• 제목/요약/키워드: Optical Alignment System

검색결과 184건 처리시간 0.031초

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

A Study on the Measurement for the Nano Scale Film Formation of Ultra Low Aspect Ratio

  • Jang Siyoul;Kong Hyunsang
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.283-288
    • /
    • 2004
  • The measurement of ultra low aspect ratio fluid film thickness is very crucial technique both for the verification of lubrication media characteristics and for the clearance design in many precision components such as MEMS, precision bearings and other slideways. Many technologies are applied to the measurement of ultra low aspect ratio fluid film thickness (i.e. elastohydrodynamic lubrication film thickness). In particular, in-situ optical interferometric method has many advantages in making the actual contact behaviors realized with the experimental apparatus. This measurement method also does the monitoring of the surface defects and fractures happening during the contact behavior, which are delicately influenced by the surface conditions such as load, velocity, lubricant media as well as surface roughness. Careful selection of incident lights greatly enhances the fringe resolutions up to $\~1.0$ nanometer scale with digital image processing technology. In this work, it is found that coaxial aligning trichromatic incident light filtering system developed by the author can provide much finer resolution of ultra low aspect ratio fluid film thickness than monochromatic or dichromatic incident lights, because it has much more spectrums of color components to be discriminated according the variations of film thickness. For the measured interferometric images of ultra low aspect ratio fluid film thickness it is shown how the film thickness is finely digitalized and measured in nanometer scale with digital image processing technology and space layer method. The developed measurement system can make it possible to visualize the contact deformations and possible fractures of contacting surface under the repeated loading condition.

  • PDF

PMMA/P(MMA/MAA) 구조에서 0.1$\mu\textrm{M}$ T-gate 형성을 위한 전자빔 리소그래피 공정에 관한 연구 (A study on electron beam lithography for 0.1$\mu\textrm{M}$ T-gate formation at P(MMA/MAA)/PMMA structure)

  • 최상수;이진희;유형준;이상윤
    • 한국재료학회지
    • /
    • 제5권1호
    • /
    • pp.96-103
    • /
    • 1995
  • 30KV 전자빔리소그래피 장치를 사용하여 PMMA 3000$\AA$/P(MMA/MAA) 6000$\AA$의 이중구조에서 foot width 0.1$\mu$m이하, head width 0.4$\mu$m의 T-gate를 형성하였다. PMMA/P(MMA/MAA)/GaAS 구조에 대한 Monte Carlo 시뮬레이션 결과, 산란반경 0.1$\mu$m에서 전방산란전자와 후방산란전자의 에너지 비는 19.5:1로 나타났다. 전자빔리소그래피 공정에 필요한 PMMA 및 P(MMA/MMA)의 열처리 조건, 설게 선폭에 대한 패턴감도를 구하였다. MIBK : IPA = 1 : 1 현상액에 대한 PMMA 및 P(MMA/MAA)의 감마값(gamma value)은 2.3이었다. 광 및 전자빔리소그래피 장치의 혼합사용(mix-and-match) 결과 층간정렬도 (alignment accuracy)는 0.1$\mu$m(3$\sigma$) 이하를 얻었다.

  • PDF

주파수 위상 부호화와 위상 랩핑 방법을 이용한 영상 암호화 및 복호화 시스템 (Image Encryption and Decryption System using Frequency Phase Encoding and Phase Wrapping Method)

  • 서동환;신창목;조규보
    • 한국광학회지
    • /
    • 제17권6호
    • /
    • pp.507-513
    • /
    • 2006
  • 본 논문에서는 출력평면에 나타나는 원 영상을 재생시키기 위하여 위상 랩핑 방법을 이용하여 암호화 수준을 향상시키고 주파수 영역에서 위상 부호화하여 암호화함으로써 잡음에 강한 복호화 방법을 제안하였다. 암호화된 영상은 원 영상이 아닌 위상 변조된 가상 영상과 무작위 위상 영상을 곱하고 제로 패딩(ze.o-padding)하여 푸리에 변환한 후 이 변환된 복소 영상을 데이터 전송 및 매핑을 용이하게 하기 위하여 실수 값으로 변환하여 위상 부호화하여 만든다. 복호화 과정은 제안한 선형적인 영상을 비선형적인 영상으로 변환시키는 위상 랩핑 방법에 의해 각각 만들어진 암호화된 영상과 복호화 키를 곱하여 푸리에 역변환하여 공간필터를 가진 출력 평면에서 원 영상을 복원함으로써 광축 정렬 문제와 픽셀 대 픽셀 대응이 용이하여 복원영상의 해상도를 향상시킬 수 있다. 제안한 방법은 허가되지 않은 사용자가 암호화된 영상을 분석함으로써 있을 수 있는 복제 가능성을 원 영상의 어떤 정보도 포함하지 않은 가상 영상을 사용함으로써 배제할 수 있고 또한 실수 값을 위상 부호화함으로써 현재에 사용되는 공간 광 변조기로 표현이 가능하다. 컴퓨터 모의 실험을 통하여 제안한 암호화 방법의 적합성과 암호화된 영상과 복호화 키 영상에 잡음이 발생하더라도 원 영상의 복원이 가능함을 확인하였다.

Pt 촉매 박막을 이용한 비정질 SiOx 나노기둥의 수직성장 (Vertical Growth of Amorphous SiOx Nano-Pillars by Pt Catalyst Films)

  • 이지언;김기출
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.699-704
    • /
    • 2018
  • 일차원 나노구조물은 양자 갇힘 효과 및 나노와이어가 갖는 체적 대비 높은 표면적 비에 기인하는 독특한 전기적, 광학적, 광전기적, 전기화학적 특성으로 인하여 많은 주목을 받아왔다. 특히 수직으로 성장된 나노와이어는 체적 대비 높은 표면적 비의 특성을 나타낸다. VLS(Vapor-Liquid-Soild) 공정은 나노구조물의 성장 과정에서 자기정렬 효과 때문에 더욱 주목을 받는다. 본 연구에서는 두 영역 열화학 기상증착법을 이용하여 Si\$SiO_2$(300 nm)\Pt 기판 위에 수직으로 정렬된 실리콘 옥사이드 나노기둥을 VLS 공정으로 성장시켰다. 성장된 실리콘 옥사이드 나노기둥의 형상과 결정학적 특성을 주사전자현미경 및 투과전자현미경으로 분석하였다. 그 결과 성장된 실리콘 옥사이드 나노기둥의 지름과 길이는 촉매 박막의 두께에 따라 변하였다. 실리콘 옥사이드 나노 기둥의 몸체는 비정질 상을 나타내었으며, Si과 O로 구성되어 있었다. 또한 성장된 실리콘 옥사이드 나노 기둥의 머리는 결정성을 나타내었으며, Si, O, Pt 및 Ti으로 구성되어 있었다. 실리콘 옥사이드 나노 기둥의 수직 정렬은 촉매물질인 Pt/Ti 합금의 결정성 정렬 선호에 기인하는 것으로 판단되며, 수직 성장된 실리콘 옥사이드 나노기둥은 기능성 나노소재로 활용이 가능할 것으로 기대된다.

Radiometric performance characterization for breadboard AMON-RA energy channel instrument for deep space albedo measurement

  • Jung, Kil-Jae;Ryu, Dong-Ok;Ahn, Ki-Beom;Oh, Eun-Song;Lee, Jae-Min;Kim, Yun-Jong;Yu, Jin-Hee;Yi, Hyun-Su;Ham, Sun-Jung;Yoon, Ji-Yeon;Yoon, Ho-Seop;Hong, Jin-Seok;Yang, Ho-Soon;Chon, Byong-Hyok;Hwang, Hae-Sook;Lee, Han-Shin;Kim, Sug-Whan;Lockwood, Mike
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.35.2-35.2
    • /
    • 2008
  • The Albedo MONitor and RAdiometer (AMON-RA) instrument system is designed to measure Earth global albedo anomaly over the wavelength range of 0.3um to 4um. The instrument consists of two interconnecting optical subsystems i.e. a visible channel and an energy channel. The energy channel instrument consists of a modified Winston cone, a couple of relay mirrors and a pyro-electric detector. First, we report the integration and alignment process, leading to the prototype bolometer instrument. We then discuss the radiometric performance characterization including laboratory measurement results and the future plan for further incorporation of the bolometer instrument into the prototype AMON-RA instrument.

  • PDF

The Performance of Flight Model of the NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Moon, Bongkon;Park, Sung-Joon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Won-Kee;Kim, Il-Joong;Park, Youngsik;Ko, Kyeongyeon;Kim, Mingyu;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.58.1-58.1
    • /
    • 2017
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) is the near-infrared spectro-photometric instrument optimized to the first Next Generation of small satellite (NEXTSat-1). The off-axis optics was developed to cover a wide field of view with 2 deg. ${\times}$ 2 deg. as well as a wide wavelength range from 0.95 to $2.5{\mu}m$. Considering the simple alignment scheme, afocal system was adapted in the optical components. The mechanical structures were tested under the space environment. We have obtained the accurate calibration data using our test facilities under the operational condition. After the final integration of flight model into the satellite, the communication with the satellite and the functional test were passed. The NISS will be launched in early 2018. During around 2-year operation, the spectro-photometric survey covering more than 100 square degree will be performed. To achieve the major scientific objectives for the study of the cosmic star formation in local and distant universe, the main observational targets will be nearby galaxies, galaxy clusters, star-forming regions and low background regions. Here, we report the final performance of the flight model of the NISS.

  • PDF

Cyclic olefin copolymer (COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명 (SPR) 바이오 센서 (A fiber optic surface plasmon resonance (SPR) sensorusing cyclic olefin copolymer (COC) polymer prism)

  • 윤성식;이수현;안종혁;이종현
    • 센서학회지
    • /
    • 제17권5호
    • /
    • pp.369-374
    • /
    • 2008
  • A novel fiber optic surface plasmon resonance (SPR) sensor using cyclic olefin copolymer (COC) prism with the spectral modulation is presented. The SPR sensor chip is fabricated using the SU-8 photolithography, Ni-electroplating and COC injection molding process. The sidewall of the COC prism is partially deposited with Au/Cr (45/2.nm thickness) by e-beam evaporator, and the thermal bonding process is conducted for micro fluidic channels and optical fibers alignment. The SPR spectrum for a phosphate buffered saline (0.1.M PBS, pH.7.2) solution shows a distinctive dip at 1300.nm wavelength, which shifts toward longer wavelength with respect to the bovine serum albumin (BSA)concentrations. The sensitivity of the wavelength shift is $1.16\;nm{\cdot}{\mu}g^{-1}{\cdot}{\mu}l^{-1}$. From the wavelength of SPR dips, the refractive indices (RI) of the BSA solutions can be theoretically calculated using Kretchmann configuration, and the change rate of the RI was found to be $2.3{\times}10^{-5}RI{\cdot}{\mu}g^{-1}{\cdot}l^{-1}$. The realized fiber optic SPR sensor with a COC prism has clearly shown the feasibility of a new disposable, low cost and miniaturized SPR biosensor for biochemical molecular analyses.

조직투명화 기술을 통한 3차원적 접근 (Three-Dimensional Approaches in Histopathological Tissue Clearing System)

  • 이태복;이재왕;전진현
    • 대한임상검사과학회지
    • /
    • 제52권1호
    • /
    • pp.1-17
    • /
    • 2020
  • 조직병리학에서 현미경을 이용한 삼차원적 접근법은, 이차원 단면의 조직 슬라이드에서 박절 과정 중 부차적으로 발생하는 공간정보의 손실로 인하여 확인하기 어려웠던, 조직 내부 분자들의 공간적 배열, 상호결합, 구조적인 형태와 이들의 통합적인 공간적 정보체로서, 조직 내에 복잡하게 얽혀진 다양한 정보를 풀어내는데 있어서 복합적인 데이터를 제시하여 준다. 이광자 현미경(two-photon microscope)과 자동화된 보정환(correction collar)이 탑재된 고성능 대물렌즈의 개발과 같은 광학장비 영역의 발전은 조직투명화 과정을 거치지 않은 두꺼운 시료의 이미징에 있어서 광학적인 이론과 실체 사이에 존재하는 격차를 줄이는데 기여하였다고 할 수 있다. 하지만, 대물렌즈의 길어진 작동범위(working distance)와 최적화된 고강도 레이저의 사용으로 얻게 되는 이점들은 세포 내 각 구성요소의 굴절률(refractive index) 차이로 인하여 증가되는 빛의 분산(light scattering) 현상으로 인해 자연스럽게 감소하게 된다. 조직투명화 기술이 처음 등장하였던 초창기 시도되던 간단한 굴절률 일치화(RI matching) 기법에서부터 현대의 최첨단 통합 조직 투명화 기술에 이르기 까지를 관찰하여 볼 때, 형태학적인 변화없이 조직의 투명도를 높이는 것과, 내재적으로 또는 고정과정 중에 유래되어 혼합된 자가형광 노이즈를 효과적으로 제거하는것이 선명한 이미지를 얻기 위한 주요한 고려대상이라고 할 수 있다. CLARITY는 장비에 기반한 조직투명화 기법으로서 임상 조직병리 실험실에서 처리되는 동결절편과 포르말린에 고정된 검체 모두의 투명화를 위한 실험실 작업흐름(workflow) 통합 및 일상적인 실험절차와 호환이 가능할 것으로 보여진다.

IGRINS Design and Performance Report

  • Park, Chan;Jaffe, Daniel T.;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Yu, Young Sam;Kaplan, Kyle;Mace, Gregory;Kim, Hwihyun;Lee, Jae-Joon;Hwang, Narae;Kang, Wonseok;Park, Byeong-Gon
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.90-90
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is the first astronomical spectrograph that uses a silicon immersion grating as its dispersive element. IGRINS fully covers the H and K band atmospheric transmission windows in a single exposure. It is a compact high-resolution cross-dispersion spectrometer whose resolving power R is 40,000. An individual volume phase holographic grating serves as a secondary dispersing element for each of the H and K spectrograph arms. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{{\prime}{\prime}}{\times}15^{{\prime}{\prime}}$. IGRINS has a plate scale of 0.27" pixel-1 on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with a SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized ($0.96m{\times}0.6m{\times}0.38m$) rectangular Dewar. The fabrication and assembly of the optical and mechanical components were completed in 2013. From January to July of this year, we completed the system optical alignment and carried out commissioning observations on three runs to improve the efficiency of the instrument software and hardware. We describe the major design characteristics of the instrument including the system requirements and the technical strategy to meet them. We also present the instrumental performance test results derived from the commissioning runs at the McDonald Observatory.

  • PDF