• 제목/요약/키워드: Optimal Capacity of PV systems

검색결과 13건 처리시간 0.03초

주택용 태양광발전시스템의 적정 용량 및 설치각 선정을 위한 최적화 모델 연구 (An Optimal Decision Model for Capacity and Inclining Angle of Residential Photovoltaic Systems)

  • 전정표;김광호
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1046-1052
    • /
    • 2010
  • In residential house, photovoltaic (PV) system among various alternatives in renewable energy system is the most efficient and feasible solution for reducing energy consumption and electricity cost. However, relatively high initial cost make people reluctant to install PV system in their houses. Therefore, in the initial state for PV system installation in the house, it is very important to decide proper capacity of the PV system considering the expected energy usage and solar energy supplying condition with the house. This paper proposes a novel optimization model for deciding appropriate capacity of the PV system for residential house. The objective function of the model is to minimize the annual cost including electricity bill, operation and maintenance cost, and annual fixed cost calculated from the initial installation cost based on capital recovery factor (CRF). The model also shows the optimal inclining angle of PV panels of the system. In this paper, we estimate the PV output using PVWATTS (PV simulator of Office of Energy Efficiency and Renewable Energy) and find optimal solutions by Sequential Quadratic Programming (SQP) method using MATLAB software. The proposed approach is finally applied to a residential model house in Gangneung, Gangwon-Do and verified its feasibility for adopting to PV system design for residential houses.

기후조건 및 실부하패턴을 고려한 태양광 시스템 최적 운전기법 (Photovoltaic System Operation Optimal Technique Considering Climate Condition and Residential Loads Pattern)

  • 문희성;최규영;김종수;이영국;이병국
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2385-2390
    • /
    • 2009
  • Based on the detailed analysis of output characteristics of PV array and residential load usage pattern, a design method to calculate optimal battery capacity for stand-alone PV generation systems is proposed. And also, according to power flow Actual irradiation and temperature data are analyzed to compose a PV array simulator and also six representative home appliances are electrically modeled for load simulator, along with 24hours usage pattern. The surplus and insufficient power can be calculated from the proposed simulation platform, so that selection of an optimal battery capacity can be possible. The theoretical analysis and design process will be explained, along with informative simulation results.

제로에너지건물 구축을 위한 PV + ESS 액티브 시스템의 최적운영개발에 관한 연구 (The Study of Optimal Operation Development of PV + ESS Active System for Zero Energy Building)

  • 우성민;문진철;안종욱;김용하
    • 한국태양에너지학회 논문집
    • /
    • 제39권5호
    • /
    • pp.53-63
    • /
    • 2019
  • This paper in order to efficiently operate zero energy buildings developed a methodology for optimal operation of PV + ESS active systems. This program consists of three steps. First step is PV optimal operation and second step is PV + ESS optimal operation. Third step is the analysis of the results by PV + ESS optimal operation. The optimal operation of PV + ESS was calculated by using Dynamic Programming (DP). Therefore, the optimal capacity and operating plan of PV + ESS in this study are calculated for electric load at building. This paper conducted case study to verify the validity of the developed algorithm. Also, the sensitivity analysis analyzed the effect of each variable on the optimal operation.

부하특성에 따른 복합발전시스템의 최적용량 설계 및 경제성 분석 (Optimal Capacity Design and Economic Evaluation of Hybrid Generation Systems Based on the Load Characteristics)

  • 임종환
    • 한국정밀공학회지
    • /
    • 제30권10호
    • /
    • pp.1103-1109
    • /
    • 2013
  • This paper presents an optimal capacity design of a Hybrid generation system based on economical evaluation for various loads. Optimal sizes of a standalone and grid connection wind- PV hybrid systems were designed for normal, residential and industrial loads using HOMER (Hybrid Optimization Model for Electronic Renewable). Their economical evaluation were performed and compared with a diesel generation system that covers the same loads. The results showed that the stand alone hybrid generation system can be more economical than a diesel generation system for long term operation.

태양광 에너지저장장치(ESS) 경제성 분석 및 최적 용량 평가 (Economy Analysis and Optimized Capacity Evaluation of Photovoltaic-Related Energy Storage System)

  • 이영훈;성태현
    • 한국산업융합학회 논문집
    • /
    • 제25권2_2호
    • /
    • pp.209-218
    • /
    • 2022
  • The purpose of this study is to analyze an economic assessment of PV-ESS systems based on the power generation performance data of solar power (PV) operating in domestic area, and to calculate the optimal capacity of the energy storage system. In this study, PVs in Gyeonggi-do, Jeollabuk-do, and Gyeongsangbuk-do were targeted, and PVs in this area were assumed to be installed on a general site, and the research was conducted by applying weights based on the facility's capacity. All the analysis was conducted using the actual amount of KPX transactions of PVs in 2019. In order to calculate the optimal capacity of PCS and BESS according to GHI, PV with a minimum/maximum/central value was selected by comparing the solar radiation before the horizontal plane between three years (2017-2019) of the location where PV was installed. As a result of the analysis, in Gyeonggi-do, if the REC weight decreases to 3.4 when there is no change in the cost of installing BESS and PCS, it is more economical to link BESS than PV alone operation of PV. In Jeollabuk-do, it was analyzed that if the REC weight was reduced to 3.6, it was more likely to link BESS than PV operated alone. In Gyeongsangbuk-do, it was analyzed that if the REC weight was reduced to 3.4, it was more likely to link BESS than PV operated alone.

태양열 집열기 기능을 갖는 BIPV 시스템의 응용 (Application of BIPV System Functioned as Solar Collector)

  • 민성혜;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.953-958
    • /
    • 2006
  • Perimeter zone has been reinforced by active systems, such as fan-coil units, because it causes an increase in heating and cooling loads, dew condensation in winter, or discomfort with cold-draft to residents in buildings, through poor insulation by light-weighed skin due to progressing multi-storied buildings and skyscrapers. However, because these active systems raise Its capacity so that fossil fuel is used as much as they are added, and ultimately, greenhouse effect is urged, we proposed BIPV system functioned as solar collector which can substitute active system. As an early stage, heat balance equation in steady-state by Fortran was used not only for pre-heating effect and electric power capacity during the day in winter, but also for electric power capacity during day in slimmer and sky radiation effect during night in summer. Especially, we should have considered shading on PV, since even a little bit of it makes the efficiency too low for the PV to work. Still, when the flux of pre-heated air was increased to make air-barrier, its temperature was not enough to make it because the speed of heat exchange was too fast to warm up the air, thus the capacity to meet the condition was evaluated, and electric power from PV was made used for it.

  • PDF

500kW급 태양광시험장 구축을 위한 최적설계에 관한연구 (A Study on optimal design for installion of 500kWp PV system testing ground)

  • 김의환;장주연;임희천
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.43-48
    • /
    • 2010
  • The performance of photovoltaic systems could be affected by various factors including installing conditions of modules, and their own efficiencies of solar cells and inverters. The installing conditions of a photovoltaic system including array types, tilting angles, azimuth, locations, quantities of sunshine, optimum angles of inclination and separated distance are analyzed using the SolarPro & Minitep SW simulation program, inorder to set up the installing conditions for improving system performance. The result from the simulation of the 500kWp PV system of Kochang with optimal installing conditions compared with normal conditions shows that the capacity factor has been increased from 11.02% to 12.06%.

3kW급 계통연계형 태양광발전시스템의 성능특성 비교분석에 관한 연구 (A Study on Performance Analysis of 3kW Grid-Connected PV Systems)

  • 소정훈;최주엽;유권종;정영석;최재호
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.9-15
    • /
    • 2004
  • 3kW grid connected PV(photovoltaic) systems have been constructed for evaluating and analyzing performance of PV system at FDTC(field demonstration test center) in Korea, PV systems installed in FDTC have been operating and monitored since November 2002. As climatic and irradiation conditions have been varied through long-term field test, data acquisition system has been constructed for measuring performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV systems has been evaluated and analyzed for component perspective(PV array and power conditioning system) and global perspective(system efficiency, capacity factor, and electrical power energy) by field test. By the results, it is very important to develop optimal design technology of grid connected PV system.

배터리 충전방식을 고려한 신재생에너지 기반 분산발전시스템의 용량선정 (Optimal Sizing of Distributed Power Generation System based on Renewable Energy Considering Battery Charging Method)

  • 김혜림;김동섭
    • 플랜트 저널
    • /
    • 제17권3호
    • /
    • pp.34-36
    • /
    • 2021
  • 기존의 중앙집중식 발전의 탈피와 에너지 전환 및 환경문제 인식에 의해 신재생에너지 기반의 분산발전시스템에 대한 관심이 증가하고 있다. 본 연구에서는 에너지저장장치로 납축전지를 사용하는 PV 및 WT 기반의 분산발전시스템을 모사하여 최적용량을 선정하였다. 기존 발전원으로 CHP를 채택하였으며 시스템의 최적용량은 기존발전원의 운전상황(전부하/부분부하)에 따라 MOGA를 통해 도출하였다. 또한 동일한 배터리 용량에서 배터리 충전방식이 달라지면 배터리의 수명이 달라지는 것을 확인하였다. 따라서 경제적이고 안정적인 전력수급을 위해서는 배터리 충전방식을 고려한 분산발전시스템의 용량선정이 수행되어야 한다.

대학건물의 전력소비패턴 분석을 통한 태양광, ESS 적정용량 산정 및 경제적 효과 분석 (Calculation of Photovoltaic, ESS Optimal Capacity and Its Economic Effect Analysis by Considering University Building Power Consumption)

  • 이혜진;최정원
    • 한국산업융합학회 논문집
    • /
    • 제21권5호
    • /
    • pp.207-217
    • /
    • 2018
  • Recently, the importance of energy demand management, particularly peak load control, has been increasing due to the policy changes of the Second Energy Basic Plan. Even though the installation of distributed generation systems such as Photovoltaic and energy storage systems (ESS) are encouraged, high initial installation costs make it difficult to expand their supply. In this study, the power consumption of a university building was measured in real time and the measured power consumption data was used to calculate the optimal installation capacity of the Photovoltaic and ESS, respectively. In order to calculate the optimal capacity, it is necessary to analyze the operation methods of the Photovoltaic and ESS while considering the KEPCO electricity billing system, power consumption patterns of the building, installation costs of the Photovoltaic and ESS, estimated savings on electric charges, and life time. In this study, the power consumption of the university building with a daily power consumption of approximately 200kWh and a peak power of approximately 20kW was measured per minute. An economic analysis conducted using these measured data showed that the optimal capacity was approximately 30kW for Photovoltaic and approximately 7kWh for ESS.