• Title/Summary/Keyword: Optimum operating condition

Search Result 298, Processing Time 0.027 seconds

Study on The Qptimization of Operating Conditions of batch-type Grain Dryer (평면식 건조기의 적정작업조건 설정에 관한 연구)

  • 박경규;정창주
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.4
    • /
    • pp.3600-3610
    • /
    • 1974
  • Experimental work of batch-type dryer was conducted to develop its optimurm operating conditions by analyzing the major factors which affect the drying performance. A laboratory batch-type dryer was constructed and tested for various levels of heated-air rates, and depths of grain deposit. Tong-il rice variety having the initial moisture content of approximaely 23 per cent in wet basis was used for the experiment. The criteria selected for establishing the optimum operating condition were the drying performance rate, the thermal efficiency, and the operational cost of the dryer. The results of the study are summarized as follows: 1. The performance rate of dryer for a specific operating condition was defined as total amount of material dried per hour when the moisture content of grains in the upperlayer reaches to 16 per cent in wet basis. The optimum operating conditions as viewed in the rate of drying performance could be justified by functional realtionship between the depth of grain deposit and air flow rate. In other words, there was a definite depth of grain deposit for a given air-rate which make the dryer performance maximum. The optimum grain depth for the batch-type dryer with 3.3㎡ loading area and with the attached axial fan was about 35cm. 2. The thermal efficiency for the dryer was evaluated by the ratio of the latent heat required to evaporate the grain moisture to the heat input required to raise the ambient air-temperature to 40 degree centigrade. The optimum operating condition as viewed in term of thermal efficiency analyzed was that grater depth and lower air flow-rate may be desirable. This condition is contracted with the optimum condition as viewed by the dryer performance rate. 3. The annual operating cost of batch-type dryer was analyzed for different annual hour of use and for different operation condition. The optimum condition as viewed in terms of operating cost was almost identical to one as viewed in terms of dryer performance rate. Therefore, the most economical use of batch-type dryer for the same annual operating hours can be obtained when the dryer operated in the condition of maximum dryer performance rate. Increasing the annual operating hour may be desirable to cut down the dryer operation cost, since the annual hour of dryer use is much sensitive to the operating cost than any peractical conditions of dryer operation. 4. The most desirable operational condition as justified by combining all the criteria, dryer performance rate, thermal efficiency and annual operating cost, could be concluded to operate the dryer in the condition of maximum performance rate. The condition in general is identical to the lowest operation cost for a given annual operating hour.

  • PDF

A study of the performance on large capacity screw compressors (중대형 스크루 압축기의 성능에 관한 연구)

  • Park, D.S.;Yang, S.H.;Lee, D.J.;Shin, J.K.;Yoo, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.668-671
    • /
    • 2001
  • For the saving of energy consumption, it is necessary that the high efficient energy transfer machine. We found the optimum operating condition of screw water chiller during this performance test. The specifications of compressor for this performance test are as follows. Built-in volume ratio; Vi=2.4, using refrigerant; HCFC-22, nominal motor output; 60kW(80Hp). We found the test results on water cooled chiller standard test condition that the evaporating capacity is increased 8% maximum and 5.6% under same operating condition. and COP is increased 11 % max. and 8% under same operating condition with change of the evaporating inlet/outlet condition. For the results of these test, we can estimate the optimum operating condition of water cooled type screw chiller.

  • PDF

Optimum Design Condition of the Collins Cryocooler (Collins 내동기의 최적 설계조건)

  • Lee, S.W.;Kim, S.Y.;Jung, P.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.183-190
    • /
    • 1992
  • The Collins cryocooler is numerically analysed with the optimization technique, and the optimum operating and design conditions are searched. This paper shows that liquefied helium quantity has an external maximum w.r.t. the total mass flow rate, the mass flow rates through expander and the capacities of heat exchangers. The liquefied helium quantity increases as the compressor exit pressure of the cryocooler does. The maximum quantity of liquefied helium and the maximum coefficient of performance have been found to exist in extremum, depending on the ratios of each heat exchanger capicities to the total one. At the optimum condition, the capacity of heat exchanger in high temperature region is larger than that in low temperature region.

  • PDF

Application of Analysis of Response Surface and Experimental Designs ; Optimization Methodology of Statistical Model (반응표면(反應表面) 분석(分析)을 위한 실험계획(實驗計劃)과 그 응용(鷹用) 통계적(統計的) 모형(模型)의 최적화수법론(最適化手法論)을 중심으로)

  • Lee, Myeong-Ju
    • Journal of Korean Society for Quality Management
    • /
    • v.7 no.2
    • /
    • pp.22-28
    • /
    • 1979
  • The problem considered in this paper is to select the vital factor effect to the product quality through the experimental design and analysis of response surface, so as to control the quality improvement of industrial product. In this time, even through the mathematical model is unknown it could be applicable to control the quality of industrial products and to determine optimum operating condition for many technical fields, particulary, for industrial manufacturing process. When a set of data is available from an experimental design, it is often of interest 1:0 fit polynominal repression model in independent variables (eg, time, temperature, pressure, etc) the optimize the response variable (eg. yield, strength etc). This paper proposes a method known to obtain the optimum operating condition, and how to find the condition by using table of orthogonal array experiments, and optimization methodology of statistical model. A criterion can be applied determining to optimum operating conditions in manufacturing industry and improving the fit of response surface which may be used for prediction of responses and quality control of industrial products.

  • PDF

Optimum Operating Condition of Air Heating Solar Collector Regenerator Using RSM Technique (RSM 기법을 애용한 태양열 집열판 재생기의 운전 조건 최적화)

  • Jung Jae-ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.89-91
    • /
    • 2004
  • This study examines a regeneration process using hot air heated by solar radiation to recover absorption potential by evaporating moisture in liquid desiccant. More specifically, this study is aimed at finding the optimum operating condition of the regenerator by utilizing a well-established statistical tool, so-called design of experiment, and optimization techniques. It is demonstrated that an optimization model to find the optimum operating condition can be obtained using the functional relationship between regeneration rate and affecting factors which is approximated on the basis experimental results.

  • PDF

Simulation of Solar/Absorption Cooling Hybrid System and Examination of Its Operating Condition (태양열을 이용한 흡수식 냉방시스템의 시뮬레이션과 운전조건의 검토)

  • Her, Jae-Young;Lee, Sang-Yong
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 1985
  • Solar/absorption cooling system was analyzed and its operating condition was examined. For the system, the optimum size of absorption refrigerator and collector area should be determined. As the temperature of water supplied to the generator increases, the collector efficiency decreases whereas the coefficient of performance of absorption refrigerator increases up to a certain point, and vice versa for decreasing of the temperature of water supplied to the generator . Thus if the reeling load is given, the appropriate operating condition can be determined between the two opposing trends by simulation program. As an example of the simulation, the case of Jejudo province was studied. Under the conditions (such as weather data and prices of components, etc.) given en the sample calculation, the result shows that the optimum temperature of water supplied to the generator turned out to be $80.3^{\circ}C$, and still shows a large economical disadvantage in present stage compared to the case of conventional vapor compression cooling/heating combined heat pump system.

  • PDF

A study on the optimum control of refrigerator with on-off control system (On-off 제어계통을 갖는 냉동기의 최적제어에 관한 연구)

  • Ha, J.S.;Kim, W.N.;Kim, K.K.;Oh, C.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.317-327
    • /
    • 1985
  • In the case of temperature control of air conditioning and refrigerating system, it is possible to operate the system continuously by controlling the cooling capacity of refrigerating machines. But on-off control system has been adopted for refrigerating system which has more large capacity than that required to remove the generated heat. In this on-off control system, it can be considered that there exists some optimum condition for the refrigerating capacity, operating cycle, running hour, and the temperature difference between thermostat setting value and real one. In this paper, an equation was derived to express the temperature variation of the refrigerated object (Nybrine) and later two evaluating functions were derived. One is for the temperature difference and another is for operating cycle and running hour. The weighted sum of these two functions is defined as the criterion function for the evaluation of the control performance of the system, and then the optimum running condition is investigated in the sense of minimizing the criterion function. Experiments showed that the heat balance equation derived for the temperature variation and the estimation of the time constant of the refrigerated system are appropriate. By conclusion, if a proper weighting factor D is selected, the optimum conditions exist for the refrigerating capacity, running hour, and operating cycle in the on-off temperature control of the refrigerating system.

  • PDF

Development of Vacuum Nozzle Seeder for Cucuribitaceous Seeds(I) - Design factors for vacuum seeding large sized seeds - (박과 종자용 진공노즐식 파종기 개발(I) 대립종자의 진공파종을 위한 요인구명 -)

  • 김동억;장유섭;김승희;이공인
    • Journal of Biosystems Engineering
    • /
    • v.28 no.6
    • /
    • pp.525-530
    • /
    • 2003
  • This study was carried out to develop a vacuum nozzle seeder for the automation of large seeds sowing of fruit vegetables and rootstocks. Moreover, the seeding efficiency was examined to find the optimum operating condition considering high precision seeding. The important operating factors for high seeding rate were typically nozzle diameter and absorbing vacuum pressure. The optimum nozzle diameters were found 1.5, 1.5 and 2.0 mm for Chambak, Tuktozwa and Hukjong while the optimum vacuum pressures were 8.0㎪, 10.6㎪ and 5.3㎪, respectively. Under the optimum operating condition, the results indicated that the maximum seeding rates were 97.6%, 98.8% and 97.6% respectively for Chambak Tuktozwa and Hukjong. The vibrating acceleration of the hopper did not make any significant effects on the seeding rate when the vacuum pressure reached 8.0㎪ and the sowing rate became higher with lighter seed. As the seed became heavier, the larger diameter of nozzle was recommended 1.5mm of the nozzle diameter was found to be applied for the experimental seeds. The vacuum pressure was also found 8.0㎪ - 13.3㎪ at that time.

Multiresponse Surfaces Optimization Based on Evidential Reasoning Theory

  • He, Zhen;Zhang, Yuxuan
    • International Journal of Quality Innovation
    • /
    • v.5 no.1
    • /
    • pp.43-51
    • /
    • 2004
  • During process design or process optimization, it is quite common for experimenters to find optimum operating conditions for several responses simultaneously. The traditional multiresponse surfaces optimization methods do not consider the uncertain relationship among these responses sufficiently. For this reason, the authors propose an optimization method based on evidential reasoning theory by Dempster and Shafer. By maximizing the basic probability assignment function, which indicates the degree of belief that certain operating condition is the solution of this multiresponse surfaces optimization problem, the desirable operating condition can be found.

A Case study to Improve the Quality of Industrial Products cising An Experimental Design (공업제품(工業製品)의 질적(質的) 향상(向上)을 위(爲)한 실험계획(實驗計劃)의 응용사례(應用事例))

  • Kim, Yu-Song;Lee, Myeong-Ju
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.7 no.2
    • /
    • pp.55-59
    • /
    • 1981
  • An Application of Experimental Designs to Improve the quality of Industrial product : optimization Methodology of statistical model. The primary object of this paper is to aid scientists and Engineers, in applying response surface procedures to obtain operating conditions for many technical fields, particularly for industrial manufacturing processes. The problem considered in this paper is to select technically and scientifically some important factors affecting the quality of products through the experimental design and analysis of response surface. Even though the mathematical model is unknown these statistical analysis can be applicable to control the quality of industrial products and to determine optimum operating conditions for many technical fields, particularly, for industrial manufacturing processes. This paper proposes a method to obtain the optimum operating condition, and how to find the condition by using table of orthogonal array experiments, and optimization methodology of statistical model.

  • PDF