• 제목/요약/키워드: Optical Nonlinear Effect

검색결과 114건 처리시간 0.024초

Power Characteristics of cw Second-harmonic Generation in Periodically Poled LiNbO3

  • Kang, Bong-Hoon;Joo, Gi-Tae;Rhee, Bum-Ku
    • 한국세라믹학회지
    • /
    • 제47권5호
    • /
    • pp.430-432
    • /
    • 2010
  • We verified through a noncritical phase-matched second-harmonic generation experiment that the periodically-poled $LiNbO_3$ (PPLN) had a large effective nonlinear optical coefficient, demonstrating that the QPM grating was uniform throughout the entire length of PPLN. The quasi-phase matching temperature was $193.4^{\circ}C$. The maximum SHG output power at the fundamental power of 2.0 W was found to be 18.0 mW; generated second-harmonic beam was found to have no photorefractive effect.

표면 플라즈몬 공명에 의한 에탄올의 농도 및 굴절률 분석 (Analysis of ethanol concentration and refractive-index by use of surface plasmon resonance effect)

  • 도용화;이관수;송석호;손대원;이상선
    • 한국광학회지
    • /
    • 제13권1호
    • /
    • pp.9-14
    • /
    • 2002
  • 감쇠 전반사(attenuated total reflection)를 이용하여 액체의 농도 변화를 측정할 수 있는 표면 플라즈몬 공명 센서를 제작하였다. 센서의 구조는 프리즘 밑면에 금속 박막을 코팅하고 그 밑에 유전체론 접촉시킨 Kretschmann-Raether타입으로 하였고, 금속 박막으로는 센서 물질로 적합한 은(Ag) 박막을 사용하였다. 본 센서의 특성은 일반적으로 금속 박막의 두께에 영향을 받는데, 이론적 분석을 통하여 은 박막의 경우 54 nm의 두께에서 매우 좋은 특성을 나타냄을 알 수 있었다. 물과 에탄올을 혼합한 용액에서 에탄올의 농도를 변화시켜 가며 이에 따른 보면 플라즈몬 공명 각을 측정하였고, 표면 플라즈몬 공명 각의 변화로부터 혼합 용액의 농도 변화를 구하였다. 에탄올의 농도가 증가하여 50% 질량비 가지 변하는 구간에서 SPR센서가 매우 좋은 특성을 보였으며, 에탄올의 농도 변화를 3$\times$$10^{-2}$ % 질량비 가지 측정할 수 있었다. 또한 물과 에탄올을 혼합한 용액의 굴절률이 용액의 농도 변화에 따라 비선형적으로 변함을 관측하였으며, 물과 에탄을 혼합 용액의 농도에 따른 밀도 변화를 이용해 굴절률 변화의 비선형적 경향을 설명할 수 있었다.

유기염료가 복합화된 타이타니아 박막재료의 이차비선형광학특성에 관한 연구 (Second-Order Nonlinear Optical Properties of Organically Modified Titania Thin Film)

  • 임선진;곽현태;최동훈;박수영;김낙중
    • 한국재료학회지
    • /
    • 제4권4호
    • /
    • pp.466-471
    • /
    • 1994
  • 타이타니움이소프로폭사이드의 가수분해로 타이타니아 졸용액을 제조하고 그 특성을 조사하였다. 용매, 촉매 그리고 물의 양이 졸의 안정도에 미치는 영향을 조\ulcorner고, 서로 다른 온도에서 졸용액의 전단점도를 측정하여 그 각각의 gel time을 알아보았다. 안정한 조성의 졸용액을 이용하여 광학적으로 투명하고 균일한 타이타니아 박막을 제조할 수 있었다. 또한, 이차비선형 활성단을 도입한 후에도 좋은 박막을 제조할 수 있었다. 제조된 박막은 3~5kV, 50~$100^{\circ}C$ 온도범위에서 코로나 분극처리 하였다. 632.8nm He-Ne레이저를 이용하여 측정한 일차 전기 광학 상수, $r_{33}$는 1.5~5pm/V로서 경시 안정성을 나타내었다.

  • PDF

Z-scan 방법에 의한 비정질 $As_2S_3$ 박막의 비선형 굴절률 측정 (Nonlinear refractive index measurement for amorphous $As_2S_3$ thin film by Z-scan method)

  • 김성규;이영락;곽종훈;최옥식;이윤우;송재봉;서호형;이일항
    • 한국광학회지
    • /
    • 제9권5호
    • /
    • pp.342-347
    • /
    • 1998
  • 비선형 Kerr 매질을 통과하는 Gaussian 빔에 대해 aberration-free approximation과 Huygens-Fresnel 회절 이론을 적용하여 Z-scan 투과율에 대한 해석해를 유도하였다. 비정질 $As_2S_3$ 박막에 대해 Z-scan 실험을 수행하였으며 이론과 비교하여 잘 일치함을 알았다. 633nm 파장에서 측정된 비선형 굴절률${\gamma}$의 크기와 기호 $+8.65{\times}10^{-6}\textrm{cm}^2/W$이며, 또한 먼 영역(far-field)에서 빔 세기분포를 측정하여 자기 집광(self-focusing)효과를 가시적으로 확인하였다.

  • PDF

SMF와 DCF의 길이와 분산 계수가 불규칙하게 분포하는 분산 제어 링크 (Dispersion-managed Links with the Irregular Distribution of the Lengths and Dispersion Coefficients of the SMFs and the DCFs)

  • 이성렬
    • 한국항행학회논문지
    • /
    • 제22권3호
    • /
    • pp.240-245
    • /
    • 2018
  • 전체 광 중계 구간 모두 불규칙한 분산 계수를 갖는 단일 모드 광섬유와 분산 보상 광섬유 (DCF; dispersion compensating fiber)를 이용한 융통적인 분산 제어 링크 구조를 제안하였다. 링크의 융통적 구성은 각 전송 반 구획에서 DCF의 분산 계수를 기준으로 이들을 인위적으로 분포시켜서 가능하게 하였다. 광 위상 공액기 전의 전송 반 구획에서는 DCF의 분산 계수를 점진적으로 증가시키고, 광 위상 공액기 다음의 전송 반 구획에서는 DCF의 분산 계수를 점진적으로 감소시키는 'AD' 분포에서 왜곡된 파장 분할 다중(WDM; wavelength division multiplexed) 신호가 최상으로 보상되는 것을 확인하였다. 따라서 왜곡된 WDM 채널의 보상 효과를 더욱 증가시키기 위해서는 광섬유의 길이, 중계 구간 당 잉여 분산뿐만 아니라 광섬유의 분산 계수에 상관없이 'AD' 분포를 선택할 필요가 있다는 것을 확인하였다.

Ti:PPLN 광도파로를 이용한 비선형광학 기반의 의사 위상정합 2차 조화파 발생 (Quasi Phase-Matched Second Harmonic-Wave Generation based on Nonlinear-Optic Effect Utilizing Ti:PPLN Optical Waveguides)

  • 정홍식;정영식
    • 한국광학회지
    • /
    • 제19권6호
    • /
    • pp.408-415
    • /
    • 2008
  • 고전압 펄스를 인가시켜서 주기적으로 도메인을 반전시키는 공정을 검토하였으며, 이를 적용해서 제작된 Ti 확산 리튬나오베이트 채널광도파로(Ti:PPLN) 기반의 의사 위상정합 2차 조화파 발생을 체계적으로 측정하였다. 2차 조화파 발생을 위해서 $16.6{\mu}m$ 분극 주기와 49 mm 길이의 Ti:PPLN 채널광도파로를 제작하였으며, 473(%/W) 변환효율이 측정되었다.

Evaluation of Chromatic-Dispersion-Dependent Four-Wave-Mixing Efficiency in Hydrogenated Amorphous Silicon Waveguides

  • Kim, Dong Wook;Jeong, Heung Sun;Jeon, Sang Chul;Park, Sang Hyun;Yoo, Dong Eun;Kim, Ki Nam;An, Shin Mo;Lee, El-Hang;Kim, Kyong Hon
    • Journal of the Optical Society of Korea
    • /
    • 제17권5호
    • /
    • pp.433-440
    • /
    • 2013
  • We present an experimental and numerical study of spectral profiles of effective group indices of hydrogenated amorphous silicon (a-Si:H) waveguides and of their chromatic-dispersion effect on the four-wave-mixing (FWM) signal generation. The a-Si:H waveguides of 220-nm thickness and three different widths of 400, 450 and 500 nm were fabricated by using the conventional CMOS device processes on a $2-{\mu}m$ thick $SiO_2$ bottom layer deposited on 8-inch Si wafers. Mach-Zehnder interferometers (MZIs) were formed with the a-Si:H waveguides, and used for precise measurement of the effective group indices and thus for determination of the spectral profile of the waveguides' chromatic dispersion. The wavelength ranges for the FWM-signal generation were about 45, 75 and 55 nm for the 400-, 450- and 500-nm-wide waveguides, respectively, at the pump wavelength of 1532 nm. A widest wavelength range for the efficient FWM process was observed with the 450-nm-wide waveguide having a zero-dispersion near the pump wavelength.

PMP 형상 측정법에서 비선형 오차보정에 관한 연구 (A study on the nonlinear error correction of the phase measuring profilometry)

  • 황용선;강영준;박낙규;백성훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.513-516
    • /
    • 2003
  • Phase Measuring Profilometry(PMP) has been developed as one of three dimensional 3-D shape measuring methods. The 3-D profile of an object was calculated from the phase data obtained by the sinusoidal patterns projected on the object. However, in some cases the approximation includes considerable errors. In this paper, the effect on the errors caused by the optical geometry and the calibration procedure in PMP technique are discussed. The errors which occured in the process of calculating the 3-D profile from the phase distribution are investigated theoritically and experimentally.

  • PDF

NFR 슬라이더의 동특성 분석 (Dynamic Analysis of NFR Slider)

  • 안채헌;임경화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.586-591
    • /
    • 2001
  • Dynamic analysis using impulse responses is formulated to estimate effect of slider rail shape on dynamic responses. Impulse responses are obtained on numerical nonlinear model including rigid motion of slider and fluid motion of air bearing under the slider. Dynamic characteristics of slider motion are evaluated by utilizing the decay ratio of impulse responses and modal frequencies from frequency response functions. The dynamic characteristics of the developed NFR(Near Field Recording) slider are checked by comparing those of HDD sider(Nutcracker). Also, sensitivities of slider position conditions and rotation speed on the dynamic characteristics are investigated. The researches show that the utilized method is a good indicator of designing the better slider.

  • PDF

근적외분광분석법을 이용한 생쥐꼬리에서의 비침습 혈당 정량시 장기간 측정에 따른 변이 요인의 보정 (Compensation of Variation from Long-Term Spectral Measurement for Non-invasive Blood Glucose in Mouse by Near-Infrared Spectroscopy)

  • 백주현;강나루;우영아;김효진
    • 약학회지
    • /
    • 제48권3호
    • /
    • pp.177-181
    • /
    • 2004
  • Non-invasive blood glucose measurement from mouse tail was performed by near-infrared (NIR) spectroscopy. Three groups; normal, type I diabetes (insulin dependent diabetes mellitus, IDDM), type II diabetes (non-insulin dependent diabetes mellitus, NIDDM) group, were studied over a 10 weeks period with the collection of near-infrared (NIR) spectra. Spectral variations from long-term measurement (10 weeks) from dramatic and nonlinear changes in the optical properties of the live tissue sample were compensated by chemometrics techniques such as principle component analysis (PCA) and partial least squares (PLS) regression. The effect from mouse body temperature changes on NIR spectral data was also considered. This study showed that the compensation of variations from long-term measurement and temperature changes improved calibration accuracy of non-invasive blood glucose measurement.