• 제목/요약/키워드: Operation System

검색결과 20,228건 처리시간 0.047초

배전계통 운영비용의 최소화에 의한 분산전원의 최적 용량과 위치결정 (Optimal Capacity and Allocation Distributed Generation by Minimization Operation Cost of Distribution System)

  • 배인수;박정훈;김진오;김규호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권9호
    • /
    • pp.481-486
    • /
    • 2004
  • In operation of distribution system, $DG_s$ Distributed Generations) are installed as an alternative of extension and establishment of substations and transmission and distribution lines according to increasing power demand. In operation planning of $DG_s$, determining optimal capacity and allocation gets economical pro(it and improves power reliability. This paper proposes determining a optimal number, size and allocation of $DG_s$ needed to minimize operation cost of distribution system. Capacity of $DG_s$ (or economical operation of distribution system estimated by the load growth and line capacity during operation planning duration, DG allocations are determined to minimize total cost with power buying cost. operation cost of DG, loss cost and outage cost using GA(Genetic Algorithm).

DISCRETE EVENT SYSTEM SIMULATION APPROACH FOR AN OPERATION ANALYSIS OF A HEADEND PROCESS FACILITY

  • Lee, Hyo-Jik;Kim, Sung-Hyun;Park, Byung-Suk
    • Nuclear Engineering and Technology
    • /
    • 제41권5호
    • /
    • pp.739-746
    • /
    • 2009
  • This paper introduces facility operation modeling and simulation based primarily on a discrete event system modeling scheme. Many modern industrial facilities are so complex that their operational status cannot be estimated by simple calculations. In general, a facility can consist of many processes and transfers of material between processes that may be modeled as a discrete event system. This paper introduces the current status of studies on operation modeling and simulation for typical nuclear facilities, along with some examples. In addition, this paper provides insights about how a discrete event system can be applied to a model for a nuclear facility. A headend facility is chosen for operation modeling and the simulation, and detailed procedure is thoroughly described from modeling to an analysis of discrete event results. These kinds of modeling and simulation are very important because they can contribute to facility design and operation in terms of prediction of system behavior, quantification of facility capacity, bottleneck identification and efficient operation scheduling.

A Study on the Deriving Requirements of ARGO Operation System

  • Seo, Yoon-Kyung;Rew, Dong-Young;Lim, Hyung-Chul;Park, In-Kwan;Yim, Hong-Suh;Jo, Jung-Hyun;Park, Jong-Uk
    • Journal of Astronomy and Space Sciences
    • /
    • 제26권4호
    • /
    • pp.643-650
    • /
    • 2009
  • Korea Astronomy and Space Science Institute (KASI) has been developing one mobile and one stationary SLR system since 2008 named as ARGO-M and ARGO-F, respectively. KASI finished the step of deriving the system requirements of ARGO. The requirements include definitions and scopes of various software and hardware components which are necessary for developing the ARGO-M operation system. And the requirements define function, performance, and interface requirements. The operation system consisting of ARGO-M site, ARGO-F site, and Remote Operation Center (ROC) inside KASI is designed for remote access and the automatic tracking and control system which are the main operation concept of ARGO system. To accomplish remote operation, we are considering remote access to ARGO-F and ARGO-M from ROC. The mobile-phone service allows us to access the ARGO-F remotely and to control the system in an emergency. To implement fully automatic tracking and control function in ARGO-F, we have investigated and described the requirements about the automatic aircraft detection system and the various meteorological sensors. This paper addresses the requirements of ARGO Operation System.

도시철도 화재$\cdot$단전시 최적 열차운행을 위한 통합운영체계 구축방안에 관한 연구 (A Case study on the plan for the ESC integrating optimized train operation system for Fire & power failure accident in subway)

  • 김영욱;최세완;김용규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1185-1192
    • /
    • 2004
  • Recently heavy traffic is getting worse because increasing population of transportation in urban area. In order to solve this problem. subway is realized with high speed, high density, highly efficiency. When fire accident happened in Dae-Gu subway in February 2003, there happened loss of people and lots of damage because of not being able to control even though fire alarm which was set up in the station rang. This thesis has constructed a simulation integrating operation system using a Database construction, operating program analysis in order to build up the most efficient train operation system. The result of simulation integrating operation system with emergency virtual situation like station and train fire, train failure, power line failure, all trains running on the rail were secured safety by train operation control system. With integrating operation of each train control system, train system, power system, machine facility system, the most efficient integrating operation system should have been constructed at the time the subway fire and power failure broke out.

  • PDF

다수의 히트펌프로 구성된 냉난방시스템에서 하절기 히트펌프의 최적운전에 관한 연구 (A Study on Optimal Operation of Summer Season Cooling System with Numbers of Heat Pumps)

  • 신관우
    • 전기학회논문지P
    • /
    • 제55권1호
    • /
    • pp.35-40
    • /
    • 2006
  • Heat-pump system has a special feature that provides heating operation in winter season and cooling operation in summer season with a single system. It also has a merit that absorbs and makes use of wastewater heat, terrestrial heat, and heat energy from the air. Because heat-pump system uses midnight electric power, it decreases power peak load and is very economical as a result. By using the property that energy source is converted to low temperature when losing the heat, high temperature energy source is used to provide heating water and low temperature energy source is used to provide cooling water simultaneously in summer season. This study made up a heat-pump system with 4 air heat sources and a water heat source and implemented the optimal operation algorithm that works with numbers of heat pumps to operate them efficiently. With the heat-pump system, we applied it to cooling and heating operation in summer season operation mode in a real building.

실시간 전력계통 운영을 위한 데이터 시각화에 관한 연구 (A Study on the Data Visualization for Real Time Power System Operation)

  • 조윤성;정진영
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1361-1367
    • /
    • 2013
  • This paper describes and suggests the data visualization for real time power system operation based on energy management system. Because real time power system operation performs analysis of the vast amount of on-line data, the operators need intuitive data visualization to find out useful information in the big data. Especially, in emergency situation, the data visualization is able to assist the operators in handling the crisis quickly and efficiently. Therefore, this paper aims to improve displays of output of real time power system operation by visualizing on-line big data. Through this study, we can develop improved visualization technique for real time power system operation, which has highly readable displays of output and intuitive information.

A study on efficient gate system based RFID at the container terminal

  • Kim, Hyun;Kim, Yul-Seong
    • 한국항해항만학회지
    • /
    • 제30권4호
    • /
    • pp.277-283
    • /
    • 2006
  • It is a world trend to construct large terminal and develop automated container terminal to attract Super Post-Panamax and provide service which is based on differentiation. In fact, there is insufficient research for automatization of terminal gate since the automatization of current constructed container terminal is only focused on increasing productivity and unmanned system through the automatization of quay, yard, etc. In this paper, we have investigated advantage/disadvantage of existing gate operation systems and compared each gate operation system in the aspect of raising terminal image and the productivity. For the specific study, we have used data from actual terminal gate operation and RFID model business sponsored by MOMAF (Ministry of Maritime Affairs and Fisheries). As a result, this paper carried out an efficient gate operation system and it has been expected that it will be performed as groundwork of automated gate operation system which is for design of container terminal and improvement of gate operation system.

NASA EOS DB Receiving System Development by KARI

  • Ahn, Sang-Il;Koo, In-Hoi;Yang, Hyung-Mo;Hyun, Dae-Hwan;Choi, Hae-Jin
    • 대한원격탐사학회지
    • /
    • 제19권1호
    • /
    • pp.37-42
    • /
    • 2003
  • Recently, KARI implemented the receiving and processing system for MODIS sensor data from NASA EOS satellites (TERRA and AQUA). This paper shows the development strategy considered, system requirement derived, system design, characteristic and test results of processing system. System operation concept and sample image are also provided. Implemented system was proven to be fully operational through lots of pass operations activities from RF signal reception to level-1 processing.

대추수확기의 집과시스템 개발에 관한 연구 (Development of a Collecting System for Jujube Harvester)

  • 이상우;김도형;이창규;서신원;허윤근
    • Journal of Biosystems Engineering
    • /
    • 제31권6호
    • /
    • pp.500-505
    • /
    • 2006
  • Jujube is one of korean most favorite fruits. Harvesting operations of the jujube farming, however, completely depend on hand labor. Especially, collecting operation requires about three times of hand labor compared with separate operation by impacting or shaking of twigs in the hand-harvesting system of jujube fruits. Consequently, jujube farmers sincerely demand the mechanization of the collecting operation of jujube fruits in the harvesting operation. A new collecting system was designed and constructed five parts-collecting pad, guide ring system, sorting system, frame with driving system, and handle with operation levers, which performed collecting operation of jujube fruits without missing fruits in five part functions, however, an extra future more deliberate study would need how to handle conveniently the collecting pad of the prototype in the narrow space of row of the jujube farm.

운영시스템에 의한 컨테이너터미널의 생산성 향상 평가 (An Evaluation of Productivity Improvement for Container Terminal by Operation System)

  • 최용석;하태영
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2004년도 춘계학술대회 논문집
    • /
    • pp.385-392
    • /
    • 2004
  • 본 연구의 목적은 컨테이너터미널의 생산성 향상을 위한 새로운 운영시스템 기술 도입에 따른 효과를 분석하는 것이다. 컨테이너터미널의 운영시스템은 종합관제시스템, 운영시스템, 계획시스템, IT기술 등의 크게 네가지 기능으로 분류하며, 총 19가지 신기술 대안을 선정하였다. 선정된 운영시스템 기술대안에 대한 현장 전문가에 대한 설문조사와 면담조사를 통하여 운영시스템 기술대안에 대한 중요도와 생산성 향상지수를 추정하고 생산성 향상 평가모형을 수립하였으며, 생산성 향상 평가모형을 이용하여 운영시스템 기술 도입에 따른 대안별 생산성 향상을 평가하였다. 새로운 운영시스템 도입시 생산성 향상에 미치는 영향을 분석하고자 할 경우에 사용가능한 방법을 제안한다.

  • PDF