• 제목/요약/키워드: Optimum heating environment

검색결과 61건 처리시간 0.035초

저온온수 모세유관 바닥복사 난방시스템의 성능에 관한 실험적 연구 (Experimental Study on a Low-Temperature Hot Water Capillary Radiant Floor Heating System)

  • 조진균;박병용;이용준;정원호
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.68-82
    • /
    • 2018
  • Radiant floor heating systems with capillary tubes are energy saving systems in which hot water is circulated into capillary tube with a small diameter. In this study, the heating performance of capillary tube system is investigated in an experimental study and a simulation model. The results of the study showed that, the capillary tube radiant floor heating system maintains a more stable floor surface temperature in comparison a PB pipe system. In terms of energy consumption, the capillary tube radiant floor heating system proved to be more efficient than the PB pipe heating system at $40^{\circ}C$ of low temperature hot water supply. The difference between water temperature and room temperature can be held low for heating which saves energy. Low temperature radiant floor heating system with capillary tubes have significant advantages such as health improvement, low energy cost, optimum use of heat source(boiler) and higher operational efficiency.

쿤-터커 조건을 이용한 건물의 에너지성능과 비용 최적화방법 (Optimization Method of Building Energy Performance and Construction Cost Using Kuhn-Tucker Conditions)

  • 원종서;구재오
    • KIEAE Journal
    • /
    • 제3권2호
    • /
    • pp.51-58
    • /
    • 2003
  • The purpose of this study is to present rational methods of multi-criteria optimization of the shape of energy saving buildings. The object is to determine the optimum dimension of the shape of a building, based on the following criteria: minimum building costs (including the cost of materials and construction) and yearly heating costs. Mathematical model described heat losses and gains in a building during the heating season. It takes into consideration heat losses through wall, roof, floor and windows. Particular attention was paid to have a more detailed description of heat gains due to solar radiation. On the assumption that shape of building is rectangle in order to solve the problem, the proportions of wall length and building height are determined by using non-linear programing methods(Kuhn-Tucker Conditions). The results constitute information for designers on the optimum proportions of wall lengths, height, and the ratios of window to wall areas for energy saving buildings.

열전달 시뮬레이션을 통한 최적공극탐지 차트개발 (Development of an Optimum Void Detection Chart using Heat Transfer Simulation)

  • 최현호;박진형;지광습
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.241-244
    • /
    • 2006
  • It is essential to develop a large capacity, non-contact nondestructive inspection system having high reliability to investigate repaired and strengthened structures. Nowadays, an infrared camera is widely used in non-contact nondestructive inspection system. Because an infrared camera is sensitive to the surrounding environment, it is necessary to improve a sensitivity of thermal image information and a relationship between defects and thermal image information. In this papaer, presented is an optimum void detection chart for the optimum conditions to detect infrared rays from inside and outside defects like voids and cracks in concrete structures using extensive computer simulation. Sensitivity studies are performed with respect to variables influencing the temperature distribution such as heating temperature, heating time, and geometries of defect, etc. It may be stated that it could be successfully utilized for the non-contact nondestructive inspection system to detect defects in concrete structures.

  • PDF

전기 저항열을 이용한 유류 오염토 복원공정 적용을 위한 토양의 가열특성 연구 (Heating Characteristics of the Soils for the Application of Electrical Resistance Heating with Soil Vapor Extraction)

  • 윤여복;고석오;박기호;박민호
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제11권1호
    • /
    • pp.45-53
    • /
    • 2006
  • 본 연구에서는 토양의 전기가열 특성을 실험을 통해 규명함으로서, 전기저항열을 이용한 토양증기추출법을 실제 현장에 적용 시 토양가열 효율을 증가시키는 방안을 도출하기 위하여, 반응조를 이용한 토양 종류별 자체 특성에 따른 가열 특성과 외부에서의 전기적 특성의 조절을 통한 가열 특성을 살펴보았다 토양의 업자가 작을수록, 토양 내 이 온이 풍부할수록 전기가열 효율이 증가되었으며, 토양이 물로 포화된 경우에도 전기 가열 효율이 증가하였으나 공극률 이상으로 수분이 있는 경우는 오히려 효율이 떨어졌다. 전압이 증가할수록, 전극 사이가 짧아질수록, 유류 오염된 토양일수록 효율은 증가되었다 본 연구에서는 초기 전류와 전기전도도의 정량적 상관관계를 도출함으로써 직접적인 전기가열 실험 없이 전기전도도로 반응조 내 토양이 $100^{\circ}C$ 온도 상승의 가능성을 예측할 수 있게 됐다.

단경기 아스파라거스 생산을 위한 적정 가온시기 구명 (Determination of Optimum Heating Date for Off-Season Production of Asparagus (Asparagus officinalis L.))

  • 성기철;김천환;이진수;엄영철;문두경
    • 생물환경조절학회지
    • /
    • 제21권3호
    • /
    • pp.276-280
    • /
    • 2012
  • 국내 아스파라거스 생산의 단경기인 12월 생산을 위한 가온시기를 구명코자 수행하였으며 '그린타워' 품종 16~19개월 된 근주를 사용하였다. 가온시기는 2004년 10월 25일부터 2005년 1월 20일 까지 15일 간격으로 7처리로 하였으며 수확시기, 수확량과 품질을 비교하였다. 맹아소요일은 가온시기가 늦어짐에 따라 길어져 12월 30일 가온구에서 52일 로 가장 길게 소요되었으며 이후 점차 짧아졌다. 10월 25일 가온시 11월 7일부터 수확이 가능하였으며, 11월 15일과 11월 30일에 가온할 경우 각각 12월 수확이 가능하였고, 12월 15일 이후 가온 할 경우 1월 상순 이후에 수확이 가능하였다. 주당 순수, 순중 및 총 수량은 휴면이 타파된 1월 10일 이후에 가온하는 처리에서 크게 증가되었다. 그러나 12월 수확을 위해서는 11월 15일에 가온 하는 것이 총수량 및 상품수량에서 각각 607kg/10a와 386kg/10a으로 10월 25일 가온하는 193kg/10a에 비하여 크게 증가되었다. 이상의 결과 제주에서 하우스 재배시 12월 생산을 위한 적정 가온시기는 수량과 품질면에서 11월 15일이 바람직할 것으로 판단되었다.

청소년 수련관의 열원설비 대안별 생애주기 비용에 관한 연구 (Analysis of Life Cycle Cost for Heat Source Equipments in Buildings for Adolescent Trainees)

  • 안창환;방승기;백용규
    • KIEAE Journal
    • /
    • 제5권3호
    • /
    • pp.25-31
    • /
    • 2005
  • Computer simulations were performed for Heating Ventilating and Air-Conditioning (HVAC) systems to figure out more efficient maintenance methods for the building used for adolescent trainees. This study aims at suggesting design alternatives for optimum operation and performing life cycle cost (LCC) for each alternative. First, the capacity of the heat source equipment was determined using annual maximum heating and cooling loads. Annual loads were calculated and applied to the alternative for the purpose of calculating annual energy cost. Second, several types of data were collected to predict energy cost. Finally, the pay back period for each alternative was calculated using total cost estimation during standard duration period. This study indicates that the absorption chiller that does not occupy most part of a mechanical room, and does not need much operation cost was most economical.

교실에서의 천장형 냉난방기의 취출온도 및 취출각도에 따른 열환경 시뮬레이션 (Computer Simulation on the Thermal Environment by the Diffusion temperature and Diffusion Angle of Ceiling Type Air Conditioner in Classroom)

  • 박효순;박승익;이상혁;이감규
    • 교육녹색환경연구
    • /
    • 제4권4호
    • /
    • pp.1-18
    • /
    • 2004
  • Research has been carried out to study thermal environment in a classroom under three kinds of air diffusion temperature and six kinds of air diffusion direction for ceiling type air conditioner. The velocity and temperature distributions of air in the room calculated by 3-dimensional numerical method(PHOENICS), This present study was also conducted to calculate the Air Diffusion Performance Index(ADPI) for cooling conditions and Predicted Percentage of Dissatisfied(PPD) for heating conditions. This analysis shows that the optimum angle of ceiling type air conditioner's diffusion is $15{\sim}30^{\circ}$ for cooling mode and about $15{\sim}45^{\circ}$ for heating mode in these calculating conditions. And also analysis has been carried out to evaluate thermal comfort of vertical and horizontal cross section of classroom.

  • PDF

화력발전소의 온배수를 열원으로 이용하는 시설원예 난방용 히트펌프 시스템의 열교환기 설계기준 설정 (Heat Exchanger Design of a Heat Pump System Using the Heated Effluent of Thermal Power Generation Plant as a Heat Source for Greenhouse Heating)

  • 유영선;강연구;장재경;김영화;김종구;강금춘
    • 생물환경조절학회지
    • /
    • 제21권4호
    • /
    • pp.372-378
    • /
    • 2012
  • 본 연구에서는 화력발전소에서 온배수의 형태로 배출되는 폐열을 히트펌프의 열원으로 이용하여 온실의 난방에 활용할 수 있는 히트펌프 시스템을 설계 제작하였으며, 난방 성능을 분석하여 PE 파이프 열교환기의 설계기준을 제시하고자 하였다. PE 파이프 열교환기의 내경은 20mm, 두께는 2mm였으며, Roll의 직경은 1,000mm로 하였다. 연구결과 PE파이프 열교환기의 적정 길이는 1.0RT당 75m로 설계하는 것이 바람직할 것으로 판단되었으며, 이때 히트펌프시스템의 난방성능계수(COPh)는 3.8로 나타났다.

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Development and Fabrication of Heating and Water Sparging Remediation System (HWSRS) for DNAPL-contaminated Groundwater Treatment

  • Lee, Ju-Won;Park, Won-Seok;Gong, Hyo-Young;Lee, Ae-Ri;Kim, Da-Eun;Baek, Seung-Chon;Lee, Jong-Yeol
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권6호
    • /
    • pp.32-37
    • /
    • 2013
  • The scope of this study was to develop, design, and build an ex-situ remediation system of using the heating and water sparging treatment for the highly volatile DNAPL (Dense Non-Aqueous Phase Liquid) contaminated groundwater, and to conduct pilot testing at the site contaminated with DNAPL. The TCE (Trichloroethylene) removal was at the highest rate of 94.6% with the water sparging at $70^{\circ}C$ in the lab-scale test. The pilot-scale remediation system was developed, designed, and fabricated based on the results of the lab-scale test conducted. During the pilot-scale testing, DNAPL-contaminated groundwater was detained at heat exchanger for the certain period of time for pre-heating through the heat exchanger using the thermal energy supplied from the heater. The heating system supplies thermal energy to the preheated DNAPL-contaminated groundwater directly and its highly volatile TCE, $CCl_4$ (Carbontetrachloride), Chloroform are vaporized, and its vaporized and treated water is return edback to the heat exchanger. In the pilot testing the optimum condition of the HWSRS was when the water temperature at the $40^{\circ}C$ and operated with water sparging concurrently, and its TCE removal rate was 90%. The efficiency of the optimized HWSRS has been confirmed through the long-term performance evaluation process.