• Title/Summary/Keyword: Optical scanner

Search Result 165, Processing Time 0.027 seconds

A Study on Optical Coherence Tomography System by Using the Optical Fiber (광섬유를 이용한 광영상단층촬영기 제작에 관한 연구)

  • 양승국;박양하;장원석;오상기;이석정;김기문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.34-40
    • /
    • 2004
  • In this paper, we have studied the OCT(Optical Coherence Tomography) system which has been advantages of high resolution, 2-D cross-sectional images, low cost and small size configuration. The characteristics of light source determine the resolution and coherence length. The light source has a commercial SLD with a central wavelength of 1,285 ill11, 35.3 nm(FWHM). The optical delay line is necessary to make equal with the optical path length to scattered light or reflected light from a sample. In order to make equal the optical path length, the stage that is attached to a reference mirror is controled by a step motor. And the interferometer is configured with the Michelson interferometer by using a single mode fiber, and the scanner can be focused on the sample by using a reference ann Also, the 2-dimension cross-sectional images were measured with scanning the transverse direction of the sample by using a step motor. After detecting the internal signal of lateral direction, a scanner is moved to obtain the cross-sectional image of 2-dimension by using step motor. A photodiode, which has high detection sensitivity and excellent noise characteristics has been used. The detected small signal has a noise and interference. After filtering and amplifying the signal, the output signal is demodulated the waveform And then, a cross-sectional image is seen through converting this signal into a digitalized signal by using an AID converter. The resolution of the sample is about 30${\mu}{\textrm}{m}$, which corresponds to the theoretical resolution. Also, the cross-sectional images of onion cells were measured in real time scheme.

Comparison of digital models generated from three-dimensional optical scanner and cone beam computed tomography (3차원 광학 스캐너와 콘빔CT에서 생성된 디지털 모형의 비교)

  • Kwon, Hyuk-Jin;Kim, Kack-Kyun;Yi, Won-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.60-69
    • /
    • 2016
  • Purpose: The objective of this study was to compare the accuracy of digital models from 3 dimentional (3D) optical scanner and cone beam computed tomography (CBCT). Materials and Methods: We obtained digital models from 11 pairs of stone casts using a 3D optical scanner and a CBCT, and compared the accuracy of the models. Results: The error range of average positive distance was 0.059 - 0.117 mm and negative distance was 0.066 - 0.146 mm. Statistically (P < 0.05), average positive distance was larger than $70{\mu}m$ and shorter than $100{\mu}m$, and that of negative distance was larger than $100{\mu}m$ and shorter than $120{\mu}m$. Conclusion: We concluded that the accuracy of digital models generated from CBCT is not appropriate to make final prostheses. However, it may be acceptable for provisional restorations and orthodontic diagnoses with respect to the accuracy of the digitalization.

DEVELOPMENT OF A STORAGE SYSTEM FOR THE TREATMENT DATA AND IMAGE DATA IN DENTISTRY USING THE OPTICAL LASER CARD (광 카드를 이용한 치과 진료자료 및 영상자료 저장 system 개발)

  • Shin, Yong-Pil;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.110-140
    • /
    • 1998
  • One of the problems facing in all modern dental hospitals is the much efforts, manpower and space are needed to effectively sort and stack patients' charts of the various dental departments. In addition, the storage and prompt arrangement of x-ray films is also a problem. Therefore, if dental charts as well as films could be computerized, it would be easier to store and keep them; by data basing, many space, manpower and cost would be saved: data could also be effectively managed for the purpose of academic researches. This would be an epoch -making event in the development of dental hospital management. The purpose of this study is to develop a dental information processing program, that will be used to store dental treatment records and digital image data using a new record media, the optical card. The patients' charts from the dental hospital were selected. The treatment records of the chart were put into the treatment data -recording area of the program, and the digital images of various dental x-ray films were made with a scanner. These data were stored in the optical card and analyzed to get the following results: 1. In this program it is possible to put treatment records and image data into and out from the optical card, and it is impossible to correct and delete all data recorded on the optical card. 2. All data in the optical card system can be searched and analyzed on database. 3. The resolution of image data stored in optical card is above 5.9 lp/mm. 4, All data of dental charts used as samples, stored to optical cards, occupies average 14%, In conclusion, with the development of the storage system using the optical card, a dental patient's life-time treatment record can be stored in one optical card and used as a substitute for the dental chart.

  • PDF

Effects of Refraction of Ultrasonic Beam on B-mode Tomograms (B-mode 단층상에서의 초음파 빔의 굴절 영향)

  • 최종수
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.141-144
    • /
    • 1981
  • This paper descirbes about effects of refraction of ultrasonic beam on B-mode tomogram. Both compution based on Snell's law and the experiments performed using B-mode scanner and schlieren optical method are discussed on a circular phantom immersed in water. In these results, if the discrepancy of sound velocity is more than 0. 6%, the distortion of the B-mode image becomes conspicuous and a target beyound the phantom may disappear or displayed as two targets depending on the velocity of the phantom.

  • PDF

Stress Induced Gigantic Piezoelectricity of PZT thin films for Actuated Mirror Array

  • Suzuki, Hisao
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.591-596
    • /
    • 2006
  • Lead zirconate titanate(PZT) thin films have been attracting worldwide interests in exploring their potential properties [1-3] or the origins [4-6] of their excellent dielectic, ferroelectric and piezoelectric properties near the morphotropic phase boundary (MPB). PZT thin films are expected to apply to the memory devices, micro electro mechanical systems (MEMS), and display because of their superior ferroelectric, pyroelectric, piezoelectric and electron emission properties. In this study, high- performance piezoelectric PZT thin films for actuated mirror array and optical scanner were developed by controlling the several factors, such as molecular-designed precursor, seeding layer and the residual stress in films, by a chemical solution deposition (CSD).

  • PDF

Measurement of Effective Refractive Index of Nematic Liquid Crystal in Fabry-Perot Etalon

  • Ko, Myeong Ock;Kim, Sung-Jo;Kim, Jong-Hyun;Lee, Bong Wan;Jeon, Min Yong
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.346-350
    • /
    • 2015
  • We report a measurement of the effective refractive index of a nematic liquid crystal (NLC) inside a Fabry-Perot (FP) etalon according to the applied electric fields. The effective refractive index of the NLC depends on the intensity of the applied electric field. A wavelength-swept laser with a polygon-scanner-based wavelength filter is used as a wide-band optical source to measure the effective refractive index of the NLC. The bandwidth of the optical source is greater than 90 nm around 1300 nm. The fabricated NLC FP etalon consists of glass substrates, gold layers as the electrodes with highly reflective surfaces, polyimide layers as the planar alignment layers, and an LC layer. Furthermore, we measured the Freedericksz transition voltages for three types of NLC FP etalons having thicknesses of $30.6{\mu}m$, $55.4{\mu}m$, and $108.8{\mu}m$. The Freedericksz transition voltages in the three cases are nearly equal. The measured effective refractive indices in the three cases decreased from 1.67 to 1.51 as the applied electric field intensity was increased. Beyond the threshold electric field, the effective refractive indices quickly decreased and eventually saturated at a value of 1.51 for all cases.

Wide-fan-angle Flat-top Linear Laser Beam Generated by Long-pitch Diffraction Gratings

  • Lee, Mu Hyeon;Ryu, Taesu;Kim, Young-Hoon;Yang, Jin-Kyu
    • Current Optics and Photonics
    • /
    • v.5 no.5
    • /
    • pp.500-505
    • /
    • 2021
  • We demonstrated a wide-fan-angle flat-top irradiance pattern with a very narrow linewidth by using an aspheric lens and a long-pitch reflective diffraction grating. First, we numerically designed a diffraction-based linear beam homogenizer. The structure of the Al diffraction grating with an isosceles triangular shape was optimized with 0.1-mm pitch, 35.5° slope angle, and 0.02-mm radius of the rounding top. According to the numerical results, the linear uniformity of the irradiance was more sensitive to the working distance than to the shape of the Al grating. The designed Al grating reflector was fabricated by using a conventional mold injection and an Al coating process. A uniform linear irradiance of 405-nm laser diode with a 100-mm flat-top length and 0.176-mm linewidth was experimentally demonstrated at 140-mm working distance. We believe that our proposed linear beam homogenizer can be used in various potential applications at a precise inspection system such as three-dimensional morphology scanner with line lasers.

Design of foot parameter measurement system in 3D Point cloud (3D 점군 데이터에서의 발 고유 변인 검출 시스템 설계)

  • Yun, Jeongrok;Kim, Un Yong;Kim, Hoemin;Chun, Sungkuk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.695-696
    • /
    • 2021
  • 최근 다양한 연령층과 직업군들 사이에서 기능성 신발에 대한 관심이 증대되고 있다. 그러나 기능성 신발 및 맞춤형 신발은 높은 가격대와 긴 제작 시간이 필요하다. 이러한 문제점은 3D 스캐너 도입으로 해결이 가능하나, 정확한 발 형상 측정이 가능한 3D 스캐너는 고가의 장비이기 때문에 매장별 보급이 어렵다. 본 논문은 기능성 신발의 보급을 위하여 저가형 3D 스캐너에서 정확한 발 고유 변인을 측정할 수 있는 시스템에 대해 서술한다. 이를 위해 이를 위해 저가형 Depth Camera를 이용한 저가형 3D 스캐너의 발 형상 3D 점군 데이터를 2차원으로 변형하고, 발 형태를 감싸는 최소 사각형(Min Area Rect)를 형성하여 발 안쪽점 및 발 가쪽점을 추정한다. 생성된 최소 사각형과 발 안쪽점 및 발 가쪽점 등은 발 고유 변인 측정의 기준이 된다. 실험 결과에서는 측정 기준을 이용하여 발 고유 변인인 발 길이, 발 너비, 발꿈치 너비, 발꿈치에서 발안쪽점 및 발 가쪽점 길이 등 5가지 고유 변인을 측정하는 것을 보여준다.

  • PDF

A Study on the Curvature Correction in Laser Scanner (레이저 주사 장치의 곡률 보정에 관한 연구)

  • Yun, N.I.;Kim, N.;Park, H.K.
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1986.10a
    • /
    • pp.194-197
    • /
    • 1986
  • In this paper, for the curvature correction on the scanning plane in laser scanning system, aberration correction method using holographic optical element is suggested. Holoens is selected as a type of holographic zone plate which has aberration correction property. And hologram recording condition is analyzed to find fo property. This hololens is implemented by computer-generated hologram technique. Laser scanning system is organized using desinged hololens and scanning properties of this system are investigated. Using this method optical system structure in laser scanning system can be simplified satisfying both scan linearity and field flatness.

  • PDF

Optical Design for Trepanning Drilling (레이저 트레판닝 드릴링을 위한 광학 설계)

  • Noh, Ji-Whan;Lee, Jae-Hoon;Suh, Jung;Sohn, Hyon-Kee;Shin, Dong-Sig
    • Laser Solutions
    • /
    • v.10 no.3
    • /
    • pp.11-14
    • /
    • 2007
  • A trepanning optics is the optical system which makes focus laser beam rotate and incline to the material processing surface. The trepanning optics is used in order to improve the quality of laser drilling process and control the taper of drilling diameter. In order to make trepanning optics, we can use the eccentricity of lens, scanner using two mirror, dove prism, or wedge. Among these method, in this paper wedge is used for trepanning optics. The wedge trepanning optics has advantage on the high speed of rotation. In this paper, we design the wedge trepanning optics using ray tracing. ements and engine design variables of system to satisfy the customer's requirements.

  • PDF