• Title/Summary/Keyword: Ophthalmic imaging

Search Result 29, Processing Time 0.022 seconds

Effects of anesthetics on resistive index of the medial long posterior ciliary artery and ophthalmic artery using color doppler imaging

  • Choi, Ho-jung;Lee, Young-won;Yoon, Jung-hee;Yeon, Seong-chan;Lee, Hyo-jong;Lee, Hee-chun
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.3
    • /
    • pp.423-427
    • /
    • 2005
  • Color Doppler imaging (CDI) was carried out to evaluate the anesthetics effect on ophthalmic circulation using CDI-derived resistive index (RI) values. CDI was preformed on 24 dogs, and RI values were calculated for the medial long posterior ciliary artery (mLPCA) and ophthalmic artery (OA) before and after administration of anesthetics. After administration of benoxinate or acepromazine, a significant change of the mLPCA RI was not found. But, a significant decrease of the RI following ketamine (p < 0.001) or xylazine (p < 0.01) administration could be observed as compared with the self-control. Mean RI value of OA also showed this same trend. Intraocular pressure was significantly decrease following benoxinate (p < 0.01), acepromazine (p < 0.01), and xylazine (p < 0.001) administration within normal range. The results suggest that some anesthetics influence on ophthalmic vascular resistance. Therefore, chemical restraint was carefully used in clinical application of CDI-derived RI measurement. Particularly, benoxinate and acepromazine is useful chemical restraint without a change of the ophthalmic vascular resistance.

Array-Based Real-Time Ultrasound and Photoacoustic Ocular Imaging

  • Nam, Seung Yun;Emelianov, Stanislav Y.
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.151-155
    • /
    • 2014
  • Although various ophthalmic imaging methods, including fundus photography and optical coherence tomography, have been applied for effective diagnosis of ocular diseases with high spatial resolution, most of them are limited by shallow imaging penetration depth and a narrow field of view. Also, many of those imaging modalities are optimized to provide microscopic anatomical information, while functional or cellular information is lacking. Compared to other ocular imaging modalities, photoacoustic imaging can achieve relatively deep penetration depth and provide more detailed functional and cellular data based on photoacoustic signal generation from endogenous contrast agents such as hemoglobin and melanin. In this paper, array-based ultrasound and photoacoustic imaging was demonstrated to visualize pigmentation in the eye as well as overall ocular structure. Fresh porcine eyes were visualized using a real-time ultrasound micro-imaging system and an imaging probe supporting laser pulse delivery. In addition, limited photoacoustic imaging field of view was improved by an imaging probe tilting method, enabling visualization of most regions of the retina covered in the ultrasound imaging.

Evaluation of Resistive Index Using Color Doppler Imaging in Canine Ophthalmic Vasculature (개의 안혈관에 대한 컬러도플러초음파를 사용한 저항지수의 평가)

  • Lee, Hee-Chun;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.20 no.2
    • /
    • pp.145-149
    • /
    • 2003
  • Color Doppler imaging(CDI) was carried out to determine CDI-derived resistive index(RI) values of normal canine ophthalmic vasculature and its reproducibility. CDI was performed on 58 dogs. and normal ranges of RI value were calculated for the medial long posterior ciliary artery(mLPCA), ciliary artery(CA), and ophthalmic artery(OA). Ophthalmic vascular RI values of normal dogs were 0.67$\pm$0.07, 0.70$\pm$0.06, and 0.80$\pm$0.04 in mLPCA, CA, and OA, respectively. Means of RT value of all vessel had no statistically significant difference by sex, fellow orbits, and skull type. The results suggest that color Doppler imaging is a noninvasive test which has the advantage of providing objective measurements of blood flow velocity parameter in the canine eye and orbit.

Implementation of Cost-effective Common Path Spectral Domain Free-hand Scanning OCT System

  • Shoujing Guo;Xuan Liu;Jin U. Kang
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.176-182
    • /
    • 2023
  • Optical coherence tomography (OCT) is being developed to guide various ophthalmic surgical procedures. However, the high cost of the intraoperative OCT system limits its availability mostly to the largest hospitals and healthcare systems. In this paper, we present a design and evaluation of a low-cost intraoperative common-path free-hand scanning OCT system. The lensed fiber imaging probe is designed and fabricated for intraocular use and the free-hand scanning algorithm that could operate at a low scanning speed was developed. Since the system operates at low frequencies, the cost of the overall system is significantly lower than other commercial intraoperative OCT systems. The assembled system is characterized and shows that it meets the design specifications. The handheld OCT imaging probe is tested on multilayer tape phantom and ex-vivo porcine eyes. The results show that the system could be used as an intraoperative intraocular OCT imaging device.

Development of Hand-held OCT probe for Ophthalmic Imaging (안구 영상을 위한 OCT용 손잡이 형 프로브의 개발)

  • Cho, Nam-Hyun;Jung, Woong-Gyu;Jung, Un-Sang;Sephen, A.Boppart;Shim, Jae-Hoon;Kim, Jee-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.1
    • /
    • pp.24-30
    • /
    • 2011
  • We have developed a hand-held probe for an ophthalmic OCT system. The hand-held probe for imaging was designed to be compact and portable. The cornea and retinal images were acquired by replacing the objective lens at the front of the probe. To verify the performance of the hand-held OCT probe, we acquired two dimensional OCT image of the rat eye in vivo and reconstructed three dimensional rat eye rendering images. In vivo 3D OCT images were showed distinct structural information in the posterior and anterior chamber with minimal motion artifacts. Thereby, OCT imaging speed is suitable for an dynamic in vivo experiment.

Applications of Digital Holography in Biomedical Microscopy

  • Kim, Myung-K.
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.77-89
    • /
    • 2010
  • Digital holography (DH) is a potentially disruptive new technology for many areas of imaging science, especially in microscopy and metrology. DH offers a number of significant advantages such as the ability to acquire holograms rapidly, availability of complete amplitude and phase information of the optical field, and versatility of the interferometric and image processing techniques. This article provides a review of the digital holography, with an emphasis on its applications in biomedical microscopy. The quantitative phase microscopy by DH is described including some of the special techniques such as optical phase unwrapping and holography of total internal reflection. Tomographic imaging by digital interference holography (DIH) and related methods is described, as well as its applications in ophthalmic imaging and in biometry. Holographic manipulation and monitoring of cells and cellular components is another exciting new area of research. We discuss some of the current issues, trends, and potentials.

Optical System Design for Real-Time 3-Dimension Ophthalmoscope (실시간 3차원 검안경의 광학설계)

  • Lee, Soak-Hee;Yang, Yun-Sik;Choe, Oh-Mok;Sim, Sang-Hyun;Doo, Ha-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.35-39
    • /
    • 2003
  • The display technology on the retina is the key role in inspecting the condition of the patients. 2-dimensional retina image is widely used in the eye examination as of today. Recently, 3-dimensional retina image ones have been introduced to this area, but the quality of the image is not fully satisfied to the operator. For the purpose of developing 3-D retina imaging instrument, the optimization of a 3-D retina imaging system using Code-V tool was investigated in this thesis. He-Ne laser having the wavelength 632.8 nm was used to make a power source to detect the retina. Several lenses and mirrors installed on sledge which were developed to perform focus control on 3-D device were designed to make a beam focusing and direct line. Polygon scanner having 24 mirror facets and galvanometer making tilting movement were utilized to make a 2-D laser plane. Also, design of eye ball had been fulfilled to see the focus of the 2-D plane. Reflected ray from retina detected on the sensor array with the same path. All cognitive components were optimized for aberration correction in order to focus on retina. Results of optimization were compared to those of initial designed optics system. On the basis of above results, the result of third aberration has been corrected to stable values to the optical system. MTF evaluating the resolution of an image has been closely correlated to the diffraction limit and PSF indicating the strength distribution of an image has shown the SR value as 0.9998 having high performance. The possibility of new and powerful 3-D retina image instrument was verified by simulating each component of the instrument by Code-V.

  • PDF

Paradoxical Exacerbation of Symptoms with Obstruction of the Venous Outflow after Gamma Knife Radiosurgery for Treatment of a Dural Arteriovenous Fistula of the Cavernous Sinus

  • Ko, Jun Kyeung;Cho, Won Ho;Lee, Tae Hong;Choi, Chang Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.2
    • /
    • pp.127-130
    • /
    • 2015
  • A 59-year-old female presented with progressive right proptosis, chemosis and ocular pain. An imaging work-up including conventional catheter angiography showed a right-sided dural arteriovenous fistula of the cavernous sinus, which drained into the right superior petrosal sinus, right superior ophthalmic vein, and right inferior ophthalmic vein, and cortical venous reflux was seen via the right petrosal vein in the right posterior fossa. After failure of transvenous embolization, the patient underwent Gamma Knife radiosurgery (GKRS). At one month after GKRS, she developed increasing ocular pain and occipital headache. Repeat angiography showed partial obliteration of the fistula and loss of drainage via the superior and inferior ophthalmic veins with severe congestion, resulting in slow flow around the right cerebellar hemisphere. Prompt transarterial embolization relieved the patient's ocular symptoms and headache. We report on a case of paradoxical exacerbation of symptoms resulting from obstruction of the venous outflow after GKRS for treatment of a dural arteriovenous fistula of the cavernous sinus.

Study on design and measurement of aspheric (비구면의 설계와 측정)

  • Park, Dong Hwa
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.133-138
    • /
    • 2005
  • As Aspheric lenses have producted to development for disadvantage of spherical lenses, the purpose of use on aspheric lenses is in improvement of the imaging quality and decrement of the number of lenses used, they are used for lessen the mass and volume in optical science. The skills to produce optical data and the aspheric are seen as high technology today. The optical science which is composed of aspheric provides broadening view of things and high efficiency. In addition, it provides many advantages such as providing image and reducing the weight. Now, I study with techniques of processing and measuring aspheric to satisfy the necessity of increasing in aspheric data. Furthermore. I emphasize that the techniques of producing, measuring, and evaluating in the aspheric lenses have constantly developing today.

  • PDF

Ophthalmic Manifestations of Cavernous Sinus Syndrome in a Yorkshire Terrier Dog

  • Sehan Shin;Sol Kim;Seonmi Kang;Jihye Choi;Kangmoon Seo
    • Journal of Veterinary Clinics
    • /
    • v.40 no.5
    • /
    • pp.360-364
    • /
    • 2023
  • A 7-year-old castrated male Yorkshire Terrier presented for a palpable mass of the right neck with ophthalmic signs of conjunctival hyperemia and anisocoria with fixed mydriatic pupil of the right eye. Clinical examination findings included the absence of direct and consensual pupillary light reflexes, external and internal ophthalmoplegia, and corneal hypoesthesia with incomplete blinking of the right eye. Magnetic resonance imaging and computed tomography revealed a mass extending from the right cavernous sinus to the orbital fissure with neighboring bone lysis. Cytological examination of fine-needle aspiration samples of the mass revealed a neuroendocrine tumor. The owner declined further diagnosis and did not wish to care for the dog receiving chemotherapy. This study describes the importance of investigating neuro-ophthalmic findings, which might provide clues for the localization of lesions, including tumors, to aid in diagnosis.