• 제목/요약/키워드: Optimal PID Control

검색결과 248건 처리시간 0.032초

EHA(Electro-Hydrostatic Actuator) 위치제어 시스템의 모델링 및 제어 (Identification and Control of Position Control System for Electro-Hydraulic Actuator (EHA))

  • 박용호;박성환
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.69-77
    • /
    • 2011
  • In this paper, an optimal PID sliding mode controller is proposed for the position control of electro-hydrostatic actuator(ERA) systems with system uncertainties and saturation in the motor. An ERA prototype is developed and system modeling and parameter identification are executed. Then, optimal PID and optimal anti-windup PID controller are designed based on identified system model by using optimization toolbox in MA TLAB/Simulink and the performance of the two control systems are compared by experiment. It was found that the optimal anti-windup PID control system has better performance than the optimal anti-windup PID control system.

Intelligent Tuning of PID Controller With Disturbance Rejection Using Bacterial Foraging

  • Kim, Dong-Hwa;Cho, Jae-Hoon
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2004년도 추계학술대회 학술발표 논문집 제14권 제2호
    • /
    • pp.15-20
    • /
    • 2004
  • In this paper, design approach of PID controller with rejection function against external disturbance in motor control system is proposed using bacterial foraging based optimal algorithm. Up to the present time, PID Controller has been used to operate for AC motor drive because of its implementational advantages in practice and simple structure. However, it is not easy to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error in the industrial system with disturbance. To design disturbance rejection tuning, disturbance rejection conditions based on H$\_$$\infty$/ are illustrated and the performance of response based on the bacterial foraging is computed for the designed PID controller as ITSE (Integral of time weighted squared error). Hence, parameters of PID controller are selected by bacterial foraging based optimal algorithm to obtain the required response.

  • PDF

적응PID 슬라이딩 모드 제어기법을 적용한 EHA 시스템의 위치제어 (A Position Control of EHA Systems using Adaptive PID Sliding Mode Control Scheme)

  • 이지민;박성환;박민규;김종식
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.120-130
    • /
    • 2013
  • An adaptive PID sliding mode controller is proposed for the position control of electro-hydrostatic actuator(EHA) systems with system uncertainties and saturation in the motor. An EHA prototype is developed and system modeling and parameter identification are executed. Then, adaptive PID sliding mode controller and optimal anti-windup PID controller are designed and the performance and robustness of the two control systems are compared by experiment. It was found that the adaptive PID sliding mode control system has better performance and is more robust to system uncertainties than the optimal anti-windup PID control system.

기울기법을 이용한 최적의 PID 제어 학습법 (PID Learning Method using Gradient Approach for Optimal Control)

  • 임윤규;정병묵
    • 한국정밀공학회지
    • /
    • 제18권1호
    • /
    • pp.180-186
    • /
    • 2001
  • PID control is widely used in industrial areas, but it is not easy to tune PID gains for an optimal control. The proposed learning method is to tune PID gains using the gradient approach. We use two estimation functions in this method : one is an error function for tuning of PID gains, and the other is a performance measuring function for a completion of learning. This paper shows that optimal PID controllers can be acquired when this learning method is applied to 10 systems with different natural frequencies and damping ratios.

  • PDF

Robust Tuning of PID Controller With Disturbance Rejection Using Bacterial Foraging Based Optimization

  • Kim, Dong-Hwa;Cho, Jae-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1092-1097
    • /
    • 2005
  • In this paper, design approach of PID controller with rejection function against external disturbance in motor control system is proposed using bacterial foraging based optimal algorithm. Up to the present time, PID Controller has been used to operate for AC motor drive because of its implementational advantages in practice and simple structure. However, it is not easy to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error in the industrial system with disturbance. To design disturbance rejection tuning, disturbance rejection conditions based on $H_{\infty}$ are illustrated and the performance of response based on the bacterial foraging is computed for the designed PID controller as ITSE (Integral of time weighted squared error). Hence, parameters of PID controller are selected by bacterial foraging based optimal algorithm to obtain the required response

  • PDF

PID Type Iterative Learning Control with Optimal Gains

  • Madady, Ali
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권2호
    • /
    • pp.194-203
    • /
    • 2008
  • Iterative learning control (ILC) is a simple and effective method for the control of systems that perform the same task repetitively. ILC algorithm uses the repetitiveness of the task to track the desired trajectory. In this paper, we propose a PID (proportional plus integral and derivative) type ILC update law for control discrete-time single input single-output (SISO) linear time-invariant (LTI) systems, performing repetitive tasks. In this approach, the input of controlled system in current cycle is modified by applying the PID strategy on the error achieved between the system output and the desired trajectory in a last previous iteration. The convergence of the presented scheme is analyzed and its convergence condition is obtained in terms of the PID coefficients. An optimal design method is proposed to determine the PID coefficients. It is also shown that under some given conditions, this optimal iterative learning controller can guarantee the monotonic convergence. An illustrative example is given to demonstrate the effectiveness of the proposed technique.

SIL 기반 근접장 기록 시스템의 간극 제어를 위한 최적화된 PID 제어 알고리즘 성능평가 (Air-Gap Control Using Optimal PID Controller for SIL-Based Near-Field Recording System)

  • 신원호;김중곤;박노철;양현석;박영필;박경수
    • 정보저장시스템학회논문집
    • /
    • 제5권1호
    • /
    • pp.41-46
    • /
    • 2009
  • In SIL-based NFR servo systems, the residual error and the overshoot that are occurred in the process of the modes-witching servo which consists of approach, gap-control modes, and safety mode are reduced by using PID controller. However, the design method of conventional PID controller is not sufficient for the stable air gap control system. Therefore, the optimal PID controller using LQR manner is more useful to find the designed parameters of PID controller. In this paper, we show that the performance of the optimal PID controller is better than that of the lead-lag controller.

  • PDF

Performance Tuning Method of Inverse Optimal PID Control for Mechanical Systems

  • Choi, Young-Jin;Chung, Wan-Kyun;Youm, Young-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.62.1-62
    • /
    • 2001
  • This paper suggests an inverse optimal PID control design method for the trajectory tracking case of mechanical systems. Also, simple coarse/fine performance tuning laws are suggested based on the analysis for performance limitation of inverse optimal PID controller. Experimental results for a robot manipulator show the validity of our analysis for the performance tuning methods.

  • PDF

전력계통의 부하주파수 제어를 위한 신경회로망 전 보상 PID 제어기 적용 (Application of Neural Network Precompensated PID Controller for Load Frequency Control of Power Systems)

  • 김상효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.480-487
    • /
    • 1999
  • In this paper we propose a neural network precompensated PID(NNP PID) controller for load frequency control of 2-area power system. While proportional integral derivative(PID) controllers are used in power system they have many problems because of high nonlinearities of the power system So a neural network-based precompensation scheme is adopted into a conventional PID controller to obtain a robust control to the nonlinearities. The applied neural network precompen-sator uses an error back-propagation learning algorithm having error and change of error as inputand considers the changing component of forward term of weighting factor for reducing of learning time. Simulation results show that the proposed control technique is superior to a conventional PID controller and an optimal controller in dynamic responses about load disturbances. The pro-posed technique can be easily implemented by adding a neural network precompensator to an existing PID controller.

  • PDF

시간 지연이 있는 시스템에서의 PID 제어기 설계를 위한 루프 형성 기법 (A Loop Shaping Method of PID Controller for Time delay Systems)

  • 윤성오;서병설
    • 한국통신학회논문지
    • /
    • 제29권10C호
    • /
    • pp.1370-1377
    • /
    • 2004
  • 시간 지연이 있는 시스템에서의 최적 제어 이득은 시간 지연이 없는 시스템에서 설계된 최적 제어 이득과 지연 시간에 대하여 계산된 상태천이 함수의 곱의 형태로 나타난다. 따라서 시간 지연이 없는 시스템에 대하여 PID제어기의 영점들을 플랜트의 최대 극점에 근접하도록 가중치 요소 Q와 R을 선택하여 최적 제어 이득을 구하고, 시간 지연이 있는 2차 시스템에서의 상태천이 함수를 계산하여 시간 지연이 있는 시스템에서의 강인한 최적 PID 제어기 설계가 가능하도록 하였다.