• 제목/요약/키워드: Optical Fiber Sensors

검색결과 372건 처리시간 0.037초

Cyclic olefin copolymer (COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명 (SPR) 바이오 센서 (A fiber optic surface plasmon resonance (SPR) sensorusing cyclic olefin copolymer (COC) polymer prism)

  • 윤성식;이수현;안종혁;이종현
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.369-374
    • /
    • 2008
  • A novel fiber optic surface plasmon resonance (SPR) sensor using cyclic olefin copolymer (COC) prism with the spectral modulation is presented. The SPR sensor chip is fabricated using the SU-8 photolithography, Ni-electroplating and COC injection molding process. The sidewall of the COC prism is partially deposited with Au/Cr (45/2.nm thickness) by e-beam evaporator, and the thermal bonding process is conducted for micro fluidic channels and optical fibers alignment. The SPR spectrum for a phosphate buffered saline (0.1.M PBS, pH.7.2) solution shows a distinctive dip at 1300.nm wavelength, which shifts toward longer wavelength with respect to the bovine serum albumin (BSA)concentrations. The sensitivity of the wavelength shift is $1.16\;nm{\cdot}{\mu}g^{-1}{\cdot}{\mu}l^{-1}$. From the wavelength of SPR dips, the refractive indices (RI) of the BSA solutions can be theoretically calculated using Kretchmann configuration, and the change rate of the RI was found to be $2.3{\times}10^{-5}RI{\cdot}{\mu}g^{-1}{\cdot}l^{-1}$. The realized fiber optic SPR sensor with a COC prism has clearly shown the feasibility of a new disposable, low cost and miniaturized SPR biosensor for biochemical molecular analyses.

광학적 신호감지의 유전박막 다이아프레임을 이용하는 압력센서 (Thin dielectric diaphragm pressure sensor with optical readout)

  • 김명규;유양욱;박동수;김진섭;이정희;손병기
    • 센서학회지
    • /
    • 제5권4호
    • /
    • pp.1-7
    • /
    • 1996
  • 실리콘 미세가공 기술로 약 $0.6{\mu}m$ 두께의 150 nm-$Si_{3}N_{4}$/300 nm-$SiO_{2}$/150 nm-$Si_{3}N_{4}$ 다이아프레임을 실리콘 기판위에 형성하고, 이것과 광섬유를 결합하여 광강도형 압력센서를 제작하였다. 센서의 광원에서 사용하는 파장인 $1.3\;{\mu}m$ 근방에서 다이아프레임의 광투과도는 약 50 %였으나, 다이아프레임에 약 $1,000\;{\AA}$의 금(Au)을 증착하여 다이아프레임의 광투과도를 수 %정도로 감소시킬 수 있어서 이 다이아프레임을 센서의 광반사막으로 사용할 수 있었다. 다이아프레임의 크기를 $3{\times}3\;mm^{2}$, $4{\times}4\;mm^{2}$$5{\times}5\;mm^{2}$로 각각 변화시켜 제작한 센서에서, 센서의 광출력은 $0{\sim}77\;torr$의 측정압력범위에서 인가하는 압력을 중가 시킴에 따라 각각 선형적으로 감소하였으며, 이들 센서의 압력감도는 각각 0.52 nW/torr, 0.65 nW/torr 및 0.77 nW/torr로서 다이아프레임의 크기를 증가시킴에 따라 증가하였다.

  • PDF

광섬유 센서를 이용한 온도 및 변형 모니터링에 대한 현장응용 사례 (Case Studies on Distributed Temperature and Strain Sensing(DTSS) by using an Optical fiber)

  • 김중열;김유성;이성욱;민경주;박동수;방기성;김강식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.86-95
    • /
    • 2006
  • Brillouin backscatter is a type of reflection that occurs when light is shone into an optical fibre. Brillouin reflections are very sensitive to changes in the fibre arising from external effects, such as temperature, strain and pressure. We report here several case studies on the measurement of strain using Brillouin reflections. A mechanical bending test of an I beam, deployed with both fiber optic sensors and conventional strain gauge rosettes, was performed with the aim of evaluating: (1) the capability and technical limit of the DTSS technology for strain profile sensing; (2) the reliability of strain measurement using fiber optic sensor. The average values of strains obtained from both DTSS and strain gauges (corresponding to the deflection of I beam) showed a linear relationship and an excellent one-to-one match. A practical application of DTSS technology as an early warning system for land sliding or subsidence was examined through a field test at a hillside. Extremely strong, lightweight, rugged, survivable tight-buffered cables, designed for optimal strain transfer to the fibre, were used and clamped on the subsurface at a depth of about 50cm. It was proved that DTSS measurements could detect the exact position and the progress of strain changes induced by land sliding and subsidence. We also carried out the first ever distributed dynamic strain measurement (10Hz) on the Korean Train eXpress(KTX) railway track in Daejeon, Korea. The aim was to analyse the integrity of a section of track that had recently been repaired. The Sensornet DTSS was used to monitor this 85m section of track while a KTX train passed over. In the repaired section the strain increases to levels of 90 microstrain, whereas in the section of regular track the strain is in the region of 30-50 microstrain. The results were excellent since they demonstrate that the DTSS is able to measure small, dynamic changes in strain in rails during normal operating conditions. The current 10km range of the DTSS creates a potential to monitor the integrity of large lengths of track, and especially higher risk sections such as bridges, repaired track and areas at risk of subsidence.

  • PDF

광섬유 센서를 이용한 복합재의 파손 및 번형률 동시 측정 (Simultaneous Sensing of Failure and Strain in Composites Using Optical Fiber Sensors)

  • 방형준;강현규;홍창선;김천곤
    • Composites Research
    • /
    • 제14권5호
    • /
    • pp.12-19
    • /
    • 2001
  • 급격한 과도하중이나 충격 등에 의해서 발생만 복합적층 내부의 손상은 항공기 구조물과 같이 안전성이 중요시되는 구조의 신뢰성을 저하시키며 또한 큰 위험 요인이 될 수 있다. 따라서 본 연구에서는 구조의 건전성을 모니터링하고 파손여부를 실시간으로 감지하기 위해 단파장 레이저와 광대역광원을 동시에 적용한 광섬유 센서를 이용하여 변형률 및 파손을 실시간으로 동시에 모니터링 할 수 있는 시스템을 구성하였다 이때 서로 다른 파장대의 두 장원은 파장분할다중 송신기를 이용하여 하나의 광섬유 센서에 적용되었다 파손신호의 특징을 정량적으로 구분하기 위해 STFT와 Wavelet Transform 과 같은 시간 주파수 분석법을 사용하였으며, 광섬유 센서로 취득 긴 파손신호 및 변형률 측정값을 각각 압전 세라믹 센서와 스트레인게이지의 값과 서로로 비교하였다. 장시간동안 파손과 동시에 측정된 변형률의 값은 스트레인게이지의 측정값과 잘 일치하였으며 파손감지 시스템 또만 미세한 파손신호까지 민감하게 감지해 낼 수 있음을 알 수 있었다.

  • PDF

Fiber Bragg Grating 센서를 이용한 저진동 가속도계 개발 (Development of a Low Frequency Accelerometer using the Fiber Bragg Grating Sensor)

  • 백인석;강한빈;이계광;이석순
    • 한국정밀공학회지
    • /
    • 제29권10호
    • /
    • pp.1101-1109
    • /
    • 2012
  • Accelerometers play a key role in the structural assessment. However, the current electric type accelerometers have certain limitations to apply some structures such as heavy cabling labor, installed sea structure and sensitivity to electromagnetic fields. An optical Fiber Bragg Grating (FBG) accelerometer has many advantages over conventional electrical sensors since their immunity to electromagnetic interference and their capability to transmit signals over long distance without any additional amplifiers, and there is no corrosion from sea water. In this paper, we have developed a new FBG-based accelerometer. The accelerometer consists of two cantilevered type beams and a mass and two rollers. A bragg grating element is not directly glued to a cantilever to avoid possible non-uniform strain in the element. Instead, the bragg grating element will be attached to rotation part that rolled inducing vertical movement of the mass and support cantilever beams so that the bragg grating element is uniformly tensioned to achieve a constant strain distribution. After manufacturing, we will prove the performance and the natural frequency of the accelerometer through the experiment with a vibration shaker. The FBG-based accelerometer is developed for measuring the vibration not exceeding 50 Hz for the marine and civil structures.

광섬유센서를 이용한 레저선박의 선체구조모니터링시스템 개발에 관한 연구(I) (A Study on the Development of leisure boat's Hull Stress Monitoring System using AWG)

  • 강남선;김헌우
    • 해양환경안전학회지
    • /
    • 제17권3호
    • /
    • pp.269-274
    • /
    • 2011
  • 주5일제 정착, 소득의 향상, 연안지역 접근성 개선으로 해양관광 활동에 대한 관심과 해양레저 활동에 대한 수요가 증가하고 있으나, 해양활동을 위한 인프라구축 및 레저선박과 인명의 안전을 위한 시스템개발은 미비한 실정이다. 일반선박과 달리 레저선박은 구조안전성 평가 시스템을 위한 규정 및 적용 기준이 명확히 정립되어 있지 않으며, 시스템 개발이 전무하여 레저보트의 운항안전성 확보를 위한 레저보트 구조 안전모니터링시스템의 개발이 필요하다. 따라서 본 연구에서는 도파로 어레이 격자(AWG, Arrayed waveguide grating)와 광섬유 브래그 격자 센서(FBG)를 이용하여 레저보트의 실시간 선체구조모니터링이 가능한 시스템을 개발하여 해상에서의 인명과 레저선박의 안전성을 확보하고자 한다.

유전체 박막을 이용한 다이아프램형 광섬유 Fabry-Perot 간섭계 압력센서의 특성 (Characteristics of A Diaphragm-Type Fiber Optic Fabry-Perot Interferometric Pressure Sensor Using A Dielectric Film)

  • 김명규;유양욱;권대혁;이정희;김진섭;박재희;채용웅;손병기
    • 센서학회지
    • /
    • 제7권3호
    • /
    • pp.147-153
    • /
    • 1998
  • $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$(N/O/N) 다이아프램과 결합된 고감도의 광섬유 Fabry-Peort 압력센서를 개발하여 스트레인 및 그 응답특성을 조사하였다. 먼저, 44 wt% KOH 수용액을 이용한 실리콘 이방성식각기술로 600 nm 두께의 N/O/N 다이아프램을 제조하였으며, 제조된 다이아프램과 광섬유 Fabry-Perot 간섭계를 결합하여 광섬유 압력센서를 구성하였다. 단일모드 광섬유(SMF)내에 $TiO_{2}$ 유전체 박막을 용융접합하여 공극의 길이가 약 2 cm인 광섬유 Fabry-Perot 간섭계를 제작하였다. 광섬유 Fabry-Perot 간섭계의 한쪽 끝은 N/O/N 다이아프램과 결합하였으며, 나머지 한쪽을 3 dB 광결합기를 통해 광측정장치에 연결하였다. $2{\times}2\;mm^{2}$$8{\times}8\;mm^{2}$ 크기의 N/O/N 다이아프램에 대해 응답특성을 조사한 결과, 각각 약 0.11 rad/kPa과 1.57 rad/kPa의 압력감도를 나타내었으며, 선형오차는 0.2 %FS이내였다.

  • PDF

사분파장 위상 간섭계 폴리머 광집적회로 기반 광전류센서의 온도 안정성 향상 연구 (Improvement of Thermal Stability of Optical Current Sensors Based on Polymeric Optical Integrated Circuits for Quadrature Phase Interferometry)

  • 천권욱;김성문;박태현;이은수;오민철
    • 한국광학회지
    • /
    • 제30권6호
    • /
    • pp.249-254
    • /
    • 2019
  • 광섬유가 지니는 패러데이 효과를 이용하여 전류의 세기를 측정하는 광전류 센서 소자를 설계 및 제작하였다. 센서 소자의 동작 안정성을 향상시키기 위하여 편광회전 반사 간섭계와 사분 파장 위상 간섭계 구조를 도입하였다. 이 복잡한 구조를 구성하는 다양한 광소자들은 하나의 폴리머 광집적회로로 구성하여 작은 크기로 제작되었다. 본 구조를 이용하면 외부에서 별도의 바이어스 피드백 제어가 필요 없는 상태에서 전류를 측정하는 센싱 동작을 수행할 수 있다. 또한 온도변화나 외부진동으로 인한 광센서 특성 변화를 제거하여 안정적인 특성을 유지하는 광전류센서를 구현할 수 있다. 그러나 패러데이 효과를 결정짓는 베르데상수는 온도에 따라 미소한 값의 변화를 가지고 있다. 본 연구에서는 이 변화로 인한 광전류센서의 온도의존성을 극복하기 위한 연구를 수행하였다. 편광회전 반사 간섭계의 부품인 광섬유 사분 파장판의 길이를 최적값으로부터 벗어나는 상태로 맞추어 줌으로써 베르데 상수의 온도의존성에 의해 나타나는 광전류센서의 스케일 팩터 변화를 보상해줄 수 있었다. 온도변화를 보상한 광전류센서는 주변 온도를 상온에서 85℃로 올리는 동안, 센서 측정 신호의 온도 의존성이 0.2% 이내로 유지되는 것을 확인했다.

온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구 (A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring)

  • 김중열;송윤호;김유성
    • 한국지반공학회논문집
    • /
    • 제23권4호
    • /
    • pp.15-24
    • /
    • 2007
  • 본 연구에서는 여러 지점의 온도를 동시에 측정할 수 있는 두 가지 온도 모니터링 기법을 소개하고 있다. 그 하나는 고유주소를 가지고 있는 온도센서로 구성된 온도센서 배열 케이블을 이용하는 기법이며, 다른 하나는 광섬유 센서를 이용하여 분포 온도를 측정하는 기법이다. 이 두 기법의 차이점은 다음과 같이 요약될 수 있다. 온도센서 배열 케이블은 온도센서가 위치하는 정확한 지점의 온도를 측정하게 된다. 그에 대한 온도 측정의 정밀도 및 분해능은 그 온도 센서의 성능에 따라 결정된다. 한편, 광섬유 센서는 레이저 펄스가 광섬유를 따라 보내질 때 생성되는 Raman 역산란파를 분석함으로써 온도를 측정하기 때문에 분포 개념의 온도를 측정하게 된다. 그에 대한 온도 분해능은 측정거리, 측정시간 및 온도측정 거리분해능에 따라 결정된다. 본 논문은 두 가지 온도 모니터링 시스템의 장단점을 비교함으로써 기술적이고 경제적인 측면에서 그의 응용분야를 면밀히 검토하는 데 그 목적이 있다. 이를 위해 두 기법을 이용한 다양한 실험을 실시하였다. 그 결과를 검토해 보면 온도센서 배열 케이블은 300m 범위 내의 지하수 흐름, 지열 분포 및 그라우팅 효과 검증에 적합할 것으로 판단되며 광섬유 센서는 상대적으로 긴 거리에 걸친 분포 온도에 대한 정보가 필요한 파이프 파인 감시, 터널 화재 감시 및 전력선 모니터링과 같은 분야에서 효율적으로 활용될 것이 기대된다.

Detecting of Periodic Fasciculations of Avian Muscles Using Magnetic and Other Multimedia Devices

  • Nakajima, Isao;Tanaka, Sachie;Mitsuhashi, Kokuryo;Hata, Jun-ichi;Nakajima, Tomo
    • Journal of Multimedia Information System
    • /
    • 제6권4호
    • /
    • pp.293-302
    • /
    • 2019
  • In the past, there was a theory that influenza wasn't transmitted directly from birds but was infected to humans via swains. Recently, molecular level research has progressed, and it was confirmed that the avian influenza virus can directly infected to human lung and intestinal epithelial cells. Three pandemicsin the past 100 years were also infected to humans directly from birds. In view of such scientific background, we are developing a method for screening sick birds by monitoring the physiological characteristics of birds in a contactless manner with sensors. Here, the movement of respiratory muscles and abdominal muscles under autonomic innervation was monitored using a magnet and Hall sensor sewn on the thoracic wall, and other multimedia devices. This paper presents and discusses the results of experiments involving continuous periodic noise discovered during flight experiments with a data logger mounted on a Japanese pheasant from 2012 to 2015. A brief summary is given as the below: 1. Magnet and Hall sensor sewn to the left and right chest walls, bipolar electrocardiograms between the thoracic walls, posterior thoracic air sac pressure, angular velocity sensors sewn on the back and hips, and optical reflection of LEDs (blue and green) from the skin of the hips allow observation of periodic vibrations(fasciculations) in the waves. No such analysis has been reported before. 2. These fasciculations are presumed to be derived from muscle to maintain and control air sac pressure. 3. Since each muscle fiber is spatially Gaussian distributed from the sympathetic nerve, the envelope is assumed to plot a Gaussian curve. 4. Since avian trunk muscles contract periodically at all time, we assume that the sympathetic nerve dominates in their control. 5. The technique of sewing a magnet to the thoracic wall and measuring the strength of the magnetic field with a Hall sensor can be applied to screen for early stage of avian influenza, with a sensor attached to the chicken enclosure.