• Title/Summary/Keyword: Operative Restoration

Search Result 87, Processing Time 0.028 seconds

Comparison of light-transmittance in dental tissues and dental composite restorations using incremental layering build-up with varying enamel resin layer thickness

  • Rocha Maia, Rodrigo;Oliveira, Dayane;D'Antonio, Tracy;Qian, Fang;Skif, Frederick
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.2
    • /
    • pp.22.1-22.9
    • /
    • 2018
  • Objectives: To evaluate and compare light-transmittance in dental tissues and dental composite restorations using the incremental double-layer technique with varying layer thickness. Materials and Methods: B1-colored natural teeth slabs were compared to dental restoration build-ups with A2D and B1E-colored nanofilled, supra-nanofilled, microfilled, and microhybrid composites. The enamel layer varied from 0.3, 0.5, or 1.2 mm thick, and the dentin layer was varied to provide a standardized 3.7 mm overall sample thickness (n = 10). All increments were light-cured to $16J/cm^2$ with a multi-wave LED (Valo, Ultradent). Using a spectrophotometer, the samples were irradiated by an RGB laser beam. A voltmeter recorded the light output signal to calculate the light-transmittance through the specimens. The data were analyzed using 1-way analysis of variance followed by the post hoc Tukey's test (p = 0.05). Results: Mean light-transmittance observed at thicker final layers of enamel were significantly lower than those observed at thinner final layers. Within 1.2 mm final enamel resin layer (FERL) thickness, all composites were similar to the dental tissues, with exception of the nanofilled composite. However, within 0.5 mm FERL thickness, only the suprananofilled composite showed no difference from the dental tissues. Within 0.3 mm FERL thickness, none of the composites were similar to the dental tissues. Conclusions: The supra-nanofilled composite had the most similar light-transmittance pattern when compared to the natural teeth. However, for other composites, thicker FERL have a greater chance to match the light-transmittance of natural dental tissues.

Retrospective study of fracture survival in endodontically treated molars: the effect of single-unit crowns versus direct-resin composite restorations

  • Kanet Chotvorrarak;Warattama Suksaphar;Danuchit Banomyong
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.29.1-29.11
    • /
    • 2021
  • Objectives: This study was conducted to compare the post-fracture survival rate of endodontically treated molar endodontically treated teeth (molar ETT) restored with resin composites or crowns and to identify potential risk factors, using a retrospective cohort design. Materials and Methods: Dental records of molar ETT with crowns or composite restorations (recall period, 2015-2019) were collected based on inclusion and exclusion criteria. The incidence of unrestorable fractures was identified, and molar ETT were classified according to survival. Information on potential risk factors was collected. Survival rates and potential risk factors were analyzed using the Kaplan-Meier log-rank test and Cox regression model. Results: The overall survival rate of molar ETT was 87% (mean recall period, 31.73 ± 17.56 months). The survival rates of molar ETT restored with composites and crowns were 81.6% and 92.7%, reflecting a significant difference (p < 0.05). However, ETT restored with composites showed a 100% survival rate if only 1 surface was lost, which was comparable to the survival rate of ETT with crowns. The survival rates of ETT with composites and crowns were significantly different (97.6% vs. 83.7%) in the short-term (12-24 months), but not in the long-term (> 24 months) (87.8% vs. 79.5%). Conclusions: The survival rate from fracture was higher for molar ETT restored with crowns was higher than for ETT restored with composites, especially in the first 2 years after restoration. Molar ETT with limited tooth structure loss only on the occlusal surface could be successfully restored with composite restorations.

A Study on the Analysis of the Marketing Distribution in Landscape Materials (조경자재(造景資材)의 유통실태분석(流通實態分析)에 관(關)한 연구(硏究))

  • Lee, Seok Rae;Lee, Jae Keun;Choi, Jong Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.1
    • /
    • pp.57-64
    • /
    • 2003
  • This study aims to discuss the characteristics on marketing distribution of landscape materials after consideration in the side of cognition on the present condition of marketing which is important factors for analysis in understanding the market of landscape materials. To do this, the investigation of marketing distribution are to collect data refer to purchases and sales reports and questionnaires, these results are used to analyzed the operative factor of forming market structure and problematic, improvement spot of marketing distribution. The periodic range of this paper is limited on 609 landscape materials and examination was performed from 21.Feb. to 15.Mar, in 2002. The results of the whole prices trends and marketing distribution survey can be summarized as follows : 1. Differences of cognition on marketing distribution among four group toward problematic spot on product and marketing of landscape materials was summarized as follows : 1) Group of landscape design : Interest of government, Various articles. 2) Group of landscape construction : Communication of marketing information, Role of intermediary ecc. 3) Group of landscape materials and cooperation between company and university : Interest of government ecc, 2. Differences of cognition on marketing distribution among four group toward improvemental spot on product and marketing of landscape materials was summarized as follows : 1) Group of landscape design and construction : Network of marketing distribution on landscape materials, Criterion of articles, Quality adiministration through establishment of sale level ecc.. 2) Group of landscape materials : Employment of specialist education program ecc.. 3) Group of cooperation between company and university : Conscious reformation of comsumer ecc.

The Manufacture of Custom Made 3D Titanium Implant for Skull Reconstruction

  • Cho, Hyung Rok;Yun, In Sik;Shim, Kyu Won;Roh, Tai Suk;Kim, Yong Oock
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.13-15
    • /
    • 2014
  • Nowadays, with advanced 3D printing techniques, the custom-made implant can be manufactured for the patient. Especially in skull reconstruction, it is difficult to design the implant due to complicated geometry. In large defect, an autograft is inappropriate to cover the defect due to donor morbidity. We present the process of manufacturing the 3D custom-made implant for skull reconstruction. There was one patient with skull defect repaired using custom-made 3D titanium implant in the plastic and reconstructive surgery department. The patient had defect of the left parieto-temporal area after craniectomy due to traumatic subdural hematoma. Custom-made 3D titanium implants were manufactured by Medyssey Co., Ltd. using 3D CT data, Mimics software and an EBM (Electron Beam Melting) machine. The engineer and surgeon reviewed several different designs and simulated a mock surgery on 3D skull model. During the operation, the custom-made implant was fit to the defect properly without dead space. The operative site healed without any specific complications. In skull reconstruction, autograft has been the treatment of choice. However, it is not always available and depends on the size of defect and donor morbidity. As 3D printing technique has been advanced, it is useful to manufacture custom-made implant for skull reconstruction.

Immediate loading of mandibular single implant by using surgical guide and modeless digital prosthesis: a case report (수술용 가이드와 modeless 디지털 보철물을 이용한 하악 구치부 단일 임플란트 즉시 하중 증례)

  • Lim, Hyun-jeong;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2017
  • In this case report, immediate loading of an implant-supported single-tooth prosthesis through complete digital workflow. A patient presented for restoration of missing a single tooth in the mandibular first molar. The digital impression was made with intraoral scanner and implant was placed using surgical guide pre-fabricated with pre-operative computed tomography (CT) and scan data. After 1 week later, prefabricated customized abutment and provisional restoration were connected for immediate loading. After 8 weeks later, abutment level impression was taken by intraoral scanner. At 3 months later from implant installation, monolithic zirconia crown were fabricated. This clinical report presents satisfying result in accuracy and patient satisfaction. A completely modeless digital procedure met expectations regarding precision, esthetics, and functionality.

MULTIDISCIPLINARY MANAGEMENT FOR AMELOGENESIS IMPERFECTA PATIENT WITH SKELETAL C III MALOCCLUSION (골격성 3급 부정 교합을 지닌 법랑질 형성 부전증 환자의 복합적 치료)

  • Oh, Jung-Hwan;Kim, Hak-Ryeol;Hwang, Yoon-Tae;Kim, Yeo-Gab;Ryu, Dong-Mok;Lee, Baek-Soo;Yoon, Byung-Wook;Jeon, Joon-Hyeok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.1
    • /
    • pp.91-96
    • /
    • 2007
  • Amelogenesis imperfecta (AI) is a hereditary disease that affects enamel formation. The patients with AI have esthetic and functional problems due to damage of multiple teeth. So most AI patients resolve these problem through the conservative and prosthodontic treatments. In our case, It was difficult to obtain good results in means of conservative and prosthodontic treatments, because the AI patient had skeletal Class III malocclusion. Moreover, because of vertical dimension loss due to severe dental caries and maxillofacial skeletal disharmony, the ordinary prosthodontic treatment was troublesome. So we planned orthognathic surgery to resolve these problems. After the endodontic treatment, temporary restoration was delivered for stable post-operative occlusion. Then orthognathic surgery was done, and final restoration was delivered in stable period. We obtained satisfactory results in esthetic and functional aspects through multidisciplinary management(conservative treatment, prosthodontics and orthognathic surgery).

A Fatigue Toughness and Polymerization Shrinkage of Post-cure Heat Treated Composite Resins (광중합 복합레진에 대한 가열처리 피로내성 및 중합수축에 미치는 영향)

  • Oh, Won-Mann;Rhu, Sun-Youl;Son, Ho-Hyun;Okuda, Reiichi;Endo, Tastuo;Kudo, Yoshiyuki
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.135-147
    • /
    • 1994
  • This study was conducted to evaluate whether the fatigue toughness of visible light cured composite resins could be improved and how much percentage of polymerzation shrinkage could be affected by additional heat treatment. 7 materials were investigated for this study: P-50, Lite-fil CR inlay, Pekafil, Clearfil CR inlay, Clearfil photo posterior, Z -100 and Progress. Diametral tensile strengths and linear shrinkages of composite resins were taken under visible light cured and additional post-cure heated condition and compared each other. A fatigue toughness of above materials was evaluated by measuring diametral tensile strength after they were repeatedly loaded with 120kgf/$cm^2$ up to 3000 cycles. The results obtained were as follows : 1. When composite resins were cured just by visible light, Lite fil CR inlay, Z -100 and Progress showed respectively higher diametral tensile strength than the other materials. Clearfil CR inlay, Clearfil photo posterior and Progress exhibited strong fatigue toughness compared to P-50 and Pekafil. 2. Post-cure heat treated composite resins had higher diametral tensile strengths than visible light cured composite resins at fatigue toughness test as well as no fatigue toughness test. 3. When Composite resins were additionally polymerized by post-cure heat treatment, P-50 showed weak fatigue toughness, on the contrary, Clearfil CR inlay, Z-100, Progress showed strong one. 4. When composite resins were cured just by visible light, percentage of polymerization linear shrinkage was the lowerest in Clearfil CR inlay, followed by, in ascending order, Clearfil photo posterior, Lite-fil CR inlay, Progress, Pekafil, P-50, and Z-100. In the case of post- cure heat treated composite resins, percentage of linear shrinkage was the lowest in Clearfil photo posterior, followed by, in ascending order, Lite-til CR inlay, Clearfil CR inlay, Progress, P-50, Pekafil and Z-100. 5. Percentage of polymerization linear shrinkage was greater in the post-cure heat treated composite resins than in the visible light cured composite resins and linear shrinkage increased significantly in Pekafil, Clearfil CR inlay, and Clearfil photo posterior between at the visible light cured and at the post-cure heat treated condition. The above results is saying that additional post-cure heat treatment on the composite resins for posterior restoration is able to affect on improvement of strength and fatigue toughness and lead to increase polymerization of composite resins.

  • PDF

Alternative Use of Inferior Blow-out Fracture Reduction with Urinary Balloon Catheter (풍선 달린 카테터를 이용한 안저 파열 골절 정복의 선택적 사용)

  • Park, Sung Hoon;Yang, Ho Jik
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.729-734
    • /
    • 2007
  • Purpose: The operative treatment for blow-out fracture involves restoration of intra-orbital soft tissue and bony structural integrity. There are several methods for reconstruction of inferior blow out fracture. We report reduction of inferior blow-out fracture with urinary balloon catheter in comparison with $Medpor^{(R)}$ using group to complication rate. Methods: A retrospective study was performed on 67 patients who underwent inferior orbital blow-out fracture reconstruction with $Medpor^{(R)}$ implant or urinary balloon catheter following between 2003 and 2006. Hospital records were reviewed especially for preoperative and postoperative enophthalmos, diplopia, extraocular muscle movement limitations, and hypoesthesia between $Medpor^{(R)}$ implant group and balloon catheter using group. Results: There was no significant statistical difference between both groups on incidence of postoperative complications of enophthalmos, diplopia, extraocular muscle movement limitations, and hypoesthesia. Postoperative infection, ectropion were absent in both groups.Conclusion: The use of urinary balloon catheter is simple, fast and inexpensive. Urinary balloon catheter is an alternative and reliable use for reduction of inferior orbital blow-out fracture.

Sensory Restoration of Abdomen after Free TRAM Flap for Breast Reconstruction

  • Sung, Kun Yong;Ahn, Hee Chang;Hwang, Weon Jung;Jo, Dong In
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.71-75
    • /
    • 2005
  • The purpose of this study is to assess abdominal sensation after free TRAM flap for breast reconstruction. 74 patients underwent breast reconstruction with free TRAM flap by authors and were followed up to check the sensation on abdomen following the surgery at the out patient clinic. They are compared with 20 female volunteer controls. Abdomens were divided into 13 zones, and assessed for superficial touch, superficial pain, temperature, two-point discrimination, and vibration. For all five sensory modalities, subjects were found to have decreased sensation in the umbilical and infraumbilical regions. This was statistically significant compared with controls. Division following pedicle dissection showed more reduction of sensation than non-dissection side. Both Inguinal areas below the donor site closure also showed markedly decreased sensation. Sensation on most area of abdomen recovered in postoperative 1 year, however, there were remained hypoesthesia in umbilical and infraumbilical area after post operative 1 year. This study clearly demonstrates that there is a significant and persistent reduction in abdominal sensibility following free TRAM flap surgery.

Korean Caries Management by Risk Assessment (K-CAMBRA) (임상가를 위한 특집 1 - 우식위험도평가에 근거한 한국형 치아우식증 관리 모델)

  • Kim, Baek Il
    • The Journal of the Korean dental association
    • /
    • v.52 no.8
    • /
    • pp.456-463
    • /
    • 2014
  • Caries Management by Risk Assessment (CAMBRA), published by California Dental Association in 2003, is a customized caries care system that classifies individuals' caries risk into 4 risk groups based on objective evidences and provides chemical treatments targeted for each caries risk level. However, this system was not only developed but also optimized for situation in the United States, resulting into many limitations to be used in Korea, and thus Korean CAMBRA (K-CAMBRA) that considers the clinical situation in Korea needs to be developed. K-CAMBRA includes various techniques that are newly developed in order to overcome the limitations. First, Q-ray, a new optical technology, is utilized in order to avoid the subjectivity of visual inspection during assessment of disease indicators and risk factors. Moreover, Cariview? that reflects the paradigm shift in cariology as a new form of caries assessment kit is used. In addition, considering the situation in Korea, where it is impossible to use high concentration fluoride product, Oral pack with a customized tray is added to increase the contact time of chemical substance. CAMBRA is believed to be the key clinical tool that overcomes the limitations of the paradigm of the conventional restoration-based surgical model of dentistry. Furthermore, it can be expected that Korean dentists can act as oral physicians who are able to control and care individuals' caries risk rather than operative experts who only care about the outcome of caries.