• 제목/요약/키워드: Optical imaging

검색결과 1,293건 처리시간 0.025초

3D Integral Imaging Display using Axially Recorded Multiple Images

  • Cho, Myungjin;Shin, Donghak
    • Journal of the Optical Society of Korea
    • /
    • 제17권5호
    • /
    • pp.410-414
    • /
    • 2013
  • In this paper, we propose a 3D display method combining a pickup process using axially recorded multiple images and an integral imaging display process. First, we extract the color and depth information of 3D objects for displaying 3D images from axially recorded multiple 2D images. Next, using the extracted depth map and color images, elemental images are computationally synthesized based on a ray mapping model between 3D space and an elemental image plane. Finally, we display 3D images optically by an integral imaging system with a lenslet array. To show the usefulness of the proposed system, we carry out optical experiments for 3D objects and present the experimental results.

Reflective Fourier Ptychographic Microscopy Using Segmented Mirrors and a Mask

  • Ahn, Hee Kyung;Chon, Byong Hyuk
    • Current Optics and Photonics
    • /
    • 제5권1호
    • /
    • pp.40-44
    • /
    • 2021
  • In this paper, LED arrays with segmented mirrors and a mask are presented as a new dark-field illuminator for reflective Fourier ptychographic microscopy (FPM). The illuminator can overcome the limitations of the size and the position of samples that the dark-field illuminator using a parabolic mirror has had. The new concept was demonstrated by measuring a USAF 1951 target, and it resolved a pattern in group 10 element 6 (274 nm) in the USAF target. The new design of the dark-field illuminator can enhance competitiveness of the reflective FPM as a versatile measurement method in industry.

이벤트 기반 물체 추적 시스템 개발 (Development of Event-based Object Tracking System)

  • 김상준;이현경;이승아;김대연
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송∙미디어공학회 2022년도 하계학술대회
    • /
    • pp.179-181
    • /
    • 2022
  • 동적 비전 센서(Dynamic Vision Sensor)라고도 알려진 이벤트 카메라는 생체에서 영감을 받은 새로운 시각 센서이다. 고정된 속도로 이미지를 생성하는 기존 카메라와 달리 이벤트 기반 카메라의 픽셀은 독립적이고 비동기적으로 작동한다. 기존 프레임 기반 카메라보다 이벤트 기반 카메라가 움직임을 포착하는데 더 적합하며 모션 블러(Motion Blur)가 없고 시간 해상도가 높다는 이점을 통해 고속카메라로 활용할 수 있다. 본 논문은 이벤트 카메라의 높은 시간 해상도와 동적 범위, 낮은 지연시간, 전력 소비량의 이점을 활용하여 움직이는 물체를 모션 블러 없이 포착하는 이벤트 기반 물체 추적 시스템을 제안한다. 실험을 통해 전체 영상을 포착하는 기존 프레임 기반 카메라에 비해 밝기 변화에 따른 동적 변화만을 추적하는 이벤트 기반 카메라는 모션 블러가 없다는 점을 검증하였다.

  • PDF

Three-Dimensional Analysis of the Collapse of a Fatty Acid at Various Compression Rates using In Situ Imaging Ellipsometry

  • Hwang, Soon Yong;Kim, Tae Jung;Byun, Jun Seok;Park, Han Gyeol;Choi, Junho;Kang, Yu Ri;Park, Jae Chan;Kim, Young Dong
    • Journal of the Optical Society of Korea
    • /
    • 제18권4호
    • /
    • pp.350-358
    • /
    • 2014
  • The collapse of Langmuir monolayers of arachidic acid (AA) on water at various rates of molecular area compression has been investigated in situ by imaging ellipsometry (IE). The thickness of the collapsed AA molecules, which are inherently inhomogeneous, was determined by IE with a spatial resolution of a few microns. For the analysis, we determined the dielectric function of AA monolayers from 380 to 1690 nm by conventional spectroscopic ellipsometry. Compression rates ranged from 0.23 to $0.94{\AA}^2/min$. A change of multilayer domains was observed in the in situ IE images. Lower compression rates resulted in more uniform collapsed films. Our experimental results correspond with previous theoretical simulations.

Common Optical System for the Fusion of Three-dimensional Images and Infrared Images

  • Kim, Duck-Lae;Jung, Bo Hee;Kong, Hyun-Bae;Ok, Chang-Min;Lee, Seung-Tae
    • Current Optics and Photonics
    • /
    • 제3권1호
    • /
    • pp.8-15
    • /
    • 2019
  • We describe a common optical system that merges a LADAR system, which generates a point cloud, and a more traditional imaging system operating in the LWIR, which generates image data. The optimum diameter of the entrance pupil was determined by analysis of detection ranges of the LADAR sensor, and the result was applied to design a common optical system using LADAR sensors and LWIR sensors; the performance of these sensors was then evaluated. The minimum detectable signal of the $128{\times}128-pixel$ LADAR detector was calculated as 20.5 nW. The detection range of the LADAR optical system was calculated to be 1,000 m, and according to the results, the optimum diameter of the entrance pupil was determined to be 15.7 cm. The modulation transfer function (MTF) in relation to the diffraction limit of the designed common optical system was analyzed and, according to the results, the MTF of the LADAR optical system was 98.8% at the spatial frequency of 5 cycles per millimeter, while that of the LWIR optical system was 92.4% at the spatial frequency of 29 cycles per millimeter. The detection, recognition, and identification distances of the LWIR optical system were determined to be 5.12, 2.82, and 1.96 km, respectively.