• Title/Summary/Keyword: Operation Deviation

Search Result 427, Processing Time 0.039 seconds

Asbestos Content in Friable Sprayed-on Surface Material and Airborne Fiber Concentrations in Commercial Buildings (대형건물내 비고형 석면함유 건축자재에 의한 기중 석면오염 및 관리실태)

  • Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.137-146
    • /
    • 1995
  • Twenty(20) large commercial buildings located in Seoul with friable sprayed-on surface insulation material on ceilings were investigated for asbestos content in bulk material by polarized light microscopy and for airborne fiber concentrations in buildings by phase contrast microscopy. In addition, such building-related variables as building age, numbers of traffic, airflow, surface conditions of the ceiling, temperature, and humidity were studied for any correlation with airborne fiber concentrations. The results were as follows: 1. Chrysotile asbestos was found in two bulk samples with 3-5% content and with <1%in one sample out of total 20 bulk samples collected. Glass fiber and mineral wool were the two major constituents of the bulk samples. 2. The ceiling surfaces were very friable in 16 buildings and were relatively hard in 4 buildings. The friability of the surface material was dependent upon the type and the amount of binder that had been mixed with the sprayed-on surface material. 3. Airborne fiber concentrations were log-normally distributed and the geometric mean(geometric standard deviation) fiber concentrations in the underground parking lots, inside buildings, and outdoor ambient air were 0.0063(1.97)f/cc, 0.0068(2.29)f/cc, and 0.0033(2.36)f/cc, respectively. 4. No significant relationship of airborne fiber concentrations and all building-related variables studied except humidity was found. The results of this study suggest that the sprayed-on surface insulation material found in some commercial buildings may possibly be contaminated with asbestos. Since most of the ceiling surfaces surveyed were very friable and poorly maintained and the airborne fiber concentrations were relatively high, there is a possibility of asbestos fiber contamination in these buildings, particularly at those buildings with asbestos-contaminated surface material. Since poorly maintained surface conditions were thought to be a source of high airborne fiber concentrations, there is a urgent need of a systematic operation and maintenance program. Further study of non-occupational asbestos exposure in general population utilizing advanced analytical technique such as transmission electron microscopy is highly recommended.

  • PDF

Introgression of Sex-Limited Larval Markings to a Productive Multivoltine Strain of Silkworm Bombyx mori L.

  • Rao, D. Raghavendra;Singh Ravindra;Basavaraja H.K.;Kariappa B.K.;Dandin S.B.;Rufaie S.Z. Haque
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.13 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • A breeding programme was initiated during 2001 to introduce sex-limited larval markings to a productive multivoltine breed - BL67 from an inbred sex-limited line, MY1 (SL) maintained at Central Sericultural Research and Training Institute, Mysore. Introgressive hybridization, recurrent backcrossing for six generations followed by sib-mating resulted in synthesis of a new multivoltine silkworm breed BL67 (SL) with sex-limited larval markings. The new breed was studied for combining ability by crossing with eight bivoltine breeds viz., $NB_4D_2,\;CSR_2,\;CSR_2 (SL),\;CSR_2,\;CSR_4,\;CSR_8,\;CSR_{18}\;and\;CSR_{19}$. General combining ability effects of the new breed showed its superiority over the popular Pure Mysore by expressing significant GCA effects for six out of twelve characters whereas the results are on par with the original multivoltine breed. The hybrid $BL67(SL){\times}CSR2(SL)$ excelled in several quantitative characters such as pupation rate (90.2%), cocoon weight (1.97 g), cocoon shell weight (40 cg), cocoon shell ratio (20.3%), filament length (918 m), denier (2.96), raw silk percentage (14.96%) and neatness (90 p). Studies on cocoon size variability revealed that the cocoons of $BL67(SL){\times}CSR2(SL)$ were found comparatively uniform showing less standard deviation of 6.55 and co-efficient of variation of 3.91 %. The suitability of newly developed breed for easy grain age operation and commercial exploitation with promising hybrid have been discussed.

Optimal Control of Voltage and Reactive Power in Local Area Using Genetic Algorithm (유전알고리즘을 이용한 지역계통의 전압 및 무효전력 최적제어)

  • 김종율;김학만;남기영
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.42-48
    • /
    • 2003
  • In system planing and operation, voltage and reactive power control is very important. The voltage deviation and system losses can be reduced through control of reactive power sources. In general, there are several different reactive power sources, we used switched shunt capacitor to improve the voltage profile and to reduce system losses. Since there are many switched shunt capacitors in power system, so it if necessary to coordinate these switched shunt capacitors. In this study, Genetic Algorithm (GA) is used to find optimal coordination of switched shunt capacitors in a local area of power system. In case study, the effectiveness of the proposed method is demonstrated in KEPCO's power system. The simulation is performed by PSS/E and the results of simulation are compared with sensitivity method.

Repair of the Cleft Lip using Triangular Cheiloplasty-A Case Report (삼각피판법을 이용한 편측 불완전 구순열 환자의 구순 교정 수술-증례 보고)

  • Song, In-Seok;Hong, Jong-Rak;Choung, Pil-Hoon;Seo, Byoung-Moo
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.10 no.2
    • /
    • pp.67-74
    • /
    • 2007
  • After Tennison introduced a triangular flap method which, for the first time, preserved the Cupid's bow, Randall gave this method a sound mathematical basis. This method is also called as an inferior triangular cheiloplasty which is characterized by making a small triangular flap from the lateral border of cleft destined to be fitted into an incision on the medial side of cleft. He postulated that the height obtained was equal to the sum of the median of the two triangles used in the cheiloplasty. Using this technique, a 22 month-old male patient with incomplete unilateral cleft lip was corrected primarily. The deviation of the columella and flattening of the nostril on the cleft side were minimal. The operation was done under general anesthesia and patient was healed uneventfully. We tried to improve the symmetry and esthetic feature of philtrum, nostril sill, alar-facial groove, preventing the notch formation on the nostril floor, and to reconstruct the muscle sling in the upper part of lip. The shape of Cupid's bow was restored, and the symmetry of columella was regained as a result. In summary, the inferior triangular cheiloplasty is effective to correct the primary unilateral cleft lip, results in the restoration of favorable anatomy and function.

  • PDF

Elements and Application of "SmartHome" Concept for Older Adults in USA (미국에서 노인을 위한 "스마트홈(SmartHome)" 개념의 요소와 적용)

  • Moon, Changho
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.4
    • /
    • pp.7-14
    • /
    • 2011
  • This paper is intended to suggest some reference materials for future elderly housing design, especially smart home, in Korea, by reviewing the elements and applications of smart home concept for older adults in USA. Research method includes collecting materials by attending the regular SmartHome$^{(R)}$ part meeting, the navigation of related homepages, and the analysis of collected materials. Current researches in Korea look initial stage and show some general principles without practical concept & technologies of elderly facilities. SeniorSmart$^{(R)}$ Center in USA started on August 2007 with the 3 parts of SmartHOME$^{(R)}$, SmartWHEELS$^{(R)}$ and SmartBRAIN$^{(R)}$. The Center has been doing various multidisciplinary research projects but slowing down the planned processes due to national economic recession. The major researches of SmartHome$^{(R)}$ part can be summarized as follows; CS-PFP( Continuous Scale Physical Function Performance) laboratory is being in operation to help older adults and families make the difficult decision regarding the ability and safety to live independently. Three levels of necessary laboratories from uninhabited space to senior living environment were accommodated for field research. As core technologies of SmartHome$^{(R)}$, predicting & warning system of fall risk on recognizing gait signature patterns to identify any deviation from the normal patterns of the older adults, home monitoring system which will send alerts to a specified relative and/or health care professional when vital signs of the older adults will not be within normal parameters, and Mobility & Research Clinic for evaluating, treating the older adults & multidisciplinary research are under development. SmartHome$^{(R)}$ has made collaborative research agreements for field laboratory with various retirement communities and also is continuing to work for experimental software engineering with the Fraunhofer Institute, Germany.

Large Point Cloud-based Pipe Shape Reverse Engineering Automation Method (대용량 포인트 클라우드 기반 파이프 형상 역설계 자동화 방법 연구)

  • Kang, Tae-Wook;Kim, Ji-Eum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.692-698
    • /
    • 2016
  • Recently, the facility extension construction and maintenance market portion has increased instead of decreased the newly facility construction. In this context, it is important to examine the reverse engineering of MEP (Mechanical Electrical and Plumbing) facilities, which have the high operation and management cost in the architecture domains. The purpose of this study was to suggest the Large Point Cloud-based Pipe Shape Reverse Engineering Method. To conduct the study, the related researches were surveyed and the reverse engineering automation method of the pipe shapes considering large point cloud was proposed. Based on the method, the prototype was developed and the results were validated. The proposed method is suitable for large data processing considering the validation results because the rendering performance standard deviation related to the 3D point cloud massive data searching was 0.004 seconds.

An Economic Design of the Integrated Process Control Procedure with Repeated Adjustments and EWMA Monitoring

  • Park Changsoon;Jeong Yoonjoon
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2004.11a
    • /
    • pp.179-184
    • /
    • 2004
  • Statistical process control (SPC) and engineering process control (EPC) are based on different strategies for process quality improvement. SPC reduces process variability by detecting and eliminating special causes of process variation, while EPC reduces process variability by adjusting compensatory variables to keep the quality variable close to target. Recently there has been need for an integrated process control (IPC) procedure which combines the two strategies. This article considers a scheme that simultaneously applies SPC and EPC techniques to reduce the variation of a process. The process disturbance model under consideration is an IMA(1,1) model with a location shift. The EPC part of the scheme adjusts the process, while the SPC part of the scheme detects the occurrence of a special cause. For adjusting the process repeated adjustment is applied by compensating the predicted deviation from target. For detecting special causes the two kinds of exponentially weighted moving average (EWMA) control chart are applied to the observed deviations: One for detecting location shift and the other for detecting increment of variability. It was assumed that the adjustment of the process under the presence of a special cause may change any of the process parameters as well as the system gain. The effectiveness of the IPC scheme is evaluated in the context of the average cost per unit time (ACU) during the operation of the scheme. One major objective of this article is to investigate the effects of the process parameters to the ACU. Another major objective is to give a practical guide for the efficient selection of the parameters of the two EWMA control charts.

  • PDF

A Study on the Load Frequency Control of Power System Using an Optimal Modulation Controller (최적 변조제어기를 이용한 전력시스템의 부하주파수 제어에 관한 연구)

  • 정형환;허동렬;정문규;주석민;이준탁
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.299-306
    • /
    • 2002
  • The load frequency control(LFC) of power system is one of important subjects in view of system operation and control. That is, even though the rapid load disturbances are applied to the given power system, the stable and reliable power should be supplied to the users, converging unconditionally and rapidly the frequency deviations and the tie-line power flow ones of each area into allowable boundary limits. Nonetheless of such needs, if the internal parameter perturbation and the sudden load variation are given, the unstable phenomena of power systems can be often brought out because of the large frequency deviation and the unsuppressible power line one. So, an optimal modulation controller for UC of multi-area power system is designed by a recursive algorithm that determines the state weighting matrix Q of a linear quadratic performance criterion. The optimal modulation controller is based on optimal control and can obtain the exact dynamic response of the UC of multi-area power system in the time domain. The performances of the resultant optimal modulation control, that is, the steady-state deviations of frequency and tie-line power flow and the related dynamics, were investigated and analyzed in detail by being applied to the UC of multi-area power system in the perturbations of predetermined internal parameters. Through the simulation results tried variously in this paper for disturbance of stepwise load changes, the superiorities of the proposed optimal modulation controller in robustness and stability were proved.

Evaluation of EtherCAT Clock Synchronization in Distributed Control Systems (분산 제어 시스템을 위한 EtherCAT 시계 동기화의 성능 평가)

  • Kim, Woonggy;Sung, Minyoung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.7
    • /
    • pp.785-797
    • /
    • 2014
  • Support for the precise time synchronization of EtherCAT, known as distributed clock (DC), enables the design of highly synchronized operations in distributed real-time systems. This study evaluates the performance of the EtherCAT DC through extensive experiments in a real automation system. We constructed an EtherCAT control system using Xenomai and IgH EtherCAT stack, and analyzed the clock deviation for different devices in the network. The results of the evaluation revealed that the accuracy of the synchronized clock is affected by several factors such as the number of slave devices, period of drift compensation, and type of system time base. In particular, we found that careful decision regarding the system time base is required because it has a fundamental effect on the master operation, which results in significantly different performance characteristics.

A Study on the Structure and Origin of the Dokdo and it's Surroundings in the East Sea (Japan Sea) Using Magnetic Anomalies (지자기이상을 이용한 동해 독도 및 독도주변의 구조와 성인에 관한 고찰)

  • Kim, Chang-Hwan;Park, Chan-Hong;Min, Kyung-Duck;Han, Hyun-Chul;Kwon, Moon-Sang;Shim, Jae-Seol;Choi, Sung-Ho;Oh, Soon-Bock
    • Ocean and Polar Research
    • /
    • v.24 no.4
    • /
    • pp.491-500
    • /
    • 2002
  • Magnetic anomalies in the Dokdo and it's surroundings were investigated with respect to structure and origin of the Dokdo and surrounding seamounts. After normal and diurnal correction of measured magnetic data, crossover correction was applied to reduce errors between sets of magnetic anomalies. The errors from crossover operation result in decrease of about 51%, from 62.2 nT to 30.1 nT in standard deviation. Reduction-to-the-pole, second vertical derivative and analytic signal processing were applied to explore magnetic anomaly signatures in detail. Magnetic anomalies are most complicated in the 1st-Dok seamount, show SWW-NEE linear pattern in the 2nd-Dok seamount and lower to the 3rd-Dok seamount. Different magnetic anomaly patterns in three seamounts imply that three volcanic seamounts were formed at different times and are composed of rocks that were produced in different conditions. It seems that the 3rd-Dok seamount was first to form and followed by the 1st-Dok seamount. The complicated magnetic and second vertical derivative anomaly patterns in the 1st-Dok seamount may be due to subsidiary cones around crater or the presence of intruded magma bodies below sea surface and the Dokdo is probably a marginal subsidiary part of crater.