• Title/Summary/Keyword: Optical properly

Search Result 122, Processing Time 0.025 seconds

A Framework of Recognition and Tracking for Underwater Objects based on Sonar Images : Part 2. Design and Implementation of Realtime Framework using Probabilistic Candidate Selection (소나 영상 기반의 수중 물체 인식과 추종을 위한 구조 : Part 2. 확률적 후보 선택을 통한 실시간 프레임워크의 설계 및 구현)

  • Lee, Yeongjun;Kim, Tae Gyun;Lee, Jihong;Choi, Hyun-Taek
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.164-173
    • /
    • 2014
  • In underwater robotics, vision would be a key element for recognition in underwater environments. However, due to turbidity an underwater optical camera is rarely available. An underwater imaging sonar, as an alternative, delivers low quality sonar images which are not stable and accurate enough to find out natural objects by image processing. For this, artificial landmarks based on the characteristics of ultrasonic waves and their recognition method by a shape matrix transformation were proposed and were proven in Part 1. But, this is not working properly in undulating and dynamically noisy sea-bottom. To solve this, we propose a framework providing a selection phase of likelihood candidates, a selection phase for final candidates, recognition phase and tracking phase in sequence images, where a particle filter based selection mechanism to eliminate fake candidates and a mean shift based tracking algorithm are also proposed. All 4 steps are running in parallel and real-time processing. The proposed framework is flexible to add and to modify internal algorithms. A pool test and sea trial are carried out to prove the performance, and detail analysis of experimental results are done. Information is obtained from tracking phase such as relative distance, bearing will be expected to be used for control and navigation of underwater robots.

Analysis of inner parts in the disc cutters applied to the field tests (현장적용 디스크커터의 내부부품 분석)

  • Bae, Gyu-Jin;Choi, Soon-Wook;Chang, Soo-Ho;Lee, Gyu-Phil;Song, Bong-Chan;Kim, Kab-Boo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.4
    • /
    • pp.473-485
    • /
    • 2015
  • The problems for non-rotating of a disc cutter proceed from the faults in inner parts of the disc cutter such as the leak of hydraulic fluid, the intrusion of tunnel mucks and water, overloading, overheating, poor assembly and substandard material. The rotating of a disc cutter is an indicator to show that the inner parts of disc cutter is operable, although the rotational torque depends on the extent of the damage. Therefore, the key in the problems for non-rotating of disc cutter is to maintain that the tapered roller bearings are working properly. This study aims to investigate the inner parts disassembled from disc cutters applied to the field tests in order to help decision for reuse of the disc cutters. As results, surface finishing to remove the scratch on the load zone of the hubs is needed, with the intent to reuse a hub. And the investigation of lapping surface by optical microscope of floating seals and the contamination test of oil need to be performed for reuse of a disc cutter. Especially, the analysis results show that the floating seals play a key role in the normal operation of bearings. There is nothing significant to report in the rest parts such as bearing, shaft, seal retainers.

Fabrication of a Schottky Type Ultraviolet Photodetector Using GaN Layer (GaN를 이용한 Schottky diode형 자외선 수광소자의 제작)

  • Seong, Ik-Joong;Lee, Suk-Hun;Lee, Chae-Hyang;Lee, Yong-Hyun;Lee, Jung-Hee;Hahm, Sung-Ho
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.6
    • /
    • pp.28-34
    • /
    • 1999
  • We fabricated a planar ultra-violet photodetector whose ohmic and schottky contacts were respectively formed with evaporated Al and Pt on the GaN layer. To examine the applicability of the device to the UV sensor, we investigated its electrical and optical characteristics. The GaN layer on the sapphire waver had $7.8{\times}10^{16}cm^{-3}$ of doping concentnation and the $138 cm^2/V{\cdot}s$ of electron mobility and it absorbed the spectrum of the light below 325 nm wavelength. It had the responsivity of 2.8 A/W of at 325 nm, and the signal to noise ratio(SNR) of $4{\times}10^4$, and the noise equivalent power(NEP) of $3.5{\times}10^9$W under 5 V reverse bias. These results confirmed that the GaN schottky diode had a solar blind properly when it was applied to the UV photodetector.

  • PDF

Endotracheal intubation by inexperienced trainees using the Clarus Video System: learning curve and orodental trauma perspectives

  • Moon, Young-Jin;Kim, Juyoung;Seo, Dong-Woo;Kim, Jae-Won;Jung, Hye-Won;Suk, Eun-Ha;Ha, Seung-Il;Kim, Sung-Hoon;Kim, Joung-Uk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.4
    • /
    • pp.207-212
    • /
    • 2015
  • Background: The ideal alternative airway device should be intuitive to use, yielding proficiency after only a few trials. The Clarus Video System (CVS) is a novel optical stylet with a semi-rigid tip; however, the learning curve and associated orodental trauma are poorly understood. Methods: Two novice practitioners with no CVS experience performed 30 intubations each. Each trial was divided into learning (first 10 intubations) and standard phases (remaining 20 intubations). Total time to achieve successful intubation, number of intubation attempts, ease of use, and orodental trauma were recorded. Results: Intubation was successful in all patients. In 51 patients (85%), intubation was accomplished in the first attempt. Nine patients required two or three intubation attempts; six were with the first 10 patients. Learning and standard phases differed significantly in terms of success at first attempt, number of attempts, and intubation time (70% vs. 93%, $1.4 {\pm}0.7$ vs. $1.1{\pm}0.3$, and $71.4{\pm}92.3s$ vs. $24.6{\pm}21.9s$, respectively). The first five patients required longer intubation times than the subsequent five patients ($106.8{\pm}120.3s$ vs. $36.0{\pm}26.8s$); however, the number of attempts was similar. Sequential subgroups of five patients in the standard phase did not differ in the number of attempts or intubation time. Dental trauma, lip laceration, or mucosal bleeding were absent. Conclusions: Ten intubations are sufficient to learn CVS utilization properly without causing any orodental trauma. A relatively small number of experiences are required in the learning curve compared with other devices.

On the Study of Initializing Extended Depth of Focus Algorithm Parameters (Extended Depth of Focus 알고리듬 파라메타 초기설정에 관한 연구)

  • Yoo, Kyung-Moo;Joo, Hyo-Nam;Kim, Joon-Seek;Park, Duck-Chun;Choi, In-Ho
    • Journal of Broadcast Engineering
    • /
    • v.17 no.4
    • /
    • pp.625-633
    • /
    • 2012
  • Extended Depth of Focus (EDF) algorithms for extracting three-dimensional (3D) information from a set of optical image slices are studied by many researches recently. Due to the limited depth of focus of the microscope, only a small portion of the image slices are in focus. Most of the EDF algorithms try to find the in-focus area to generate a single focused image and a 3D depth image. Inherent to most image processing algorithms, the EDF algorithms need parameters to be properly initialized to perform successfully. In this paper, we select three popular transform-based EDF algorithms which are each based on pyramid, wavelet transform, and complex wavelet transform, and study the performance of the algorithms according to the initialization of its parameters. The parameters we considered consist of the number of levels used in the transform, the selection of the lowest level image, the window size used in high frequency filter, the noise reduction method, etc. Through extended simulation, we find a good relationship between the initialization of the parameters and the properties of both the texture and 3D ground truth images. Typically, we find that a proper initialization of the parameters improve the algorithm performance 3dB ~ 19dB over a default initialization in recovering the 3D information.

A Study on the contamination measurement of spacecraft components under High Vacuum Environment (고진공하에서의 위성체 부품의 오염측정에 관한 연구)

  • 이상훈;서희준;문귀원;최석원
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.2
    • /
    • pp.87-96
    • /
    • 2002
  • Outgassing from such sources as paints, coatings, adhesives and other non-metallic surfaces can contaminate satellites, especially second surface mirror and optical lens, it cause satellite to fail in own missions. The vacuum bake-out test using high temperature(more than $85 ^{\circ}C$)and high vacuum(less than $5.0{\times}1-^{-3}$ Pa) certify that the components of satellite work properly and can survive and operate in space environment like high vacuum. In the bake-out chamber installed at SITC of KARI, Rotary vacuum pump and Booster pump produce low vacuum of 5.0 Pa, and then two cryopumps produce high vacuum of below $5.0{\times}10^{-3}$ Pa. Also 48 ceramic heaters were provided to simulate high temperature. During the vacuum bake-out test, we detected contaminants using RGA(Residual Gas Analyzer) and measure the outgassing rate of the contaminant using the TQCM(Thermoelectric Quartz Crystal Microbalance). Also, IR/UV Spectrometer and witness plate be used to certify that the components were suitable for the spacecraft. This paper includes the preparation and procedures of the bake-out test for SAR(Solar Array Regulator) and MLI(Multi Layer Insulator), which were the components of the spacecraft. Especially, we discussed the methods and results of the contamination measurement. In the bake-out for SAR, the contamination was measured continuously although it was on the decrease from TQCM results. And RCA established that it is a highly polymerized compound. In the MLI bake-out using RGA and witness plate, we didn't detect any contamination materials.

Study on image quality improvement using Non-Linear Look-Up Table (비선형 Look-Up Table을 통한 영상 화질 개선에 관한 연구)

  • Kim, Sun-Chil;Lee, Jun-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.32-44
    • /
    • 2002
  • The role of radiology department has been greatly increased in the past few years as the technology in the medical imaging devices improved and the introduction of PACS (Picture Archiving and Communications System) to the conventional film-based diagnostic structure is a truly remarkable factor to the medical history. In addition, the value of using digital information in medical imaging is highly expected to grow as the technology over the computer and the network improves. However, the current medical practice, using PACS is somewhat limited compared to the film-based conventional one due to a poor image quality. The image quality is the most important and inevitable factor in the PACS environment and it is one of the most necessary steps to more wide practice of digital imaging. The existing image quality control tools are limited in controlling images produced from the medical modalities, because they cannot display the real image changing status. Thus, the image quality is distorted and the ability to diagnosis becomes hindered compared to the one of the film-based practice. In addition, the workflow of the radiologist greatly increases; as every doctor has to perform his or her own image quality control every time they view images produced from the medical modalities. To resolve these kinds of problems and enhance current medical practice under the PACS environment, we have developed a program to display a better image quality by using the ROI optical density of the existing gray level values. When the LUT is used properly, small detailed regions, which cannot be seen by using the existing image quality controls are easily displayed and thus, greatly improves digital medical practice. The purpose of this study is to provide an easier medical practice to physicians, by applying the technology of converting the H-D curves of the analog film screen to the digital imaging technology and to preset image quality control values to each exposed body part, modality and group of physicians for a better and easier medical practice. We have asked to 5 well known professional physicians to compare image quality of the same set of exam by using the two different methods: existing image quality control and the LUT technology. As the result, the LUT technology was enormously favored over the existing image quality control method. All the physicians have pointed out the far more superiority of the LUT over the existing image quality control method and highly praised its ability to display small detailed regions, which cannot be displayed by existing image quality control tools. Two physicians expressed the necessity of presetting the LUT values for each exposed body part. Overall, the LUT technology yielded a great interest among the physicians and highly praised for its ability to overcome currently embedded problems of PACS. We strongly believe that the LUT technology can enhance the current medical practice and open a new beginning in the future medical imaging.

  • PDF

IGRINS Mirror Mount Design for Three Off-Axis Collimators and One Slit-Viewer Fold Mirror

  • Rukdee, Surangkhana;Park, Chan;Kim, Kang-Min;Lee, Sung-Ho;Chun, Moo-Young;Yuk, In-Soo;Oh, Hee-Young;Jung, Hwa-Kyoung;Lee, Chung-Uk;Lee, Han-Shin;Rafal, Marc D.;Barnes, Stuart;Jaffe, Daniel T.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.2
    • /
    • pp.233-244
    • /
    • 2012
  • The Korea Astronomy and Space Science Institute and the Department of Astronomy at the University of Texas at Austin are developing a near infrared wide-band high resolution spectrograph, immersion grating infrared spectrometer (IGRINS). The compact white-pupil design of the instrument optics uses seven cryogenic mirrors, including three aspherical off-axis collimators and four flat fold mirrors. In this study, we introduce the optomechanical mount designs of three off-axis collimating mirrors and one flat slit-viewer fold mirror. Two of the off-axis collimators are serving as H and K-band pupil transfer mirrors, and are designed as system alignment compensators in combination with the H2RG focal plane array detectors in each channel. For this reason, the mount designs include tip-tilt and parallel translation adjustment mechanisms to properly perform the precision alignment function. This means that the off-axis mirrors' optomechanical mount designs are among the most sensitive tasks in all IGRINS system hardware. The other flat fold mirror is designed within its very limitedly allowed work space. This slit-viewer fold mirror is mounted with its own version of the six-point kinematic optics mount. The design work consists of a computer-aided 3D modeling and finite element analysis (FEA) technique to optimize the structural stability and the thermal behavior of the mount models. From the structural and thermal FEA studies, we conclude that the four IGRINS mirror mounts are well designed to meet all optical stability tolerances and system thermal requirements.

A Study for the Limitation of Measurement Accuracy and Reliability of Autostigmatic Null lens System by Adjustment and Fixing Process (조정방식과 경통고정방식에 대한 자동무수차점 널 렌즈 광학계의 측정 정밀도 한계 및 신뢰도)

  • Lee, Young-Hun;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.5
    • /
    • pp.440-445
    • /
    • 2005
  • The limitation of measurement accuracy and reliability of autostigmatic null lens system are studied for the cases of using inter-distance of null lenses as the adjustment factor of alignment and fixing the distance by mounting. If we investigate the first case, the wavefront aberration of null lens system is compensated by the adjustment process even though the shape of aspherical surface is not properly fabricated. As the result, it brings about the problem of measurement reliability. However, for the fixing process by mounting null lenses, it doesn't cause the reliability problem because the wavefront aberration of null lens system is not compensated. Further, the fixing process shows nearly same result in measurement accuracy to the adjustment process, that is, $0.0316{\lambda}$ vs. $0.0326{\lambda}$. So, we can conclude the setup for autostigmatic null lens system must be constituted by means of the fixing process. Meanwhile, we introduce and define the alignment aperture on aspheircal mirror, which can be approximated as spherical zone for alignment of null lens system, and besides, we calculate the required fabrication accuracy of the zone for the necessary measurement accuracy.

A Study on Technological Forecasting for Promising Alternative Technologies Using Fisher-Pry Modification Model (Fisher-Pry 수정모형을 활용한 유망대체기술 예측에 관한 연구)

  • Hong, Sung-Il;Kim, Byung-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.5
    • /
    • pp.104-114
    • /
    • 2019
  • In the global market competition, countries and businesses are actively engaged in technology prediction activities to maximize their profits by attempting to enter and preempting the core technology of the future. In this paper, we propose a growth model based on patent application trends to predict the time to replace a product with a promising new technology to dominate the market. Although the Fisher-Pry model that Bhargava generalized to predict the emergence of promising alternative technologies was relatively satisfactory compared to the original Fisher-Pry model, it was difficult to predict the replacement rate behavior properly due to a parameter problem. The application of the Fisher-Pry Modification Model in the form of a quadratic equation through the patent trend analysis of the optical storage system for the purpose of verifying the time alternative to the light storage technology has resulted in satisfactory verification results. It is expected that small and medium-sized companies and individual researchers will apply this model and use it more easily to predict the time to replace the market for promising replacement technologies.