• Title/Summary/Keyword: Operational fault

Search Result 214, Processing Time 0.028 seconds

Operational Characteristics of Bride Type SFCL Using Switching Operation of Resistive Type HTSC Element (저항형 고온초전도 소자의 스위칭동작을 이용한 브리지타입 고온초전도 전류제한기의 동작 특성)

  • Lim, Sung-Hun;Park, Chung-Ryul;Lee, Jong-Hwa;Ko, Seok-Cheol;Park, Hyeong-Min;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.83-85
    • /
    • 2004
  • We proposed the bridge type fault current limiter(FCL) using switching operation of high-Tc superconducting(HTSC) thin film. The proposed bridge type FCL consists of HTSC thin film, a diode bridge and a dc reactor. The controller for the operation of an interrupter is required in the conventional bridge type FCL to prevent the continuous increase of fault current after a fault happens. On the other hand, the proposed bridge type FCL can limit the fault current without the interrupter and the controller for its operation by the resistance generated when the gradually increased fault current exceeds HTSC thin film's critical current. We calculated the time when the gradually increased fault current started to be limited by the resistance generated in HTSC thin film after a fault happened and confirmed that it could be dependent on the amplitude of source voltage. The experimental results well agreed with the calculated ones from simulation.

  • PDF

Analysis on Simulation and Experiment for Fault Current Limiting Characteristics of SFCL using Magnetic Coupling of Two Coils with Series Connection (직렬연결된 두 코일의 자기결합을 이용한 초전도 전류제한기의 사고전류제한 특성 시뮬레이션 및 실험 분석)

  • Kim, Jae-Chul;Lim, Sung-Hun;Kim, Jin-Seok;An, Jae-Min;Moon, Jong-Fil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.26-30
    • /
    • 2008
  • The simulation and experiment for the fault current limiting characteristics of the superconducting fault current limiter (SFCL) using the magnetic coupling of series connected two coils were performed. The magnetic fluxes generated from two coils were canceled out during a normal time. However, the resistance generation of high-Tc superconducting (HTSC) element after a fault occurrence allows the magnetic fluxes of two coils and contributes to the fault current limiting operation. Through the computer simulation and the current limiting experiment for this SFCL, the operational current and the limiting impedance of the SFCL could be confirmed to be improved by adjusting the inductance ratio of two coils.

A Study On Verification Methodology On Railway Signalling System related to Fail Safe/ Fault Tolerant (철도신호의 Fail Safe/Fault Tolerant 시스템에 대한 검증방법에 대한 연구)

  • Lee, Jong-Woo;Joung, Eui-Jin;Hwang, Jong-Gyu;Shin, Duck-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1214-1219
    • /
    • 2002
  • Railway signalling system always is required high safety and reliability. The failure of the train control system can provoke a serious accident. In this paper, we show how to achieve the safety and reliability by dividing signalling system into vital and non functions, studying operational environment.

  • PDF

A Study on the S/W Reliability Comparison during Operational Stage (운영중 소프트웨어의 고장률에 의한 신뢰도 비교 연구)

  • Che Gyu-Shik;Moon Myung-Ho;Jeon In-Oh
    • Journal of Information Technology Applications and Management
    • /
    • v.13 no.2
    • /
    • pp.17-28
    • /
    • 2006
  • The SRGM has been studied under the assumption that S/W reliability can grow as the fault causing failure is removed even during operational phase because the debugging is available. On the other hand, some papers insist on the uniform failure rate during operational phase because the debugging may not be available in case of universal software. The phenomenon, however, has been observed informally many times that the products S/W reliability grows as the time goes by even without any debugging in point of customer view. I propose the simple approaching method to model the S/W reliability phenomenon that the failure rate reduces as time goes on without modifying the existing reliability model in this paper.

  • PDF

Web Service Application for Machine Tool Fault with Open Architecture CNC (개방형 CNC를 가지는 공작기계의 고장진단과 웹 서비스 기술)

  • 김동훈;김선호;윤원수;고광식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.121-124
    • /
    • 2003
  • The conventional CNC(Computerized Numerical Controller) of machine tool, which is dependent to CNC maker, was a closed architecture type. Therefore, it is impossible to implement a special user-define function to CNC. But recently, CNC is changed to OAC(Open Architecture Controller) type increasingly and the general function of CNC can be upgrade efficiently. This paper describes web service application for remote monitoring regarding the faults or machine tool with open architecture CNC. The major faults of CNC machine tool can be defined to the operational faults to be charged over 70%. Those faults are unpredictable because of being occurred without any warning. To generalize the fault diagnosis efficiently. two diagnosis models such as SF(Switching Function) and SSF(Step Switching Function) are proposed and the function of fault diagnosis is implemented to internal function of OAC. Also, to service remotely the faults of CNC machine tool. the suitable web environment is proposed and practical function is programmed to evaluate its operation on web.

  • PDF

The Simulation on the Design and the Characteristic of Shielded Inductive $High-T_c$ Superconducting Fault Current Limiter (차폐유도형 고온초전도 전류제한기의 설계 및 특성시뮬레이션)

  • Im, Seong-Hun;Choe, Myeong-Ho;Lee, Hyeon-Su;Han, Byeong-Seong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.3
    • /
    • pp.173-178
    • /
    • 1999
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter(FCL) were simulated and analyzed. After determining parameters fo design for superconducting tube, iron core and primary coil, simple power system composed of shielded inductive FCL was simulated by the numerical analysis. The currents flowing under the fault condition could be limited below 50 A successfully. It was suggested that as the important factors of operational characteristics, the turns of primary coil and size of iron core play a major role for whether the shielded inductive SCFCL operated as inductive type or resistive type FCL.

  • PDF

Study on a Self Diagnostic Monitoring System for an Air-Operated Valve: Development of a Fault Library

  • Chai Jangbom;Kim Yunchul;Kim Wooshik;Cho Hangduke
    • Nuclear Engineering and Technology
    • /
    • v.36 no.3
    • /
    • pp.210-218
    • /
    • 2004
  • In the interest of nuclear power plant safety, a self-diagnostic monitoring system (SDMS) is needed to monitor defects in safety-related components. An air-operated valve (AOV) is one of the components to be monitored since the failure of its operation could potentially have catastrophic consequences. In this paper, a model of the AOV is developed with the parameters that affect the operational characteristics. The model is useful for both understanding the operation and correlating parameters and defects. Various defects are introduced in the experiments to construct a fault library, which will be used in a pattern recognition approach. Finally, the validity of the fault library is examined.

Analysis on the Protective Coordination on Neutral Line of Main Transformer in Power Distribution Substation with Superconducting Fault Current Limiter (MTR 중성점 접지에 초전도 전류제한기 적용시 지락과전류계전기 동작 분석)

  • Kim, Jin-Seok;Lim, Sung-Hun;Moon, Jong-Fil;Kim, Jae-Chul;Hyun, Ok-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2089-2094
    • /
    • 2009
  • The fault current has increased due to growth of distributed generations for the large power demand in power distribution system. To solve some problem such as excess of the circuit breaker's cut-off ratings, the superconducting fault current limiter(SFCL) has been progressed. However, the operational characteristics of the relay is changed by SFCL. Therefore, the proper impedance for the SFCL should be selected to keep protective coordination with the SFCL when SFCL is introduced on the neutral line of main transformer in distribution system. In this paper, the proper normal conducting resistance was suggested to solve the problem in case of the protection coordination with SFCL.

Operational Characteristics of the High-speed Interrupter for Reliability Enhancement of Power Supply and Demand (전력수급의 신뢰도 확보를 위한 고속 인터럽터 동작 특성)

  • Choi, Hye-Won;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.143-148
    • /
    • 2013
  • When the fault occurs in power system, the fault-current exceeds breaking capacity of the circuit breaker. So, reliablity of the power system is decreased sharply. Superconducting fault-current limiter (SFCL) is operated without impedance in normal state. The fault-current is limited by its impedance during the fault condition. However, the SFCL has several weak points such as huge size, high-price, liquid-nitrogen operation for the real power system. In this paper, We suggested the high-speed interrupter to limit the fault-current in case of the single line-to-ground fault. In addition, we compared the high-speed interrupter with the SFCL to ensure the operation reliability. The proposed interrupter detected the fault-current through the CT, and the power was supplied by operation of the SCR control system. In this experiment, the power of high-speed interrupter was applied after the 4.8[msec] from fault instant. The on-off operation of the interrupter was started after half-cycle from the fault. The fault-current was flowed into the impedance element by the switching operation of the high-speed interrupter. So, the fault current was limited within one cycle, and then it didnt exceed the capacity of a circuit breaker. We confirmed that there was slight difference between the SFCL with high-speed interrupter in terms of limiting-time of the fault-current and switching speed of the SCR. The high-speed interrupter was considered to be more efficient than the SFCL in size, cost or reliability.

Test Method of an Embedded CMOS OP-AMP (내장된 CMOS 연산증폭기의 테스트 방법)

  • 김강철;송근호;한석붕
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.1
    • /
    • pp.100-105
    • /
    • 2003
  • In this paper, we propose the novel test method effectively to detect short and open faults in CMOS op-amp. The proposed method uses a sinusoidal signal with higher frequency than unit gain bandwidth. Since the proposed test method doesn't need complex algorithm to generate test pattern, the time of test pattern generation is short, and test cost is reduced because a single test pattern is able to detect all target faults. To verify the proposed method, CMOS two-stage operational amplifier with short and open faults is designed and the simulation results of HSPICE for the circuit have shown that the proposed test method can detect short and open faults in CMOS op-amp.