• 제목/요약/키워드: Operation voltage

검색결과 3,665건 처리시간 0.029초

전압원 멀티레벨 컨버터 밸브 시험회로 연구 (Voltage source multilevel module converter valve test circuit research)

  • 원진;이진희;정택선;백승택
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.79-80
    • /
    • 2014
  • Voltage source multilevel module converter attracts more and more attention recently. The core component of the voltage source multilevel module converter is the valve based on IGBT. So the test circuit for the valve is very important, reliable test method can guarantee the converter valve design meet the operation requirement. This paper analyzes the valve voltage and current stress during the operation, and according to IEC standard test requirement, object, condition, introduces a kind of test circuit. Finally, through the simulation model, to verify the test circuit can provide the proper test condition for the voltage source multilevel module converter valve.

  • PDF

대용량 및 높은 입력전압에 적합한 새로운 Three Level DC/DC 컨버터 (A Novel Three Level DC/DC Converter for High power applications operating from High Input Voltage)

  • 한상규;오원식;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.317-322
    • /
    • 2003
  • A novel three-level DC/DC converter (TLC)for high power applications operating from high input voltage Is proposed. Its switch voltage stress can be ensured to be only one-half of the Input voltage. Nevertheless, since all input voltage is applied to the transformer primary side, it has good turns ratio. The driving method of each module is same as those of the conventional phase-shifted ZVS full bridge PWM converter (PSFB) and the zero-voltage-switching (ZVS) of the leading leg are achieved exactly in the same manner as that of the PSFB. Moreover, its three-level operation can considerably reduce the current ripple through the output inductor and it has no problems of the DC-link voltage unbalance. Therefore, it features a low voltage stress, high efficiency, low EMI, high power density, and small sized filter. To confirm the operation, validity, and features of the proposed circuit, experimental results from a 200W, 600V/DC-48V/DC prototype are presented.

  • PDF

제어 방식에 따른 20 W급 LED Converter 설계 및 분석 (Design and Analysis of 20 W Class LED Converter Considering Its Control Method)

  • 정영기;김성현;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제25권1호
    • /
    • pp.53-57
    • /
    • 2012
  • In this paper, by designing 20 W class driving circuit for driving high-power LED (Light Emitting Diode), we are going to comparatively carry out the analysis of characteristics for power circuit according to each design method. In this case, 200 V 60 Hz was performed as input data. The electrical characteristics such as voltage, current and ripple are checked for constant current circuit and constant voltage circuit in the LED module. In addition, as the ripple has an influence on illumination of LED light, low temperature working (-20 [$^{\circ}C$]) and high temperature working(80 [$^{\circ}C$]) are measured to make sure the ripple characteristics in accordance with temperature. In low temperature operation -20 [$^{\circ}C$] measurements, both constant current circuit and constant-voltage circuit were less impacted on input fluctuation, whereas in the high temperature operation 80 [$^{\circ}C$], current voltage in constant voltage circuit was surge after 430 [hour]. Voltage current ripple of constant current circuit was much less than constant voltage circuit, therefore we can show that constant current circuit is more stable.

국내 전력계통 신뢰도 기준을 위한 전압 제한범위 결정에 관한 연구 (A Study on the Determination of Voltage Limits for Korean Power System Reliability)

  • 벤지마플로레스;드위리아나아리아니;김승진;송화창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.335-336
    • /
    • 2015
  • Voltage collapse is one of the main threats in power system operation and it is a result of a very low voltage profile in one or multiple areas in the power system network. Hence, the need for proper coordination among transmission and generator operators to maintain voltage stability if of paramount importance. In this paper, the different voltage and reactive power operating guidelines and criteria of various electric reliability councils, coordinating councils, transmission system operators and other electric utilities are discussed. Among these are NERC, ENTSO-E, WECC, PJM and ERCOT. A comprehensive comparison is also made to the existing Korean power system voltage reliability guidelines. Furthermore, this paper presents a set of voltage and reactive power guidelines that can help in determining voltage limits that can improve the reliability of the Korean power system operation.

  • PDF

3상 4선식 저압 배전선로에서 선형 및 비선형 부하의 사용시 전압 불평형률 비교 분석 (Comparative Analysis of Voltage Unbalance Factor on the use of Linear and Non-linear loads in Three-phase Four-wire Low Voltage Distribution Line)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.587-592
    • /
    • 2017
  • In the three-phase four-wire low-voltage power distribution equipment, single-phase and three-phase load have been used mainly mixed. Also linear and nonlinear loads have been used together in the same conditions. In a three-phase four-wire distribution line, the current distribution of three-phase linear load is almost constant in each phase during driving or stopping, but the single-phase load is different from each other for each phase in accordance with the operation and stop. So that the voltage unbalance is caused by the current difference of each phase. In the three-phase four-wire distribution system, non-linear load is used with linear load. The presence of single-phase nonlinear loads can produce an increase in harmonic currents in three-phase and neutral line. It can also cause voltage unbalance. In the present study, we analyzed for the voltage unbalance fluctuations by the operation pattern of the single and three-phase linear and non-linear load in three-phase four-wire low voltage distribution system.

Chopper Controller Based DC Voltage Control Strategy for Cascaded Multilevel STATCOM

  • Xiong, Lian-Song;Zhuo, Fang
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.576-588
    • /
    • 2014
  • The superiority of CMI (Cascaded Multilevel Inverter) is unparalleled in high power and high voltage STATCOM (Static Synchronous Compensator). However, the parameters and operating conditions of each individual power unit composing the cascaded STATCOM differ from unit to unit, causing unit voltage disequilibrium on the DC side. This phenomenon seriously impairs the operation performance of STATCOM, and thus maintaining the DC voltage balance and stability becomes critical for cascaded STATCOM. This paper analyzes the case of voltage disequilibrium, combines the operation characteristics of the cascaded STATCOM, and proposes a new DC voltage control scheme with the advantages of good control performance and stability. This hierarchical control method uses software to achieve the total active power control and also uses chopper controllers to enable that the imbalance power can flow among the capacitors in order to keep DC capacitor voltages balance. The operating principle of the chopper controllers is analyzed and the implementation is presented. The major advantages of the proposed control strategy are that the number of PI regulators has been decreased remarkably and accordingly the blindness of system design and debugging also reduces obviously. The simulation reveals that the proposed control scheme can achieve the satisfactory control goals.

불평형 전압 동작시 전력 커패시터 특성 분석 (Characteristics Analysis of Power Capacitor with Unbalanced Voltage Operation)

  • 김종겸;박영진;이은웅
    • 조명전기설비학회논문지
    • /
    • 제22권5호
    • /
    • pp.64-72
    • /
    • 2008
  • 3상 4선식 전원공급에서 부하의 불평형 운전에 의한 전압 불평형은 전류 불평형을 일으켜 기기의 손실증가에 따른 출력 감소로 전원용량을 증가시키는 것은 물론이고 전기 품질에도 나쁜 영향을 미치고 있다. 전력용 커패시터는 유도성 부하의 역률 보상과 전원을 안정시키기 위해 사용되며, 유도전동기의 여자에 필요한 자화성분을 전원을 대신하여 제공하기도 한다. 전압 불평형이 지속될 경우 커패시터에 전압 스트레스로 작용하여 절연 고장을 일으킬 수 있다. 본 논문에서는 역률 개선용 커패시터가 전압 불평형 증가에 의해 받는 영향을 해석한 결과 전압 및 전류의 크기가 함께 증가하여 스트레스는 점차적으로 높아진다는 것을 확인할 수 있었다.

축소모형을 이용한 MMC의 Redundancy Module 동작분석 (Redundancy Module Operation Analysis of MMC using Scaled Hardware Model)

  • 유승환;신은석;최종윤;한병문
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1046-1054
    • /
    • 2014
  • In this paper, a hardware prototype for the 10kVA 11-level MMC was built and various experimental works were conducted to verify the operation algorithms of MMC. The hardware prototype was designed using computer simulation with PSCAD/EMTDC software. After manufactured in the lab, the hardware prototype was tested to verify the modulation algorithms to form the output voltage, the balancing algorithm to equalize the sub-module capacitor voltage, and the redundancy operation algorithm to improve the system reliability. The developed hardware prototype can be utilized for analyzing the basic operation and performance improvement of MMC according to the modulation and redundancy operation scheme. It also can be utilize to analyze the basic operational characteristics of HVDC system based on MMC.

동기 정류기를 이용한 태양광 모듈용 플라이백 인버터 소프트 스위칭 제어 기법 (Soft Switching Control Method for Photovoltaic AC Module Flyback Inverter using Synchronous Rectifier)

  • 장진우;김영호;최봉연;정용채;원충연
    • 전력전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.312-321
    • /
    • 2013
  • In this paper, high efficiency control method for flyback inverter with synchronous rectifier(SR) based on photovoltaic AC modules is proposed. In this control method, the operation of SR is classified according to the voltage spike across main switch SP. When the voltage spike across SP is lower than the rating voltage of SP, the operation of active clamp circuit is interrupted for reducing the switching loss of auxiliary switch. In this time, the SR is operated for soft-switching of SP. When the voltage spike across Sp is higher than the rating voltage of SP, the operation of active circuit is activated for reducing the voltage spike. The SR is operated for reducing the conduction loss of secondary output diode. Thus, a switching loss of the main switch can be reduced in low power region, and weighted-efficiency can be improved. A theoretical analysis and the design principle of the proposed method are provided. And validity is confirmed through simulation and experimental results.

모터 파라미터 산포를 고려한 고속 운전에서의 속도제한 제어기 구현 (Implementation of Speed Limitation Controller Considering Motor Parameter Variation in High Speed Operation)

  • 김경훈;윤철;권우현
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1584-1590
    • /
    • 2017
  • This paper presents a implementation method of reliable speed limitation controller considering motor parameter variation in high speed operation. In spinning process of drum washing machine, speed increase has to be limited when unallowable imbalance mass is detected. Otherwise, severe noise and vibration can happen because noise and vibration are proportional to imbalance mass. To detect imbalance mass, d-axis current magnitude is used. However, we have to compensate for back-emf and power supply variation by means of detecting them because d-axis current is affected by both of them. On the other hand, we have to carefully estimate back-emf because back-emf is affected by stator resistance variation and inverter voltage error. Stator resistance variation can happen by manufacturing process for mass production or temperature variation in running. And there are inverter voltage errors between command voltage from micro-computer to inverter and real voltage from inverter to motor because of rising and falling time delay and turn-on resistance of power semiconductor switch. To solve this problem, we propose 2-step align current injection method which is to inject step-wise current right before starting. By this method, we can simply obtain stator resistance by ratio of voltage without inverter voltage error and current, and we can measure inverter voltage error. So we can obtain more exact model current, and then by simple calculation with compensation gain, we can estimate more accurate motor back-emf. We show that this method works well. It is verified through experiments.