Beach Profile Estimation Using a Photogrammetry (사진측정법을 이용한 해빈단면의 추정)

  • Kim, Baeck-Oon;Park, Yong-Ahn;Oh, Im-Sang;Khim, Boo-Keun;Choi, Kyung-Sik
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.3 no.4
    • /
    • pp.228-233
    • /
    • 1998
  • This study presents a close-range photogrammetry that is applicable to beach profile estimation using a non-metric camera. Based on the analysis of oblique video image in which the video camera was installed on a horizontal plane and the field of view was fixed, a new equation to analyze a photograph was developed considering the following aspects: (1) camera is allowed to be rotated about its optical axis and (2) a simple error model is adopted to correct lens distortion and other systematic errors associated with the non-metric camera, which improves accuracy of non-metric imageries. To test the modified technique, photographs of the beach were taken near the Donghae City in February, 1998. In addition, beach profiles were surveyed with conventional dumpy level and surveying staff. RMS error between the estimated and measured beach profiles is less than 10 cm in elevation.

  • PDF

A Study on the PZT Application for Spacecraft Components under Space Environment (우주환경하의 위성부품용 압전진동자 활용에 관한 연구)

  • Lee, Sang-Hoon;Moon, Guee-Won;Yoo, Seong-Yeon
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.6
    • /
    • pp.287-294
    • /
    • 2012
  • In the high vacuum condition of the space, outgassing from any assembly of satellite can contaminate satellites, especially second surface mirror and optical lens, it cause satellite to fail in own missions. Therefore, all unit shall be check for compatibility with vacuum using CVCM (Collected Volatile Condensable Material) and TML (Total Mass Loss) in advance. CVCM and TML of the PZT-5 piezoelectric ceramic vibrator has less than 0.1% and 1.0% respectively. Also, it has less than 500 $ng/cm^2/hr$ of Thermoelectric Quartz Crystal Microbalance for vacuum bake-out test using high temperature(more than $80^{\circ}C$) and high vacuum (less than $5.0{\times}10^{-3}$ Pa). Thus, piezoelectric ceramic vibrator may be employed in the vacuum environments. Finally, it can be confirmed that the characteristics change of the piezoelectric ceramic vibrator is less than 1% under vacuum environments.

Characteristics of the Nd:YAG laser with stimulated brillouin scattering phase conjugate mirror (유도 브릴루앙 산란 위상공액 거울을 이용한 Nd:YAG 레이저 발진기의 출력특성)

  • 이동원;이성구;박승현;공홍진
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.548-553
    • /
    • 2002
  • We have investigated the output characteristics of a Nd:YAG oscillator with a Stimulated Brillouin Scattering phase conjugation mirror (SBS-PCM). FC-75 is used as an SBS gain medium and Cr:YAG (T=50%) as a Q-switcher. The SBS-PCM consists of an SBS-cell and a simple plano-convex focusing lens system. For the case of not using a Q-switcher, an SBS-cell doesn't work as a phase conjugation mirror. For the case of using a Q-switcher, the energy characteristics remains nearly the same whether using the SBS-cell or not using it. The pulse width is reduced from 50 ns to 40 ns by an SBS-PCM. When the SBS-cell is used with a Q- switcher, the SBS-cell works very well as a phase conjugation mirror and its beam-profile is improved dramatically. And in order to explain the progression of beam-profile, we propose a simple model based on the nonlinear reflectivity of the SBS-PCM, whose reflectivity is dependent on the pumping intensity at the focal plane.

Polymer Microlens Fabrication (폴리머 마이크로렌즈 제작)

  • Ryoo, Kunkul;Kim, Younggeun;Jeon, Kwangseok
    • Clean Technology
    • /
    • v.11 no.4
    • /
    • pp.205-211
    • /
    • 2005
  • There have been many technologies and materials proposed for realizing microlens array, and plastic injection is recognized as the most promising one because of several merits such as optical properties, impact resistance, formability, lightening and environmental adaptability. Since PR reflow for injection template fabrication enables the lens shape control easier, and the sample technology more effective for mass production, it lowers the cost, enhances integration, and reduces process steps, which leads to be environmentally benign. However injection of polymers may face the difficulty of formability depending on their properties. In order to overcome the difficulty, fast heating/cooling technology was introduced in this study, and microlenses were fabricated and evaluated. template obtained by PR reflow method was heated and cooled fast during injection to fabricate microlens array. PC and PMMA polymer materials were compared, and it was realized that PMMA showed much better formability due to its lower melting temperature. Injection parameters of pressures and velocities were driven out for injection optimization.

  • PDF

Fringe Sensitivity of Projection Moire Topography Due to Position of Light Source and Object Distance According to Grating Periods (영사식 무아레 토포그래피에서 격자 주기에 따른 물체거리와 광원의 위치에 대한 무늬 민감도 변화)

  • Oh, Hyun Seock;Ju, Yun Jae;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.2
    • /
    • pp.67-72
    • /
    • 2016
  • In projection moire topography, the investigation of fringe sensitivity, which means the change rate of fringe order according to object height, is important and necessary to reduce the measurement error of the shape of an object. Using the fringe sensitivity, the determination of the absolute orders of moire fringes can be performed very easily and rapidly. The important parameters in the determination of absolute orders of fringes are the positions of light source and object, and the grating period in projection moire topography. Among these parameters, the fringe sensitivity due to the transverse motion of the light source and the longitudinal motion of the object according to grating periods are analyzed and compared. As a result, whereas the fringe sensitivity in the transverse-motion method increases linearly and gradually as the distance between light source and imaging sensor increases, the fringe sensitivity due to the longitudinal-motion method decreases dramatically as the distance between imaging lens and object increases. In these methods, the fringe sensitivity and its change increase as the grating period increases.

Optical Properties of Color Conversion Lens for White LED Using B2O3-Bi2O3-ZnO Glass (B2O3-Bi2O3-ZnO계 유리를 이용한 백색 LED용 색변환 렌즈의 광 특성)

  • Chae, Yoo-Jin;Lee, Mi-Jai;Kim, Jin-Ho;Hwang, Jong-Hee;Lim, Tae-Young;Jeong, Hee-Suk;Lee, Young-Sik;Kim, Deuk-Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.8
    • /
    • pp.614-619
    • /
    • 2013
  • Recently, remote phosphor is reported for white LED enhancing of phosphor efficiency compared with conventional phosphor-based W-LED. In this study, Remote phosphor was produced by screen printing coating on glass substrate with phosphor contents rated paste and heat treatment. The paste consists of phosphor, lowest softening glass frit and organic binders. Remote phosphor can be well controlled by varying the phosphor content rated paste. After mounting remote phosphor on top of blue LED chip, CCT, CRI, and luminance efficiency were measured. The measurement results showed that CCT, CRI, and luminance efficiency were 6,645, 68, and 1,16l m/W in phosphor 80 wt.% remote phosphor sintered at $600^{\circ}C$.

Experimental Demonstration of Long-reach 2×2 Multiple-Input Multiple-Output (MIMO) Visible Light Communications Using an Image Sensor Receiver (이미지 센서 수신부를 이용한 장거리 2×2 MIMO LED 무선 가시광 통신 실험)

  • Jeon, Jong-Bae;Kim, Sung-Man
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8B
    • /
    • pp.706-711
    • /
    • 2012
  • The current visible light communication (VLC) systems have a short transmission distance and a low data rate. To overcome this, we studied on the method of appling MIMO technology to VLC. However, it is difficult to apply the original MIMO technology used in RF frequency to wireless VLC. In VLC system, a lens can be used to separate the transmitted signals. And, if we use an image sensor as the receiver, MIMO technology can be applied to LED wireless visible light communication. In this paper, we report an experiment of $2{\times}2$ LED wireless visible light communication using a commercial image sensor receiver. We show the experimental demonstration with a transmission length of 10.5 m and a data rate of 200 bit/s.

Physical Properties of Styrene Copolymer and Contact Lens Application (스타이렌 공중합체의 물리적 특성 및 콘택트 렌즈로의 응용)

  • Kim, Tae-Hun;Ye, Ki-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.755-760
    • /
    • 2009
  • Styrene is broadly used as a polymer and a copolymer and is useful in manufacturing contact lenses due to its high refractive index. This study used styrene with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Measurement of the physical characteristics of the copolymerized material showed that the refractive index is 1.4412 - 1.4628, water content 20 - 35%, visible transmittance 82.6 - 87% and the tensile strength 0.143 - 0.344 Kgf. Also, measurements showed that the refractive index and tensile strength increased while the water content decreased as the ratio of styrene increased. Based on the results of this study, the produced copolymer can be estimated to be suitable for use as a material for high performance functional contact lenses.

Solution to Slow Down Myopia Progression

  • Jung, Ji-Won
    • Journal of Korean Clinical Health Science
    • /
    • v.8 no.1
    • /
    • pp.1386-1397
    • /
    • 2020
  • Purpose: To examine the effectiveness of various treatments; bifocal spectacles, orthokeratology, atropine, and time spent in outdoors; in slowing down the myopia progression for Asian adolescents (6-18age). Methods: The research focused on examining the most effective treatment in controlling myopia based on the literature sources that have been published. Through meta-analysis of various research papers that already has been done in this field, a lot of data was collected. For each treatment, the difference in axial length and spherical equivalent over time was measured and recorded. To quantitatively record the difference, both axial length and spherical equivalent was determined by value of control group value of treatment group. The paper compared the effectiveness of each treatment based on the data that was measured. Results: Adolescents who chose to spend time outdoors in order to slow down myopia progression had axial length difference of 0.03 mm and spherical equivalent difference of 0.17 D. Adolescents that used atropine had axial length difference of 0.36 mm and spherical equivalent difference of 0.92 D. Bifocal spectacle resulted in axial length difference of 0.21 mm and spherical equivalent difference of 0.59 D, and for orthokeratology 0.23 mm and 0.04 D, respectively. Axial length wise, myopia was most controlled by the atropine since there was a greatest difference between the group that got the treatment and the group that did not have the treatment. According to the spherical equivalent difference data, myopia was most controlled by atropine. Conclusion: Atropine showed the most effective result in controlling myopia among the four treatment. Again, compared to other three treatment, using atropine appeared to have greatest ability in slowing down myopia progression since adolescents who were treated with atropine had greatest difference from adolescents in the control group that had the same condition but didn't get the treatment. However, every treatment was only used for 2 or 3 years which is quite short time period to measure the long term effect of the four treatments. Also, since atropine is a pharmaceutical method to control myopia, it may harm adolescents' eyes compared to optical or environmental treatment.

Polymerization and Optical Properties of Polymers with High Tensile Strength Added Isocyanate Group

  • Sung, A-Young;Ye, Ki-Hun
    • Journal of Integrative Natural Science
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Polyurethane resin containing isocyanate is marked by excellent tensile and mechanical strengths and this test aims to gauge its applicability as a medical high polymer. Tris [2-(acryloyloxy)ethyl]isocyanurate and hexamethylenediisocyanate were added to a basic mixing ratio of HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), NVP (n-vinyl-2-pyrrolidone) and crosslink agent, EGDMA (ethylene glycol dimethacrylate) with increasing proportions and copolymerized respectively. Also, the basic physical properties of the polymerized high polymers including refraction rate, tensile strength, light transmission and water content were measured to confirm that they are appropriate as hydrogelcontact lenses. After measuring the physical properties of high performance polymers produced by adding tris [2-(acryloyloxy) ethyl]isocyanurate, it was found that the average tensile strengths of sample TRIS1 to TRIS10 were between 0.285 and 0.612 kgf, while the average values of refractive index were ranged from 1.441 to 1.449 with water content from 30.00 to 37.35%.The measurement of physical properties of the copolymers generated by adding hexamethylenediisocyanate showed that the average tensile strength of sample HEXA1 to HEXA10 ranged from 0.267 to 1.742 kgf, the refractive index ranged from 1.443 to 1.475 and water contents were in the range of 21.22 to 35.58%. In all combinations the transmission rates satisfied the transmittance of general hydrogel contact lenses. From theresults, it is possible to conclude that the produced copolymers can be used as contact lens materials with excellent tensile strength.