• Title/Summary/Keyword: Optical sensitivity

Search Result 875, Processing Time 0.028 seconds

X-Ray, UV and Optical Observations of Classical Cepheids: New Insights into Cepheid Evolution, and the Heating and Dynamics of Their Atmospheres

  • Engle, Scott G.;Guinan, Edward F.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.2
    • /
    • pp.181-189
    • /
    • 2012
  • To broaden the understanding of classical Cepheid structure, evolution and atmospheres, we have extended our continuing secret lives of Cepheids program by obtaining XMM/Chandra X-ray observations, and Hubble space telescope (HST) / cosmic origins spectrograph (COS) FUV-UV spectra of the bright, nearby Cepheids Polaris, ${\delta}$ Cep and ${\beta}$ Dor. Previous studies made with the international ultraviolet explorer (IUE) showed a limited number of UV emission lines in Cepheids. The well-known problem presented by scattered light contamination in IUE spectra for bright stars, along with the excellent sensitivity & resolution combination offered by HST/COS, motivated this study, and the spectra obtained were much more rich and complex than we had ever anticipated. Numerous emission lines, indicating $10^4$ K up to ${\sim}3{\times}10^5$ K plasmas, have been observed, showing Cepheids to have complex, dynamic outer atmospheres that also vary with the photospheric pulsation period. The FUV line emissions peak in the phase range ${\varphi}{\approx}0.8-1.0$ and vary by factors as large as $10{\times}$. A more complete picture of Cepheid outer atmospheres is accomplished when the HST/COS results are combined with X-ray observations that we have obtained of the same stars with XMM-Newton & Chandra. The Cepheids detected to date have X-ray luminosities of log $L_X{\approx}28.5-29.1$ ergs/sec, and plasma temperatures in the $2-8{\times}106$ K range. Given the phase-timing of the enhanced emissions, the most plausible explanation is the formation of a pulsation-induced shocks that excite (and heat) the atmospheric plasmas surrounding the photosphere. A pulsation-driven ${\alpha}^2$ equivalent dynamo mechanism is also a viable and interesting alternative. However, the tight phase-space of enhanced emission (peaking near 0.8-1.0 ${\varphi}$) favor the shock heating mechanism hypothesis.

Optical Characteristics of Plasmonic Nano-structure Using Polystyrene Nano-beads (폴리스티렌 나노 비드를 이용한 플라즈모닉 나노 구조체의 광학 특성)

  • Kim, Doo Gun;Jung, Byung Gue;Kim, Hong-Seung;Kim, Tae-Ryong;Kim, Seon-Hoon;Ki, Hyun-Chul;Kim, Tae-Un;Shin, Jae Cheol;Choi, Young-Wan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.4
    • /
    • pp.244-248
    • /
    • 2015
  • We proposed and demonstrated the double layered metallic nano-hole structure using polystyrene beads process to enhance the sensitivity of surface plasmon resonance (SPR). The double layered SPR structures are calculated using the finite-difference time-domain (FDTD) method for the width, thickness, and period of the metallic nano-hole structures. The thickness of the metal film and the metallic nano-hole is 30 and 20 nm in the 214 nm wide nano-hole size, respectively. The double layered SPR structures are fabricated with monolayer polystyrene beads of 420 nm wide. The sensitivities of the conventional SPR sensor and the double layered SPR sensor are obtained to 42.2 and 52.1 degree/RIU, respectively.

Investigation on the Geometric Pattern of Domestic Golf Wear - Focusing on the $2002's\;{\sim}\;2006's$ - (국내 골프웨어에 활용된 기하학적 패턴 분석 - 2002년 S/S${\sim}$2006년 F/W -)

  • Im, Ji-Wan;Park, Meeg-Nee
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.8
    • /
    • pp.75-88
    • /
    • 2007
  • Nowadays, geometrical form expressed on costume is recognizing as a part of modeling art, at the same time is working to develop it. Also the geometrical form is affording the coinciding lifestyle and sensitivity of customers keeping their pace. As a result, our study is researching on the geometrical form that is used in the pattern, silhouette, and detail of the costume to show the texture in sense of touch and the effect of optical illusion used in variable designs, in order to present the expansion our capability of infinite development included in the study of costume. Specially, geometrical form included in sports wear is very effective since the geometrical form includes short and simple beauty as well as practical design. Thus, this study is wishing to know if satisfying the practical and psychological urge of present human beings may be applied to the golf wear market, which is a type of sport that geometrical form is sent in the fastest way in domestic market. Also we are urged to know what type of design technique is the geometrical form nowadays used and changed to discriminate the artificial commerce and improve the identity of such unique brand. The source of this thesis is wishing to investigate the specialization and the most effective geometrical shape and preference of each type in domestic golf wear goods that applied geometrical goods in $2002{\sim}2006$ and analyze its way of expression.

Optical Voltage and Current Sensor Using Electrooptic and Magnetooptic Effects of BSO and ZnSe Crystals (BSO와 ZnSe의 전기/자기광학효과를 이용한 광 전압 및 전류센서)

  • Park, Seo-Yeon;Chung, Woo-Gee;Kwon, Won-Hyun;Choi, Pyung-Suk;Park, Han-Kyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.4
    • /
    • pp.106-112
    • /
    • 1989
  • In this paper, voltage and current measurement systems which utilize linear electrooptic and magnetooptic effects of BSO and ZnSe crystals are theoretically analyzed and experimented. In experiments, BSO voltage sensor has maximum 2% error within the applied voltage of 500V, and ZnSe current sensor has maximum 4% error within 1,000 A range. And temperature dependences of sensitivity for voltage and current in the temperature range from $-5^{circ}C\;to\;60^{circ}$C are measured +1.8% and 2.73%, respectively.

  • PDF

A Study on Depth Information Acquisition Improved by Gradual Pixel Bundling Method at TOF Image Sensor

  • Kwon, Soon Chul;Chae, Ho Byung;Lee, Sung Jin;Son, Kwang Chul;Lee, Seung Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.1
    • /
    • pp.15-19
    • /
    • 2015
  • The depth information of an image is used in a variety of applications including 2D/3D conversion, multi-view extraction, modeling, depth keying, etc. There are various methods to acquire depth information, such as the method to use a stereo camera, the method to use the depth camera of flight time (TOF) method, the method to use 3D modeling software, the method to use 3D scanner and the method to use a structured light just like Microsoft's Kinect. In particular, the depth camera of TOF method measures the distance using infrared light, whereas TOF sensor depends on the sensitivity of optical light of an image sensor (CCD/CMOS). Thus, it is mandatory for the existing image sensors to get an infrared light image by bundling several pixels; these requirements generate a phenomenon to reduce the resolution of an image. This thesis proposed a measure to acquire a high-resolution image through gradual area movement while acquiring a low-resolution image through pixel bundling method. From this measure, one can obtain an effect of acquiring image information in which illumination intensity (lux) and resolution were improved without increasing the performance of an image sensor since the image resolution is not improved as resolving a low-illumination intensity (lux) in accordance with the gradual pixel bundling algorithm.

Polymer Waveguide Based Refractive Index Sensor Using Polarimetric Interference (편광 간섭을 이용한 광도파로 기반의 표면 굴절률 센서)

  • Son, Geun-Sik;Kwon, Soon-Woo;Kim, Woo-Kyung;Yang, Woo-Seok;Lee, Hyung-Man;Lee, Han-Young;Lee, Sung-Dong;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.193-198
    • /
    • 2008
  • A novel refractive index sensor, which consists of polymer channel waveguide overlaid with $TiO_2$ thin film, is demonstrated. To evaluate the fabricated sensor, we measured the polarimetric interference induced by concentration change of injected glycerol solution. Our experimental results show that thicker $TiO_2$ film improves the sensitivity of the polarimetric interferometer. For the fabricated waveguide with a 20 nm thick $TiO_2$ film, the measured index change to lead phase variation of $2{\pi}$ is $1.8{\times}10^{-3}$.

Biochip System for Environmental Monitoring using Nanobio Technology (나노바이오기술을 이용한 환경모니터링용 바이오칩 시스템)

  • Kim, Young-Kee;Min, Jun-Hong;Oh, Byung-Keun;Choi, Jeong-Woo
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.378-386
    • /
    • 2007
  • Bio-sensing devices, which are basically integrated and miniaturized assay systems consisted of bioreceptor and signal transducer, are advantageous in several ways. In addition to their high sensitivity, selectivity, simplicity, multi-detection capability, and real time detection abilities, they are both very small and require relatively inexpensive equipments. Two core technologies are required to develop bio-sensing devices; the fabrication of biological receptor module (both of receptor development and immobilisation of them) and the development of signal transducing instruments containing signal generation technique. Various biological receptors, such as enzymes, DNA/RNA, protein, and cell were tried to develop bio-sensing devices. And, the signal transducing instruments have also been extensively studied, especially with regard to electrochemical, optical, and mass sensitive transducers. This article addresses bio-sensing devices that have been developed in the past few years, and also discusses possible future major trends in these devices.

A fiber optic surface plasmon resonance (SPR) sensorusing cyclic olefin copolymer (COC) polymer prism (Cyclic olefin copolymer (COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명 (SPR) 바이오 센서)

  • Yun, Sung-Sik;Lee, Soo-Hyun;Ahn, Chong-H.;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.369-374
    • /
    • 2008
  • A novel fiber optic surface plasmon resonance (SPR) sensor using cyclic olefin copolymer (COC) prism with the spectral modulation is presented. The SPR sensor chip is fabricated using the SU-8 photolithography, Ni-electroplating and COC injection molding process. The sidewall of the COC prism is partially deposited with Au/Cr (45/2.nm thickness) by e-beam evaporator, and the thermal bonding process is conducted for micro fluidic channels and optical fibers alignment. The SPR spectrum for a phosphate buffered saline (0.1.M PBS, pH.7.2) solution shows a distinctive dip at 1300.nm wavelength, which shifts toward longer wavelength with respect to the bovine serum albumin (BSA)concentrations. The sensitivity of the wavelength shift is $1.16\;nm{\cdot}{\mu}g^{-1}{\cdot}{\mu}l^{-1}$. From the wavelength of SPR dips, the refractive indices (RI) of the BSA solutions can be theoretically calculated using Kretchmann configuration, and the change rate of the RI was found to be $2.3{\times}10^{-5}RI{\cdot}{\mu}g^{-1}{\cdot}l^{-1}$. The realized fiber optic SPR sensor with a COC prism has clearly shown the feasibility of a new disposable, low cost and miniaturized SPR biosensor for biochemical molecular analyses.

Characteristics of Se/CdS Heterojunction Fabricated by EBE Method (EBE법으로 제작한 Se/CdS 이종접합의 특성)

  • Park, Gye-Choon;Cho, Jae-Cheol;Yoo, Yong-Tek
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.87-94
    • /
    • 1993
  • CdS and Se thin films were deposited on slide glass by EBE method respectively and surface morphology, crystal structure, electrical and optical properties were investigated by substrate temperature and annealing. The deposited CdS film was well fabricated with cubic structure at substrate temperature of $150^{\circ}C$. Se film was deposited with noncrystal structure until substrate temperature of $100^{\circ}C$, but Se film was grown with monoclinic structure at substrate temperature of $150^{\circ}C$. And so, after annealing at $150^{\circ}C$ for 15min, noncrystalline Se was proved to be hexagonal structure. Finally, the maximum output of Se/CdS heterojunction at 5000 lux was 4 $mW/cm^{2}$ and maximum spectral sensitivity was represented at 585nm.

  • PDF

Measurement of Inertia of Turbocharger Rotor in a Passenger Vehicle (승용차용 터보과급기 로터의 관성모멘트 측정)

  • Chung, Jin Eun;Lee, Sangwoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • The turbocharger is an essential component to realize the engine down-sizing. The moment of inertia of turbocharger rotor is an important parameter with respect to acceleration performance of the vehicle. It can be calculated from the CAD software based the geometry data and the material properties. But the accurate value of the inertia of turbocharger rotor must be measured through the experimental method. In this study, the measurement of moment of inertia of turbocharger rotor for 2.0 L spark-ignition engine was carried out. First, an experimental equipment using a trifilar method was designed and fabricated. Some optical devices, that is, photo sensor, counter, convex lens, etc, were used to increase the accuracy of the measurement. Second, error sensitivity for the equipment was analyzed. The error of period time and the radius can give big affects to the accuracy of the moment of inertia. When the amount of error of these two were each 1.0 %, maximum error of the moment of inertia was under 3.0 %. Third, the calibration for the equipment was performed using a calibration rotor which has similar shape to turbine rotor but simple. Calculated value from CAD software and measured one for the calibration rotor were compared. The total error of the equipment and the measurement is about 1.3 %. This result shows that the equipment can give the good result with resonable accuracy. Finally the moment of inertia of the turbine rotor and compressor wheel were measured. The coefficient of variations, the ratio of standard deviation to mean value, were reasonably small at 0.57 % and 0.73 % respectively. Therefore this equipment is suitable for the measurement of the moment of inertia of the turbine rotor and compressor wheel.