• Title/Summary/Keyword: Operation Scheme

Search Result 1,988, Processing Time 0.035 seconds

Maximum torque control of SynRM drive using ANN (ANN을 이용한 SynRM 드라이브의 최대토크 제어)

  • Ko, Jae-Sub;Park, Ki-Tae;Choi, Jung-Sik;Park, Byung-Sang;Chung, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.311-315
    • /
    • 2007
  • In this paper, a new approach for the Synchronous Reluctance Motor control which ensures producing Maximum Torque per Ampere(MTPA) over the entire field weakening region is presented. In addition, This paper presents a speed sensorless control scheme of SynRM using artificial neural network. Also, by adjusting the base speed for the field weakening operation according to the flux level, the current and voltage limit, the smooth and precise transition into the field weakening operation can be achieved The proposed scheme is verified validity through simulation.

  • PDF

Prospective Scheme of Network Based Battle Management System in AMD (공중.미사일방어의 네트워크중심 전장관리체계 발전방안)

  • Kwon, Yong-Soo;Ham, Byung-Woon;Kim, Ha-Chul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.50-60
    • /
    • 2006
  • This work describes a basic concept of network based battle management system in AMD(Air & Missile Defense). The AMD operation inherently is joint concept that each single service do not satisfy the requirements of AMD theater operation. It is integrated system of joint forces that is operated simultaneously. The analysis of the future battlespace and air & missile threat is shown. From this analysis the prospective scheme of network based battle management system in building Korean future AMD is presented.

A Three-Phase Converter with High Power Factor Using Soft-Switching Module (소프트 스위칭 모듈을 이용한 3상 고역률 컨버터)

  • 김재홍;정진규;백승택;한병문;김현우
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.663-666
    • /
    • 1999
  • This paper describes a three-phase converter with high power factor using a scheme of discontinuous current mode(DCM). The proposed system can replace the conventional diode bridge with step-up chopper which is used as a converter for adjustable speed drive. In this system, the current of reactor is zero at turn-on instance because of operation in DCM, while the switch turns off at the instance of maximum current. A soft-switching scheme with lossless snubber was proposed. Therefore, a zero-voltage switching at turn off can be achived by lossless snubber and zero-current switching at turn on can be obtained by operating under DCM. A theoretical analysis and computer simulations with PSpice were done to verify the operation of the proposed system. Also a prototype of hardware system was built and tested for verifying the feasibility of proposed system.

  • PDF

Maximum Torque Control of SynRM Drive with Artificial Neural Network (인공 신경회로망에 의한 SynRM 드라이브의 최대토크 제어)

  • Ko, Jae-Sub;Nam, Su-Myeong;Chung, Dong-Hwa
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.185-191
    • /
    • 2005
  • In this paper, a new approach for the Synchronous Reluctance Motor control which ensures producing Maximum Torque per Ampere(MTPA) over the entire field weakening region is presented. In addition, This paper presents a speed sensorless control scheme of SynRM using artificial neural network. Also, by adjusting the base speed for the field weakening operation according to the flux level, the current and voltage limit, the smooth and precise transition into the field weakening operation can be achieved. The proposed scheme is verified validity through simulation.

Operational Efficiency Scheme of Mailing Center for Automation (자동화 중심 우편집중국 운영 효율화 방안)

  • Um Insup;Lee Hongchul;Kang Jungyun
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.05a
    • /
    • pp.999-1006
    • /
    • 2003
  • This research presents efficient operation schemes that is emphasized on mailing center's automation parts. We utilized the automation indicator to analyzed the mailing center system. For automation of the mailing center, we proposed the sorting automation alternative of registered mail, automation of conveyance system between workshops and the Up-Grade scheme for process improvement in mailing center. The selection of the registered mailing f s automation alternatives is composed of the AHP(Analytic Hierarchy Process) method. Through the analysis of the space and the quantity of materials, the simulation experiments are conducted to examine conveyance equipment possibility of the mailing center. By simplifying the mailing center conceptually, we proposed the upgrade of process for the mailing center system. The result of this research can give some ideas to people who are formulating a policy for the mailing center operation.

  • PDF

Asymmetry Components Reduction using Superconducting Fault Current Limiter Operation in Transient Period (비대칭 고장전류 저감을 위한 초전도 한류기 동작 분석)

  • Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Kyu-Ho;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.381-382
    • /
    • 2008
  • This paper presents a novel scheme for reducing an asymmetry current with SFCL (Superconducting Fault Current Limiter) operation during transient period, when a fault occurs in power systems. The main idea is installation an auxiliary SFCL with characteristics, which reduces the asymmetry fault current in first half cycle before the operating of main SFCL. For proper activities of SFCLs, the principle of asymmetry current nature is reviewed. A scheme of asymmetry components reduction with SFCL is then explained. The EMTP/ATPDraw model of SFCLs using MODELS language developed and simulated to verify the performance and effectiveness.

  • PDF

Operation Scheme to Regulate Constant Active Power Output of Wind Turbine and Fuel-Cell Hybrid System (정출력 조정을 위한 풍력-연료전지 하이브리드 시스템의 운영 기법)

  • Kim, Yun-Seong;Moon, Dae-Seong;Won, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1174-1175
    • /
    • 2008
  • A operation scheme to regulate the active power output of the hybrid system consisted of a doubly fed induction generator(DFIG) and a fuel-cell are presented. The power output of the wind turbine fluctuates as the wind speed varies and the slip power between the rotor circuit and power converter varies as the rotor speed change. A fuel cell system can be individually operated and adjusted output power. In this paper, a fuel-cell is performed to regulate the active output power in comparison with the active power output of a DFIG. Based on PSCAD/EMTDC power system tools, we simulated a DFIG and a fuel cell and investigated about dynamics of the output power in hybrid system.

  • PDF

A Study on Operation Scheme of STS with Emergency Generator for Peak Shedding (첨두부하 저감을 위한 비상발전기 연계형 STS 운영 방안에 관한 연구)

  • Kim, Chang-Hwan;Rhee, Sang-Bong;Kim, Kyu-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.155-156
    • /
    • 2015
  • Recently, electricity consumption has rapidly increased along with economic growth. The operating strategy using emergency generator is aimed, to resolve a demand response management. For strategy of peak shedding using emergency generator, it is essential to introduce the fast transfer switching device. One of the most effective solutions is to use a static transfer switch (STS) based on thyristor. However, the characteristic of natural commutated SCR thyristor should anticipate short duration voltage sag. STS system thus requires more than a quarter cycle to successfully complete transfer process. This paper proposes the operation scheme of the STS system using the forced-commutation technique to mitigate instantaneous voltage sag during peak transfer process. Proposed STS system improved turn-off characteristic thus accomplishes the peak load shedding satisfied power quality. Performance of the proposed STS system is evaluated using electromagnetic transient program (EMTP) to confirm the effectiveness.

  • PDF

Hand Acupuncture Supporting System using Mixed Reality Scheme (Mixed Reality 기술을 이용한 수지침 학습 및 시술지원 시스템)

  • Kim, Gi-Ho;Yu, Hwang-Bin
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.5
    • /
    • pp.1351-1360
    • /
    • 2000
  • The hand acupuncture, called Sujichim, is mostly conducted at home. Many people try to learn and apply the Sujichim treatment to the health care of their family. This paper proposes a mixed reality scheme for the hand acupuncture supporting system. Using our system, a novice can easily perform the acupuncture by himself to improve his body condition. Our system has two major phases: learning phase and operation phase. In learning phase, we extract the finger joint lines from the real world image, where the lines are very important for finding the acupuncture spots on a hand. In operation mode, user can easily make Sujichim treatment by the knowledge provided by the computer. According to the experiments, our system is proved to be very effective and easy to use.

  • PDF

Low Speed Operation of Simplified Sensorless Control of Synchronous Reluctance Motor (동기형 릴럭턴스 전동기의 단순구조형 센서리스 제어의 저속운전)

  • Ahn, Joon-Seon;Lee, Ju
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.2
    • /
    • pp.61-68
    • /
    • 2006
  • Many researchers have worked for the sensorless control of SynRM in recent years. However they commonly requires large calculations which induced from its complexity. For low cost application as like home appliance, it is difficult to utilize because of the cost problem. Therefore, it is necessary to introduce simplified sensorless control scheme that is composed of least calculation to estimate the rotor position. In this paper the sensorless control is performed using the characteristics of SynRM structure in which the linkage flux varies with rotor position, so the rotor position can be detected by the change of linkage flux. The estimation of linkage flux can be acquired from the integration of the motor terminal voltage which is commonly used method for the reliability of the estimation. However this estimation method has demerits in low speed operation therefore in that region the motor terminal voltage is compensated by the phase current. A digital simulation (MATLAB) and experiment were performed to confirm the adequacy of the proposed control scheme.