• Title/Summary/Keyword: Optical Height

Search Result 347, Processing Time 0.031 seconds

Development of Wave Height Field Measurement System Using a Depth Camera (깊이카메라를 이용한 파고장 계측 시스템의 구축)

  • Kim, Hoyong;Jeon, Chanil;Seo, Jeonghwa
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.6
    • /
    • pp.382-390
    • /
    • 2021
  • The present study suggests the application of a depth camera for wave height field measurement, focusing on the calibration procedure and test setup. Azure Kinect system is used to measure the water surface elevation, with a field of view of 800 mm × 800 mm and repetition rate of 30 Hz. In the optimal optical setup, the spatial resolution of the field of view is 288 × 320 pixels. To detect the water surface by the depth camera, tracer particles that float on the water and reflects infrared is added. The calibration consists of wave height scaling and correction of the barrel distortion. A polynomial regression model of image correction is established using machine learning. The measurement results by the depth camera are compared with capacitance type wave height gauge measurement, to show good agreement.

Implementation of Optical-based Measuring Instrument for Overhead Contact Wire in Railway (전기철도 전차선로의 광학기반 형상 검측 하드웨어 구현)

  • Park, Young;Cho, Yong-Hyeon;Park, Hyun-June;Kwon, Sam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.518-518
    • /
    • 2008
  • We propose an optical-based measuring instrument of catenary system in electric railway. This system was made to utilize line scan camera as inspecting system to measure the stagger and height of overhead contact wire in railway and composed with optical type source and FPGA-based image acquisition system with PCI slot. Vision acquisition software has been used for the application to programming interface for image acquisition, display, and storage with a frequency of sampling. The proposed optical-based measuring instrument to measure the contact wire geometry shows promising on-field applications for online condition motoring. Also, this system can be applied to measure the hight and stagger or other geometry of different type of overhead catenary system.

  • PDF

Micro replication quality of Fresnel lens using UV imprinting process (UV 임프린팅을 통한 프레넬 렌즈 제작 시 미세 복제 특성에 관한 연구)

  • Lim,, Ji-Seok;Kim, Byung-Wook;Kang, Shin-Ill
    • Transactions of the Society of Information Storage Systems
    • /
    • v.6 no.1
    • /
    • pp.37-40
    • /
    • 2010
  • Fresnel lens is a kind of refractive optical lens with various advantages. It has nearly flat shaped optical lens that has small mass. Fresnel lens has number of applications in the compact optical systems. Recently, demands of high quality Fresnel lens for small size optical systems such as illumination units, compact imaging systems, display units, information storage systems, optical detecting units had increased rapidly. Conventional manufacturing process of high quality Fresnel lens is direct machining. However, it is not suitable for mass production because of high cost and long cycle time. Replication method can provide cost effective mass production process. However, there are various issues about replication of Fresnel lens. Fresnel lens has number of sharp blade shape prism. In the replication process, this blade shape causes defects that can affect optical efficiency. In this study, replication processes; injection molding process and UV imprinting process, were developed and evaluated using Fresnel lens that has maximum pattern height of $250\;{\mu}m$ and aspect ratio of 1.5.

The Effect of the Optical Points Difference between Finished-Reading Glasses and Dispensing Reading Glasses (완성품 돋보기와 조제가공된 돋보기가 광학적 요소에 미치는 영향)

  • Shim, Young-Cheol;Yoo, Gun-Chang;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.65-71
    • /
    • 2008
  • Purpose: This paper studied the effect of eyes on the comparison between the distance optical centers problem of dispensing reading glasses made by optician and finished reading glasses in the current market. Methods: The method of this study has been measured by eleven different categories from +1.00D to +4.00D. This study also separated into three groups by their optical frame size and measured optical center point (O.C) and optical center height (O.H) with 200 peoples of man and females over 40 years old without ocular disease living in Gwang-san gu, Gwang-Ju city. Results: As a result, optical center point ranged from 57 mm to 80 mm and it turned to be most common range is from 61 mm to 65 mm (64.6%). Moreover, the optical center height ranged from 1 mm to 8mm and most common ranged (23%) were 4 mm. In other words, finished reading glasses have irregular optical ranges. After observing 200 people who are over 40 years old men and women, result shows that more than 75.5% (151 people) currently use finished reading glasses. Survey of 151 people, most common error between the finished reading glasses's O.C and the wearers P.D were 4 mm (45%). Furthermore, the most common error between the finished reading glassses's O.H and the wearers O.H ranged from 3 mm to 4 mm. Astonishingly, the entire 151 people who wear finished reading glasses appeal that they feel tiredness on their eyes when they wear finished reading glasses. 53 people (35%) claimed that they feel tiredness on their eyes after 10 to 20 minutes wearing finished reading glasses. Base on the research, We conducted more experiment to find the value of prism of optical centers err because it will tell us whether the finished reading glasses are good enough to wear or not. We multiplied diopter by the difference between finished reading glasses's O.C. and wearer's P.D. Consequently, We found out that the finished reading glasses counter to the German RAL-RG 915 policy. And We also found that it is relative to the diopter of lenses. In conclusion, based on the researched that wearing finished reading glasses have a dangerous factor for our vision. Therefore optician must need to recommend correctly made dispensing reading glasses based on the optical center point.

  • PDF

Diagnostic Technique and Device for Railway Arresters (철도용 피뢰기 진단기술 및 장치)

  • Kil Gyung-Suk;Han Ju-Seop;Jang Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1422-1424
    • /
    • 2004
  • Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the phase vs. wave height of total leakage current is changed or a new wave height is produced with arrester ageing. To complete the new technique, we designed an arrester diagnostic device which is composed of a current detection circuit, an optical transmission circuit, and an analysis program. After measurement of the total leakage current, magnitudes, phase vs. wave height, and harmonics of the leakage current components are analyzed by the microprocessor based device. From the experimental results, we confirmed that the device can measure most parameters needed for the arrester diagnostics and analyze an initial deterioration state.

  • PDF

Analysis for PSA Tolerance of TAMR Suspension (열 보조 자기기록용 서스펜션의 PSA 허용오차에 대한 분석)

  • Kim, Ki-Hoon;Lee, Yong-Hyun;Kim, Seok-Hwan;Lee, Sang-Jic;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Su
    • Transactions of the Society of Information Storage Systems
    • /
    • v.6 no.1
    • /
    • pp.12-17
    • /
    • 2010
  • Thermally-assisted magnetic recording (TAMR) is a potentially promising approach to increase the storage density of hard disk drive (HDD). However, TAMR has some issues such as temperature effects, media problems, thermal deformation and light delivery. In this research, we focused on light delivery. One of the powerful methods to deliver the light from laser diode to recording medium is the use of an optical fiber and a specially designed prism. However, the TAMR with optical fiber may have some flyability problems induced by the mounted optical fiber and prism. Also, the TAMR suspension using an optical fiber has high vertical and pitch stiffness. Therefore, p-torque is greatly increased by the optical fiber. Also, flying height (FH) of the slider with TAMR suspension can be largely changed by p-torque. Therefore, in this paper, we focus on the pitch static attitude (PSA) tolerance and the FH by PSA of the TAMR suspension. The FH is investigated using various errors and the PSA tolerance for TAMR suspension is proposed.

Aerosol Direct Radiative Forcing by Three Dimensional Observations from Passive- and Active- Satellite Sensors (수동형-능동형 위성센서 관측자료를 이용한 대기 에어러솔의 3차원 분포 및 복사강제 효과 산정)

  • Lee, Kwon-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.2
    • /
    • pp.159-171
    • /
    • 2012
  • Aerosol direct radiative forcing (ADRF) retrieval method was developed by combining data from passive and active satellite sensors. Aerosol optical thickness (AOT) retrieved form the Moderate Resolution Imaging Spectroradiometer (MODIS) as a passive visible sensor and aerosol vertical profile from to the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) as an active laser sensor were investigated an application possibility. Especially, space-born Light Detection and Ranging (Lidar) observation provides a specific knowledge of the optical properties of atmospheric aerosols with spatial, temporal, vertical, and spectral resolutions. On the basis of extensive radiative transfer modeling, it is demonstrated that the use of the aerosol vertical profiles is sensitive to the estimation of ADRF. Throughout the investigation of relationship between aerosol height and ADRF, mean change rates of ADRF per increasing of 1 km aerosol height are smaller at surface than top-of-atmosphere (TOA). As a case study, satellite data for the Asian dust day of March 31, 2007 were used to estimate ADRF. Resulting ADRF values were compared with those retrieved independently from MODIS only data. The absolute difference values are 1.27% at surface level and 4.73% at top of atmosphere (TOA).

Optimization of Electrical/Optical Properties of ITO/Al Based Reflector for Vertical-type UV LEDs via SF6 Plasma Treatments (불소계열 플라즈마 처리를 통한 수직형 UV LED용 ITO/Al 기반 반사전극의 전기적/광학적 특성 최적화)

  • Shin, Ki-Seob;Kim, Dong-Yoon;Kim, Tae-Geun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.11
    • /
    • pp.911-914
    • /
    • 2011
  • We optimize electrical and optical properties of thermal and SF6 plasma treated indium tin oxide (ITO)/Al based reflector for high-power ultraviolet (UV) light-emitting diodes (LEDs). After thermal and $SF_6$ plasma treatments of ITO/Al reflector, the specific contact resistance decreased from $1.04{\times}10^{-3}\;{\Omega}{\cdot}cm^2$ to $9.21{\times}10^{-4}\;{\Omega}{\cdot}cm^2$, while the reflectance increased from 58% to 70% at the 365 nm wavelength. The low resistance and high reflectance of ITO/Al reflector are attributed to the reduced Schottky barrier height (SBH) between the ITO and AlGaN by large electronegativity of fluorine species and reduced interface roughness between the ITO and Al, respectively.

Height Measurement by Refractive Index Difference and Digital Holography (굴절률 차이와 디지털 홀로그래피를 이용한 큰 단차측정)

  • Cho, Hyung-Jun;Kim, Doo-Cheol;Yu, Young-Hun;Shin, Sang-Hoon;Lee, Hyuk-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.2
    • /
    • pp.81-86
    • /
    • 2009
  • Digital holography and refractive index difference are used to measure a high aspect ratio's patterns. When interference fringes are very closely spaced, the phase data containing high frequencies where $2{\pi}$ ambiguities cannot be resolved. In this technique, the optical path difference is decreased by decreasing the refractive index difference. As a result, we solve the $2{pi}$ ambiguities. Also, this technique is applicable to measure the refractive index if the shape of the sample is known.

The Study of Addressing Time and Electrical and Optical Characteristics as Phosphor Thickness and Height of discharge Space in ac-PDP (형광체 두께와 방전공간의 변화에 따른 ac PDP의 어드레싱 속도와 전기광학적 특성에 관한 연구)

  • Heo, Jeong-Eun;Kim, Gyu-Seup;Park, Jung-Hoo;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1815-1817
    • /
    • 2000
  • Plasma display Panels(PDPs) are one of the leading technologies currently under development for large-area high-brightness flat panel displays. However, the luminance and luminous efficiency of at PDPs should be improved. Especially, one of the main factors affecting on the luminance and luminous efficiency of ac PDP may be the phosphor thickness and size of discharge space. In this study, we examined into addressing time, electrical and optical properties as a parameter of the phosphor thickness and the size of discharge space during the display period of ac PDP. It is found out that the optimum phosphor thickness was $50{\mu}m$ and height of discharge space was about $100{\mu}m$.

  • PDF