A Basic Planning of CMDSS(Centralized Maintenance Decision Support System) (CMDSS의 기초 설계)

  • 김태호;조영현;김현우
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1986.10a
    • /
    • pp.59-63
    • /
    • 1986
  • This paper presents a basic planning of CMDSS(Centrallized Maintenance Decision Support System)for future operation and maintenance of telecommunication network, the main components of CMDSS are MDB, MMB, DSDB, MDBMS, MMAMS, and IGMS. ANd the efficiency and the effectiveness depend on the adequate design of the decision procedure to assisy operation and maintenance persinnels.

  • PDF

An Implementation of Digital Neural Network Using Systolic Array Processor (영어 수계를 이용한 디지털 신경망회로의 실현)

  • 윤현식;조원경
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.2
    • /
    • pp.44-50
    • /
    • 1993
  • In this paper, we will present an array processor for implementation of digital neural networks. Back-propagation model can be formulated as a consecutive matrix-vector multiplication problem with some prespecified thresholding operation. This operation procedure is suited for the design of an array processor, because it can be recursively and repeatedly executed. Systolic array circuit architecture with Residue Number System is suggested to realize the efficient arithmetic circuit for matrix-vector multiplication and compute sigmoid function. The proposed design method would expect to adopt for the application field of neural networks, because it can be realized to currently developed VLSI technology.

  • PDF

A Construction Theory of Arithmetic Operation Unit Systems over $GF(2^m)$ ($GF(2^m)$ 상의 산술연산기시스템 구성 이론)

  • 박춘명;김흥수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.6
    • /
    • pp.910-920
    • /
    • 1990
  • This paper presents a method of constructing an Arithmetic Operation Unit Systems (A.O.U.S.) over Galois Field GF(2**m) for the purpose of the four arithmetical operation(addition, subtraction, multiplication and division between two elements in GF(2**mm). The proposed A.O.U.S. is constructed by following procedure. First of all, we obtained each four arithmetical operation algorithms for performing the four arithmetical operations using by mathematical properties over GF(2**m). Next, for the purpose of realizing the four arithmetical unit module (adder module, subtracter module, multiplier module and divider module), we constructed basic cells using the four arithmetical operation algorithms. Then, we realized the four Arithmetical Operation Unit Modules(A.O.U.M.) using basic cells and we constructd distributor modules for the purpose of merging A.O.U.M. with distributor modules. Finally, we constructed the A.O.U.S. over GF(2**m) by synthesizing A.O.U.M. with distributor modules. We prospect that we are able to construct an Arithmetic & Logical Operation Unit Systems (A.L.O.U.S.) if we will merge the proposed A.O.U.S. in this paper with Logical Operation Unit Systems (L.O.U.S.).

  • PDF

An Analysis of Nursing Work of Operating Room Nurses (수술실 간호사의 간호업무 분석)

  • Kwon, Sung-Bok;Park, Young-Sook;Kim, Dong-Oak;Yi, Yeo-Jin;Lee, Eun-Hee;Cho, Kyung-Sook
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.14 no.1
    • /
    • pp.72-84
    • /
    • 2008
  • Purpose: The purpose of this study was to identify nurses' duties and tasks for job analysis of the nurses in the operating room. Methods: This study was descriptive investigation research using the 3-point likert scale questionnaires and the level of importance, difficulty and the frequency of each duty and task were analyzed. Data were collected by 422 OR nurses from 57 hospitals. Results: Job of OR nurses included 13 duties and 105 tasks. The 13 duties were 'management of operative patient' 'assistive work for operation' 'supportive work for operation' 'infection control in OR' 'management of equipments and instruments for operation' 'administrating medicine for operation' 'supplies management for operation' 'safety management for operation' 'environmental management for operating room' 'administrative work for operation' 'education for operating room personnel' 'development of operation procedure books' and 'elf development of OR personnel' Conclusion: This study identified duties and tasks performed by OR nurses. Based on these results, the importance, frequency, and difficulty in this study will provide research evidence for developing training programs for OR nurses.

  • PDF

A Study on the Development of Safety Operation Guideline for Onboard A-Frame System Using Dynamic Simulation (동역학 시뮬레이션 기반 선박 A-Frame의 안전 운용 가이드 개발 연구)

  • Oh, Jae-Won;Kim, Hyung-Woo;Kwon, O-Soon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.5
    • /
    • pp.625-633
    • /
    • 2021
  • This paper considers the development of safety operation guideline for onboard A-Frame system used to operate heavy-work ROV using dynamic simulation. Onboard A-Frame is affected by ship's behavior and large inertia by the marine environment. For this reason, safety operation guidelines are required for the safety of workers who operate ship-mounted equipment. In order to develop a guideline, it is necessary to evaluate the safety loads through real sea experiment. However, simulation method is used instead since it is difficult to conduct experiments in sea. Therefore, a procedure for safety operation analysis based on dynamic simulation that can consider ship behavior and marine environment and a safety operation table were proposed in this study. And the construction of safety operation table and guide for safety operation using the applied load and safety factor analysis results were considered.

Limitations and improvement of the in situ measurements of ground thermal conductivity in Korea (국내 지중열전도도 측정 방법의 한계 및 개선 방향)

  • Shim, Byoung Ohan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.195.2-195.2
    • /
    • 2011
  • The borehole heat exchanger of Geothermal Heat Pump (GHP) system should be sustainable and cost effective for long term operation. To guaranty the performance of the system thermal Response Tests (TRTs) with simple recommended procedures have been applied in many countries. Korea government developed a standard TRT procedure in order to control the quality on GHP projects. In the TRT procedure interpretation method has a rule that data set has to be interpreted by the line source model(LSM). The LSM employes some assumptions that surrounding medium is homogeneous and the line source is infinite and constant heat flux, however real ground condition is unisotropic and heterogeneous, and showing regional or local ground water flows in many cases. We need to develope improved evaluation models to estimate accurate ground thermal conductivity with respect to geological and influence of ground water because current TRT standard test procedure has limitations to be applied for every locations and system. This study surveyed the uncertainty of the thermal parameters from the interpretation method considering different evaluation period. The interpretation of 208 TRT data sets represents limitations of LSM application that some obtained ground thermal conductivities are statistically unstable and convergence time of ground thermal conductivity over test period shows trends responding the length of test period. This evaluation study will be helpful to provide some effective procedure for the thermal parameter estimation and to complement current TRT standard procedure.

  • PDF

Treatment for Chronic Lateral Instability of the Ankle with Modified Brostrom Procedure(6 cases) (Modified Brostrom 술식을 이용한 만성 족근관절 외측 불안정증의 치료)

  • Park, Yong-Wook;Chung, Yung-Khee;Yoo, Jung-Han;Lee, Kang-Il
    • Journal of Korean Foot and Ankle Society
    • /
    • v.2 no.1
    • /
    • pp.6-12
    • /
    • 1998
  • Many surgical procedures have been described for the treatment of chronic lateral instability of the ankle. Tenodesis procedures using peroneus brevis tendon is traditionally common among them. Recently, the modified Brostrom anatomic procedure, that is, tightening the stretched out lateral ligaments to restore their norma] anatomy without the use of supplemental tissues and then suturing the lateral portion of the extensor retinaculum to the distal fibula over the ligament repair. has been gaining in popularity. We have reviewed 6 of 10 consecutive cases at an average of 17 months after modified Brostrom procedure. An excellent or good result was achieved in 5 cases, all of which had improved mechanical stability as measured radiographically. One case that had an unsatisfactory result was in patient who had had a previous Evans' operation. So, we believed that the modified Brostrom procedure is an excellent treating method for chronic lateral instability of the ankle.

  • PDF

Quantitative Evaluation of Shape Accuracy in a Hat-type Product with UHSS according to the Forming Procedure (성형공법에 따른 초고강도 모자형 박판부품 형상정밀도 평가)

  • Choi, Byeung Hyeun;Kim, Se Ho;Kim, Heung Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.10
    • /
    • pp.1111-1117
    • /
    • 2013
  • In this paper, the shape accuracy of the stamped hat-type product is quantified and analyzed with ultra high strength steel (UHSS) sheets. The shape of the hat-type product is designed in order to simplify the geometry of the side sill and the stamping methodology is proposed in order to verify the effect of the stamping procedure on the springback amount. Experiments and finite element analyses are conducted with four kinds of the forming sequences. The springback amounts are measured and compared according to the forming procedure with the embossing shape. Experimental result in company with analysis one illustrate that the springback amount is reduced with embossing in the padding operation. They also fully demonstrates the proposed forming procedure and the analysis method can be effectively applied to the process design for producing parts with ultra high strength steel.

High Power Density, High Frequency, and High Voltage Pulse Transformer

  • Kim, S.C.;Jeong, S.H.;Nam, S.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.4
    • /
    • pp.180-184
    • /
    • 2001
  • The high operation frequency mainly reduces transformer volume in the power supply. A high frequency and high voltage pulse transformer is designed, fabricated, and tested. Switching frequency of the transformer is 100 kHz. Input and output voltages of the transformer are 250 V and 4 kV, respectively. Normal operation power of the transformer is 3 kW. Maximum volume of the transformer is 400 $cm^3$. The power density is thus 7.5 W/$cm^3$. The transformer will be installed in a metal box that has nominal operation temperature of 85 degree centigrade. The transformer and other high voltage components in the box will be molded with Silicon RTV(Room Temperature Vulcaniza) that has a very low thermal conductivity. Procedure of design and test results are discussed. Analytical as well as experimental results of varous paramters such as transformer loss, leakage inductance, distributed capacitance are also discussed. In addition, thermal analysis results from ANSYS code for three different operation conditions are discussed.

  • PDF

Improved Droop Method for Converter Parallel Operation in Large-Screen LCD TV Applications

  • Kim, Jung-Won;Jang, Paul
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.22-29
    • /
    • 2014
  • Current sharing between modules in a converter parallel operation is very important for the reliability of the system. This paper proposes an improved droop method that can effectively improve current sharing accuracy. The proposed method adaptively adjusts the output voltage set-point of each module according to the current set-points. Unlike conventional droop control, modules share a signal line to communicate with each other. Nevertheless, since signals are simple and in digital form, the complexity of the circuitry is much less and noise immunity is much better than those of conventional methods utilizing communication. The operation principle and design procedure of the proposed method are described in detail. Results of the experiment on two boost converters operating in parallel under the specification of a TFT LCD TV panel power supply verify the validity of the proposed scheme.