• 제목/요약/키워드: Optimum operation condition

검색결과 281건 처리시간 0.033초

정수장 응집공정의 최적운전조건 결정 사례 (Experiences of Optimization of Flocculation Basins in Water Treatment Plants)

  • 한무영;정영균;박용효;김정현
    • 상하수도학회지
    • /
    • 제14권4호
    • /
    • pp.311-317
    • /
    • 2000
  • The operation of flocculation process and the evaluation thereof have been mainly based on G, t and $G{\times}t$ values which are available from design guidelines and texts. However, their suggested ranges are too wide to find the optimum condition specific to a particular water treatment plant and none of the existing method can be used to evaluate and suggest the optimum operational condition. Recently, a commercially available particle counter is found to be useful in determining the flocculation process based on the particle dynamics. The optimum condition is defined as one that best suits the purpose of flocculation; the number of small particles should decrease, while that of large particles should increase. The experiments were performed at two conventional water treatment plants in Korea, one with horizontal mechanical flocculators, and another with vertical type mechanical flocculators. In this paper, experiences to evaluate the flocculation process and to suggest the optimum operation condition will be presented. Although particle counting method is found to be beneficial compared to any other existing methods, the optimum condition is very much site-specific and should be evaluated at each water treatment plant for different conditions.

  • PDF

평면식 건조기의 적정작업조건 설정에 관한 연구 (Study on The Qptimization of Operating Conditions of batch-type Grain Dryer)

  • 박경규;정창주
    • 한국농공학회지
    • /
    • 제16권4호
    • /
    • pp.3600-3610
    • /
    • 1974
  • Experimental work of batch-type dryer was conducted to develop its optimurm operating conditions by analyzing the major factors which affect the drying performance. A laboratory batch-type dryer was constructed and tested for various levels of heated-air rates, and depths of grain deposit. Tong-il rice variety having the initial moisture content of approximaely 23 per cent in wet basis was used for the experiment. The criteria selected for establishing the optimum operating condition were the drying performance rate, the thermal efficiency, and the operational cost of the dryer. The results of the study are summarized as follows: 1. The performance rate of dryer for a specific operating condition was defined as total amount of material dried per hour when the moisture content of grains in the upperlayer reaches to 16 per cent in wet basis. The optimum operating conditions as viewed in the rate of drying performance could be justified by functional realtionship between the depth of grain deposit and air flow rate. In other words, there was a definite depth of grain deposit for a given air-rate which make the dryer performance maximum. The optimum grain depth for the batch-type dryer with 3.3㎡ loading area and with the attached axial fan was about 35cm. 2. The thermal efficiency for the dryer was evaluated by the ratio of the latent heat required to evaporate the grain moisture to the heat input required to raise the ambient air-temperature to 40 degree centigrade. The optimum operating condition as viewed in term of thermal efficiency analyzed was that grater depth and lower air flow-rate may be desirable. This condition is contracted with the optimum condition as viewed by the dryer performance rate. 3. The annual operating cost of batch-type dryer was analyzed for different annual hour of use and for different operation condition. The optimum condition as viewed in terms of operating cost was almost identical to one as viewed in terms of dryer performance rate. Therefore, the most economical use of batch-type dryer for the same annual operating hours can be obtained when the dryer operated in the condition of maximum dryer performance rate. Increasing the annual operating hour may be desirable to cut down the dryer operation cost, since the annual hour of dryer use is much sensitive to the operating cost than any peractical conditions of dryer operation. 4. The most desirable operational condition as justified by combining all the criteria, dryer performance rate, thermal efficiency and annual operating cost, could be concluded to operate the dryer in the condition of maximum performance rate. The condition in general is identical to the lowest operation cost for a given annual operating hour.

  • PDF

파일럿 플랜트 최적운전을 위한 SCR공정 동적 모사 (A dynamic simulation study on SCR (Stream Carbon dioxide Reforming) process for pilot plant operation)

  • 김용헌;배지한;박명호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.136.2-136.2
    • /
    • 2011
  • A dynamic simulation study on SCR process in GTL process was carried out in order to find optimum operation conditions for pilot plant operation. Optimum operating conditions for SCR synthesis gas process were determined by changing operation variables such as feed temperature and pressure. It was also assumed that physical properties of reaction medium were governed by RKS (Redlich-Kwong-Soave) equation. The effect of temperature and pressure on synthesis gas process $H_2$/CO ratio were mainly examined. Dynamic simulation results were fed back to feed operation condition for optimizing productivity, especially for appropriate condition to FT (Fischer-Tropsch) synthesis unit.

  • PDF

An Experimental Investigation of the G-M type Pulse Tube Refrigerator

  • Park, Seong-Je;Koh, Deuk-Yong;Yeom, Han-Kil;Hong, Yong-Ju;Kim, Hyo-Bong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권2호
    • /
    • pp.40-45
    • /
    • 2004
  • The experimental results of the G-M (Gifford-McMahon) type pulse tube refrigerators are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The objectives of this study are to develop the design technology of the G-M type pulse tube refrigerator and acquire its application methods for replacing G-M cryocooler. As a preliminary test, the refrigeration performances of the basic, orifice, and double inlet pulse tube refrigerators were investigated. The lowest temperature obtained in the one-stage pulse tube refrigerator was 34.4K and the refrigeration capacity at the optimum operation condition was 23W at 80K. And the lowest temperature of the second stage cold head in the two-stage pulse tube refrigerators was 18.3K and the refrigeration capacities at optimum condition were 0.45W at 20K and 20W at 80K, respectively. Finally, the lowest temperature obtained in the three-stage pulse tube refrigerator was 29.8K and the refrigeration capacity at the optimum operation condition was 1.3W for 40K and 5W for 70K.

평형운전에 기초한 단상 유도전동기의 실용적인 설계 (Practical Optimum Design of Single-phase Induction Motor Based on Balanced Operation Theory)

  • 백수황;김병택;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.129-131
    • /
    • 2007
  • In this paper, we research improvement in efficiency of single-phase induction motor by adapting the condition of the balanced and quasi-balanced operation. we maintain turns of auxiliary winding of the motor and adjust resistance and reactance. In this condition, resistance value and copper loss are much gloater. Namely, this is the condition only for balancing MMF without consideration of copper loss of stator winding. To make more practical design, therefore, we will perform winding design which is based on balanced operation condition and applies copper loss minimum. The problem of deterioration of starting torque is completed by rotor bar shape design.

  • PDF

단상유도전동기의 효율개선을 위한 평형운전에 관한 연구 (A Study on Balanced Operation for Efficiency Improvement of Single Phase Induction Motor)

  • 백수황;김병택;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.143-145
    • /
    • 2006
  • In this paper, single phase induction motor achieved improvement in efficiency by adapting the condition of Balanced operation and Quasi-balanced operation. Also, the process of efficiency improvement to find the optimum point of secondary resistance and running capacitor for working single phase induction motor is performed in order to attain the conclusion to put out the maximum efficiency at the rated operation point with meeting the starting torque.

  • PDF

대안교육 지역특성화학교의 시설 및 이용현황 조사연구 (A Study on the Architectural Facilities Utilization of Regional Specialized Schools for Alternative Education)

  • 정진주
    • 한국농촌건축학회논문집
    • /
    • 제9권3호
    • /
    • pp.73-82
    • /
    • 2007
  • Ministry of Education and Human Resources presented on December, 2006, 'Alternative school establishment and operation regulation' of contents that can be recognized attainments in scholarship because is authorized if alternative schools fulfill fixed condition. Even though, one time, it was true that several opinions which try to limit to adaptation school of person disqualified for school, thus, various discussion and efforts that specialized school for alternative education does to grow are appearing. However, the expectation which a lot of non authorized schools will apply is not so high because specialized school for alternative education will be controlled in free curriculum and school operation that have been administered and can not be guaranteed school's sell-regulation if acquire legal authorization. Under such social and educational background I surveyed present condition, law, system, literature investigation of existing study, Japanese system and example and authorized two sample specification schools etc. through 'A Basic Study on the Optimum Facilities Criteria Modeling of Regional Specialized Schools for Alternative Education(2006. 10)'. This study was preceded the succession and I visited 17 schools that permit investigation opening of schools among 29 that is authorized until present. So I try to find out architectural planning criteria to activate specialized school for alternative education more through analyzing school's general present condition, establishment idea, operation and specialized education plan, facilities present condition and characteristic.

  • PDF

웨이퍼 폴리싱 공정의 회전속도와 진폭속도에 따른 가공특성 연구 (A Study on the Characteristics of a Wafer-Polishing Process at Various Machining and Oscillation Speed)

  • 이은상;이상균;김성현;원종구
    • 한국기계가공학회지
    • /
    • 제11권1호
    • /
    • pp.1-6
    • /
    • 2012
  • The polishing of silicon wafers has an important role in semiconductor manufacturing. Generally, getting a flat surface such as a mirror is the purpose of the process. The wafer surface roughness is affected by many variables such as the characteristics of the carrier head unit, operation, speed, the pad and slurry temperature. Optimum process conditions for experimental temperature, pH value, down-force, slurry ratio are investigated, time is used as a fixed factor. This study carried out a series of experiments at varying platen, chuck rpm and oscillation cpm taking particular note of the difference between the rpm and the affect it has on the surface roughness. In this experiment determine the optimum conditions for polishing silicone wafers.

다구찌 방법을 이용한 시로코 홴의 최적설계에 관한 실험적 연구 (An Experimental Study on the Optimum Design of Sirocco Fan by Using Taguchi Method)

  • 김장권
    • 대한기계학회논문집B
    • /
    • 제23권6호
    • /
    • pp.761-768
    • /
    • 1999
  • This paper is studied to find the optimum condition of double-inlet Sirocco fan installed in an indoor PAC for low noise operation by the Taguchi method. The goal of this study is to obtain the best combination of each control factor which results in a desired flowrate of Sirocco fan with minimum variability. In this study, the parameter design of the Taguchi method is adopted for robust design by the dynamic characteristic analysis using orthogonal arrays and S/N ratios. The flowrate measurements are conducted by using a multiple-nozzle-type fan tester according to the orthogonal array L9($3^4$). The results of this study can be summarized as follows ; (i) The optimum condition of control factor is a set of where A is an inner to outer diameter ratio($D_1/D_2$), B is a width to outer diameter ratio($L/D_2$), C is a blade attachment angle(${\theta}$) and D is a number of blade(Z), (ii) The flowrate under the optimum condition satisfies the equation $y=0.0384{\cdot}M$ where M is a signal factor, namely number of revolution. The flowrate performance improves about 7.3% more largely as compared with the current condition, which results in about 35RPM reduction of number of revolution for the target flowrate $18.5m^3/min$, and (iii) The sensitivity analysis shows that the major factors in contribution to flowrate performance are A, B, and D ; the percentage contributions of each control factor are 44.01%(Z), 26.77%($D_1/D_2$) and 20.42%($L/D_2$).

정전 용량변화에 따른 대기압 DBD 반응기의 동작 특성 연구 (The operation properties of DBD reactors in air pressure with varying the capacitance of reactors)

  • 박봉경;김윤환;장봉철;조정현;김곤호
    • 한국진공학회지
    • /
    • 제10권4호
    • /
    • pp.440-448
    • /
    • 2001
  • 논문에서는 원통형 및 평판형 반응기에 20 kV의 사각파형 펄스전원을 인가하여 대기압 절연막 방전 플라즈마 반응기의 동작특성을 관찰하였다. 전류-전압파형과 하전량-전압곡선을 관찰한 결과 반응기의 정전용량 크기에 따라서 최적의 운전효율을 갖는 최적운전주파수 $f_0$$f_0\proptoexp(-C)$의 관계를 갖고 있음을 알았다. 이 관계를 이용하여 반응기에서 소실되는 소모전력을 구하였다. 반응기의 소모전력은 반응기의 구조와 전극의 유전물질의 종류 등의 함수인 반응기 정전용량 값에 따라서 변화하였으며 반응기의 특정한 정전용량 값에서 최대값을 가졌다. 이 정전용량 값을 이용하여 최적효율을 갖는 DBD 반응기를 설계할 수 있을 것으로 사료된다.

  • PDF