• Title/Summary/Keyword: Optical Transmission Image

Search Result 114, Processing Time 0.031 seconds

RGB-LED-based Optical Camera Communication using Multilevel Variable Pulse Position Modulation for Healthcare Applications

  • Rachim, Vega Pradana;An, Jinyoung;Pham, Quan Ngoc;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.6-12
    • /
    • 2018
  • In this paper, a 32-variable pulse position modulation (32-VPPM) scheme is proposed to support a red-green-blue light-emitting-diode (RGB-LED)-based optical camera communication (OCC) system. Our proposed modulation scheme is designed to enhance the OCC data transmission rate, which is targeted for the wearable biomedical data monitoring system. The OCC technology has been utilized as an alternative solution to the radio frequency (RF) wireless system for long-term self-healthcare monitoring. Different biomedical signals, such as electrocardiograms, photoplethysmograms, and respiration signals are being monitored and transmitted wirelessly from the wearable biomedical device to the smartphone receiver. A common 30 frames per second (fps) smartphone camera with a CMOS image sensor is used to record a transmitted optical signal. Moreover, the overall proposed system architecture, modulation scheme, and data demodulation are discussed in this paper. The experimental result shows that the proposed system is able to achieve > 9 kbps using only a common smartphone camera receiver.

Study on the Optical Properties Change according to the LED Illumination Collimator Lens Design Parameters (LED 조명용 Collimator Lens 설계변수에 따른 광학적 특성 변화에 관한 연구)

  • Won, Ye-Lim;Park, Gwang-Il;Jang, Jae-Hyeon;Kim, Jong-Tae;Yu, Young-Moon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.21-29
    • /
    • 2016
  • In this paper, optical tracking and analysis was carried out to find the optical properties with respect to various geometric design parameters of collimator lens which is very efficient when collect the light. As a result, a whole, ellipse incident part can obtain a high light efficiency and a narrow beam angle, and angled cylinder incident part is confirmed to obtain high efficiency and a narrow beam angle at a certain height or more. When Transmission part have a specific surface which can reflect the light in forward direction, a good optical properties was confirmed.

Development of vision system for the character recognition of the billet image (빌렛영상에 포함된 문자인식을 위한 비전시스템 개발)

  • Park, Sang-Gug
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.13 no.1
    • /
    • pp.22-29
    • /
    • 2008
  • This paper describes the developed results of vision system for the recognition of material management characters, which was included in the billet image. The material management characters, which was marked at the surface of billet, should be recognized before billet moves to the next process. Our vision system for the character recognition includes that CCD camera system which acquire billet image, optical transmission system which transmit captured image to the long distance, input and output system for the interface with existing system and software for the character recognition. We have installed our vision system at the wire rod line of steel & iron plant and tested. Also, we have performed inspection of durability, reliability and recognition rate. Through the testing, we have confirmed that our system have high recognition rate, 98.6%.

  • PDF

THE ANALYSIS OF THE INFLUENCE OF THE COMPRESSION ON THE LOW EARTH ORBIT SATELLITE PAYLOAD SYSTEM

  • Shin, Sang-Youn;Choi, Myung-Jin;Heo, Haeng-Pal;Yong, Sang-Soon
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.232-235
    • /
    • 2008
  • The mission of the EO(electro-optical) based low earth orbit satellite is provision of the high-resolution images required for GIS(Geographical Information Systems) establishment and the applications for environmental, agriculture and ocean monitoring. AEISS(Advanced Earth Imaging Sensor System) which is the main payload on the satellite consists of EOS(electro-optical subsystem) and PDTS(Payload Data Transmission Sub-system). IDHU(Image Data Handling Unit) which is one of the major unit in PDTS is capable of compression, storage, encryption and encoding. In this paper, the payload system of the EO based satellite is briefly introduced and the influence of the compression on AEISS is analyzed.

  • PDF

Calibration of monodisperse polystylene spheres of size from 1 to 10 ${\mu}m$ by using optical array sizing method (광학적 입자열 측정법에 의한 폴리스티렌구의 평균지름 측정)

  • 강주식
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.1
    • /
    • pp.21-26
    • /
    • 1999
  • The technique for calibrating standard particles larger than 1 $\mu$m by using an optical array sizing method has been established. The system consists of an optical microscope with transmission light source, a CCD camera, and a computer equipped with a frame grabber. The center distance between two spheres located at both ends of a row which consists of N spheres is measured in terms of pixel numbers, and divided by (N-1) to obtain the average pixel numbers per particle. This value is multiplied by length conversion constant, which has been determined in advance, to obtain the mean diameter of polystylene spheres. The length conversion constant is found from the microscopic image of calibrated standard stage micrometer plate. In order to reduce error in finding center positions of the scale and particles in the image, a software filter which dilates bright (or dark) object has been used. Spheres having nominal size of 1, 2, 3, 5, and 10$\mu$m were measured, and the maximum deviation of the measured mean diameter valus from their certified values was 0.7%. Standard particles which is larger than 1 $\mu$m can be calibrated by this method with measuredment uncertainy (k=2) lees than 1.53%.

  • PDF

Improvement of size measurement polystyrene spheres of diameters 3$\mu$m and 10$\mu$m by optical microscope with CCD camera (CCD 카메라가 장착된 광학현미경을 사용한 폴리스티렌구 (3 $\mu$m와 10 $\mu$m)의 평균지름측정)

  • 정기영;박병천;깅주식;송원영;오범환
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.362-367
    • /
    • 1998
  • Center Distance Finding (CDF) is a technique to find the sphere diameter by measuring the distance between two contacting spheres. The focal spots of the sphere clusters are formed in the back-focal plane by the transmission-mode optical microscope with the pseudothermal illumination source. Digital images taken by the CCD camera were processed by the software called Global Lab Image. The centers of the focal spots are found and the spot positions are expressed in terms of the CCD pixel elements, whose coordinate are calibrated by a heterodyne interferometer. The new CDF measurement system has been developed, which are more advantageous in time and convenience than the existing system, while the measurement uncertainly remains sufficient for its use as a magnification standard for optical microscopy. Two kinds of polystyrene spheres whose nominal diameters 3 and 10 $\mu\textrm{m}$ (NIST SRM 1962 and 1960) are measured with the uncertainly less than 1% at the confidence level of 99%, and the results are compared with the results of National Institute of Standards and Technology.

  • PDF

EUVL Mask Defect Isolation and Repair using Focused Ion Beam (Focused Ion Beam을 이용한 EUVL Mask Defect Isolation 및 Repair)

  • 김석구;백운규;박재근
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.2
    • /
    • pp.5-9
    • /
    • 2004
  • Microcircuit fabrication requires precise control of impurities in tiny regions of the silicon. These regions must be interconnected to create components and VLSI circuits. The patterns to define such regions are created by lithographic processes. In order to image features smaller than 70 nm, it is necessary to employ non-optical technology (or next generation lithography: NGL). One such NGL is extreme ultra-violet lithography (EUVL). EUVL transmits the pattern on the wafer surface after reflecting ultra-violet through mask pattern. If particles exist on the blank mask, it can't transmit the accurate pattern on the wafer and decrease the reflectivity. It is important to care the blank mask. We removed the particles on the wafer using focused ion beam (FIB). During removal, FIB beam caused damage the multi layer mask and it decreased the reflectivity. The relationship between particle removal and reflectivity is examined: i) transmission electron microscope (TEM) observation after particle removal, ii) reflectivity simulation. It is found that the image mode of FIB is more effective for particle removal than spot and bar mode.

  • PDF

Design of Quantization Tables and Huffman Tables for JPEG Compression of Medical Images (의료영상의 JPEG 압축을 위한 양자화 테이블과 허프만 테이블 설계)

  • 양시령;정제창;박상규
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.6
    • /
    • pp.453-456
    • /
    • 2004
  • Due to the bandwidth and storage limitations medical images are needed to be compressed before transmission and storage. DICOM (Digital Imaging and Communications in Medicine) specification, which is the medical images standard, provides a mechanism for supporting the use of JPEG still image compression standard. In this paper, we explain a method for compressing medical images by PEG standard and propose two methods for JPEG compression. First, because medical images differ from natural images in optical feature, we propose a method to design adaptively the quantization table using spectrum analysis. Second, because medical images have higher pixel depth than natural images do, we propose a method to design Huffman table which considers the probability distribution feature of symbols. Simulation results show the improved performance compared to the quantization table and the adjusted Huffman table of JPEG standard.

Development of High Speed Satellite Data Acquisition System

  • Choi, Wook-Hyun;Park, Sang-Jin;Seo, In-Seok;Park, Won-Kyu
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.280-282
    • /
    • 2003
  • The downlink data rates of the space-born payloads such as high-resolution optical cameras, synthetic aperture radars (SAR) and hyper-spectral sensors are being rapidly increased. For example, the image transmission rates of KOMPSAT-2 MSC(Multi-Spectral Camera) is 320Mbps even if on-board image compression scheme is used.[1] In the near future, the data rates are expected to be a level 500${\sim}$600Mbps because the required resolution will be higher and the swath width will be increased. This paper describes many techniques they enable 500Mbps data receiving and archiving system.

  • PDF

Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application (비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교)

  • Kim, Byung-Hyuk;Jung, Han;Kim, Young-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.