• 제목/요약/키워드: Optimal power flow

검색결과 544건 처리시간 0.029초

부하역률 제약조건을 고려한 최적 급전 알고리즘 (The Optimal Power Flow Algorithm Considering Load Power Factor Limits)

  • 김광욱;조종만;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권9호
    • /
    • pp.494-499
    • /
    • 2004
  • This paper presents to compute the power economic dispatch, an optimal power flow (OPF) computation algorithm, considering the load power factor limits constraint in developed. Efficient reactive power planning enhances economic operation as well as system security. Accordingly, an adequate level of power factor limits for the load busesshould be evaluated for economic operation. In this paper, the ranges of acceptable load power factors are portrayed as bandwidths of load power factor expressed as a function of load level. The load power factor limits are included and described into the OPF's objective function. The method Proposed is applied to IEEE 26 bus system.

분산전원 계통 운용을 위한 3상 최적조류계산 (3 Phase Optimal Power Flow for the Operation of Distributed Generation Systems)

  • 김영곤;송화창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.482_483
    • /
    • 2009
  • This paper presents a method of finding the optimal operating point minimizing a given objective function with 3 phase power flow equations and operational constraints, called 3 phase optimal power flow. 3 phase optimal power flow can provide operation and control strategies for the distribution systems with distributed generation assets, which might be frequently in unbalanced conditions assuming that high penetration rate of renewable energy sources in the systems. As the solution technique, this paper adopts a standard particle swarm optimization (PSO).

  • PDF

Performance Comparison of Optimal Power Flow Algorithms for LMP Calculations of the Full Scale Korean Power System

  • Lee, Sungwoo;Kim, Wook;Kim, Balho H.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.109-117
    • /
    • 2015
  • This paper proposes the comparison results of various optimal power flow algorithms (OPF) to calculate the locational marginal prices (LMP) of the unreduced full scale Korean transmission system. Five different types of optimal power flow models are employed: Full AC OPF, Cubic AC OPF, Quadratic AC OPF, Linear AC OPF and DC OPF. As the results, full AC OPF and cubic AC OPF model provides LMP calculation results very similar to each other while the calculation time of cubic AC OPF model is faster than that of the Full AC OPF. Other simplified OPF models, quadratic AC OPF, linear AC OPF and DC OPF offer erroneous results even though the calculation times are much faster than the Full AC OPF and the Cubic AC OPF. Given the condition that the OPF models sometimes fail to find the optimal solution due to the severe complexity of the Korean transmission power system, the Full AC OPF should be used as the primary OPF model while the Cubic AC OPF can be a promising backup OPF model for the LMP calculations and/or real-time operation.

Optimal Siting of UPFC for Reducing Congestion Cost by using Shadow Prices

  • Lee, Kwang-Ho;Moon, Jun-Mo
    • KIEE International Transactions on Power Engineering
    • /
    • 제11A권4호
    • /
    • pp.21-26
    • /
    • 2001
  • As competition is introduced in the electricity supply industry, congestion becomes a more important issue. Congestion in a transmission network occurs due to an operating condition that causes limit violations on the transmission capacities. Congestion leads to inefficient use of the system, or causes additional costs (Congestion cost). One way to reduce this inefficiency or congestion cost is to control the transmission flow through the installation of UPFC (Unified Power Flow Controller). This paper also deals with an optimal siting of the UPFC for reducing congestion cost by using shadow prices. A performance index for an optimal siting is defined as a combination of line flow sensitivities and shadow prices. The proposed algorithm is applied to the sample system with a condition, which is concerning the quadratic cost functions. Test results show that the siting of the UPFC is optimal to minimize the congestion cost by the proposed algorithm.

  • PDF

전력시스템 안전도 향상을 위한 다기 UPFC의 최적 운전점 결정 (The Optimal Operating Points of Multiple UPFCs for Enhancing Power System Security Level)

  • 임정욱;문승일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권8호
    • /
    • pp.388-394
    • /
    • 2001
  • This paper presents how to determine the optimal operating points of Unified Power Flow controllers (UPFC) the line flow control of which can enhance system security level. In order to analyze the effect of these devices on the power system, the decoupled model has been employed as a mathematical model of UPFC for power flow analysis. The security index that indicates the level of congestion of transmission line has been proposed and minimized by iterative method. The sensitivity of objective function for control variables of and UPFC has been derived, and it represents the change in the security index for a given set of changes in real power outputs of UPFC. The proposed algorithm with sensitivity analysis gives the optimal set of operating points of multiple UPECs that reduces the index or increases the security margin and Marquart method has been adopted as an optimization method because of stable convergence. The algorithm is verified by the 10-unit 39-bus New England system that includes multiple FACTS devices. The simulation results show that the power flow congestion can be relieved in normal state and the security margin can be guaranteed even in a fault condition by the cooperative operation of multiple UPECs.

  • PDF

Methodology of Cyber Security Assessment in the Smart Grid

  • Woo, Pil Sung;Kim, Balho H.
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.495-501
    • /
    • 2017
  • The introduction of smart grid, which is an innovative application of digital processing and communications to the power grid, might lead to more and more cyber threats originated from IT systems. In other words, The Energy Management System (EMS) and other communication networks interact with the power system on a real time basis, so it is important to understand the interaction between two layers to protect the power system from potential cyber threats. This paper aims to identify and clarify the cyber security risks and their interaction with the power system in Smart Grid. In this study, the optimal power flow (OPF) and Power Flow Tracing are used to assess the interaction between the EMS and the power system. Through OPF and Power Flow Tracing based analysis, the physical and economic impacts from potential cyber threats are assessed, and thereby the quantitative risks are measured in a monetary unit.

Optimal Power Scheduling in Multi-Microgrid System Using Particle Swarm Optimization

  • Pisei, Sen;Choi, Jin-Young;Lee, Won-Poong;Won, Dong-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1329-1339
    • /
    • 2017
  • This paper presents the power scheduling of a multi-microgrid (MMG) system using an optimization technique called particle swarm optimization (PSO). The PSO technique has been shown to be most effective at solving the various problems of the economic dispatch (ED) in a power system. In addition, a new MMG system configuration is proposed in this paper, through which the optimal power flow is achieved. Both optimization and power trading methods within an MMG are studied. The results of implementing PSO in an MMG system for optimal power flow and cost minimization are obtained and compared with another attractive and efficient optimization technique called the genetic algorithm (GA). The comparison between these two effective methods provides very competitive results, and their operating costs also appear to be comparable. Finally, in this study, power scheduling and a power trading method are obtained using the MATLAB program.

최적 부하절체 알고리듬을 적용한 연속조류계산의 향상 (Improvement of Continuation Power Flow System Applying the Optimal Load Shedding Algorithm)

  • 송화창;이병준;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.899-901
    • /
    • 1998
  • Continuation power flow is a tool that can trace the path of the solution from the base stable solution. However, the base stable solution cannot be calculated when the initial system load is too large to operate at a stable operating point. This case is called as unsolvable case. This paper presents implementation of the optimal load shedding algorithm on continuation power flow. It performs steady-state analysis of power systems at unsolvable case that can occur in contingency analysis. Numerical simulation on 20-bus test system demonstrates that the continuation power flow applying the optimal load shedding algorithm is robust at solvable and unsolvable cases.

  • PDF

전력소비자 특성을 고려한 최적조류계산 (The Optimal Pourer Flow Considering the Characteristics of Electric Pourer Consumers)

  • 김문영;백영식;송경빈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권2호
    • /
    • pp.107-113
    • /
    • 2003
  • In a deregulated electric power market, a demand function to consider the characteristics of electric power consumers should be required. It is essential that the optimal power flow algorithm with object function of social welfare maximization using the demand function for a competitive electric power market is applied to resolve in a point of economic benefits as well as the security of power systems. Therefore, in this paper, we implement the optimization problem based on linear programming to consider the characteristics of electric power consumers using the demand function and analyze not only the nodal cost for generations and demands but also the variation of demands as a function of the characteristics of electric power consumers through numerical studies.

하이브리드 알고리즘을 응용하여 안전도제약을 만족시키는 최적전력조류 (Security Constrained Optimal Power Flow by Hybrid Algorithms)

  • 김규호;이상봉;이재규;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권6호
    • /
    • pp.305-311
    • /
    • 2000
  • This paper presents a hybrid algorithm for solving optimal power flow(OPF) in order to enhance a systems capability to cope with outages, which is based on combined application of evolutionary computation and local search method. The efficient algorithm combining main advantages of two methods is as follows : Firstly, evolutionary computation is used to perform global exploitation among a population. This gives a good initial point of conventional method. Then, local methods are used to perform local exploitation. The hybrid approach often outperforms either method operating alone and reduces the total computation time. The objective function of the security constrained OPF is the minimization of generation fuel costs and real power losses. The resulting optimal operating point has to be feasible after outages such as any single line outage(respect of voltage magnitude, reactive power generation and power flow limits). In OPF considering security, the outages are selected by contingency ranking method(contingency screening model). The OPF considering security, the outages are selected by contingency ranking method(contingency screening model). The method proposed is applied to IEEE 30 buses system to show its effectiveness.

  • PDF