• 제목/요약/키워드: Optical simulation

검색결과 1,770건 처리시간 0.026초

Optical Spectroscopic Analysis of Muscle Spasticity for Low-Level Laser Therapy (LLLT)

  • Lee, Yeon-Ui;Lee, Sang-Kwan;Youn, Jong-In
    • Journal of the Optical Society of Korea
    • /
    • 제15권4호
    • /
    • pp.373-379
    • /
    • 2011
  • Current therapeutic methods for suppressing muscle spasticity are intensive functional training, surgery, or pharmacological interventions. However, these methods have not been fully supported by confirmed efficacy due to the aggravation of the muscle spasticity in some patients. In this study, a combined system was developed to treat with a low-level laser and to monitor the region of the treatment using an optical spectroscopic probe that measures oxygen saturation and deoxygenation during low-level laser therapy (LLLT). The evaluation of the wavelength dependence for LLLT was performed using a Monte Carlo simulation and the results showed that the greatest amount of heat generation was seen in the deep tissue at ${\lambda}$ = 830 nm. In the oxy- and deoxygenation measurements during and after the treatment, oxygen-Hb concentration was significantly increased in the laser-irradiated group when compared to the control group. These findings suggest that LLLT using ${\lambda}$ = 830 nm may be of benefit in accelerating recovery of muscle spasticity. The combined system that we have developed can monitor the physiological condition of muscle spasticity during the laser treatment in real time and may also be applied to various myotonia conditions such as muscle fatigue, back-pain treatment/monitoring, and ulcer due to paralysis.

The optical design method for dual-mode transflective LCD

  • Hsieh, C.H.;Sha, Y.A.;Su, P.J.;Chang, K.H.;Chen, C.H.;Hsiao, C.C.;Shiu, J.W.;Fuh, S.Y.;Cheng, W.Y.;Liao, Y.C.;Yang, J.C.;Lo, K.L.;Lee, D.W.;Lee, K.C.;Chang, Y.P.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1529-1532
    • /
    • 2006
  • Depending on the optical design method, a novel dual-mode transflective LCD with proper LC material and optical films was developed. The design increased the optical transmittance and the reflectivity of dual-mode transflective LCDs with the proper parameters of cell gap, alignment layer and optical films. These parameters were evaluated by computer simulation. The simulation results also revealed that the transmissive and reflective states presented similar performance in the transflective LCDs.

  • PDF

Full-HD LCOS의 이웃한 픽셀 사이의 Trench구조 변화에 따른 전기광학적 특성 분석 (Electro-optical Characteristics of Full-HD LCOS Depending on the Trench Structure between Adjacent Pixels)

  • 손홍배;김민석;강정원
    • 반도체디스플레이기술학회지
    • /
    • 제8권2호
    • /
    • pp.59-62
    • /
    • 2009
  • In order to check the validation of LC simulation, 0.7 inch LCOS panel in full-HD resolution was fabricated and used for the electro-optical measurement. Compared the measured data with the calculated data, the averaged difference was 1.72% under 0 ~ +6 V bias on pixel electrode. To improve the optical characteristics of full-HD LCOS panel, the planar structure and trench structures (0.1 um, 0.2 um and 0.3 um-in-depth) between adjacent pixels were investigated with LC simulation. The planar structure showed the higher reflectance and faster reflectance-voltage response time than the trench structure. The optical fill factor and contrast ratio of planar structure were also higher than those of trench structures. As compared 1 um-in-depth trench structure resembled to the real structure with the planar structure, the optical fill factor was improved by 1.15% and the contrast ratio was improved by 5.26%. In order to minimize the loss of luminance and contrast ratio, the planar structure need to be applied between adjacent pixels.

  • PDF

광 지연선로를 이용한 스퀸팅이 없는 위상배열 안테나의 근접장 서브파장 포커싱 (Squint-less Phased Array Antenna Near-field Subwavelength Focusing with True-time Optical Delay Line)

  • 정영진
    • 한국광학회지
    • /
    • 제30권3호
    • /
    • pp.94-100
    • /
    • 2019
  • 본 연구에서는 광 지연선로를 이용한 스퀸팅(squinting)이 없는 위상배열 안테나의 근접장 미세파장 포커싱(subwavelength focusing)을 디자인하고 전산모사를 통해 검증하였다. 마이크로파 파장에서 위상배열 안테나의 수치적 계산을 위해 호이겐스-프레넬(Huygens-Fresnel) 원리를 적용하였다. 제안하는 시스템은 첩 광섬유 격자(chirped fiber grating)에 기반한 광 지연선로를 이용하여 빔 스퀸팅이 생기지 않는다는 것을 전산모사를 통해 확인하였다. 그리고 개별 안테나의 배열은 광학렌즈시스템에서 회절 소자로 간주할 수 있음에 착안해 높은 개구율(numerical aperture)을 구현하고 미세파장 포커싱을 얻었다. 또한, 위상배열 안테나의 안테나 사이 거리를 반파장 이하로 줄여 사이드 로브를 억제할 수 있음을 보였다.

Study of Stray-light Analysis and Suppression Methods for the Spectroscopic System of a Solar-radiation Observer Instrument

  • Zheng, Ru;Liu, Bo;Wang, Lingyun;Gao, Yue;Li, Guangxi;Li, Changyu
    • Current Optics and Photonics
    • /
    • 제5권3호
    • /
    • pp.220-228
    • /
    • 2021
  • To improve the measurement accuracy of a solar-radiation observer instrument, aiming at the problem of multiorder-stray-light interference caused by the diffraction of the flat-field concave grating in the spectroscopic system, straylight suppression methods for different forms of optical traps are studied. According to the grating surface-scattering distribution-function model, the bidirectional scattering distribution function (BSDF) of a dust-polluted surface and the flat-field concave grating's transition area of the spectroscopic system is calculated, and a Lyot stop with blade baffle is designed to suppress this kind of stray light. For diffraction multiorder stray light, based on the theory of light-energy transmission, a design for precise positioning of the trench optical trap is proposed. The superiority of the method is verified through simulation and actual measurement. The simulation results show that in a spectroscopic system approximately 160 mm × 140 mm × 80 mm in size, the energy of the stray light is reduced by one order of magnitude by means of the trench optical trap and Lyot stop, and the number of beams is reduced from 5664 to 1040. The actual measurements show that the stray-light-suppression efficiency is about 69.4%, which is effective reduction of the amount of stray light.

The Effect of an Optical Clearing Agent on Tissue Prior to 1064-nm Laser Therapy

  • Youn, Jong-In
    • Medical Lasers
    • /
    • 제10권3호
    • /
    • pp.146-152
    • /
    • 2021
  • Background and Objectives Although lasers have been widely applied in tissue treatment, the light penetration depth in tissues is limited by the tissue turbidity and affected by its absorption and scattering characteristics. This study investigated the effect of using an optical clearing agent (OCA) on tissue to improve the therapeutic effect of 1064 nm wavelength laser light by reducing the heat generated on the skin surface and increasing the penetration depth. Materials and Methods A diode laser (λ = 1064 nm) was applied to a porcine specimen with and without OCA to investigate the penetration depth of the laser light and temperature distribution. A numerical simulation using the finite element method was performed to investigate the temperature distribution of the specimen compared to ex-vivo experiments using a thermocouple and double-integrating sphere to measure the temperature profile and optical properties of the tissue, respectively. Results Simulation results showed a decrease in tissue surface temperature with increased penetration depth when the OCA was applied. Furthermore, both absorption and scattering coefficients decreased with the application of OCA. In ex-vivo experiments, temperatures decreased for the tissue surface and the fat layer with the OCA, but not for the muscle layer. Conclusion The use of an OCA may be helpful for reducing surface heat generation and enhance the light penetration depth in various near-infrared laser treatments.

Covered Microlens Structure for Quad Color Filter Array of CMOS Image Sensor

  • Jae-Hyeok Hwang;Yunkyung Kim
    • Current Optics and Photonics
    • /
    • 제7권5호
    • /
    • pp.485-495
    • /
    • 2023
  • The pixel size in high-resolution complementary metal-oxide-semiconductor (CMOS) image sensors continues to shrink due to chip size limitations. However, the pixel pitch's miniaturization causes deterioration of optical performance. As one solution, a quad color filter (CF) array with pixel binning has been developed to enhance sensitivity. For high sensitivity, the microlens structure also needs to be optimized as the CF arrays change. In this paper, the covered microlens, which consist of four microlenses covered by one large microlens, are proposed for the quad CF array in the backside illumination pixel structure. To evaluate the optical performance, the suggested microlens structure was simulated from 0.5 ㎛ to 1.0 ㎛ pixels at the center and edge of the sensors. Moreover, all pixel structures were compared with and without in-pixel deep trench isolation (DTI), which works to distribute incident light uniformly into each photodiode. The suggested structure was evaluated with an optical simulation using the finite-difference time-domain method for numerical analysis of the optical characteristics. Compared to the conventional microlens, the suggested microlens show 29.1% and 33.9% maximum enhancement of sensitivity at the center and edge of the sensor, respectively. Therefore, the covered microlens demonstrated the highly sensitive image sensor with a quad CF array.

A New Full-Aperture Reflective Null Measuring Method for Conformal Dome

  • Yan, Xudong;Wang, Junhua;Xu, Min
    • Journal of the Optical Society of Korea
    • /
    • 제20권1호
    • /
    • pp.174-179
    • /
    • 2016
  • In this paper, a novel full-aperture reflective null measuring method is proposed to detect the transmission wavefront of a conformal dome surface. An aspheric compensator is designed and placed behind the dome to reflect the aspheric testing wave back to the same path. To ensure the feasibility of this method, tolerance analysis is conducted, and guidance to assembly is given accordingly. The accuracy of this method is verified to be λ/30 (λ =3.39 μm) by Monte Carlo algorithm. In addition, the influence of different error factors, including the thickness error and decenter error of the dome, on the testing wavefront is analyzed. Simulation and experiment indicate that this method is practical and simple, and can measure the conformal domes precisely and comprehensively.

다중빔을 이용한 광 저장 장치에 관한 연구 (Study on a Optical Storage Device Based on Multi-beam)

  • 이정현;한창수;김수현;곽윤근
    • 한국정밀공학회지
    • /
    • 제16권4호통권97호
    • /
    • pp.64-70
    • /
    • 1999
  • A new multi-beam optical system is presented on the grounds of tri-positioning systems in this paper. The system has been developed to improve the data transfer rate for the optical disk system. The actuating system is composed of a tracking and focusing actuating system basically and a newly developed beam rotating actuator. The beam rotating actuator is employed in a multi-beam optical system to trace more than one track simultaneously. The multi-beam optics is established through the optical simulation and several experimental trials. The differential phase tracking method is used in the tracking error signal detection based on the only one beam spot. We also analyze the characteristics of multi-beam optical system. The experimental result shows that the multi-beam positioning system has performance adequate to the multi-beam optical disk system.

  • PDF