• Title/Summary/Keyword: Ophthalmic lens

Search Result 522, Processing Time 0.022 seconds

The Effect of Physical and Chemical Stimuli on Ophthalmic Lens Coatings (물리적, 화학적 자극이 안경 렌즈의 코팅에 미치는 영향)

  • Kim, So Ra;Kim, Ji Yoon;Kim, Ka Young;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.237-245
    • /
    • 2011
  • Purpose: The present study was conducted to investigate whether certain repeated physical and/or chemical stimuli added on ophthalmic lenses might induce any changes of the functions of lens coatings. Methods: The changes in lens surface, light transmittance, foggy duration, durability of ophthalmic lenses were determined after the application of tearing-off with tape, rubbing with acetone, soaking in acetone or distilled water of ophthalmic lens (CR-39 material) as physical and/or chemical stimuli. Results: The change of ophthalmic lens surface was detected after soaking in acetone for longer than 30 minutes by observing the lens surface to figure out the functional change of hard coating. The ophthalmic lens soaked in distilled water for 180 minutes showed little functional change of anti-reflection coating as 1% by measuring light transmittance of lens. However, the function of anti-reflection coating was almost disappeared after the ophthalmic lens was soaked in acetone for 60 minutes. The foggy duration of ophthalmic lens soaked in acetone was increased by estimating foggy duration of lens. The lens coating was shown to be defected when the pre-damaged ophthalmic lenses were torn off with tape, rubbed with acetone and soaked in distilled water or acetone by observing pre-damaged lens surface to evaluate its durability. Conclusions: The careful management during ophthalmic lens dispensing or usual eyeglass wearing is needed since the change in ophthalmic lens coatings was shown by repeated physical and/or chemical stimuli.

Measurement of Refractive Power by Reflective image on the Negative Spherical Lens ((-) 구면 렌즈 면의 반사상에 의한 굴절력 측정)

  • Choi, Woon-Sang;Kim, Tae-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.417-421
    • /
    • 2004
  • We can see that two images of reflection are observed on the surface of a ophthalmic lens. These are the image reflected from front surface and back surface of lens, respectively. The reflective image shows to be affect by surface refractive power of front and back surface of lens. Total refractive power of lens is calculated by refractive power of front and back surface of lens. Accordingly, the ratio of image on the lens surface is able to measure refractive power of ophthalmic lens without helping of the lensmeter. The ratio of two reflective image measured on the lens surface is compared with the calculated ratio by the power measurement.

  • PDF

Preparation and Performance Analysis of Ophthalmic Polymer Using SWCNT and SWCCNT

  • Shin, Su-Mi;Sung, A-Young
    • Korean Journal of Materials Research
    • /
    • v.29 no.12
    • /
    • pp.735-740
    • /
    • 2019
  • The purpose of this study is to fabricate an ophthalmic lens by copolymerizing two types of carbon nanotubes and hydrophilic hydrogel lens materials, and to investigate its application as an ophthalmic lens material by analyzing its physical properties and antimicrobial effect. For polymerization, HEMA (2-hydroxyethyl methacrylate), EGDMA (ethylene glycol dimethacrylate), a crosslinking agent, and AIBN (azobisisobutyronitrile), an initiator, are used as a basic combination, and a single-walled carbon nanotube and a single-walled, carboxylic-acid-functionalized carbon nanotube are used as additives. To analyze the physical properties, the water content, refractive index, breaking strength, and antimicrobial effect of the fabricated lenses are measured. The fabricated lenses satisfies all the basic properties of the basic hydrogel ophthalmic lens. The water content increases with increasing amount of additive and decreases with addition of 0.2 % ratio of nanoparticles. The refractive index is inversely proportional to the water content result. As a result of the antimicrobial test of the fabricated lens, the addition of carbon nanotubes shows an excellent antimicrobial effect. Therefore, it is considered that the fabricated lens can be applied as a functional material for basic ophthalmic hydrogel lenses.

The Developmental Process of Blur Circle along to the Variation of a Refractive Power for Hyperopia (원시에서 교정굴절력변화에 따른 착란원 크기)

  • Choi, Woon Sang;Jung, Soo-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.155-157
    • /
    • 2000
  • A variable process of blur circle is calculated for a artificial hyperopia. The calculation is used to the value of Gullstrand's theoretical eye and a method of geometrical optics. The theoretical eye simplified a entrance pupil and the retina. Ophthalmic lens and eye changed a equivalent lens. Refractive power of a equivalent lens is converted to focal length within theoretical eye, and this is calculated about relation of a blur circle on the retina and ophthalmic lens.

  • PDF

Protein Absorption and Characterization of Hydrogel Polymer Containing 2-Methacryloyloxyethyl Phosphorylcholine as Additive

  • Kim, Duck-Hyun;Sung, A-Young
    • Journal of Integrative Natural Science
    • /
    • v.9 no.4
    • /
    • pp.249-254
    • /
    • 2016
  • This study evaluated the physical and optical characteristics of hydrophilic ophthalmic polymer with addition of 2-methacryloyloxyethyl phosphorylcholine in the basic hydrogel ophthalmic lens material, and in particular, the utility of 2-methacryloyloxyethyl phosphorylcholine as an ophthalmic contact lens material for ophthalmologic devices was investigated. In this study 2-methacryloyloxyethyl phosphorylcholine were used as additives. For the preparation of hydrogel lens 2-hydroxyethyl methacrylate, methyl methacrylate, acrylic acid and a cross-linker EGDMA were copolymerized in the presence of AIBN as an initiator. The physical properties of the produced polymers were measured as followings. The refractive index of 1.433~1.393, water content of 35.95~53.16%, contact angle of $70.6{\sim}51.24^{\circ}$, UVB transmittance of 81.2~82.4%, UV-B transmittance of 81.2~82.4% and visible transmittance of 91.4~92.2% were obtained. Also, in case of protein absorption, the measurement showed that absorbance of Reference and MPC-10 sample was 0.2598 and 0.2250 respectively. Based on the results of this study, ophthalmic lens material containing 2-methacryloyloxyethyl phosphorylcholine is expected to be used usefully as a material for high wettability and inhibitor of protein adsorption for ophthalmic hydrogel lens.

A method to extract the aspherical surface equation from the unknown ophthalmic lens (형상 분석에 의한 안경렌즈의 비구면 계수 추출 방법)

  • 이호철;이남영;김건희;송창규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.430-433
    • /
    • 2004
  • The ophthalmic lens manufacturing processes need to extract the aspherical surface equation from the unknown surface since its real profile can be adjusted by the process variables to make the ideal curve without the optical aberration. This paper presents a procedure to get the aspherical surface equation of an aspherical ophthalmic lens. Aspherical form generally consists of the Schulz formula to describe its profile. Therefore, the base curvature, conic constant, and high-order polynomial coefficient should be set to the original design equation. To find an estimated aspherical profile, firstly lens profile is measured by a contact profiler, which has a sub-micrometer measurement resolution. A mathematical tool is based on the minimization of the error function to get the estimated aspherical surface equation from the scanned aspherical profile. Error minimization step uses the Nelder-Mead simplex (direct search) method. The result of the refractive power measurement is compared with the curvature distribution on the estimated aspherical surface equation

  • PDF

A Study on the Optical Properties of Contact Lens Analyzer CA-20 (CONTACT LENS ANALYZER CA-20의 광학계 성능 조사)

  • Ji, Taeksang;Lim, Hyeonseon;Kim, Bonghwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.199-203
    • /
    • 2000
  • Magnification shall large to test a surface of a contact lens also chromatic aberration and distortion to be removed. Be used of this study a contact lens analyzer is "CONTACT LENS ANALYZER CA-20", it is a good analyzer to suitable with surface test 16 times of big magnification and distortion.

  • PDF

A study on using practice of contact lens and side effects (연성콘택트렌즈 착용자의 실태와 부작용에 대한 연구)

  • Kang, Hyang Nyeo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.69-73
    • /
    • 2002
  • This questionnaire studied the status of wear and care for soft contact lens, of 200students wearing loft contact lens. 50% of man wore soft contact lens, 8 hours and 52% of woman wore soft contact lens 10 hours per a day, 51% of man has worn soft contact lens 3 years 45% of woman has worn soft contact lens 3 year. For the side effects of wearing contact lens 39% of man soft contact lens wearers experienced eye congestion, 72% of woman soft contact lens wearers dryness eyes.

  • PDF

Fabrication Technique of Nanoemulsion Using Silicone Oil and Application as Hydrophilic Ophthalmic Lens

  • Hye-In Park;A-Young Sung
    • Korean Journal of Materials Research
    • /
    • v.34 no.7
    • /
    • pp.315-320
    • /
    • 2024
  • In order to maximize the function and increase the compatibility of silicone hydrogel lens, this study compared and analyzed the properties of Amino modified silicone oil using mini and microemulsion technique, respectively. Optical and physical properties were evaluated by spectral transmittance, refractive index, water content, oxygen transmittance and contact angle measurements to evaluate the performance of the manufactured hydrogel lens. The spectral transmittance results revealed the copolymerization method lens showed 31 % of the visible light area, which did not satisfy the basic optical properties. However, the lens using the mini and microemulsion materials showed more than 90 % of the visible light area, satisfying the optical characteristics. In addition, all physical properties were superior to a basic hydrogel lens. The mini and microemulsion techniques effectively improved the stability and function of the ophthalmic hydrogel lens and are considered a promising ways of manufacturing an ophthalmic hydrogel contact lens with increased compatibility and stability.

An Optical Characteristic Research of a Netspec Lens (네츠팩 렌즈의 광학적 특성 연구)

  • Lee, Dong-Hee;Kim, Dae-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.85-90
    • /
    • 2003
  • A Netspec lens has the form having the 2-dimensional mesh coating on a general ophthalmic lens. It is known that it makes the ophthalmic image see more clearly, reducing the ophthalmic fatigue and that the transmittance of it for ultraviolet and infrared rays is lower. We need to prove this characteristic scientifically. So, in this study, we applied the Kirchhoff's scalar wave theory to the Netspec lens and induced a transmittance expression. And we made the program of which simulation can explain the transmittance effect of the Netspec lens. Also, we tried the interpreting about the result of the simulation. Finally, we have known that this simulation program can be used to adjust the transmittance of the light according to the wavelength.

  • PDF