• Title/Summary/Keyword: Optic system

Search Result 786, Processing Time 0.034 seconds

Compensation of the Straightness Measurement Error in the Laser Interferometer (레이저 간섭계의 진직도 측정오차 보상)

  • Khim Gyungho;Keem Tae-Ho;Lee Husang;Kim Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.9 s.174
    • /
    • pp.69-76
    • /
    • 2005
  • The laser interferometer system such as HP5529A is one of the most powerful equipment fur measurement of the straightness error in precision stages. The straightness measurement system, HP5529A is composed of a Wollaston prism and a reflector. In this system, the straightness error is defined as relative lateral motion change between the prism and the reflector and computed from optical path difference of two polarized laser beams between these optics. However, rotating motion of the prism or the reflector used as a moving optic causes unwanted straightness error. In this paper, a compensation method is proposed for removing the unwanted straightness error generated by rotating the moving optic and an experiment is carried out for theoretical verification. The result shows that the unwanted straightness error becomes very large when the reflector is used as the moving optic and the distance between the reflector and the prism is far. Therefore, the prism must be generally used as the moving optic instead of the reflector so as to reduce the measurement error. Nevertheless, the measurement error must be compensated because it's not a negligible error if a rotating angle of the prism is large. In case the reflector must be used as the moving optic, which is unavoidable when the squareness error is measured between two axes, this compensation method can be applied and produces a better result.

Fabrication of Static Fiber Optic Gyrocompass (정적방식 광섬유 자이로콤파스의 제작)

  • 이석정;홍창희
    • Journal of the Korean Institute of Navigation
    • /
    • v.21 no.2
    • /
    • pp.59-67
    • /
    • 1997
  • This paper describe the method and the result of making a fiber optic gyrocompass measuring the heading angles of a ship with a fiber optic sensor. As the method seeking for the heading angles, it is possible to get the heading angles by measuring the output signals from a stationary fiber optic sensor in at least three directions such as a heading direction and other two directions having phase difference ${\phi}1$ and ${\phi}2$ to the heading. We made the static fiber optic gyrocompass by a high performance fiber optic sensor having scale factor of 210mV/deg/s and resolution of 0.5deg/hr using this principle. The accuracy of this system was $0.29^{\circ}$ from 20 numbers of data measuring the arbitrary heading angle.

  • PDF

A Neonatal Case of Septo-Optic Dysplasia with Schizencephaly (분열뇌증을 동반한 중격 시신경 형성장애 신생아 1례)

  • Lee, Won-Hee;Kim, Eun-Young;Park, Sang-Kee
    • Neonatal Medicine
    • /
    • v.16 no.1
    • /
    • pp.81-84
    • /
    • 2009
  • Septo-optic dysplasia is a rare congenital disorder characterized by the absence of the septum pallucidum, hypoplasia of the optic chiasma and nerves, and various types of hypothalamic-pituitary dysfunction. Schizencephaly is an abnormal cleft in the brain, lined with gray matter which may communicate with the ventricular system. Septo-optic dysplasia with schizencephaly is associated with endocrinologic disorders, visual impairment, mental retardation, and seizures. We report a case of septo-optic dysplasia with schizencephaly which was diagnosed in the early neonatal period.

Dynamical Characteristics of a Fiber-Optic Strain Gauge by a Single-Mode Fiber-Optic Mach-Zehnder Interferometer (단일모드 광섬유 Mach-Zehnder 간섭계를 이용한 광섬유 스트레인 게이지의 동적 특성)

  • 이기완;홍봉식
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.5
    • /
    • pp.793-801
    • /
    • 1990
  • A single mode fiber-optic Mach-Zehnder interferometer for the measurement of strain is described. A fiber-optic strain gauge with great resolution and wide measurement range is realized. In order to varify the dynamic response, the measurements of strain below 1涅 with frequency range 5-50Hz are compared with a semiconductor strain gauge. We report theoretical evaluation for mechanical analysis, PZT-plate, the phase change in a fiber-optic strain gauge and a semiconductor strain gauge. The dynamical characteristics of a fiber-optic strain gauge and a semiconductor strain gauge output siganl show equivalent behavior. This result is shown in very good usage as the dynamical measurement of the low strain below 1涅 by this system.

  • PDF

Development of an Integrated Optic Transmitter/Deceiver based on Ring-type WDM PON (링형 WDM PON 기반 통합 광송수신기 개발)

  • Park, Young-Ho;Kim, Cheol-Su
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.4
    • /
    • pp.148-152
    • /
    • 2007
  • This paper develops an integrated optic transmitter/receiver based on ring-type WDM PON. The optic transmitter/receiver can transmit real-time images from the CCTV of a remote street without compression and transmit TCP/IP data using an optic fiber. This system can also perform remote controls of the CCTV camera. The developed optic transmitter/receiver can provide the monitoring service of an advanced image quality of remote traffic using a broadband technology.

  • PDF

Recent Development Trends of Fiber Optic Gyroscope in Space Application (우주용 광섬유자이로 개발동향)

  • Jung, Dong-Won;Kim, Jeong-Yong;Oh, Jun-Seok;Roh, Woong-Rae
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.8 no.2
    • /
    • pp.76-85
    • /
    • 2010
  • This paper discusses recent development trends of fiber optic gyroscope (FOG) in space application. Fiber optic gyroscope utilizes Sagnac effect to measure the angular rate of a rotating object in space. Having a rather short development history compared to ring laser gyroscope (RLG), the fiber optic gyroscope, owing to the emerging technologies in fiber optic society and the digital signal processing technique, reveals itself as a noteworthy replacement of the ring laser gyroscope in the space mission. This paper summarizes the current trends of fiber optic gyroscope based on the actual products commercialized in the market over the last decades, while presenting the future development trends of the fiber optic gyroscope in the space exploration.

  • PDF

Applications of fiber optic sensors for structural health monitoring

  • Kesavan, K.;Ravisankar, K.;Parivallal, S.;Sreeshylam, P.
    • Smart Structures and Systems
    • /
    • v.1 no.4
    • /
    • pp.355-368
    • /
    • 2005
  • Large and complex structures are being built now-a-days and, they are required to be functional even under extreme loading and environmental conditions. In order to meet the safety and maintenance demands, there is a need to build sensors integrated structural system, which can sense and provide necessary information about the structural response to complex loading and environment. Sophisticated tools have been developed for the design and construction of civil engineering structures. However, very little has been accomplished in the area of monitoring and rehabilitation. The employment of appropriate sensor is therefore crucial, and efforts must be directed towards non-destructive testing techniques that remain functional throughout the life of the structure. Fiber optic sensors are emerging as a superior non-destructive tool for evaluating the health of civil engineering structures. Flexibility, small in size and corrosion resistance of optical fibers allow them to be directly embedded in concrete structures. The inherent advantages of fiber optic sensors over conventional sensors include high resolution, ability to work in difficult environment, immunity from electromagnetic interference, large band width of signal, low noise and high sensitivity. This paper brings out the potential and current status of technology of fiber optic sensors for civil engineering applications. The importance of employing fiber optic sensors for health monitoring of civil engineering structures has been highlighted. Details of laboratory studies carried out on fiber optic strain sensors to assess their suitability for civil engineering applications are also covered.

Cost Analysis of Monitoring System with Optic Fiber Sensors (광섬유센서를 이용한 모니터링 시스템의 비용 분석)

  • You, Young-Jun;Park, Ki-Tae;Joo, Bong-Chul;Lee, Chin-Hyung
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.4
    • /
    • pp.67-73
    • /
    • 2009
  • Civil infrastructure is the basis facility which builds up the base of national economy operation. Consequently unexpected sudden abnormal condition of civil infrastructure causes private and national property loss and moreover can spread social issue. Therefore, continuous maintenance and safety management for the civil infrastructures should be handled with great weight. Monitoring system for managing bridge maintenance was introduced first in the early of 1990s and has been developed up to real time measurement and analysis. Thesedays another system using fiber optic sensors is being developed. This paper presents the cost analysis of bridge monitoring system with fiber optic sensors which is gathering attention. Various cases were considered and the results were compared with that of monitoring system with electronic resistant type sensors widely used. As a results, fiber optic sensor system has good advantages in various cases, and a1so cost effectiveness compared to conventional sensor system.

  • PDF

Operating Characteristic Analysis of Optic Temperature Sensor for Overheat Detection in Panel Board (분전함에서 이상발열 감지를 위한 광온도센서의 동작특성 분석)

  • Moon, Hyun-Wook;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.100-106
    • /
    • 2009
  • In this study, methods of overheat detection at the coupling or wire in electrical facility are investigated, operating characteristic about the optic temperature sensor for continuous on-line temperature monitoring in diagnostics system of electrical facility is analyzed. Heating sources in the experiment for operating characteristics of optic temperature sensor use black body and hot plate, output voltage of optic temperature sensor in accordance with temperature variation is analyzed. Overheat generation due to poor contact at the circuit breaker in panel board detects using a thermocouple, infrared thermal camera and optic temperature sensor, and experiment results are analyzed. The effect of optic temperature sensor is the same that of other methods. These results expect to use basic research material for adjusting field of electrical diagnostics system using RFID type optic temperature sensor in the near future.

Development of a Fast Alignment Method of Micro-Optic Parts Using Multi Dimension Vision and Optical Feedback

  • Han, Seung-Hyun;Kim, Jin-Oh;Park, Joong-Wan;Kim, Jong-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.273-277
    • /
    • 2003
  • A general process of electronic assembly is composed of a series of geometric alignments and bonding/screwing processes. After assembly, the function is tested in a following process of inspection. However, assembly of micro-optic devices requires both processes to be performed in equipment. Coarse geometric alignment is made by using vision and optical function is improved by the following fine motion based on feedback of tunable laser interferometer. The general system is composed of a precision robot system for 3D assembly, a 3D vision guided system for geometric alignment and an optical feedback system with a tunable laser. In this study, we propose a new fast alignment algorithm of micro-optic devices for both of visual and optical alignments. The main goal is to find a fastest alignment process and algorithms with state-of-the-art technology. We propose a new approach with an optimal sequence of processes, a visual alignment algorithm and a search algorithm for an optimal optical alignment. A system is designed to show the effectiveness and efficiency of the proposed method.

  • PDF