• Title/Summary/Keyword: Operation technique

Search Result 3,223, Processing Time 0.044 seconds

Early and mid-term results of pulmonary valve reconstruction in surgical repair of tetralogy of Fallot; comparison with other techniques of right ventricular outflow reconstruction (활로사징 완전교정술에서 폐동맥 판막 재건술의 조기 및 중기 결과; 우심실 유출로 재건 방법에 따른 비교)

  • Wang, Sheng Wen;Lee, Young Seok;Kim, Si Ho;Kim, Tae Hong;Ban, Ji Eun;Lee, Hyoung Doo;Chang, Yun Hee;Sung, Si Chan
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.6
    • /
    • pp.635-642
    • /
    • 2006
  • Purpose : The purpose of this study is to determine whether the new pulmonary valve reconstruction technique prevents short-term postoperative pulmonary regurgitation and improves early and mid-term clinical outcome. Methods : We reviewed postoperative echocardiographic variables and chest X-ray films from 31 patients who had undergone valve reconstruction(pulmonary valve reconstruction group : PVR) for the repair of TOF between April 2000 and August 2004. We compared the clinical data of these patients with those from 47 patients who had right ventricular outflow tract reconstruction with a monocusp valve(monocusp ventricular outflow patch group : MVOP) and 22 patients who had a transannular patch repair without a monocusp valve(transannular patch group : TAP). Results : In the PVR group, 25 patients(81 percent) had trivial or mild pulmonary regurgitation in their early post operative echocardiogram. Only 12 patients(26 percent) in the MVOP group had mild pulmonary regurgitation; and no patient in the TAP group had it. Pulmonary valve function was good in 96 percent of the PVR group, 36 percent of the MVOP group, and none in the TAP group in early post-operative echocardiogram. Follow-up echocardiogram(1, 2, 3, 4 years later) of the MVOP and TAP groups showed moderate pulmonary regurgitation and severely decreased valve function in almost all cases. However, in the PVR group 54 percent(16/28), 50 percent(14/28), 37 percent(9/24), and 31 percent(5/16) of the patients had trivial or mild pulmonary regurgitation 1, 2, 3 and 4 years after operation, respectively. The valve function remained good in 80 percent(24/30), 64 percent(18/28), 57 percent(12/21), and 31 percent(5/16) of the patients 1, 2, 3 and 4 years after operation respectively. Conclusion : Pulmonary valve reconstruction is effective in reducing pulmonary regurgitation and right ventricular dilatation in the repair of TOF, even though regurgitation increases with time. Further study is needed to determine long-term results.

Camparison between the 1 Day and the 2 Day Protocols of Lymphoscintigraphy and Sentinel Node Biopsy using Subareolar Injection in Breast Cancer Patients: A Retrospective Study (유륜하 주사에 의한 유방암 환자의 전초림프절 스캔과 전초림프절 생검에 있어서 당일검사와 전날검사의 비교: 후향적 연구)

  • Seok, Ju-Won;Jun, Sung-Min;Nam, Hyun-Yeol;Kim, In-Ju
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.55-59
    • /
    • 2009
  • Purpose: Lymphoscintigraphy and sentinel node biopsy are used in detection of axillary lymph node metastasis in breast cancer patients, but standardized technique is not established. We compared the results of the injection the morning of surgery (1 day protocol) with the subareolar injection the day before surgery (2 day protocol) with the subareolar injection in patients with breast cancer having lymphoscintigraphy and sentinel node biopsy. Materials and Methods: This study included 349 patients who underwent the breast cancer operation during 2001-2004. One hundred seventy one patients (1 day protocol, 1 hour) was injected 0.8ml of Tc-99m Tin-Colloid (37 MBq) by subareolar injection on the morning of surgery. One hundred seventy eight patients (2 day protocol, 16 hour) was injected 0.8 ml of T c-99m Tin-Colloid (185 MBq) on the afternoon before surgery. Lymphoscintigraphy was performed in sitting position and sentinel node localization was performed by hand-held gamma probe during operation. Result: In the 1 day protocol, 153 cases (89.5%) of the sentinel node were localized by lymphoscintigraphy and 150 cases (87.7%) were localized by gamma probe. In the 2 day protocol, 159 cases (89.3%) were localized by lymphoscintigraphy and 154 cases (86.5%) were localized by gamma probe. There was no significant difference in localization of sentinel node between the 1 day and the 2 day protocol by lymphoscintigraphy and gamma probe (p>0.05, p>0.05). Conclusion: There was no difference the result of localization of sentinel node with subareolar injection between the 1 day and the 2 day protocol in breast cancer patients. Because the 2 day protocol allows the enough time of performing lymphoscintigraphy, it is more useful in localization of sentinel node in breast cancer patients.

Bivalvation Valvuloplasty for Common Atrioventricular Valve Regurgitation in Functional Single Ventricle; Early and Mid-term Results (기능적 단심설에서 공통방실판 역류의 판막성형술; 판막 이분성형술(bivalvation)의 조기 및 중기 결과)

  • Chang, Yun-Hee;Sung, Si-Chan;Kim, Seon-Hee;Lee, Hyoung-Doo;Ban, Ji-Eun
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.597-603
    • /
    • 2009
  • Background: Atrioventricular valve regurgitation in pediatric patients with a functional single ventricles (FSV) - has been known as one of the important risk factors for death and unfavorable long-term results after a Fontan operation. We evaluated early and mid-term results of bivalvation valvuloplasty in FSV patients. Material and Method: We retrospectively evaluated 11 patients with a functional single ventricle who underwent bivalvationvalvuloplasty between 1999 and 2007. The degree of common atrioventricular valve regurgitation (CAVVR) was determined by color Doppler echocardiography (regurgitation grade scoring, trivial; 1, mild; 2, moderate; 3, severe; 4). Mean age at valve surgery was $6.9{\pm}7.0$ months (median 4 months, 24 days$\sim$21 months)and mean body weight was $6.2{\pm}2.8\;kg$ ($3.1{\sim}11.3\;kg$). Nine patients had isomerism heart and two of them had TAPVC. The concomitant procedures were performed in all but one patient. Additional commissural closure was performed in 3 patients and commissural annuloplasty in another 3 patients. Result: There was one hospital death after. surgery. A 32-day old patient who had been preoperatively dependent on a ventilator died of air way and lung problems 4.3 months after pulmonary artery banding and bivalvation valvuloplasty. Mean follow-up duration was 40 months ($4.3{\sim}114$ months). Mean preoperative CAVVR score was $3.3{\pm}0.6$, which decreased to $1.9{\pm}0.7$ postoperatively (p<0.0001). This residual regurgitation slightly increased to $2.2{\pm}0.4$ (no statistical significance) after a mean follow-up of 1.4.3 months. Six patients (60%) required re-operations for residual regurgitation at a subsequent bidirectionalcavopulmonary shunt or Fontan operation. One patient with Ebsteinoid malformation of the right sided atrioventricular valve required valve replacement due to stenoinsufficiency. Another patient required edge-to-edge repair at the right sided AV valve (between the right mural leaflet and the bridging leaflets). The remaining 4 patients required additional suture placements between bridging leaflets with or without commissural annuloplasty. All survivor had trivial or mild CAVVR at the latest follow-up. Conclusion: Bivalvation valvuloplasty for CAVVR in FSV patients is. an effective and safe procedure. However, significant numbers of the patients have small residual regurgitation and require additional valve procedures at subsequent operations. Long-term observations to monitor progression of the CAVVR is mandatory.

Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures (AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과)

  • Kim, Young-Mo;Lee, June-Kyu;Yang, Jae-Hoon;Kim, Bo-Kun;Lee, Won-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Purpose: To evaluate the usefulness of minimally invasive arthroscopy-assisted plate removal of a laterally inserted periarticular distal femur plate used for the treatment of AO type-C distal femur fractures. Materials and Methods: From October 2002 to November 2005, we evaluated 17 patients whose plates were removed through minimally invasive arthroscopy-assisted plate-removal technique and 15 patients who got their plates removed through conventional method without using arthroscopy, 32 patients in total. All these patients included in this study initially underwent open reduction and internal fixation of the distal femoral fractures with a lateral plate, and complained of continued pain over the lateral femoral condyle after the fracture fixation. The average age was 42.6 (ranges: 20~66) and initial fracture types included 16 cases of C1, 11 cases of C2, and 5 cases of C3 following AO/ASIF classification guidelines. Measured outcomes included: associated intra-articular pathologies, time needed to return to activities of daily living, patients' overall satisfaction, complications following the removal of hardware, and pain before and 6 months after the operation. Results: The distal-most end of the plate was placed in the knee joint in all cases and damage of the lateral articular capsule was found in 23 cases. Continuous wound discharge after surgery was found in one case who underwent arthroscopy-assisted plate removal, and it was treated by irrigation and re-suture. Average time needed to return to activities of daily living was 7 days in arthroscopy assisted group and 7.6 days in conventionally removed group. Fourteen patients (82.4%) who underwent arthroscopyassisted plate-removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 4.9 to 1.9, six months after the plate removal. Thirteen patients(86.7%) who underwent conventional plate removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 5.2 to 2.5, six months after the operation. Conclusion: Through minimally invasive arthroscopic-assisted plate removal, intrarticular pathology of the knee joint was able to be simultaneously identified and treated at the time of hardware removal. Damage of lateral capsule of the knee joint caused by the inserted plate for the treatment of type C distal femoral fracture was very frequently found and following the plate removal, patients experienced an improvement in pain score. We therefore recommend routine lateral distal femoral plate removal if the bony union is attained in such cases as type C distal femoral fractures whose distal most end of the plates are located in the joint.

  • PDF

Use of Undiluted Potassium Solution in Intermittent Antegrade Warm Blood Cardioplegia (IAWBC) (간헐적 전방온혈심정지액에서 희석되지 않은 고농도 포타슘의 사용)

  • 백완기;손국희;김영삼;윤용한;김혜숙;임현경;이춘수;김광호;김정택
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.660-664
    • /
    • 2004
  • Background: Dilution of blood cardioplegia is not needed in IAWBC as it is in cold blood cardioplegia because it does not aggregate red blood cells on normal body temperature and does not compromise micro coronary circulation. This study was designed to evaluate the safety and efficacy of undiluted potassium solution in IAWBC. Material and Method: Thirty patients who underwent CABG with IAWBC were grouped into dilutedplegia (n=14) and microplegia (n=16). Potassium was delivered conventionally with 4 : 1 delivery kit in the dilutedplegia group. The undiluted potassium was directly connected on the blood of oxygenator in the microplegia group. Result: There were no differences in sex, age, left ventricular ejection fraction, number of grafts, aortic cross clamping time, and the value of perioperative myocardial enzyme between the two groups. There were no perioperative myocardial infarction and hospital mortality. The amount of crystalloid cardioplegia was 1346$\pm$597 mL in dilutedplegia (mean$\pm$standard deviation, and 28$\pm$9 mL in microplegia (p<0.0001). The hematocrit during cardiopulmonary bypass was 21$\pm$4% in dilutedplegia and 24$\pm$3% in microplegia (p>0.05). 11 patients in dilultedplegia received blood transfusion, but 4 patients in microplegia received blood transfusion (p<0.05). The amount of urine and hemofiltration during the operation were more in dilutedplegia (1250$\pm$810 mL, 1689$\pm$548 mL) than in microplegia (959$\pm$410 mL, 1461$\pm$784 mL; p<0.05). Conclusion: The undiluted potassium of IAWBC in CABG operation is a safe, effective technique for myocardial protection to prevent fluid overload, and blood transfusion. There is no need to use the delivery kit.

The Preference Analysis of Forest Therapy Program with regard to MBTI Personality Types (MBTI 성격유형에 따른 산림치유 프로그램 선호도에 관한 연구)

  • Kim, Youn-Hee;Kim, Dong-Jun;Kim, Eun-Jin;Yeoun, Pyung-Sik;Choi, Byung-Jin;Kim, Jea-Kean;Kim, Youn-Soo
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.3
    • /
    • pp.485-498
    • /
    • 2015
  • The need for forest therapy programs has been increasing. For more effective forest healing, it is necessary to identify the characteristics of participants and develop and operate more targeted and differentiated forest therapy programs accordingly. In this study, the relationships between MBTI (Myers-Briggs Type Indicator) personality types and the relationship between the temperaments of MBTI and the preference for the forest therapy programs were analyzed respectively in pursuit of the basic data required for the effective development and operation of forest healing on the basis of individual characteristics. The survey on the forest therapy program and MBTI personality tests were conducted for 245 normal adults. Using the SPSS 21.0 program analysis, data were analyzed by Analysis of variance (ANOVA) to obtain the difference of preference on the forest therapy program according to the personality type. The Extraversion(E)-Introversion(I) types showed differences in technique-based breathing exercises, walking in the forest(wearing shoes), laughter therapy in the forest, viewing the forest, forest bathing, wind bathing and sun bathing. And the Sensing(S)-iNtuition (N) types had marked differences in listening to the sound of water flowing, drinking herbal tea and sleeping in the forest. The Thinking (T) -Feeling (F) types marked differences in soaking hands and feet in water and sleeping in the forest. The Judging (J)-Perceiving (P) types had differences in vision quest and viewing the forest, respectively, in statistics. Depending on the temperament of the character, there were statistically significant differences in preferences such as drinking herbal tea, eating natural food, sleeping in the forest, viewing the forest and listening to the forest commentary. The results of this study are expected to be used as a basis for forest healing program development and operation.

Hardware Approach to Fuzzy Inference―ASIC and RISC―

  • Watanabe, Hiroyuki
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.975-976
    • /
    • 1993
  • This talk presents the overview of the author's research and development activities on fuzzy inference hardware. We involved it with two distinct approaches. The first approach is to use application specific integrated circuits (ASIC) technology. The fuzzy inference method is directly implemented in silicon. The second approach, which is in its preliminary stage, is to use more conventional microprocessor architecture. Here, we use a quantitative technique used by designer of reduced instruction set computer (RISC) to modify an architecture of a microprocessor. In the ASIC approach, we implemented the most widely used fuzzy inference mechanism directly on silicon. The mechanism is beaded on a max-min compositional rule of inference, and Mandami's method of fuzzy implication. The two VLSI fuzzy inference chips are designed, fabricated, and fully tested. Both used a full-custom CMOS technology. The second and more claborate chip was designed at the University of North Carolina(U C) in cooperation with MCNC. Both VLSI chips had muliple datapaths for rule digital fuzzy inference chips had multiple datapaths for rule evaluation, and they executed multiple fuzzy if-then rules in parallel. The AT & T chip is the first digital fuzzy inference chip in the world. It ran with a 20 MHz clock cycle and achieved an approximately 80.000 Fuzzy Logical inferences Per Second (FLIPS). It stored and executed 16 fuzzy if-then rules. Since it was designed as a proof of concept prototype chip, it had minimal amount of peripheral logic for system integration. UNC/MCNC chip consists of 688,131 transistors of which 476,160 are used for RAM memory. It ran with a 10 MHz clock cycle. The chip has a 3-staged pipeline and initiates a computation of new inference every 64 cycle. This chip achieved an approximately 160,000 FLIPS. The new architecture have the following important improvements from the AT & T chip: Programmable rule set memory (RAM). On-chip fuzzification operation by a table lookup method. On-chip defuzzification operation by a centroid method. Reconfigurable architecture for processing two rule formats. RAM/datapath redundancy for higher yield It can store and execute 51 if-then rule of the following format: IF A and B and C and D Then Do E, and Then Do F. With this format, the chip takes four inputs and produces two outputs. By software reconfiguration, it can store and execute 102 if-then rules of the following simpler format using the same datapath: IF A and B Then Do E. With this format the chip takes two inputs and produces one outputs. We have built two VME-bus board systems based on this chip for Oak Ridge National Laboratory (ORNL). The board is now installed in a robot at ORNL. Researchers uses this board for experiment in autonomous robot navigation. The Fuzzy Logic system board places the Fuzzy chip into a VMEbus environment. High level C language functions hide the operational details of the board from the applications programme . The programmer treats rule memories and fuzzification function memories as local structures passed as parameters to the C functions. ASIC fuzzy inference hardware is extremely fast, but they are limited in generality. Many aspects of the design are limited or fixed. We have proposed to designing a are limited or fixed. We have proposed to designing a fuzzy information processor as an application specific processor using a quantitative approach. The quantitative approach was developed by RISC designers. In effect, we are interested in evaluating the effectiveness of a specialized RISC processor for fuzzy information processing. As the first step, we measured the possible speed-up of a fuzzy inference program based on if-then rules by an introduction of specialized instructions, i.e., min and max instructions. The minimum and maximum operations are heavily used in fuzzy logic applications as fuzzy intersection and union. We performed measurements using a MIPS R3000 as a base micropro essor. The initial result is encouraging. We can achieve as high as a 2.5 increase in inference speed if the R3000 had min and max instructions. Also, they are useful for speeding up other fuzzy operations such as bounded product and bounded sum. The embedded processor's main task is to control some device or process. It usually runs a single or a embedded processer to create an embedded processor for fuzzy control is very effective. Table I shows the measured speed of the inference by a MIPS R3000 microprocessor, a fictitious MIPS R3000 microprocessor with min and max instructions, and a UNC/MCNC ASIC fuzzy inference chip. The software that used on microprocessors is a simulator of the ASIC chip. The first row is the computation time in seconds of 6000 inferences using 51 rules where each fuzzy set is represented by an array of 64 elements. The second row is the time required to perform a single inference. The last row is the fuzzy logical inferences per second (FLIPS) measured for ach device. There is a large gap in run time between the ASIC and software approaches even if we resort to a specialized fuzzy microprocessor. As for design time and cost, these two approaches represent two extremes. An ASIC approach is extremely expensive. It is, therefore, an important research topic to design a specialized computing architecture for fuzzy applications that falls between these two extremes both in run time and design time/cost. TABLEI INFERENCE TIME BY 51 RULES {{{{Time }}{{MIPS R3000 }}{{ASIC }}{{Regular }}{{With min/mix }}{{6000 inference 1 inference FLIPS }}{{125s 20.8ms 48 }}{{49s 8.2ms 122 }}{{0.0038s 6.4㎲ 156,250 }} }}

  • PDF

Separation and Recovery of $SF_6$ Gas from $N_2/SF_6$ Gas Mixtures by using a Polymer Hollow Fiber Membranes (고분자 중공사 분리막을 이용한 $N_2/SF_6$ 혼합가스로부터 $SF_6$의 분리 및 회수)

  • Lee, Hyun-Jung;Lee, Min-Woo;Lee, Hyun-Kyung;Lee, Sang-Hyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.47-53
    • /
    • 2011
  • $SF_6$ (Sulfur hexafluoride) possesses high GWP (Global Warming Potential) as sepcified by the IPCC (Intergonvernmental Panel of Climate Change). Recently, the recovery-separtion of $SF_6$ research area, including permeation properties studies using various membrane's materials and the practical operation of recovery-separtion using membrane of waste $SF_6$ gas is in the initial state. The separation efficiency of a single $SF_6$ and waste $SF_6$ mixture was evaluated using a PSF (polysulfone), PC (tetra-bromo polycarbonate) and PI (polyimide) hollow fiber membranes. According to the results of single gases permeation properties, PI membrane has the highest permselectivity of $N_2$ gas in $N_2/SF_6$ gas. Under the condition of P=0.5 MPa, the highest concentration of recovered $SF_6$ is 95.6 vol % in the separation experiment of $SF_6/N_2$ mixture gas by PC membrane. Under the operation pressure of P=0.3 MPa at a fixed retentate flow rate fixed of 150 cc/min, the maximum recovery efficiency of $SF_6$ is up to 97.8% by PSF membrane. From the results above, it is thought that the separation and recovery technique of $SF_6$ gas using membrane will be used as the representative eco-technology in the $SF_6$ gas treatment in the future.

Minimally invasive cardiac surgery with the partial mini-sternotomy in children (소아연령군에서의 부분흉골소절개를 통한 최소침투적심장수술)

  • 이정렬;임홍국;성숙환;김용진;노준량;서경필
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.466-471
    • /
    • 1998
  • Purpose: The safety and efficacy of minimally invasive techniques in congenital heart surgery were tested in this study. Materal and method: Between July 1997 and November 1997, a total of 46 children were underwent minimally invasive cardiac operations at Seoul National University Children's Hospital. Age and body weight of the patients averaged 34.6${\pm}$41.8 (Range: 1∼148) months and 14.5${\pm}$9.9(Range: 3.0∼40.0) kg, respectively. Twenty eight patients were male. Preoperative surgical indications included 15 atrial septal defects, 25 ventricular septal defects, 1 foreign body in aorta, 3 partial atrioventricular septal defects, 1 total anomalous pulmonary venous connection(cardiac type), and 1 tetralogy of Fallot. After creating a small lower midline skin incision starting as down as possible from the sternal notch, a vertical midline sternotomy extended from xyphoid process to the level of the second intercostal space, where one of the T-, J-, I- or inverted C-shaped lower lying mini-sternotomy was completed with a creation of unilateral right or bilateral trap door sternal opening. A conventional direct aortic and bicaval cannulation was routine. Result: A mean length of skin incision was 6.1${\pm}$1.0(range: 4.0∼9.0) cm. A mean distance between the suprasternal notch and the upper most point of the skin incision was 4.0${\pm}$1.1 (range: 2.0∼7.0) cm. Mean cardiopulmonary bypass time, aortic cross-clamp time, and the operation time were 62.9${\pm}$20.0(range: 28∼147), 29.8${\pm}$12.8(range: 11∼79), and 161.1${\pm}$34.5 (range: 100-250) minutes. A mean total amount of postoperative blood transfusion was 71.0${\pm}$68.1 (range: 0∼267) cc. All patients were extubated mean 11.3${\pm}$13.8(range: 1∼73) hours after operation. A mean total amount of analgesics used was 0.8${\pm}$1.8(range: 0∼9) mg of morphine. The mean duration of stay in intensive care unit and hospital stay were 35.0${\pm}$32.2 (range: 10∼194) hours and 6.2${\pm}$2.0(range: 3∼11) days. There were no wound complications and hospital deaths. Conclusion: This short-term experience disclosed that the minimally invasive technique can be feasibly applied in a selected group of congenital heart disease as well as is cosmetically more attractive approach.

  • PDF

Coronary Artery Bypass Graft in Patient with Advanced Left Ventricular Dysfunction (중등도 이상의 좌심실 기능 부전 환자에서의 관상동 우회술의 임상 분석)

  • 정종필;김승우;신제균
    • Journal of Chest Surgery
    • /
    • v.34 no.12
    • /
    • pp.901-908
    • /
    • 2001
  • Background : Coronary artery bypass graft(CABG) in patients with advanced left ventricular dysfunction has often been regarded as having high mortality rate, despite the great improvement in operative result of CABG. With recent advances in surgical technique and myocardial protection, surgical revascularization improved the symptom and long-term survival of these high risk patients more than the medical conservative treatment. Material and Methold : Clinical data of 31(4.1%) patients with preoperative ejection fraction less than 30% among 864 CABGs performed between January 1995 and March 1999 were retrospectively analyzed and pre- and postoperative changes of the ejection fraction on echocardiography were analyzed. There were 26 men and 5 women. The mean age was 60.7 years(range 41 to 72 years). History of myocardial infarction(30 cases, 98%) was the most common preoperative risk factor. There were seven irreversible myocardial infarction on thallium scan. Most patients had triple vessel diseases(26 cases, 84%) and first degree of Rentrop classification(16 cases, 52%) on coronary angiography. The mean number of distal anastomosis during CABG was per patient was 4.9${\pm}$0.8 sites in each patient. In addition to long saphenous veins, the internal mammary artery was used in 20 patients. Total bypass time was 244.7${\pm}$3.7 minutes(range, 117 to 567 minutes), and mean aortic cross-clamp time was 77.9 ${\pm}$ 1.6 minutes(range, 30 to 178 minutes). There were five other reparative procedures such as two left ventricular aneurysrmectomy, two mitral repair, and one aortic valve replacement. There were twelve postoperative complications such as three cardiac arrhythmia, two bleeding(re-operation), one delayed sternal closure, eleven usage of intra-aortic balloon counterpulsation for low cardiac output. Two patients died, postoperative mortality was 6.5% . Twenty-nine patients were relieved of chest pain and left ventricular ejection fraction after operation was significantly higher(38.5${\pm}$11.6%, p 0.001) as compared with preoperative left ventricular ejection fraction(25.3${\pm}$2.3%). The follow up period of out patient was 25. 3 months. Conclusion: In patients with coronary artery disease and advanced left ventricular dysfunction, coronary artery bypass grafting can be performed relatively safely with improvement in left ventricular function, but it will be necessary to study long term results.

  • PDF