• 제목/요약/키워드: Optical Mirror

검색결과 761건 처리시간 0.029초

형광과 여기광을 공간적으로 분리하는 바이오칩용 소형 형광측정시스템 (Miniature Biochip Fluorescence Detection System with Spatial Separation of Fluorescence from Excitation Light)

  • 김호성;김용권;박주한;이국녕;최재호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.378-383
    • /
    • 2005
  • We report the development of miniature fluorescence detection systems that employ miniature prism, mirrors and low coat CCD camera to detect the fluorescence emitted from 40 fluorescently-labeled protein patterns without scanner. This kind of miniature fluorescence detection system can be used in point of care. We introduce two systems, one uses prism+mirror block and the other uses prism and two mirrors. A large NA microscope eyepiece and low cost CCD camera are used. We fabricated protein chip containing multi-pattern BSA labeled with Cy5, using MEMS technology and modified the surface chemically to clean and to immobilize proteins. The measurements show that the combination of prism and mirrors can homogenize elliptical excitation light over the sample with higher optical efficiency, and increase the separation between excitation and fluorescence light at the CCD to give higher signal intensity and higher signal to noise ratio. The measurements also show that protein concentrations ranging from 10 ng/ml to 1000 ng/ml can be assayed with very small error. We believe that the proposed fluorescence detection system can be refined to build a commercially valuable hand-held or miniature detection device.

광기록 장치의 픽업헤드용 2.4mm 크기의 미러의 제작과 구동실험 (Fabrication and driving experiment of 2.4mm size mirror for optical pick-up head)

  • 박근우;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2266-2268
    • /
    • 2000
  • 본 논문에서는 스캐닝 미러의 일종으로, 광저장 장치의 픽업헤드용으로 미세회전을 하면서 레이저 빔을 편향시키는 용도로 사용되는 미러를 제작하고 구동실험을 하였다. 제작된 미러의 크기는 $2400{\times}2400{\times}64{\mu}m^3$이고, 빔 스프링은 $500{\times}9.6{\times}64{\mu}m^3$이다. 니켈 전해 도금으로 29${\mu}m$ 높이의 구동 전극을 제작하였고(세가지 모델: 공기통로가 없는 전극, 공기통로와 간격이 각각 200${\mu}m$인 전극, 공기통로와 간격이 각각 100${\mu}m$인 전극), 미러판과 전극을 조립하여(미러판과 전극 사이의 간격은 각각 29${\mu}m$, 26${\mu}m$, 26${\mu}m$) 구동실험을 하였다. 공진 주파수의 계산간은 576Hz, 측정값은 3개의 미러에서 모두 568Hz이었다. 전극과 미러판의 간격이 최대 접근거리 18${\mu}m$가 되도록 미세 회전을 시켰을 때, 공기통로가 없는 전극에서는 공진 주파수가 524Hz, 공기통로가 200${\mu}m$인 전극에서는 544Hz로 각각 감쇠되었고, 공기통로가 100${\mu}m$인 전극에서는 그대로 568Hz이었다.

  • PDF

곡률에 근거한 형상 측정기술 개발 (Development of Profilometry based on a Curvature Measurement)

  • 김병창
    • 한국광학회지
    • /
    • 제18권2호
    • /
    • pp.130-134
    • /
    • 2007
  • 광역의 자유곡면 형상을 나노미터 정밀도로 측정하기 위한 새로운 형상 측정법으로서 곡률에 근거한 형상 측정법을 제안한다. 곡률 형상 측정기는 피측정물을 일정간격으로 스캔하는 간섭계로써 각 국부영역의 형상으로부터 곡률을 획득하여, 이로부터 전 영역의 형상을 복원한다. 제안된 곡률 형상 측정기는 비구면 형상 측정을 위해 개발된 보상 광학계(Null optics)나 국부영역의 형상을 측정하고 결합하는 subaperture-slicking 법에 비해 측정 장비로부터 발생하는 시스템 오차를 근본적으로 제거하는 특징을 가진다. $80mm\times80mm\times25mm$ 작동구간을 갖는 Stewart Platform과 상용 트와이만 그린 간섭계를 이용하여 곡률간섭계를 구성하였으며, 자유곡면의 형상측정을 위한 첫 단계로서 잘 알려진 구면형상을 측정하고, 기존 장비의 측정값과 비교한 결과 32 mm영역에서 최대 56 nm의 차를 보임을 확인하였다.

HWE 방법에 의한 ZnSe/GaAs(100)의 성장과 특성 (Growth and characterization of ZnSe/GaAs(100) by hot-wall technique)

  • 전경남;고석룡;이경준;정원기;두하영;이춘호
    • 한국결정성장학회지
    • /
    • 제6권1호
    • /
    • pp.56-61
    • /
    • 1996
  • 두 개의 증발료가 설치된 hot wall epitaxy 장치를 제작하고 GaAs 기판위에 undoped ZnSe 박막을 성장하였다. 기판온도 $350^{\circ}C$, 원료부의 온도 $660^{\circ}C$ 근방에서 성장된 경 연박막의 XRD 측정값은 175 $sec^{-1}$의 반치폭을 냐타내 였다. Photoluminescence 측정 결과 neu t tral acceptor bound exciton emission line이 강하게 얻어지는 양질의 박막을 성장하였다.

  • PDF

Bowl-feed 연마기법에 의한 초연마 반사경 기판의 표면 거칠기 특성 (Surface roughness characteristics of the super-polished)

  • 조민식
    • 한국광학회지
    • /
    • 제11권5호
    • /
    • pp.312-316
    • /
    • 2000
  • Bowl-feed식 연마공정에 의한 초연마 반사경 기판의 표면 거칠기 특성이 전통적인 fresh-feed식 연마공정의 경우와 비교하여 조사하였다. Bowl-feed식 연마기법에 의해 가공된 반사경 기판의 표면 거칠기는 fresh-feed식 연마공정에 비해 약 3배 개선되었으며, 표면 거칠기 RMS값의 경우 $0.5\AA$이하, 최고 $0.3\AA$의 양호한 결과를 얻었다. 또한, 연마된 반사경 기판의 1차원 표면 거칠기 분포도와 표면 거칠기 amplitude spectrum으로부터 fresh-feed 공정에 대한 bowl-feed 연마공정의 기판표면구조 변화상태가 분석되었다.

  • PDF

렌즈형 레이저 막대들로 구성된 대칭형 Nd:YAG 레이저의 출력 특성 분석 (Output characteristic analysis of the symmetric Nd:YAG laser consisted of two laser rods with rod-end curvatures)

  • 김현수;이성만;이용주
    • 한국광학회지
    • /
    • 제17권2호
    • /
    • pp.198-202
    • /
    • 2006
  • 두개의 렌즈형 Nd:YAG 막대들로 구성된 두 종류의 대칭형 레이저 공진기에 대한 공진기 안정도, 빔질 특성($M^2$)과 레이저 출력 등을 비교 분석하였다. 실험은 두개의 레이저 막대를 서로 근접시킨 구조의 레이저와 레이저 막대가 레이저 거울에 각각 거의 밀착된 구조의 레이저를 이용하여 수행하였다. 또한복굴절 보상 소자를 두 종류의 공진기에 사용했을 때의 레이저 출력 특성도 비교 분석하고 수치 해석하였다.

A Single Lens Micro-Angle Sensor

  • Saito, Yusuke;Gao, Wei;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권2호
    • /
    • pp.14-19
    • /
    • 2007
  • Angle sensors based on the principle of autocollimation, which are usually called autocollimators, can accurately measure small tilt angles of a light-reflecting flat surface. This paper describes a prototype micro-angle sensor that is based on the laser autocollimation technique. The new angle sensor is compact and consists of a laser diode as the light source and a quadrant photodiode as a position-sensing device. Because of its concise design, the microangle sensor facilitates dynamic measurements of the angular error motions of a precision stage without influencing the original dynamic properties of the stage. This is because the sensor only requires a small extra target mirror to be mounted on the stage. The sensitivity of the angle detection is independent of the focal length of the objective lens; therefore, an objective lens with a relatively short focal length is employed to reduce the size of the device. The micro-angle sensor uses a single lens for the both the laser collimation and focusing, which distinguishes it from the conventional laser autocollimation method that has separate collimate and objective lenses. The new micro-angle sensor has dimensions of $15.1\times22.0\times14.0mm$ and its resolution is better than 0.1 arc-second The optical design and performance of this micro-angle sensor were verified by experimental results.

Straylight analysis for preliminary filter and baffle design for New Generation GOCI

  • Oh, Eun-Song;Ahn, Ki-Beom;Jung, Kil-Jae;Ryu, Dong-Ok;Kim, Sug-Whan
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2010년도 한국우주과학회보 제19권1호
    • /
    • pp.25.4-26
    • /
    • 2010
  • We present a three-mirror anastigmat(TMA) optical system for New Generation GOCI. In order to reduce the ghost optimized filter and baffle. By using carefully chosen antireflective coating and tilted filter angle, we fulfilled the design SNR requirement of 1500. We then designed a new entrance baffle and an internal baffle capable of producing the ghost ratio better than 0.01% of the nominal signal. The entrance baffle limits FOV to $0.75^{\circ}$ (E/W) $\times$ $0.60^{\circ}$ (S/N), and prevents the system from strong sun illumination, and the internal baffle prevents stray and scattered ray from entering into the telescope cavity. From these filter and baffle design, we confirmed that the instrument signal to noise ratio can be met with the current conceptual opto-mechanical design.

  • PDF

후두미세수술의 역사와 기구의 발전 (History and Instrumental Development of Laryngeal Micro-Surgery)

  • 우주현;김동영
    • 대한후두음성언어의학회지
    • /
    • 제21권2호
    • /
    • pp.97-100
    • /
    • 2010
  • After introduction of operating microscopes and laser devices in the 1960's, monumental innovation for had been achieved in laryngeal microscopic surgery. The development of high-tech operating devices made the laryngeal surgery less invasive and more precise. There were long histories until developing of the modem instruments and surgical techniques. The simple oral mirror introduced by Bozzoni in 1807 is the beginning of laryngoscope. In 1859 Green carried out the laryngeal operation under direct view of larynx. The appearance of local topical anesthesia on throat had contributed to laryngeal surgery coming into wide use. Killian and Jackson made much contribution to developing the design of laryngoscope. After that, modem laryngeal surgery have been developed with development of the stabilizing holder of laryngoscope and optical devices. We propose carefully the direction of the development of the laryngeal surgery by historical consideration of laryngeal surgery and instrumental development.

  • PDF

300-W-class Side-pumped Solar Laser

  • Qi, Hongfei;Lan, Lanling;Liu, Yan;Xiang, Pengfei;Tang, Yulong
    • Current Optics and Photonics
    • /
    • 제6권6호
    • /
    • pp.627-633
    • /
    • 2022
  • To realize uniform side pumping of solar lasers and improve their output power, a solar concentrating system based on off-axis parabolic mirrors is proposed. Four identical off-axis parabolic mirrors with focal length of 1,000 mm are toroidally arranged as the primary concentrator. Four two-dimensional compound parabolic concentrators (2D-CPCs) are designed as a secondary concentrator to further compress the focused spot induced by the parabolic mirrors, and the focused light is then homogenized by four rectangular diffusers and provides uniform pumping for a laser-crystal rod to achieve solar laser emission. Simulation results show that the solar power received by the laser rod, uniformity of the light spot, and output power of the solar laser are 7,872.7 W, 98%, and 351.8 W respectively. This uniform pumping configuration and concentrator design thus provide a new means for developing high-power side-pumped solid-state solar lasers.