• Title/Summary/Keyword: Optical Bio-Sensor

Search Result 48, Processing Time 0.023 seconds

Optical Characteristics of Bolometric Terahertz Sensor (볼로미터형 테라헤르츠 센서의 광학적 특성 연구)

  • Han, Myung Soo;Song, Woosub;Hong, Jung Taek;Lee, Donghee
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.335-339
    • /
    • 2018
  • The optical characteristics of a terahertz (THz) antenna-coupled bolometer (ACB) detector were evaluated using a pulsed quantum cascade laser (QCL) and radiation blackbody sources. We investigated a method for measuring the responsivity and noise-equivalent power (NEP) of the THz detector using two different types of light sources. When using a QCL source with a frequency of 3 THz, the average responsivity of 24 devices was $1.44{\times}10^3V/W$ and the average NEP of those devices was $3.33{\times}10^{-9}W/{\surd}Hz$. The average responsivity and NEP as measured by blackbody source were $1.79{\times}10^5V/W$ and $6.51{\times}10^{-11}W/{\surd}Hz$, respectively, with the measured values varying depending on the light source. This was because the output power of each light source was different, with the laser source being driven by a pulse type wave and the blackbody source being driven by a continuous wave. The power input to the THz sensor was also different. Futhermore, the responsivity and NEP values measured using band pass filter (BPF) were similar to those measured when using only THz windows. It was found that ACB sensor responds normally in the THz region to both the laser and the blackbody source, and the method was confirmed to effectively evaluate the characteristics of the THz sensor.

Design of Bio-Inspired Morpho Butterfly Structures for Optical Sensor Applications (광학 센서 응용을 위한 모르포 나비 날개 모방 구조 설계)

  • Kim, Hyeon Myeong;Lee, Gil Ju;Kim, Min Seok;Kim, Kyu Jung;Song, Young Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.5
    • /
    • pp.357-362
    • /
    • 2016
  • Various species of insects display vivid colors, widely known as 'structural color' due to their optical interference. Morpho butterflies are famous for their brilliant iridescent colors, which arise from the photonic-nanostructures of optical interference on their wings. In this paper, we outline the results of a comparative study of the optical properties of bio-inspired Morpho butterfly structures with the widely known Distributed Bragg Reflector (DBR), conducted using a rigorous coupled-wave analysis (RCWA) method for the two structures. Almost analogous tendencies were observed for both Morpho and DBR structures. With variation in the surrounding media, however, Morpho structures showed an obvious peak shift while no significant changes were observed in DBR, which can be applicable.

Discernibly Temperature-insensitive Pressure Sensitivity in Porous Random-Hole Optical Fibers

  • Kim, Jeong;Kominsky, Dan;Pickrell, Gary
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.300-304
    • /
    • 2013
  • Novel breakthrough random-hole optical fibers (RHOFs) are fabricated in a draw tower facility, by tapering an optical fiber preform packed with a silica powder mixture capable of producing air holes in situ at the high temperature of tens of hundreds in degrees Celsius. Structural and propagation characteristics of the porous RHOF are explained briefly. Experimental investigations of the invented RHOF are performed for pressure sensor applications. Remarkable results are obtained for the RHOF with desirable pressure sensitivity independent of temperature, as is required for harsh conditions as in oil reservoirs.

Imaging the Enzymatic Reaction of Urease Using Liquid Crystal-Based pH Sensor

  • Hu, Qiong-Zheng;Jang, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4377-4381
    • /
    • 2011
  • In this study, real-time and label-free methods for monitoring the enzymatic reaction of urease, which releases ammonia through the hydrolysis of urea in an aqueous solution, were developed using a liquid crystal (LC)-based pH sensor. Nematic liquid crystal 4-cyano-4'-pentylbiphenyl (5CB), doped with 4'-pentyl-biphenyl-4-carboxylic acid (PBA), exhibited a shift in optical appearance from bright to dark when it was in contact with ammonia generated from the enzymatic reaction between urease and urea. This optical change was attributed to the anchoring transitions of LCs caused by hydrophobic interactions between the tails of deprotonted PBA ($PBA^-$) molecules and the LCs at the aqueous/LC interface. This novel technique holds great promise for the sensitive detection of urease along with its substrates and inhibitors.

X-ray grayscale lithography for sub-micron lines with cross sectional hemisphere for Bio-MEMS application (엑스선 그레이 스케일 리소그래피를 활용한 반원형 단면의 서브 마이크로 선 패턴의 바이오멤스 플랫폼 응용)

  • Kim, Kanghyun;Kim, Jong Hyun;Nam, Hyoryung;Kim, Suhyeon;Lim, Geunbae
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.170-174
    • /
    • 2021
  • As the rising attention to the medical and healthcare issue, Bio-MEMS (Micro electro mechanical systems) platform such as bio sensor, cell culture system, and microfluidics device has been studied extensively. Bio-MEMS platform mostly has high resolution structure made by biocompatible material such as polydimethylsiloxane (PDMS). In addition, three dimension structure has been applied to the bio-MEMS. Lithography can be used to fabricate complex structure by multiple process, however, non-rectangular cross section can be implemented by introducing optical apparatus to lithography technic. X-ray lithography can be used even for sub-micron scale. Here in, we demonstrated lines with round shape cross section using the tilted gold absorber which was deposited on the oblique structure as the X-ray mask. This structure was used as a mold for PDMS. Molded PDMS was applied to the cell culture platform. Moreover, molded PDMS was bonded to flat PDMS to utilize to the sub-micro channel. This work has potential to the large area bio-MEMS.

Implementation of Novel Bio-sensor Platform based on Optical Taper Coupler (광 테이퍼 결합기에 기초한 새로운 바이오-센서 플랫폼의 구현)

  • Kwang-Chun Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.5
    • /
    • pp.145-150
    • /
    • 2023
  • Non-uniform optical taper waveguides have been widely used as devices for high-efficiency mode coupling, as they are integrated with single-mode optical fibers or photonic crystal waveguides. In this paper, we present a new platform for chemical sensing and bio-sensing using optical taper waveguides with these characteristics. The principle of operation is based on the coupling efficiency and interference properties of optical directional coupler (DC) and multi-mode interference coupler (MMIC). First, the curvature characteristics of taper sections of DC and MMIC is explained, and the design specifications of optimized taper waveguide to increase waveguide sensitivity is selected. Next, the sensor response to the change in refractive index of sensing analyte is numerically analyzed. Numerical results show that as the length of couplers increases, the effective index per change in refractive index unit (RIU) of analyte increases, and that sensitivity can be tuned using taper DC and MMIC design techniques.

A Study on Dip-Pen Nanolithograpby Process to Fabricate 2D Pbotonic Crystal for Planar-Type Optical Bio-Sensor (평판형 광-바이오센서 (Planar-Type Optical Bio-Sensor)용 2차원 광자결정 제작을 위한 Dip-Pen Nanolithography 공정 연구)

  • Kim, Jun-Hyong;Lee, Jong-Il;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.381-383
    • /
    • 2005
  • 바이오센서 응용을 위한 대칭 및 비대칭 마하젠더 간섭계 광도파로 소자의 설계, 제작 및 광학적 응답특성을 평가하였다. 설계 제작된 광도파로 소자의 압력광원은 각각 1550nm와 632.8nm이고, 코어와 클래딩의 굴절률차는 0.45 $\Delta$%로 설계 제작하였다. 센서부(상위 클래드)의 금 박막의 미소 굴절률 변화에 따른 TE, TM모드의 특성을 분석하였다. 센서의 보다 높은 감도 개선을 위한 나노-광자결정 구조가 주목받고 있는데, 광자결정 구조의 구현를 위한 리소그래피 공정은 높은 분해능과 신뢰성 있는 나노스케일의 공정이 요구된다. 광-바이오센서의 감도 개선을 위해 센서부 표면에 2차원 나노-광자결정 배열을 제안하고 이를 구현하기 위한 Dip-Pen Nanolithography 공정에 대해 고찰하였다.

  • PDF

Optical Characteristics of Plasmonic Nano-structure Using Polystyrene Nano-beads (폴리스티렌 나노 비드를 이용한 플라즈모닉 나노 구조체의 광학 특성)

  • Kim, Doo Gun;Jung, Byung Gue;Kim, Hong-Seung;Kim, Tae-Ryong;Kim, Seon-Hoon;Ki, Hyun-Chul;Kim, Tae-Un;Shin, Jae Cheol;Choi, Young-Wan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.4
    • /
    • pp.244-248
    • /
    • 2015
  • We proposed and demonstrated the double layered metallic nano-hole structure using polystyrene beads process to enhance the sensitivity of surface plasmon resonance (SPR). The double layered SPR structures are calculated using the finite-difference time-domain (FDTD) method for the width, thickness, and period of the metallic nano-hole structures. The thickness of the metal film and the metallic nano-hole is 30 and 20 nm in the 214 nm wide nano-hole size, respectively. The double layered SPR structures are fabricated with monolayer polystyrene beads of 420 nm wide. The sensitivities of the conventional SPR sensor and the double layered SPR sensor are obtained to 42.2 and 52.1 degree/RIU, respectively.

Implementation of Novel Bio-sensor Platform based on Optical MMI and Directional Coupler (광 MMI와 방향성 결합기에 기초한 새로운 바이오 센서 플랫폼의 구현)

  • Kwang-Chun Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.163-168
    • /
    • 2023
  • In this paper, a novel platform for chemical sensing and biosensing is presented. The working principle is based on the coupling efficiency and interference properties of optical directional coupler (DC) and multimode interference coupler (MMIC). It has been realized using planar technology to allow integration on a silicon substrate. Firstly, the dispersion curves of DC and MMIC is described, and the design specification of an optimized slot optical waveguide to increase waveguide sensitivity is selected. Next, the sensor response to the refractive index change of sensing analyte is numerically simulated. The numerical results reveal that high effective index change per refractive index unit (RIU) change of analyte is obtained, and the sensitivity can be tuned using the DC and MMIC design technique.

Polymer Waveguide Based Refractive Index Sensor Using Polarimetric Interference (편광 간섭을 이용한 광도파로 기반의 표면 굴절률 센서)

  • Son, Geun-Sik;Kwon, Soon-Woo;Kim, Woo-Kyung;Yang, Woo-Seok;Lee, Hyung-Man;Lee, Han-Young;Lee, Sung-Dong;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.193-198
    • /
    • 2008
  • A novel refractive index sensor, which consists of polymer channel waveguide overlaid with $TiO_2$ thin film, is demonstrated. To evaluate the fabricated sensor, we measured the polarimetric interference induced by concentration change of injected glycerol solution. Our experimental results show that thicker $TiO_2$ film improves the sensitivity of the polarimetric interferometer. For the fabricated waveguide with a 20 nm thick $TiO_2$ film, the measured index change to lead phase variation of $2{\pi}$ is $1.8{\times}10^{-3}$.