  • Ryang, Yong-Joon
    • Journal of the military operations research society of Korea
    • /
    • v.11 no.1
    • /
    • pp.87-110
    • /
    • 1985
  • This paper presents optimum policy of water supply distribution of the Osaka Prefecural Waterworks System located in the midwest of Japanese Islands. Owing to the ever increasing demand for water, the Osaka Prefectural Government endeavors to expand potable and industrial water distribution system to satisfy the growing water demand of the constituents under its jurisdiction. In this regard, the paper discusses a problem of establishing an efficient and effective water distribution system. The criteria to be considered are stability of water level at the reservoirs, stability of flow in the network, and the water treatment and distribution cost. These objective functions may be combined to form a multiple objective optimization problem or may be used independently and formulated into single objective optimization problems.

  • PDF

Chyle leak after head and neck surgeries: a comprehensive review of diagnosis and management strategies

  • Aparna Ganesan;Nehal C. Singh;Naren P. Khatri;Charanjeet Singh Madaan;Savreek Kaur;Amanjot Kaur
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.1
    • /
    • pp.3-12
    • /
    • 2024
  • Chyle leaks are uncommon complications after head and neck surgeries. Although uncommon, such a complication is noteworthy mention due to its perplexing diagnosis and management strategies. This scoping review aims to highlight and emphasize the diagnosis and management options proposed in the literature. A comprehensive search was performed in PubMed, Google Scholar, Cochrane Library, and Scopus databases and identified 617 articles that were reduced to 40 studies and reports after applying the eligibility criteria. Although numerous treatment options ranging from simple, conservative measures to invasive surgical procedures have been mentioned for low-output, high-output, and massive leaks, there is no concrete evidence on the best method. Thus, a combination of management options must be customized by case for optimum results.