• Title/Summary/Keyword: Operational Control

Search Result 1,516, Processing Time 0.025 seconds

Semi-active Damping Control for Vibration Attenuation: Maximum Dissipation Direction Control

  • Kim, Jeong-Hoon;Lee, Chong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.229-234
    • /
    • 2001
  • A practical and effective semi-active on-off control law is developed for vibration attenuation of a natural, multi-degree-of-freedom suspension system, when its operational response mode is available. It does not need the accurate system parameters and dynamics of semi-active actuator. It reduces the total vibratory energy of the system including the work done by external disturbances and the maximum energy dissipation direction of the semi-active control device is tuned to the operational response mode of the structure. The effectiveness of the control law is illustrated with a three degree-of-freedom excavator cabin model.

  • PDF

Analytical design of constraint handling optimal two parameter internal model control for dead-time processes

  • Tchamna, Rodrigue;Qyyum, Muhammad Abdul;Zahoor, Muhammad;Kamga, Camille;Kwok, Ezra;Lee, Moonyong
    • Korean Journal of Chemical Engineering
    • /
    • v.36 no.3
    • /
    • pp.356-367
    • /
    • 2019
  • This work presents an advanced and systematic approach to analytically design the optimal parameters of a two parameter second-order internal model control (IMC) filter that satisfies operational constraints on the output process, the manipulated variable as well as rate of change of the manipulated variable, for a first-order plus dead time (FOPDT) process. The IMC parameters are designed to minimize a control objective function composed of the weighted sum of the error between the process variable and the set point, and the rate of change of the manipulated variable, and to satisfy the desired constraints. The feasible region of the constrained IMC control parameters was graphically analyzed, as the process parameters and the constraints varied. The resulting constrained IMC control parameters were also used to find the corresponding industrial proportional-integral controller parameters of a Smith predictor structure.

Korea's Free Economic Zone as an Economic Development Strategy and Operational System (경제발전전략으로서 한국의 경제자유구역과 운영체계에 관한 연구)

  • Koh, Eui-Hyeon
    • Journal of Distribution Science
    • /
    • v.12 no.9
    • /
    • pp.113-123
    • /
    • 2014
  • Purpose - After Korea's Free Economic Zone (FEZ) system was launched in 2003, there have been many debates about upgrading it and its support systems. However, as of 2013, there were insufficient results. Further, upon the designation of the East Coast and Chungbuk as official FEZs from February 4, 2013 by the 56th the Commission, there is a concern that many people are in the area designated as FEZ 8. This study investigates Korea's new FEZ system as part of Korea's primary new economic development policy in the 21st century. Therefore, this study examines views on the weaknesses of the past ten years of FEZs so that Korea can expand its FEZ system. Research design, data, and methodology -Many countries have considered the FEZ as an economic special zone. By reviewing previous research models, this study provides an update using recent data and materials, until 2013, from the Center of Free Economic Zones. In previous studies, the lack of support systems was attributed to proposals to ensure operational autonomy and differentiation of each FEZ; however, the main cause cannot be solved through regulatory issues, as difficulties caused by the operational system are responsible for the problems. We wish to analyze the FEZ, specifically the operational system; this is the main issue of this study. Results - After the first FEZs were established, it became necessary to have basic plans, as investment results in 2013 compared to the same period this year led to lower earnings in the first half of 2014. We propose an improvement of the operational system because in the free economic zones, the operational system is the root cause of the underlying problem. The results of this research are as follows. The weak management of the FEZ system is influenced by weak investment, delayed development, foreigners' living facilities, benefits of foreign investments, the control tower's policy making decision process, quickness of the process of satisfying legal requirements, and support For the independence of FEZs. Conclusion - Local governments do not have legal rights over FEZ deregulation and investment industries. This study suggests that the local government should have more independence from the central government. Moreover, independent management committees are more effective for ensuring public rights, better employee responsibilities, and better-qualified personnel. The FEZ committee struggles to effectively manage the locations of FEZs, foreign investments, and related facilities under the control of the Ministry of Trade, Industry and Energy. Thus, the FEZ committee should be under either the Prime Minister's office or the Presidential committee, to control and effectively coordinate between the local and central governments. If the problem clearly applies to the operational system in 2013, it is necessary to provide materials and methods so that the results of the first half of 2014 can be computed despite the data limits and lack of resources, and the data can be analyzed in a more diachronic thesis.

Operational Problems Expected in Interconnected Power Systems (연계된 계통에서 예상되는 문제점)

  • Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.122-125
    • /
    • 1992
  • Political situations of Korean Peninsula has been changing dramatically in recent years. Interconnected power system operation between South and North Korea should be taken into considerations. This paper discusses several expected operational problems in interconnected systems through literature study. Typical references in automatic generation control area are listed and recommended to read through.

  • PDF

Thermal Compensation Circuit with Improved Compensation Characteristic for Power Amplifier (개선된 보상특성을 갖는 증폭기용 온도보상회로)

  • Jung, Young-Bae
    • Journal of IKEEE
    • /
    • v.16 no.3
    • /
    • pp.177-181
    • /
    • 2012
  • This paper introduces a thermal compensation circuit with improved compensation characteristic for amplifiers to provide stable output power regardless environmental temperature. The proposed thermal compensation circuit is composed of two branchline couplers having two diodes between them. And, the thermistor whose resistance varies significantly with temperature inversely and a operational amplifiers, so called as OP-amp, control the diodes in the compensations circuit to realize more effective thermal compendation characteristic compared with conventional circuit.

Study on The Development of Basic Simulation Network for Operational Transient Analysis of The CANDU Power Plant

  • Park, Jong-Woon;Lim, Jae-cheon;Suh, Jae-seung;Chung, Ji-bum;Kim, Sung-Bae
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.423-428
    • /
    • 1995
  • Simulation models have been developed to predict the overall behavior of the CANDU plant systems during normal operational transients. For real time simulation purpose, simplified thermal hydraulic models are applied with appropriate system control logics, which include primary heat transport system solver with its component models and secondary side system models. The secondary side models are mainly used to provide boundary conditions for primary system calculation and to accomodate plant power control logics. Also, for the effective use of simulation package, hardware oriented basic simulation network has been established with appropriate graphic display system. Through validation with typical plant power maneuvering cases using proven plant performance analysis computer code, the present simulation package shows reasonable capability in the prediction of the dynamic behavior of plant variables during operational transients of CANDU plant, which means that this simulation tool can be utilized as a basic framework for full scope simulation network through further improvements.

  • PDF

Research on aging-related degradation of control rod drive system based on dynamic object-oriented Bayesian network and hidden Markov model

  • Kang Zhu;Xinwen Zhao;Liming Zhang;Hang Yu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4111-4124
    • /
    • 2022
  • The control rod drive system is critical to the reactor's reliable operation. The performance of its control system and mechanical system will gradually deteriorate because of operational and environmental stresses, thus increasing the reactor's operational risk. Currently there are few researches on the aging-related degradation of the entire control rod drive system. Because it is difficult to quantify the effect of various environmental stresses and establish an accurate physical model when multiple mechanisms superimposed in the degradation process. Therefore, this paper investigates the aging-related degradation of a control rod drive system by integrating Dynamic Object-Oriented Bayesian Network and Hidden Markov Model. Uncertainties in the degradation of the control system and mechanical system are addressed by using fuzzy theory and the Hidden Markov Model respectively. A system which consists of eight control rod drive mechanisms divided into two groups is used to demonstrate the method. The aging-related degradation of the control rod drive system is analyzed by the Bayesian inference algorithm based on the accelerated life test data, and the impact of different operating schemes on the system performance is also investigated. Meanwhile, the components or units that have major impact on the system's performance are identified at different operational phases. Finally, several essential safety measures are suggested to mitigate the risk caused by the system degradation.

A Development of the Operational Architecture of a Low Altitude Air Defense Automation System (저고도 방공자동화체계의 운용아키덱처 개발)

  • Son, Hyun-Sik;Kwon, Yong-Soo
    • Journal of the military operations research society of Korea
    • /
    • v.34 no.1
    • /
    • pp.31-45
    • /
    • 2008
  • This paper describes a development of the operational architecture of a low altitude air defense automation system using a systems engineering approach. The future battlefield is changing to new system of systems that command and control by the network based BM/C4I. Also, it is composed of various sensors and shooters in an single theater. Future threats may be characterized as unmanned mewing bodies that the strategic effect is great such as UAVs, cruise missiles or tactical ballistic missiles. New threats such as low altitude stealth cruise missiles may also appear. The implementation of a low altitude air defense against these future threats is required to complex and integrated approach based on systems engineering. In this view, this work established an operational scenario and derived operational requirements by identifying mission and future operational environments. It is presented the operational architecture of the low altitude air defense automation system by using the CORE 5.0.

Noise, vibration Characteristic Identification and Noise Control of Indoor Air-Conditioner's Cabinet using Operational Deflection Shape (운행 중 변형형상을 이용한 에어컨 실내기 캐비닛의 소음/진동 특성 파악 및 제어)

  • Lee, Seong-Jin;Oh, Jae-Eung;Lee, Jung-Youn;Kang, Tae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.830-833
    • /
    • 2004
  • An indoor package air-conditioner (PAC) has complex noise sources such as motor noise and fluid noise caused by the fan motor, heat transfer and shroud. Sound intensity techniques and ODS(Operational deflection shape) techniques are applied to identify the noise characteristics of an indoor air-conditioner's cabinet. The sound intensity is used to visualize the noise source locations. and the ODS to visualize the vibration pattern and to obtain the dynamic characteristics of the noise source. Acoustic intensity and operational deflection distribution are obtained in space domains as well as frequency domains. Using the visual information of source locations and its dynamic characteristics, the damping patch is applied to reduce structure borne noise in the cabinet. As a result, the noise emitted by the cabinet is reduced by 5dB.

  • PDF

How Through-Process Optimization (TPO) Assists to Meet Product Quality

  • Klaus Jax;Yuyou Zhai;Wolfgang Oberaigner
    • Corrosion Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.131-138
    • /
    • 2024
  • This paper introduces Primetals Technologies' Through-Process Optimization (TPO) Services and Through-Process Quality Control (TPQC) System, which integrate domain knowledge, software, and automation expertise to assist steel producers in achieving operational excellence. TPQC collects high-resolution process and product data from the entire production route, providing visualizations and facilitating quality assurance. It also enables the application of artificial intelligence techniques to optimize processes, accelerate steel grade development, and enhance product quality. The main objective of TPO is to grow and digitize operational know-how, increase profitability, and better meet customer needs. The paper describes the contribution of these systems to achieving operational excellence, with a focus on quality assurance. Transparent and traceable production data is used for manual and automatic quality evaluation, resulting in product quality status and guiding the product disposition process. Deviation management is supported by rule-based and AI-based assistants, along with monitoring, alarming, and reporting functions ensuring early recognition of deviations. Embedded root cause proposals and their corrective and compensatory actions facilitate decision support to maintain product quality. Quality indicators and predictive quality models further enhance the efficiency of the quality assurance process. Utilizing the quality assurance software package, TPQC acts as a "one-truth" platform for product quality key players.