• 제목/요약/키워드: Optimal Placement

검색결과 363건 처리시간 0.03초

콜드조인트 지연시간에 따른 초고성능 콘크리트의 부착성능평가에 관한 실험적 연구 (An Experimental Study on Bonding Performance Evaluation of UHPC in Accordance with Delay Time of Cold Joints)

  • 장현오;김보석;장종민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.22-23
    • /
    • 2016
  • This study aims to derive the optimal condition that ensures the monolithicity of ultra-high performance concrete (UHPC), through the evaluation of bonding shear performance with respect to the time of cold joint occurrence during the placement. From the direct shear test, while the normalized bonding shear strength reduction of UHPC with the delay time of 15 minutes was the lowest at around 8%, a dramatic degradation of bonding shear performance was observed after 15 minutes. XRD analysis of the middle and surface sections was performed in order to analyze the composition of the thin film formed at the surface of UHPC, and as a result, the main ingredient appeared to be SiO2 from the XRD pattern of middle and surface sections, which is believed to be the result of the rising of SiO2-based filler, used as anadmixture in this study, toward the surface, due to its low specific gravity.

  • PDF

The Performance of Multistage Cooperation in Relay Networks

  • Vardhe, Kanchan;Reynolds, Daryl
    • Journal of Communications and Networks
    • /
    • 제17권5호
    • /
    • pp.499-505
    • /
    • 2015
  • We analyze the performance of multistage cooperation in decode-and-forward relay networks where the transmission between source and destination takes place in $T{\geq}2$ equal duration and orthogonal time phases with the help of relays. The source transmits only in the first time phase. All relays that can decode the source's transmission forward the source's message to the destination in the second time phase, using a space-time code. During subsequent time phases, the relays that have successfully decoded the source message using information from all previous transmitting relays, transmit the space-time coded symbols for the source's message. The non-decoding relays keep accumulating information and transmit in the later stages when they are able to decode. This process continues for T cooperation phases. We develop and analyze the outage probability of multistage cooperation protocol under orthogonal relaying. Through analytical results, we obtain the near-optimal placement strategy for relays that gives the best performance when compared with most other candidate relay location strategies of interest. For different relay network topologies, we also investigate an interesting tradeoff between an increased SNR and decreased spectral efficiency as the number of cooperation stages is increased. It is also shown that the largest multistage cooperation gain is obtained in the low and moderate SNR regime.

Factors Relating to the Quality of Care for Nursing Home Residents in Korea: Using the Delphi Method

  • Shin, Juh Hyun;Kim, Eun Mee;Lee, Ji Yeon
    • 대한간호학회지
    • /
    • 제49권6호
    • /
    • pp.783-794
    • /
    • 2019
  • Purpose: This study identified factors related to the quality of care in nursing homes, and elicited consensus opinions from experts on nursing homes. Methods: A Delphi questionnaire was developed based on a review of the literature using the keywords "nursing homes," "workforce," and "quality of care." A total of two Delphi surveys were conducted with 14 experts. The important and urgent factors related to the quality of care for nursing home residents emerged. Results: A consensus was achieved on the important and urgent factors relating to the quality of care. The related factors were grouped into four sections: Organizational Characteristics, Staffing Characteristics, the Long-Term Care Market and Legal and Policy Issues, and Nursing Processes. In total, 23 items were important factors and 26 items were urgent factors relating to the quality of care. In addition, the unanimous advocacy by the experts for increased hours per resident day for registered nurses (RNs, 41 minutes 59 seconds) was much higher than the current hours per resident day of RNs in Korea. Conclusion: To provide optimal care for residents in nursing homes in Korea, the mandatory and essential placement of RNs with professional knowledge and skills is paramount.

화학레이저 구동용 이젝터 시스템 개발 (III) - 고출력 화학레이저용 실물 크기의 이젝터 시스템 개발 및 성능 검증 - (Development of an Ejector System for Operating of Chemical Lasers (III) - Development and Performance Validation of a Full-Scale Ejector System for High Power Chemical Lasers -)

  • 김세훈;진정근;권세진
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.9-15
    • /
    • 2005
  • From the geometric parameter study, an optimal ejector design procedure of pressure recovery system for chemical lasers was acquired. For given primary flow reservoir conditions, an up-scaled ejector was designed and manufactured. In the performance test, secondary mass flow rate of 100g/s air was entrained satisfying the design secondary pressure, $40{\sim}50torr$. Performance validation of a supersonic ejector system along with an investigation of effects of supersonic diffuser was conducted. Placement of the diffuser at the secondary inlet further reduced diffuser upstream pressure to 7torr. Lastly, the duplicate of apparatus (air 500g/s secondary mass flow rate each) was built and connected in parallel to assess proportionality behavior on a system to handle larger mass flow rate. Test and comparison of the parallel unit demonstrated the secondary mass flow rate was proportional to the number of individual units that were brought together maintaining the lasing pressure.

클라이언트-서버 환경에서 슬롯 재사용 분산-큐 이중-버스의 공정성 제어를 위한 빌림과 반환 방식 (Borrowing and Returning Mechanism for Fairness Control of DQOB-SR on Clinet-Server Environments.)

  • 김정홍;권오석
    • 한국정보과학회논문지:정보통신
    • /
    • 제28권3호
    • /
    • pp.435-446
    • /
    • 2001
  • 본논문에서는 클라이언트-서버 환경에서 DQDB-SR 네트워크 대역폭을 모든 스테이션에게 공병하게 할당하기 위한 새로운 방식을 제안하였다. 제안한 방식은 클라이언트-서버 부하 패턴의 특성을 따르는 접근 임계값과 대역폭 빌림과 반환 방식을 사용하여 DQDB-SR에게 공평한 대역폭 제어 기능을 제공한다. 이를 구현하기 위해 DQDB-SR의 처리 용량을 최대로 하는 소거 노드의 위치와 접근 임계값을 구하였다. 제안한 방식이 과부하시 클라이언트-서버 부하 패턴에 대하여 네트워크 처리 능력을 저하시키지 않고 패킷 전송 성공률과 평균 패킷 전달 지연 시간에 있어 다른 공정성 제어 방식들 보다 우수하다는 것을 시뮬레이션 결과를 통하여 확인하였다.

  • PDF

Adaptive Control of Peak Current Mode Controlled Boost Converter Supplied by Fuel Cell

  • Bjazic, Toni;Ban, Zeljko;Peric, Nedjeljko
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.122-138
    • /
    • 2013
  • Adaptive control of a peak current mode controlled (PCM) boost converter supplied by a PEM fuel cell is described in this paper. The adaptive controller with reference model and signal adaptation is developed in order to compensate the deviation of the response during the change of the operating point. The procedure for determining the adaptive algorithm's weighting coefficients, based on a combination of the pole-zero placement method and an optimization method is proposed. After applying the proposed procedure, the optimal adaptive algorithm's weighting coefficients can be determined in just a few iterations, without the use of a computer, thus greatly facilitating the application of the algorithm in real systems. Simulation and experimental results show that the dynamic behavior of a highly nonlinear control system with a fuel cell and a PCM boost converter, can fairly accurately be described by the dynamic behavior of the reference model, i.e., a linear system with constant parameters.

외란 소거법을 이용한 강인한 전력 계통 안정화 장치 설계 (Design of Robust Power System Stabilizers Using Disturbance Rejection Method)

  • 김도우;윤기갑;김홍필;양해원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1195-1199
    • /
    • 1998
  • In this paper a design method of robust power system stabilizers is proposed by means of robust linear quadratic regulator design technique under power system's operating condition change, which is caused by inner structure uncertainties and disturbances into a power system. It is assumed that the uncertainties present in the system are modeled as one equivalent signal. In this connections an optimal LQR control input for disturbance rejection, the output feedback gain for eliminating the disturbance are calculated. In this case. PSS input signal is obtained on the basis of weighted ${\Delta}P_e$ and $\Delta\omega$. In order to stabilize the overall control of system. Pole placement algorithm is applied in addition. making the poles of the closed loop system to move into a stable region in the complex plane. Some simulations have been conducted to verify the feasibility of the proposed control method on a machine to infinite bus power system. From the simulation results validation of the proposed method could be achieved by comparisons with the conventional PSS with phase lag-lead compensation.

  • PDF

Design of piezoelectric transducer arrays for passive and active modal control of thin plates

  • Zenz, Georg;Berger, Wolfgang;Gerstmayr, Johannes;Nader, Manfred;Krommer, Michael
    • Smart Structures and Systems
    • /
    • 제12권5호
    • /
    • pp.547-577
    • /
    • 2013
  • To suppress vibration and noise of mechanical structures piezoelectric ceramics play an increasing role as effective, simple and light-weighted damping devices as they are suitable for sensing and actuating. Out of the various piezoelectric damping methods this paper compares mode based active control strategies to passive shunt damping for thin plates. Therefore, a new approach for the optimal placement of the piezoelectric sensors/actuators, or more general transducers, is proposed after intense theoretical investigations based on the Kirchhoff kinematical hypotheses of plates; in particular, modal and nilpotent transducers are discussed in detail. Based on the proposed distribution a discrete design for modal transducers is implemented, tested and verified on an experimental setup. For active control the modal sensors clearly identify the eigenmodes, whereas the modal actuators impose distributed eigenstrains in order to reduce the transverse plate vibrations. In contrast to the modal control, passive shunt damping works without requiring additional actuators or auxiliary power and can therefore act as an autonomous system, but it is less effective compensating the flexible vibrations. Exemplarily, an acryl glass plate disturbed by an arbitrary force initialized by a loudspeaker is investigated. Comparing the different methods their specific advantages are highlighted and a significant broadband reduction of the vibrations of up to -20dB is obtained.

Investigation of Design Methodology for Impressed Current Cathodic Protection Optimum System

  • Yao, Ping;Wu, Jianhua
    • Corrosion Science and Technology
    • /
    • 제7권4호
    • /
    • pp.197-200
    • /
    • 2008
  • In this paper, physical scale modeling was employed to identify the configurations of ICCP system and the electric field signatures. Computational boundary element modeling technique has been used to simulate the performance of the CP system and to predict the associated electric fields signatures. The optimization methods combined with the computer models and physical scale modeling will be presented here, which enable the optimum system design to be achieved both in terms of the location and current output of the anode but also in the location of reference electrodes for impressed current cathodic protection(ICCP) systems. The combined methodology was utilized to determine optimal placement of ICCP components (anodes and reference electrodes) and to evaluate performance of ICCP system for the 2%, 10% and 14% wetted hull coatings loss. The objective is to design the system to minimise the electric field while at the same time provide adequate protection for the ship. The results show that experimental scale modeling and computational modeling techniques can be used in concert to design an optimum ICCP system and to provide information for quickly analysis of the system and its surrounding environment.

Nonlinear control of a 20-story steel building with active piezoelectric friction dampers

  • Chen, Chaoqiang;Chen, Genda
    • Structural Engineering and Mechanics
    • /
    • 제14권1호
    • /
    • pp.21-38
    • /
    • 2002
  • A control algorithm combining viscous and non-linear Reid damping mechanisms has been recently proposed by the authors to command active friction dampers. In this paper, friction dampers and the proposed algorithm are applied to control the seismic responses of a nonlinear 20-story building. Piezoelectric stack actuators are used to implement the control algorithm. The capacity of each damper is determined by the practical size of piezoelectric actuators and the availability of power supply. The saturation effect of the actuators on the building responses is investigated. To minimize the peak story drift ratio or floor acceleration of the building structure, a practical sequential procedure is developed to sub-optimally place the dampers on various floors. The effectiveness of active friction dampers and the efficiency of the proposed sequential procedure are verified by subjecting the building structure to four earthquakes of various intensities. The performance of 80 dampers and 137 dampers installed on the structure is evaluated according to 5 criteria. Numerical simulations indicated that the proposed control algorithm effectively reduces the seismic responses of the uncontrolled 20-story building, such as inelastic deformation. The sub-optimal placement of dampers based on peak acceleration outperforms that based on peak drift ratio for structures subjected to near-fault ground motions. Saturation of piezoelectric actuators has adverse effect on floor acceleration.