• Title/Summary/Keyword: Optical fiber measurement

Search Result 466, Processing Time 0.029 seconds

Optical Current Measuring System for Compensating Interference by Adjacent Electric Wires

  • Cho, Jae-Kyong
    • Journal of Magnetics
    • /
    • v.12 no.4
    • /
    • pp.156-160
    • /
    • 2007
  • In this paper, we analyze the errors associated with magnetic field interference for fiber-optic current sensors working in a three-phase electric system and provide a solution to compensate the interference. For many practical conductor arrangements, the magnetic filed interference may cause errors unacceptable for the accuracy requirements of the sensors. We devised a real time compensation method for the interference by introducing geometric and weight factors. We realized the method using simple electronic circuits and obtained the real time compensated outputs with errors of ${\pm}1%$.

Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector

  • Song, Siwon;Kim, Jinhong;Park, Jae Hyung;Kim, Seunghyeon;Lim, Taeseob;Kim, Jin Ho;Kim, Sin;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3398-3402
    • /
    • 2022
  • We fabricated a 15 m long position-sensitive plastic scintillation optical fiber (PSOF) detector consisting of a PSOF, two photomultiplier tubes, four fast amplifiers, and a digitizer. A single PSOF was used as a sensing part to estimate the gamma-ray source position, and 137Cs, an uncollimated solid-disk-type radioactive isotope, was used as a gamma-ray emitter. To improve the sensitivity, accuracy, and measurement time of a PSOF detector compared to those of previous studies, the performance of the amplifier was optimized, and the digital signal processing (DSP) was newly designed in this study. Moreover, we could measure very low dose rates of gamma-rays with high sensitivity and accuracy in a very short time using our proposed PSOF detector. The results of this study indicate that it is possible to accurately and quickly locate the position of a very low dose rate gamma-ray source in a wide range of contaminated areas using the proposed position-sensitive PSOF detector.

Reflection-type Optical Waveguide Index Profiling Technique

  • Youk YoungChun;Kim Dug Young
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.49-53
    • /
    • 2005
  • We report a new configuration of a reflection-type confocal scanning optical microscope system for measuring the refractive index profile of an optical waveguide. Several improvements on the earlier design are proposed; a light emitting diode (LED) at 650 nm wavelength instead of a laser diode (LD) or He-Ne laser is used as a light source for better index precision, and a simple longitudinal linear scanning and curve fitting techniques are adapted instead of a servo control for maintaining an optical confocal arrangement. We have obtained spatial resolution of 700 nm and an index precision of $2\times10^{-4}$. To verify the system's capability, the refractive index profiles of a conventional multimode fiber and a home-made four-mode fiber were examined with our proposed measurement method.

Measurement of Behaviors of Optical Filter using Evanescent Field Coupling between Single Mode Fiber and Multimode Planar Waveguide (단일모드 광섬유와 다중모드 평면도파로의 소산장결합을 이용한 광필터의 동작특성 측정)

  • Kim, Kwang-Taek;Yu, Ho-Jong;Song, Jae-Won;Kim, Si-Hong;Kang, Shin-Won
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.7
    • /
    • pp.42-49
    • /
    • 1999
  • In this paper, we proposed a simple measurement method to find the behaviors of the fiber-to-waveguide coupler. The polished fiber blocks and planar waveguides on silicon dioxide were fabricated independently and then optically coupled by physical pressure. Several kinds of polymer with different refractive indices were used for waveguide films. The proposed method makes it possible to measure the center wavelength, bandwidth, extinction ratio, and polarization dependence of the coupler during fabrication procedure. The wavelength sensitivity increased with refractive index of polymer. The symmetric planar waveguide structure and isotropic property of guiding materials reduced polarization dependent property. Insertion loss of the coupler was less than 0.5dB. It is expected that our measurement method is useful for developing various optical devices using evanescent coupling between polished fiber and planar waveguide such as optical modulators and filters etc.

  • PDF

The study on the fiber optic sensor for the distributed temperature measurement (분포온도 계측을 위한 광파이버 온도센서 시스템에 관한 연구)

  • 이광진;최성구;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1746-1749
    • /
    • 1997
  • A distributed optical fiber temperature sensor can continually monitor the measurand at every point along of its fiber length. It is based on OTDR technics which used extreamlly weak backward scattered light called Raman scattering. When the Pulsed high intensity laser light injected into the optical fiber there are several kind of backscattered light such as Rayleigh, Stokes, and anti-Stokes, etc. caused by impurities molecular vibrations. The temperature distribution is derived form the intensity ratio Raman scatted light-Stokes versus anti-Stokes-and the time function between light injection and signal detection. It is shown that the priniciple of distributed sensing, the system desing, and the result of experiments.

  • PDF

A Fiber Optic Sensor for Measurements of Solute Concentration in Fluids

  • Kim, Chang-Bong;Su, C.B.
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.102-105
    • /
    • 2003
  • A new and simple calibration technique that greatly enhances the measurement sensitivity of conventional fiber-optic reflectometry based on Fresnel reflection from the tip of a fiber is used for demonstrating the feasibility of measuring solute concentrations and index changes in fluids to very high precision. The amplitude of pulses originating from reflection from the fiber-fluid interface is compared in real-time with the amplitude of reference pulses from a fiber-air interface such that errors caused by pulse amplitude fluctuations and slightly varying detector responses are corrected. Using solutions of salt and water, it is demonstrated that the technique is capable of measuring index changes of about $1 {\times} 10^{-5}$ corresponding to a salt concentrations of 0.01 %.

A Study on Elecctronic Speckle Contouring for 3-D Shape Measurement (3차원 형상측정을 위한 전자 스페클 등고선 추출법에 관한 연구)

  • 김계성
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.239-244
    • /
    • 1998
  • ESP(Electronic Speckle Pattern Interferometry) is an optical technique to measure deforamtion of engineering components and materials in industrial areas. ESPI, a non-contact and non-destructive measuring method, is capable of providing full-field results with high spatial resolution and high speed. One of important application aspects using electronic speckle pattern interferometry is to generate contours of a diffuse object in order to provide data for 3-D shape analysis and topography measurement. The electronic speckle contouring is suitable for providing measurement range from millimeters to several centimeters. In this study, we introduce the contouring method by modified dual-beam speckle pattern interferometer and a shift of the two illumination beams through optical fiber in order to obtain the contour fringe patterns. Before the experiments, we performed the geometric analysis for dual-beam-shifted ESPI contouring. And by this geometric analysis, we performed the electronic speckle contouring experiment. We used 4-frame phase shifting method with PZT for quantitative analysis of contour fringes. Finally, we showed good agreements between the geometric analysis and experimental results.

  • PDF

Measurement of the Molten Steel Temperature Using the Sapphire Fiber (사파이어 광섬유를 이용한 용선 온도측정)

  • Kim, Hasul;Homun Bae
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.240-241
    • /
    • 2000
  • Sapphire fiber has been used to provide an optical path for the total radiation pyrometry. In measuring the temperature, we use the two-color detector, which consists of a high-performance Silicon detector mounted in a "sandwich" configuration over a Germanium detector. Sapphire fiber can withstand high temperature in the molten steel for two and a half hours. The maximum value of the error is the $\pm$2.5$^{\circ}C$ in the range of 152$0^{\circ}C$~1$600^{\circ}C$. This paper presents the simple scheme for measuring the molten steel temperature in the blast furnace of the iron & steel making process.g process.

  • PDF