• Title/Summary/Keyword: Optimum Performance

Search Result 3,672, Processing Time 0.029 seconds

Performance Evaluation of Location Estimation System Using a Non Fixed Single Receiver

  • Myagmar, Enkhzaya;Kwon, Soon-Ryang
    • International Journal of Contents
    • /
    • v.10 no.4
    • /
    • pp.69-74
    • /
    • 2014
  • General location aware systems are only applied to indoor and outdoor environments using more than three transmitters to estimate a fixed object location. Those kinds of systems have environmental restrictions that require an already established infrastructure. To solve this problem, an Object Location Estimation (OLE) algorithm based on PTP (Point To Point) communication has been proposed. However, the problem with this method is that deduction of performance parameters is not enough and location estimation is very difficult because of unknown restriction conditions. From experimental tests in this research, we determined that the performance parameters for restriction conditions are a maximum transmission distance of CSS communication and an optimum moving distance interval between personal locations. In this paper, a system applied OLE algorithm based on PTP communication is implemented using a CSS (Chirp Spread Spectrum) communication module. A maximum transmission distance for CSS communication and an optimum moving distance interval between personal locations are then deducted and studied to estimate a fixed object location for generalization.

A study of the performance on large capacity screw compressors (중대형 스크루 압축기의 성능에 관한 연구)

  • Park, D.S.;Yang, S.H.;Lee, D.J.;Shin, J.K.;Yoo, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.668-671
    • /
    • 2001
  • For the saving of energy consumption, it is necessary that the high efficient energy transfer machine. We found the optimum operating condition of screw water chiller during this performance test. The specifications of compressor for this performance test are as follows. Built-in volume ratio; Vi=2.4, using refrigerant; HCFC-22, nominal motor output; 60kW(80Hp). We found the test results on water cooled chiller standard test condition that the evaporating capacity is increased 8% maximum and 5.6% under same operating condition. and COP is increased 11 % max. and 8% under same operating condition with change of the evaporating inlet/outlet condition. For the results of these test, we can estimate the optimum operating condition of water cooled type screw chiller.

  • PDF

Determination of the Optimal Design Parameters for Search Task with VDT Screen Written in Korean (탐색작업에서 한글 VDT를 화면의 최적설계 모수의 결정)

  • 황우상;이동춘
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.42
    • /
    • pp.39-47
    • /
    • 1997
  • There are four parameters (i.e. overall density, local density, grouping, layout complexity) to consider in designing screen of a visual display terminal. Among these, only the optimum level of overall density is known to be about 25~30% by some studies. Therefore, the present experiment is conducted to define the optimum levels of the other parameters to achieve the user's best performance in visual search task. The results are as follows; (1) The function related to the levels of local density and user's search times is shown to be U -shaped. When the level of local density is about 40%, the search time is shorter than those of any other levels. (2) In the experiment of grouping, user's performance is best when the number of group is 5, and the size of group does not exceed visual angle $5^{\circ}$ (0,088rad). (3) The user performance is improved as the layout becomes less complex.

  • PDF

A Theoretical Evaluation of the Effect of Refrigerant Charge on the Performance of Vapor-Compression Air-Conditioning System (증기압축식 에어컨의 냉매 충전량에 따른 성능 예측)

  • 이경중;방광현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.486-493
    • /
    • 2000
  • A theoretical model for the transient performance of vapor-compression air-conditioning system has been developed to evaluate the influence of the refrigerant charge on the system performance. A set of mass and energy equations for the simulation of the heat exchangers and the capillary tube and a polytropic compression model for the compressor are used. The present model successfully predicts the transient behavior of the vapor-compression air-conditioner from the startup. As the refrigerant charge is increased, both the evaporating and condensing pressures increase gradually, and the cooling rate and the COP show a maximum in the range of 0.75-0.8 kg of refrigerant charge. This amount of refrigerant mass is determined to be the optimum charge of the model system. Also, the effect of outdoor air temperature on the optimum refrigerant charge is discussed.

  • PDF

Sewage Sludge Thickening Using Electroflotation (전기부상을 이용한 하수슬러지 농축)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.16 no.9
    • /
    • pp.1085-1090
    • /
    • 2007
  • The performance of EF (electroflotation) on the thickening of activated sludge were investigated using laboratory scale batch flotation reactor. In this paper, the effects of parameters such as electrode material, NaCl dosage, initial sludge concentration and electrode distance were examined. The results showed that the performance for sludge thickening of the five electrodes lay in: Pt/Ti > Ru/Ti > Ir/Ti > Ti mesh > Ti plate. The more NaCl dosage was high, the more sludge was thickened and the shorter thickening time was obtained. However, considering the final thickening time and sludge concentration, optimum NaCl dosage was 0.5 g/L. Thickening time and sludge concentration was not affected by electrode distance. In DAF (dissolved air flotation) system, optimum recycle ratio was 40% and thickening performance was lower than that of the EF.

Development of Chemical Equilibrium CFD Code for Performance Prediction and Optimum Design of LRE Thrust Chamber (액체로켓 추력실의 성능 예측 및 최적 형상 설계를 위한 해석코드 개발)

  • 김성구;박태선;문윤완
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.57-60
    • /
    • 2003
  • An axisymmetric compressible flow solver accounting for chemical equilibrium has been developed as an analysis tool exclusively suitable for performance prediction and optimum contour design of LRE thrust chamber. By virtue of several features focusing on user-friendliness and effectiveness including automatical grid generation and iterative calculations with changes in design parameters prescribed through only one keyword-type input file, a design engineer can evaluate very fast and easily the influences of various design inputs such as geometrical parameters and operating conditions on propulsive performance. Validations have been carried out for various aspects by detailed comparisons with the result of CEA code, experimental data of JPL nozzle, actual data for two historical engines, and ReTF data for KSR-III.

  • PDF

Study on optimum structure of free-breathing Polymer Electrolyte Membrane Fuel Cell (PEMFC) for robotic application (로봇용 자연급기형 연료전지의 최적구조에 관한 연구)

  • Choi, Jae-Hyuk;Park, Sang-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.231-238
    • /
    • 2006
  • The performance of free-breathing polymer electrolyte membrane fuel cell (PEMFC) was studied experimentally and the effect of cathode separator structure on the cell performance was investigated. Cathode separators were used for the cell with $18cm^2$ active area. In channel type, the contact resistance is low, and the nature convection. which is strongly affected by the cross-sectional shape of cathode separator channel, is dominant in a cell performance. The maximum power density with $18cm^2$ active area is $105mW/cm^2$ using the 10mm depth and 2mm width channel. A computational analysis was optimum structure of free-breathing channel type PEMFC for robotic application.

Optimum Design of Accelerated Degradation Tests for Weibull Distribution (와이블성능분포인 경우 가속퇴화시험의 최적설계)

  • Choi, Kyu-Moung;Lee, Nak-Young
    • Journal of Korean Society for Quality Management
    • /
    • v.24 no.3
    • /
    • pp.37-49
    • /
    • 1996
  • For highly reliable devices it is often defined to "fail" when its performance degrades below a specified value. In this paper we consider a method for optimally designing accelerated degradation tests(ADTs) in which the performance over exposure time and stress has Weibull distribution. For the product whose performance has Weibull distribution, the optimum plan - low stress level and sample proportions allocated to each test condition - is obtained, which minimize the asymptotic variance of maximum likelihood estimator of a stated quantile at design stress. We also present compromise ADTs plan that can be used for the practical purpose.

  • PDF

Design of TLBO-based Optimal Fuzzy PID Controller for Magnetic Levitation System (자기부상시스템을 위한 교수-학습 최적화 알고리즘 기반의 퍼지 PID 제어기 설계)

  • Cho, Jae-Hoon;Kim, Yong Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.701-708
    • /
    • 2017
  • This paper proposes an optimum design method using Teaching-Learning-based optimization for the fuzzy PID controller of Magnetic levitation rail-guided vehicle. Since an attraction-type levitation system is intrinsically unstable, it is difficult to completely satisfy the desired performance through the conventional control methods. In the paper, a fuzzy PID controller with fixed parameters is applied and then the optimum parameters of fuzzy PID controller are selected by Teaching-Learning optimization. For the fitness function of Teaching-Learning optimization, the performance index of PID controller is used. To verify the performances of the proposed method, we use a Maglev model and compare the proposed method with the performance of PID controller. The simulation results show that the proposed method is more effective than conventional PID controller.

Development of the Pneumatic Rotary Actuator for Marine Winch

  • Kim, D.-S;Lee, W.-H
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.354-360
    • /
    • 2004
  • It is well known that pneumatic actuators convert fluid power into mechanical power with a low efficiency. The pneumatic rotary actuators are used in not only marine winches. but also hoists, agitators, and excavators. The efficiency of pneumatic rotary actuators depends on several factors, such as type of actuator. speed, supply pressure. size and geometry of the actuator. This paper presents an analytical and experimental study of the performance of pneumatic rotary actuators. We investigate all the major aspects of the air flow through a pneumatic rotary actuator and points out the main causes of the low efficiency of the actuator. Therefore the design parameters which can lead to optimum performance are obtained.