• 제목/요약/키워드: Operation efficiency

검색결과 5,548건 처리시간 0.039초

Infrared and visible image fusion based on Laplacian pyramid and generative adversarial network

  • Wang, Juan;Ke, Cong;Wu, Minghu;Liu, Min;Zeng, Chunyan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권5호
    • /
    • pp.1761-1777
    • /
    • 2021
  • An image with infrared features and visible details is obtained by processing infrared and visible images. In this paper, a fusion method based on Laplacian pyramid and generative adversarial network is proposed to obtain high quality fusion images, termed as Laplacian-GAN. Firstly, the base and detail layers are obtained by decomposing the source images. Secondly, we utilize the Laplacian pyramid-based method to fuse these base layers to obtain more information of the base layer. Thirdly, the detail part is fused by a generative adversarial network. In addition, generative adversarial network avoids the manual design complicated fusion rules. Finally, the fused base layer and fused detail layer are reconstructed to obtain the fused image. Experimental results demonstrate that the proposed method can obtain state-of-the-art fusion performance in both visual quality and objective assessment. In terms of visual observation, the fusion image obtained by Laplacian-GAN algorithm in this paper is clearer in detail. At the same time, in the six metrics of MI, AG, EI, MS_SSIM, Qabf and SCD, the algorithm presented in this paper has improved by 0.62%, 7.10%, 14.53%, 12.18%, 34.33% and 12.23%, respectively, compared with the best of the other three algorithms.

동기 리럭턴스 전동기의 에너지 절감을 위한 효율 최적화 제어 (Efficiency Optimization Control for Energy Saving of Synchronous Reluctance Motor)

  • 이정철;이흥균;정동화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.159-162
    • /
    • 2001
  • This paper is proposed an efficiency optimization operation algorithm for synchronous reluctance motor (SynRM) using current phase angle control technique. The SynRM has to controlled with the optimal current phase angles with load and operation speed variation, to obtain high efficiency over the wide speed ranges. An efficiency optimization condition in SynRM which minimizes the copper and iron losses is derived based on the equivalent circuit model of the machine. The objective of the efficiency optimization control algorithm compensating the optimum current angle, is to seek a combination of d and q-axis current components which provides minimum losses at a certain operating point in steady state. The usefulness of the proposed efficiency optimization control is verified through vector-controlled inverter system with the SynRM.

  • PDF

A Study on the Routing of Onboard Oriented Control System by Operation Scenario

  • Baek, Jong-Hyen;Kim, Yong-Gyu;Song, Yong-Soo;Oh, Se-Chan;Shin, Dong-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권4호
    • /
    • pp.473-477
    • /
    • 2013
  • The railway developed countries in Europe, Japan such as ERTMS Regional, FFB, COMBAT, it is the stage of development or testing the train control system for the signal system of branch interval of low density. Similar to the signal system used by the mainline and branch sections of low density domestic portions not suitable in terms of maintenance operational efficiency in accordance with the installation and operation in many cases. Therefore these low-density branch railway lines required that oriented train control system of wireless communication to improve the operation efficiency and line side equipment controlled on board the train. In this paper, We was published a route on setting is the operation of the new on-board oriented train control system for controlling a line converter of the train so that it is possible to improve the operational efficiency of the branch of the low density.

GaN-FET 기반의 고효율 및 고전력밀도 경계전류모드 능동 클램프 플라이백 컨버터 최적설계 (Optimal Design of GaN-FET based High Efficiency and High Power Density Boundary Conduction Mode Active Clamp Flyback Converter)

  • 이창민;구현수;지상근;유동균;강정일;한상규
    • 전력전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.259-267
    • /
    • 2019
  • An active clamp flyback (ACF) converter applies a clamp circuit and circulates the energy of leakage inductance to the input side, thereby achieving a zero-voltage switching (ZVS) operation and greatly reducing switching losses. The switching losses are further reduced by applying a gallium nitride field effect transistor (GaN-FET) with excellent switching characteristics, and ZVS operation can be accomplished under light load with boundary conduction mode (BCM) operation. Optimal design is performed on the basis of loss analysis by selecting magnetization inductance based on BCM operation and a clamp capacitor for loss reduction. Therefore, the size of the reactive element can be reduced through high-frequency operation, and a high-efficiency and high-power-density converter can be achieved. This study proposes an optimal design for a high-efficiency and high-power-density BCM ACF converter based on GaN-FETs and verifies it through experimental results of a 65 W-rated prototype.

고열을 이용한 잔류 오존($O_3$) 처리에 관한 연구 (The study on the treatment of the remaining Ozone($O_3$) by the high heater)

  • 김재우
    • 환경위생공학
    • /
    • 제16권2호
    • /
    • pp.9-16
    • /
    • 2001
  • If a pollutant invade at liguid and gas, it will be use ozone in order to remove or sterilize. Ozone excessively supply in order to receive satisfactory efficiency. If excessive ozone leave like that, second-problem will be occur. This study used high heater in order to treat occurred ozone. ; the results were as follow : 1. As initial ozone os supplied with $1.789{\;}g/m^3$ : For the 40, 50, 60, 70(V) of electric potential $O_3$ removal efficiency was treated 34.41, 73.78, 98.60, 98.97%(time of operation ; after 5min.). 2. As initial ozone is supplied with $3.645{\;}g/m^3$ : For the 40, 50, 60, 70(V) of electric potential, $O_3$ removal efficiency was treated 1.78, 69.27, 99.18, 98.68%(time of operation ; after 5min.). 3. As initial ozone is supplied with $4.759{\;}g/m^3$ : For the 50, 60, 70(V) of electric potential, $O_3$ removal efficiency was treated 61.29, 99.29, 99.18%(Time of operation ; after 5min.). 4. Used electric power is 15.38, 24.00, 35.29, 46.15(w/hr) at the 40, 50, 60, 70(V) of the electric potential. 5. Regarding electric power and $O_3$ removal efficiency, Used electric pote-ntial economized at 60(V).

  • PDF

High-efficiency Operation of Switched Reluctance Generator based on Current Waveform Control

  • Li, Zhenguo;Yu, Siyang;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.120-126
    • /
    • 2013
  • The main aim of this paper is to expound high-efficiency operation of Switched Reluctance Generator (SRG) based on the current waveform. For this purpose, theoretical analysis of the copper loss and iron loss of the system is done first. Then, necessary simulation is done to find the variation trend of the copper loss and iron loss with the variation of the current waveform at the same output power. Finally, the best current waveform which can make the system operate with high efficiency is obtained by considering the influence of these two kinds of loss. In order to verity the simulation results, the experimental platform of DC motor-SRG is built and the modified angle position control (APC) method which can specify the current shape optionally is presented. By comparing the system efficiency at the three kinds of typical current waveform, the correctness and feasibility of the theory is verified. The proposed method is simple, reliable, and easy to achieve.

고효율, 고전력밀도 아답터를 위한 도통밴드 제어 AC-DC 벅 컨버터 (A Conduction Band Control AC-DC Buck Converter for a High Efficiency and High Power Density Adapter)

  • 문상철;정봉근;구관본
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.38-39
    • /
    • 2017
  • This paper proposes a new control method for an AC-DC Buck converter which is utilized as a front-end converter of a 2-stage high power density adapter. In the conventional adapter applications, 2-stage configuration shows higher power transfer efficiency and higher power density than those of the single stage flyback converter. In the 2-stage AC-DC converter, the boost converter is widely used as a front-end converter. However, an efficiency variation between high AC line and low AC line is large. On the other hand, the proposed conduction band control method for a buck front-end converter has an advantage of small efficiency variation. In the proposed control method, switching operation is determined by a band control voltage which represents output load condition, and an AC line voltage. If the output load increasesin low AC line, the switching operation range is expanded in half of line cycle. On the contrary, in light load and high line condition, the switching operation is narrowed. Thus, the proposed control method reduces switching loss under high AC line and light load condition. A 60W prototype which is configured the buck and LLC converter with the proposed control method is experimented on to verify the validity of the proposed system. The prototype shows 92.16% of AC-DC overall efficiency and 20.19 W/in 3 of power density.

  • PDF

독립형 DC마이크로그리드 내 BESS용 4 LEG DC/DC 컨버터의 고장허용 및 고효율 제어에 관한 연구 (A Study on the Fault Tolerance and High Efficiency Control of 4 Leg DC/DC Converter for Battery Energy Storage System in Standalone DC Micro-grid)

  • 최정식;오승열;차대석;정동화
    • 전기학회논문지
    • /
    • 제67권9호
    • /
    • pp.1239-1248
    • /
    • 2018
  • This paper proposes a fault tolerant and high efficiency operation algorithm for a 4 LEG DC/DC converter for a battery energy storage system(BESS) forming a main power source in a standalone DC micro grid. The BESS for the main power supply in the stand-alone DC micro-grid is required to operate at high speed according to fault tolerant control and load by operating at all times. Fault-tolerance control changes the short-circuit fault to an open-circuit fault by using a fuse in case of leg fault in 4 legs, and operates stably through phase shift control. In addition, considering the loss of the power semiconductor, the number of LEG operation is adjusted to operate at high efficiency in the full load region. In this paper, fault tolerant control and high efficiency operation algorithm of DC/DC converter for BESS in standalone DC micro grid is presented and it is proved through simulation and experiment.

지역 장애인복지시설의 운영효율성 및 영향요인 분석 -전라지역 중증장애인 거주시설을 중심으로- (Analysis of the Operation Efficiency and Influence Factors of Local Welfare Facilities for the Disabled -Focusing on Housing Facilities of the Severely Disabled in Jeolla Region-)

  • 이형배
    • 디지털융복합연구
    • /
    • 제12권12호
    • /
    • pp.611-620
    • /
    • 2014
  • 본 연구는 DEA 모형을 활용하여 전라지역 중증장애인 거주시설의 운영효율성 및 영향요인 분석을 수행하였다. 첫째, CCR 모형을 이용한 2012년의 효율성 분석을 수행하였으며, 그 결과 12개 DMU가 효율적으로 판명되었고, CCR 평균효율성은 0.85로 전체 DMU의 효율성이 양호함을 확인하였다. 둘째, DEA 모형의 효율성 영향요인 분석을 위해서 Tobit 모형을 이용하여 투입 및 산출변수를 독립변수로 하고 효율성을 종속변수로 하는 회귀분석을 실시하였으며, 그 결과 세부변수의 유의성은 낮았으나, 전체적으로 투입변수는 효율성에 부(-)의 영향력을 보이고 산출변수는 정(+)의 영향력 경향을 보였으며, 운영효율성에서 종사자수 외의 투입변수에서 유의미한 결과가 나타나지 않은 점은 결국 중증장애인 거주시설은 투입변수에 대한 확대보다는 복지 전달체계, 운영환경 및 구조 개선, 프로그램 보완 등의 노력이 필요한 것으로 볼 수 있다.

교류 전동기의 고효율 운전을 위한 3상 인버터의 입력전력 추정 기법 (Input Power Estimation Method of a Three-phase Inverter for High Efficiency Operation of an AC Motor)

  • 김도현;김상훈
    • 전력전자학회논문지
    • /
    • 제24권6호
    • /
    • pp.445-451
    • /
    • 2019
  • An input power estimation method of a three-phase inverter for the high-efficiency operation of AC motors is proposed. Measuring devices, such as DC link voltage and input current sensors, are required to obtain the input power of the inverter. In the proposed method, the input power of the inverter can be estimated without the input current sensor by using the phase current information of the AC motor and the switching pattern of the inverter. The proposed method is more robust to parameter error than conventional method. The validity of the input power estimation method is verified through experiments conducted on a 1 kW permanent-magnet synchronous motor drive system.