• 제목/요약/키워드: Optical Probe

검색결과 597건 처리시간 0.026초

Development of an Optical Waveguide Loss Measuring System using an Rectangular Glass Probe

  • Choi, Young-Kyu
    • 센서학회지
    • /
    • 제10권1호
    • /
    • pp.71-79
    • /
    • 2001
  • The use of a glass-plate probe of rectangular shape is proposed for the measurement of transmission loss in optical waveguides. The light-collecting window is of a thin, rectangular shape and is perpendicular to the light streak, while the conventional fiberglass probe has a small circular face. This transversely elongated form results in a grate improvement of mechanical tolerance for the probe movement in the vortical as well as in the transverse direction. A theoretical investigation also presents a reasonable agreement with the experiments.

  • PDF

마이크로 광디스크 드라이브용 4 × 1 근접장 탐침 어레이를 위한 슬라이더와 서스펜션의 설계 (Design of the Slider and Suspension for 4 × 1 Near-field Probe Array in Micro Optical Disk Drives)

  • 홍어진;정민수;오우석;박노철;양현석;박영필
    • 한국소음진동공학회논문집
    • /
    • 제15권2호
    • /
    • pp.184-191
    • /
    • 2005
  • The near-field scanning micro scope (NSOM) technique is in the spotlight as the next generation storage device. Many different types of read/write mechanism for NSOM have been introduced in the literature. In order for a near-field probe to be successfully implemented in the system, a suitable slider and suspension are needed to be properly designed. The optical slider is designed considering near-filed optics and probe array. The suspension generally supports slider performance, and tracking servo capacity in HDD. Moreover, the suspension for optical slider also should meet the optical characteristics, and is also required to satisfy shock performances for the mobility for the actuator. In this study, the optical slider and the suspension for near-field probe array are designed and analyzed.

마이크로 광디스크 드라이브용 4x1 근접장 탐침 어레이를 위한 슬라이더와 서스펜션의 설계 (Design of the Slider and Suspension for 4x1 Near-field Probe Array in Micro Optical Disk Drives)

  • 홍어진;정민수;오우석;박노철;양현석;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.393-398
    • /
    • 2004
  • The near-field scanning micro scope (NSOM) technique is in the spotlight as the next generation storage device. Many different types of read/write mechanism for NSOM have been introduced in the literature. In order for a near-field probe to be successfully implemented in the system, a suitable slider and suspension are needed to be properly designed. The optical slider is designed considering near-filed optics and probe array. The suspension generally supports slider performance, and tracking servo capacity in HDD. Moreover, the suspension for optical slider also should meet the optical characteristics, and is also required to satisfy shock performances for the mobility for the actuator. In this study, the optical slider and the suspension fer near-field probe array are designed and analyzed.

  • PDF

$CO_2$ 레이저를 이용한 광섬유 탐침(Optical probe)의 제작 (Manufacture of Optical Probe Using $CO_2$ Laser)

  • 신율;김영일;황보승
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1058-1061
    • /
    • 2004
  • 미세 소자를 관측, 가공 및 분석하기 위해 사용되는 기존 광학현미경은 빛으로 물체를 관측하므로 대물렌즈 (Object lens)에서의 회절한계 때문에 분해능의 있으므로 매우 뽀족한 탐침(Probe)을 시료의 표면에 근접시킨 후 표면을 주사하여 이미지를 얻는 방법이 개발되어 최근에는 Optical Fiber를 이용하여 fiber 끝단을 nano-scale 정도로 첨예화시키는 기술이 개발되었다. 이러한 광섬유 탐침은 구경의 직경이 작을수록 높은 분해능을 얻을 수 있으므로 광섬유 탐침의 제작 공정 확립은 매우 중요하다. 그 중에서 대표적인 방법이 $CO_2$ 레이저를 이용하여 가열한 후 인장 하는 방법 (Heating and Pulling)이 있다. 그래서 본 연구에서는 $CO_2$ 레이저를 이용하여 100nm 정도의 팁 반경을 갖는 뽀족한 탐침을 제작하고자 한다.

  • PDF

Noninvasive Hematocrit Monitoring Based on Parameter-optimization of a LED Finger Probe

  • Yoon, Gil-Won;Jeon, Kye-Jin
    • Journal of the Optical Society of Korea
    • /
    • 제9권3호
    • /
    • pp.107-110
    • /
    • 2005
  • An optical method of measuring hematocrit noninvasively is presented. An LED Light with multiple wavelengths was irradiated on fingernail and transmitted light from the finger was measured to predict hematocrit. A finger probe contained an LED array and detector. Our previous experience showed that prediction accuracy was sensitive to reliability of the finger probe hardware and we optimized the finger probe parameters such as the internal color, detector area and the emission area of a light source based on Design of Experiment. Using the optimized finger probe, we developed a hematocrit monitoring system and tested with 549 persons. For the calibration model with 368 persons, a regression coefficient of 0.74 and a standard deviation of 3.67 and the mean percent error of $8\%$ were obtained. Hematocrits for 181 persons were predicted. We achieved a mean percent error of $8.2\%$ where the regression coefficient was 0.68 and the standard deviation was 3.69.

Optimized Working Distance of a Micro-optic OCT Imaging Probe

  • Kim, Da-Seul;Moon, Sucbei
    • Current Optics and Photonics
    • /
    • 제4권4호
    • /
    • pp.330-335
    • /
    • 2020
  • We have investigated optimization of the working distance (WD) for a highly miniaturized imaging probe for endoscopic optical coherence tomography (OCT). The WD is the axial distance from the distal end of the imaging probe to its beam focus, which is demanded for dimensional margins of protective structures, operational safety, or full utilization of the axial imaging range of OCT. With an objective lens smaller than a few hundred micrometers in diameter, a micro-optic imaging probe naturally exhibits a very short WD due to the down-scaled optical structure. For a maximized WD careful design is required with the optical aperture of the objective lens optimally filled by the incident beam. The diffraction-involved effect was taken into account in our analysis of the apertured beam. In this study, we developed a simple design formula on the maximum achievable WD based on our diffraction simulation. It was found that the maximum WD is proportional to the aperture size squared. In experiment, we designed and fabricated very compact OCT probes with long WDs. Our 165-㎛-thick fiber-optic probes provided WDs of 3 mm or longer w ith reasonable OCT imaging performance.

The Optical Design of Probe-type Microscope Objective for Intravital Laser Scanning CARS Microendoscopy

  • Rim, Cheon-Seog
    • Journal of the Optical Society of Korea
    • /
    • 제14권4호
    • /
    • pp.431-437
    • /
    • 2010
  • A stack of gradient-index (GRIN) rod lenses cannot be used for coherent anti-Stokes Raman scattering (CARS) microendoscopy for insertion to internal organs through a surgical keyhole with minimal invasiveness. That's because GRIN lens has large amount of inherent chromatic aberrations in spite of absolutely requiring a common focus for pump and Stokes beam with each frequency of ${\omega}_p$ and ${\omega}_S$. For this endoscopic purpose, we need to develop a long slender probe-type objective, namely probe-type microscope objective (PMO). In this paper, we introduce the structure, the working principle, and the design techniques of PMO which is composed of a probe-type lens module (PLM) and an adaptor lens module (ALM). PLM is first designed for a long slender type and ALM is successively designed by using several design parameters from PLM for eliminating optical discords between scanning unit and PLM. A combined module is optimized again to eliminate some coupling disparities between PLM and ALM for the best PMO. As a result, we can obtain a long slender PMO with perfectly diffraction-limited performance for pump beam of 817 nm and Stokes beam of 1064 nm.

치석 진단용 소형 프로브 기반 광간섭단층촬영 시스템 (A Handheld Probe Based Optical Coherence Tomography System for Diagnosis of Dental Calculus)

  • 이창호;우채경;정웅규;강현욱;오정환;김지현
    • 센서학회지
    • /
    • 제21권3호
    • /
    • pp.217-222
    • /
    • 2012
  • Optical coherence tomography(OCT) is a noninvasive optical imaging tool for biomedical applications. OCT can provide depth resolved two/three dimensional morphological images on biological samples. In this paper, we integrated an OCT system that was composed of an SLED(Superluminescent Light Emitting Diode, ${\lambda}_0$=1305 nm bandwith= 141 nm), a reference arm adopting a rapid scanning optical delay line(RSOD) to get high speed imaging, and a sample arm that used a micro electro mechanical systems(MEMS) scanning mirror. The sample arm contained a compact probe for imaging dental structures. The performance of the system was evaluated by imaging in-vivo human teeth with dental calculus, and the results indicated distinct appearance of dental calculus from enamel, gum or decayed teeth. The developed probe and system could successfully confirm the presence of dental calculus with a very high spatial resolution($6{\mu}m$).

UV 임프린트 공정을 이용한 평면 광회로 기반 형광 산소 센서 프로브 모듈 제작 (Fabrication of Fluorescent Oxygen Sensor Probe Module Based on Planner Lightwave Circuits using UV Imprint Lithography)

  • 안기도;오승훈
    • 마이크로전자및패키징학회지
    • /
    • 제25권3호
    • /
    • pp.37-41
    • /
    • 2018
  • 본 논문에서는 UV 임프린트 기반의 평면 광 회로층을 이용한 산소농도 검출용 집적형 형광 프로브 모듈을 제안하였다. 제안된 형광 프로부 모듈은 광원과 형광 신호를 고효율로 전송할 수 있게 동일 광 경로를 가지는 비대칭 $1{\times}2$ 빔 분배기 형태로 설계되었으며, 이를 UV 임프린트 공정을 통해 제작하였다. 제작된 광 회로층의 끝단에 최적의 형광 염료 농도로 센서막을 코팅하여 산소 농도 검출용 광학 프로브 모듈을 구현하였다. 제작된 형광 프로부 모듈을 이용한 산소 농도 측정용 센서 시스템은 0%에서 20%의 가스 농도 범위에서 약 0.3%의 분해능까지 산소 농도를 검출 할 수 있었다. 이러한, 평면 광회로 기반의 형광 프로브 모듈은 저가의 집적형 산소 센서 검출 시스템을 가능하게 하여, 화학분야, 바이오 분야, 그리고 대기 및 수질 환경을 모니터링 하는 분야에 적용될 수 있을 것으로 기대된다.

Coated conductor에서 magneto-optical image와 scanning hall probe를 이용한 flux profile의 측정 및 분석 (Measurement and Analysis of the Flux Profiles of the Coated Conductors using Magneto-optical Image and Scanning Hall Probe)

  • 이효연;곽기성;이준규;유재은;염도준
    • Progress in Superconductivity
    • /
    • 제11권2호
    • /
    • pp.128-134
    • /
    • 2010
  • The magnetic flux profiles in SmBCO and YBCO coated conductors(CC) in the presence of the external field were comparatively investigated by magneto-optic image and scanning hall probe measurements. The current distributions calculated by using the inversion method from measured field profiles show that the decrease of current densities near the edges of SmBCO CC is more significant than those of YBCO CC. Through the comparison of the numerical analysis based on Kim's critical state model and the Brandt and Indenbom's solution, we found that this feature is related to their different field dependant properties of the critical current densities.