• Title/Summary/Keyword: Optimal design and control

Search Result 2,066, Processing Time 0.03 seconds

A Study on Determining the Optimal Size of Bicycle Waiting Zone under Hook-Turn Operation (Hook-Turn 통행방식의 적정 자전거 대기공간 크기 결정에 관한 연구)

  • Lim, Guk-Hyun;Kim, Nam-Sun;Lee, Sang-Soo;Nam, Doohee;Kim, Jeong-Tae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.5
    • /
    • pp.42-53
    • /
    • 2016
  • This study aims to evaluate the performance of Hook-turn operation with various sizes of bicycle waiting zone(WZ) and to determine the optimal size of bicycle WZ under various traffic and control circumstances. An extensive simulation study was performed to examine bicycle and vehicle delay trends for given experimental design. Results showed that vehicle delay was insensitive to the size of waiting zone, but bicycle delay was reduced as the size of waiting zone increased in general. The delay performance indicated a similar trend between with RTOR and without RTOR operation, but vehicle delay slightly increased and bicycle delay slightly decreased without RTOR. Regarding to optimal waiting zone size, 6 WZ was recommended for general conditions with RTOR, but 9 WZ was recommended when bicycle left-turn volume was greater than 120 v/h. 6 WZ was recommended for general conditions without RTOR, but 12 WZ was recommended when bicycle left-turn volume was greater than 90 v/h.

Study of the Effective Fire and Smoke Control in Deep Underground Tunnel with Transverse Ventilation (대심도 터널 화재 시 균일배기 환기방식에서의 최적배연 연구)

  • Kim, Jong-Yoon;Lim, Kyung-Bum;Jeon, Yong-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.21-26
    • /
    • 2015
  • This study represents the effective fire and smoke control in the case of fire in deep underground tunnels, even if the exhaust system can be calculated, the optimal smoke capacity can be determined by establishing technical standards for the transverse ventilation system focusing on the design as a basis for deriving the parameters for utilization. Numerical analyses were performed using the FDS program as a function of the unsteady flow in a deep underground tunnel fire. The analysis results were calculated within 250 m smoke using an inside wind velocity of 0m/s when the capacity of smoke was exhausted, $80m^3/s$, whereas in case of an internal wind velocity of 3m/s, the capacity of smoke exhaust was $197.1m^3/s$, showing an approximately 2.5 fold increase.

Traffic Signal Control Methods for Functional Improvements in COSMOS (COSMOS 안정화를 위한 교통축 및 감응제어 방법연구)

  • 이승환;오영태;이상수
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.6
    • /
    • pp.31-43
    • /
    • 2002
  • Traffic signal control methods are suggested to improve the operational effectiveness of COSMOS system in Seoul. First. a method that improves progression of the corridor traffic flow within a common sub-area was explored. Applying this method, both frequency and magnitude of offset transition were reduced as compared to the existing method. In addition, the level of connection among neighboring corridors increased by applying the method, thus the qualify of progression was also improved. Second, a practical guideline on signal phase design was proposed to improve the efficiency of actuated operations for the left-turn movement. Last, a method for estimating optimal queue length parameters was surveyed and evaluated. An evaluation study was performed for the suggested methods through both field and simulation studies. Results showed that the proposed methods gave better performance than the existing methods. It is expected that the use of proposed methods can improve operational performance of COSMOS.

Servo Control of Hydraulic Motor using Artificial Intelligence (인공지능을 이용한 유압모터의 서보제어)

  • 신위재;허태욱
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.3
    • /
    • pp.49-54
    • /
    • 2003
  • In this paper, we propose a controller with the self-organizing neural network compensator for compensating PID controller's response. PID controller has simple design method but needs a lot of trials and errors to determine coefficients. A neural network control method does not have optimal structure as the parameters are pre-specified by designers. In this paper, to solve this problem, we use a self-organizing neural network which has Back Propagation Network algorithm using a Gaussian Potential Function as an activation function of hidden layer nodes for compensating PID controller's output. Self-Organizing Neural Network's learning is proceeded by Gaussian Function's Mean, Variance and number which are automatically adjusted. As the results of simulation through the second order plant, we confirmed that the proposed controller get a good response compare with a PID controller. And we implemented the of controller performance hydraulic servo motor system using the DSP processor. Then we observed an experimental results.

  • PDF

Design of Levitation Controller with Optimal Fuzzy PID Controller for Magnetic Levitation System (최적 퍼지PID제어기를 이용한 자기부상시스템의 부상제어기 설계)

  • Cho, Jae-Hoon;Kim, Yong-Tae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.3
    • /
    • pp.279-284
    • /
    • 2014
  • This paper proposes a optimum design method for the Fuzzy PID controller of magnetic levitation-based Rail-Guided Vehicle(RGV). Since an attraction type levitation system is intrinsically unstable, it is difficult to completely satisfy the desired performance through the methods designed by conventional controllers. In the paper, the Fuzzy PID controller with fixed parameters are applied and then the optimum parameters of fuzzy PID controller are selected by genetic algorithm. For the fitness function of genetic algorithm, the performance index of PID controller is used. To verify the performance of the proposed method, we used Matlab/simulink model of Maglev and compared the proposed method with the performance of PID controller. The simulation results show that the proposed method is more effective than conventional PID controller.

Electro-Magnetic Field Analysis for Optimal design of Magneto-Rheological Fluid Damper Core (자기점서유체 댐퍼 코어의 최적화 설계를 위한 전자기장 해석)

  • Song, June-Han;Son, Sung-Wan;Chun, Chong-Keun;Kwon, Young-Chul;Ma, Yang-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1511-1517
    • /
    • 2008
  • The magneto-rheological fluid expresses different cohesiveness according to the strength of the external electric current. The magneto-rheological fluid damper, which uses such characteristics of the fluid, generates shear force due to the fluid's cohesiveness. The core can be said to determine the magneto-rheological fluid damper's performance. This study uses the finite element analysis to compare the performance of different electromagnetic forces, which are affected by the shapes of the coil, and thus to find the optimum design for the core. In addition, as a step to construct a high-efficient damper, we suggest a type of damper that can control multiple coils and compares the performance of this damper and that of the standard damper by comparing the performance of their electro-magnetic fields.

Experimental Study on the Control Characteristics of Each Channel in a Semiconductor Chiller (반도체 공정용 칠러의 채널별 제어특성에 관한 실험적 연구)

  • Kim, Hyeon-Joong;Kwon, Oh-Kyung;Cha, Dong-An;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1285-1292
    • /
    • 2011
  • The characteristics of a semiconductor chiller system with EEV have been experimentally studied. Three experiments on temperature changes (increase and decrease), load variation, and control precision were conducted to investigate the operating characteristics of the semiconductor chiller. The power consumption was 8.9 kW during increase in temperature. The required time was 37.5 min for CH1 and 39.5 min for CH2. Moreover, the time required for falling temperature was 26.5 min. The control precision for partial load operation was relatively low compared to that of a full load operation. In addition, the CH2 equipped with a step motor showed better control precision. The power consumed by the chiller for process cooling water was 1.8 kW, which was one-half of that consumed during the refrigeration cycle. The objective of this study is to provide an optimal control guideline for the semiconductor chiller design.

Study on Optimization and Skin Permeation of PIT Nanoemulsion Containing α-Bisabolol (α-Bisabolol을 함유한 PIT Nanoemulsion의 최적화 및 피부흡수연구)

  • Kim, HuiJu;Yoon, Kyung-Sup
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1738-1751
    • /
    • 2020
  • The skin is divided into three parts: the epidermis, the dermis, and the subcutaneous fat, and the stratum corneum, which is located at the top of the epidermis, acts as a barrier that prevents drug delivery. Nanoemulsions are known to be effective in transdermal delivery of drugs through intercellular lipids because of their unique small particle size. In this study, phase inversion temperature (PIT) nanoemulsion containing α-bisabolol was optimized using response surface methodology (RSM) for effective skin absorption of α-bisabolol. As a preliminary experiment, the 25-2 fractional factorial design method and the 23 full factorial design method were performed. Box-Behnken design was performed based on the results of the factorial design method. The content of surfactant (6.3~12.6%), co-surfactant (5.2~7.8%) and α-bisabolol (0.5~5.0%) were used as factors, and the dependent variable was the particle size of the nanoemulsion. PIT nanoemulsion optimization was performed according to the RSM results, and as a result, the optimal nanoemulsion formulation conditions were predicted to be 10.4% surfactant content, 6.3% co-surfactant content, and 5.0% α-bisabolol content. As a result of the skin absorption test, the final skin absorption rate of the PIT nanoemulsion was 35.11±1.01%, and the final skin absorption rate of the general emulsion as a control was 28.25±1.69%, confirming that the skin absorption rate of the PIT nanoemulsion was better.

Energy Efficient Lighting Control Facilities Related to Daylight Levels (주광(晝光) 대등형 가변조명(可變照明) 제어설비의 적용 및 통합성능)

  • Kim, Jeong-Tai;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.8-15
    • /
    • 2006
  • To reduce costs and address other practical concern related to architectural lighting, we have been involved in various aspects of advanced daylighting design and control. If we look toward future building trends, we see that the advanced has already successfully deployed such complex lighting control systems. This paper takes a broad view of what advanced manufacturers have done to develop energy efficient lighting control technologies such as sensors, lumen maintenance, time of day scheduling, peak demand reduction and so forth. First of all strategies, daylighting controls would also need to be commissioned to respond to the specific daylighting signature of the zone. To translate the daylight in term of the amount of energy savings, an electric lighting system is designed and automatic on-off control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. The lighting analysis program, Lumen-Micro predicts the optimal layout of conventional fluorescent and incandescent lighting fixtures to meet the designed lighting level and calculates unit power density, which translates the demanded amount of lighting energy.

Design and Safety Control in Construction Stage of Prestressed Concrete Box Girder Bridge with Corrugated Steel Web (파형강판 PSC 박스거더 교량의 설계 및 시공중 안전관리)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.87-97
    • /
    • 2008
  • The Ilsun Bridge is the world's longest box girder bridge(801m) with corrugated steel webs and has the widest width($21.2{\sim}30.9m$: tri-cellular cross section) among these kinds of composite girder bridges. It has fourteen spans(50m, 10 at 60m, 50m, 2 at 50.5m) where twelve spans are erected by the incremental launching method and two spans by full staging method. Special topics related to the structural safety of prestressed concrete box girder bridge with corrugated steel web in construction stage and service were reviewed. Investigations focus on the span-to-depth ratio, shear stress of corrugated steel webs and optimization of tile length of steel launching nose. The span-to-depth ratio of Ilsun bridge has been found to be well-planned while the corrugated steel web has been designed highly conservative and it has been observed that the conventional nose-deck interaction equation do not fit well with corrugated steel web bridges. As a result, detailed construction stage analysis was performed to check the stress levels and the safety of preceding design conditions. Finally, from the design review of Ilsun bridge, this study suggests optimal design issues which should be of interest in designing a prestressed concrete box girder bridge with corrugated steel webs.