• Title/Summary/Keyword: Optimal Operating Condition

Search Result 316, Processing Time 0.031 seconds

A study of Optimal Reconfiguration in Distribution Power System using Initial Operating Point (초기 운전점 선정을 통한 배전계통 최적 재구성에 관한 연구)

  • Seo, Gyu-Seok;Kim, Jung-Nyun;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.451-456
    • /
    • 2007
  • This paper presents a problem that reconfigure distribution power system using branch exchange method. Optimal reconfiguration problem calculates line loss, voltage condition about system states of all situations that become different according to line On/off status, and search for optimum composition of these. However, result is difficult to be calculated fast. Because radiated operation condition of system is satisfied using many connection and sectionalize switches in the distribution power system. Therefore, in this paper, optimization method for reducing system total loss and satisfying operating condition of radial and constraints condition of voltage is proposed using the fastest branch exchange. And optimal solution at branch exchange algorithm can be wrong estimated to local optimal solution according to initial operating state. Considering this particular, an initial operating point algorithm is added and this paper showed that optimal solution arrives at global optimal solution.

The Study on the Optimal Operating Conditions of Direct Charging Type Electrospray for Particulate Matter Collection (미세먼지 집진을 위한 직접 하전 방식 정전분무의 최적 동작 조건에 관한 연구)

  • Sugi Choi;Sunghwan Kim;Haiyoung Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.5
    • /
    • pp.474-481
    • /
    • 2023
  • This paper is an experimental study on the optimal operating conditions of direct charging type electrospray for particulate matter collection. To perform the research, a direct charging type electrospray visualization system was configured to photograph the spray shape of microdroplets, and experiments were performed with varying electrode distance, flow rate, and applied voltage, which are the main factors affecting the particulate matter collection efficacy. Through image processing, the total number of microdroplets according to each condition was analyzed, and the number of microdroplets with a diameter of 1.5 mm or less was confirmed. In addition, by calculating the number of microdroplets per power consumption according to the applied voltage, the optimal operating conditions were derived in terms of energy consumption efficacy, and the microdroplet size distribution was analyzed under the optimal operating conditions. As a result of the experiment, it was confirmed that the optimal operating condition was at a flow rate of 10 mL/min and a voltage of -20 kV in case of 5 mm electrode distance, and at a flow rate of 15 mL/min and a voltage of -30 kV in case of 100 mm electrode distance.

The Optimum Shape of Taper HTS Current Lead Having Partial Current Sharing Region (일부 전류분류 영역을 갖는 테이퍼 형상 전류도입선의 최적 형상에 대한 연구)

  • 허광수;설승윤
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.185-189
    • /
    • 2003
  • The purpose of this study is to obtain the optimal operating condition of conduction cooled taper shape high-temperature superconductor (HTS) current lead operated in current sharing mode. In our previous study, we discovered that the optimal operating condition of constant cross-section area HTS current lead is in the current sharing state, and in optimal condition, the temperature gradient at warm end is not zero. The analysis result of taper HTS current lead is quiet similar to the constant area HTS current lead. The minimum dissipation of taper HTS current lead is not influenced by taper angle, however the optimal operation condition is varied with taper angle.

  • PDF

A New Optimal Design Method of the Electronic Ballast for MHL with Stable Run-up Current (시동전류 제한을 통한 메탈헬라이드 램프용 안정기의 최적 설계)

  • Lim, Byoung-Loh;Jang, Mog-Soon;Lim, Ki-Seung;Park, Chong-Yeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.409-415
    • /
    • 2008
  • This paper proposed a new optimal design method of the electronic ballast with stable run-up current for Metal Halide lamp during the ignition condition. In order to avoid operation in the acoustic resonance frequency band and to supply the optimal ignition current without demage of inverter switching components during the ignition period, the values of the series inductor Ls, the series capacitor Cs, and the parallel capacitor Cp were determined by analysis of characteristics of inverter transfer function depend on Lamp operating power and resistance of ignition condition and steady state operating condition. For the prototype ballast for a 400W Metal Halide Lamp, experimental results are presented in order to validate the proposed method.

Development of an Optimal Cutting Condition Decision System by Neural Network (신경망을 이용한 최적절삭조건부여 시스템 개발)

  • Yang, Min-Yang;Kim, Hyun-Chul;Byun, Cheol-Woong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.9
    • /
    • pp.111-117
    • /
    • 2002
  • In most machining companies, operators decide the cutting condition, a pair of spindle speed (5) and table federate (F) by experience and subjective judgment. As cutting conditions are determined by operators' experience and ability, inconsistent cutting conditions are given in same operating conditions. The objective of this study is to develop the cutting condition decision system which utilizes shop data and predicts tool life by neural network and eventually leads to the optimal cutting condition. The production time per piece is considered for an optimization object. We will discuss the process of an optimal cutting condition decision by neural network. By this process, a series of shop data is stored. And neural network is constructed for prediction of tool life and the optimal cutting condition is recommended from a cutting condition decision system using the stored shop data. The results show that the developed system is rational in searching the optimal cutting conditions on job operations.

Study on Optimal Condition of Adaptive Maximum Torque Per Amp Controlled Induction Motor Drives

  • Kwon, Chun-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.231-238
    • /
    • 2014
  • Adaptive Maximum Torque Per Amp (Adaptive MTPA) control for induction motor drives seeks to achieve a desired torque with the minimum possible stator current regardless of operating points. This is favorable in terms of inverter operation and nearly optimal in terms of motor efficiency. However, the Adaptive MTPA control was validated only from the viewpoint of tracking a desired torque and was not shown that the desired torque is achieved with minimum possible stator current. This work experimentally demonstrates that optimal condition for Adaptive Maximum Torque Per Amp Control Strategy is achieved regardless of rotor resistance variation.

A Three-Dimensional Numerical Model for the Investing of Combustion Characteristics and Optimization of Operating Performances in Municipal Waste Incinerator (도시 폐기물 소각로의 연소특성 및 운전성능 최적화를 위한 3차원 수치모델링)

  • 전영남;정오진;송형운
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.2
    • /
    • pp.85-94
    • /
    • 2002
  • In this study, a 3-dimensional numerical model, has been developed applied for the investigation of combustion characteristics, and used to optimize operating conditions in MSW incinerator, in Gwangju. The model developed in this study has been verified by exacting both the predicted and the measured temperature in combustion chamber which has been operated to provide a reference condition. By predictive results, the Sangmoo incinerator has a good characteristics of combustion and low emission however after burning zone produced incomplete products, also probably because the supply of primary air was not enough. Parametric screening studies have been conducted to study optimal operating conditions. For the optimal combustion characteristics, operating conditions should be adjusted with the waste properties.

Optimal Operation Condition of Spray Drying Sorber for Simultaneous Removal of Acidic and Organic Gaseous Pollutants (산성 및 유기성 가스의 동시제거를 위한 준건식 세정시스템의 적정 운전 조건)

  • 백경렬;구자공
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.59-64
    • /
    • 2001
  • The effect of major operating parameters in spray drying sorber(=SDS) for automatic control for the simultaneous removal of acidic and organic gaseous pollutants from solid waste incinerator was performed. The field experiment was carried out in pilot scale test for the quantification of major operating parameters of hydrophilic and the hydrophobic pollutants. The removal efficiencies of $SO_2$and HCI in the 5wt% slurry condition were being increased with the increase of the stoichiometric ration which is the molecular ratio of lime to the pollutant concentration, and with the decrease of inflow flue gas temperature in the pilot SDS reactor. The removal efficiency along the height of spray drying sorber was closely related to the temperature profile, and more than 90% of total removal efficiency was achieved in an absorption region. For the removal of acidic gas the optimum operating condition considering the economics and a stable operation is the 5wt% of slurry concentration, 1.2 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. For the organic gases of benzene and toluene the removal efficiencies were 20-60% which is much lower than that of acidic gas. The best removal efficiency was obtained at 1.5 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. The organic\`s removal efficiency along the height of spray drying sorber was quite different from that of acidic gas, that is, more than 60% of the total removal efficiency for benzene and 90% of the total removal for toluene were achieved in the dried adsorption region, which was formed at the lower or exit part of the reactor.

  • PDF

A Study for the Optimal Operating Conditions of the Gas Turbine Based Combined Cycle Cogeneration Power Plant (가스터빈 복합 열병합 발전의 최적 운전조건에 관한 연구)

  • Cho, Young-Bin;Sohn, Jeong-Lak;Ro, Sung-Tack
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1582-1590
    • /
    • 2004
  • The purpose of this study is to show the existence of optimal operation conditions for minimum fuel consumption of the gas turbine based combined cycle cogeneration power plant. Optimal operational condition means the optimal distribution of the power generated by each gas turbine and the heat generated by each HRSG. Total fuel consumption is calculated by the sum of the fuels for gas turbines and supplementary boiler. Fuel consumption is calculated by numerical methods of energy equations which contain the power generated from gas and steam turbines, the heat generated by HRSG and the heat extracted from high pressure steam turbine.

Optimal Siting of UPFC for Reducing Congestion Cost by using Shadow Prices

  • Lee, Kwang-Ho;Moon, Jun-Mo
    • KIEE International Transactions on Power Engineering
    • /
    • v.11A no.4
    • /
    • pp.21-26
    • /
    • 2001
  • As competition is introduced in the electricity supply industry, congestion becomes a more important issue. Congestion in a transmission network occurs due to an operating condition that causes limit violations on the transmission capacities. Congestion leads to inefficient use of the system, or causes additional costs (Congestion cost). One way to reduce this inefficiency or congestion cost is to control the transmission flow through the installation of UPFC (Unified Power Flow Controller). This paper also deals with an optimal siting of the UPFC for reducing congestion cost by using shadow prices. A performance index for an optimal siting is defined as a combination of line flow sensitivities and shadow prices. The proposed algorithm is applied to the sample system with a condition, which is concerning the quadratic cost functions. Test results show that the siting of the UPFC is optimal to minimize the congestion cost by the proposed algorithm.

  • PDF