• Title/Summary/Keyword: Operation Deviation

Search Result 427, Processing Time 0.035 seconds

A Case Study of Evaluation for Lane Layout of Toll Plaza including Multi-lane ETCS (다차로 ETCS 도입 시 영업소 동선 처리 사례 연구)

  • Han, Dong-Hee;Choi, Yoon-Hyuk;Lee, Ki-Young;Jeong, So-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.3
    • /
    • pp.83-94
    • /
    • 2017
  • There is a two lane ECTS(Electronic Toll Collection System) that users can pass with 80kph high speed in SeoBusan Tall Gate. This system to be combined two hi-pass lanes for removing meddle-island have been operated successfully. But, the appearance of two Lane ETCS makes toll gate more complicated, so it is very important how to arrange effectively various tolling lanes. This study was trying to evaluate lane configuration for minimizing speed and speed deviation among all kinds of lanes including two Lane ETCS in seoul toll gate. That is, we selected all scenarios to be happened actually, and evaluated them using micro traffic simulation model (VISSIM). The results of this study showed that each alternative had a very different speed and speed deviation by lane each other, so we will be able to achieve effective operation and configuration of lanes in toll gate using scenario methodology.

Analysis of Monitored Insulation Data Using Standard Deviation of Leakage Current Data in High-Power Cables at a Thermoelectric Power Station (화력발전소 고전력 케이블의 누설 전류 측정 데이터의 표준 편차값을 사용한 절연감시 데이터 분석)

  • Kim, Bo-Kyeong;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.245-250
    • /
    • 2017
  • From the instant of installation and operation, power cables start deteriorating. Cable systems can be maintained not only by monitoring the insulation status of the insulation layer and oversheath, but also the insulation status of the terminal and junction in high-voltage power cables. When the cable system (the cable itself and cable junctions combined) deteriorates, fire accidents happen due to dielectric breakdowns. We have invented a device to monitor the deteriorating status of cables, and installed it at Korea Western Power Co. Ltd. located in Taean, Chungcheongnam-do Province. In this paper, we present the results obtained using our device, through analysing and calculating the standard deviation of leakage current from cable insulators attached to the cables. When the standard deviation of analysed leakage current falls below a critical value, a cable system is deemed to be operating safely. But when the standard deviation of analysed leakage current is larger than the critical value, the insulation status of the terminal and junction in the cable system is considered to have seriously deteriorated. The terminal and junction in the relevant system should then be replaced preemptively in order to prevent blackout accidents of cables caused by the suspension of power supply.

A Study on the Factors of Operational Publicness of Child Care Centers (어린이집 운영의 공공성에 영향을 미치는 요인)

  • Yang, Mi Sun
    • Korean Journal of Childcare and Education
    • /
    • v.10 no.3
    • /
    • pp.31-46
    • /
    • 2014
  • The purpose of this study is to analyze publicness by the types of childcare centers, and factors related to publicness in the operation of childcare centers. The subjects of this study were 511 childcare centers. Data were analyzed by frequency, percentage, mean, standard deviation, F-test, Duncan's post hoc test, and regression. The findings of the study were: First, Among childcare centers, Public childcare centers were high in universality, transparency and participation. But family daycare homes and private centers were low in universality, transparency, participation, and openness. Second, public childcare centers, family daycare homes, private childcare centers, major city and medium-sized cities affected universality in the operation of childcare centers. Public childcare centers, social welfare foundation childcare centers, family daycare homes, private childcare centers and proportion of capacity affected transparency in the operation of childcare centers. Public childcare centers, family daycare homes, private childcare centers and proportion of capacity affected participation in the operation of childcare centers. Government able to accomplish publicness in the operation of childcare centers if it would strengthen management process and expanded financial for childcare centers.

Consumed-Power and Load Characteristics of Potato Harvesting Operation in Dry Field (건답에서 감자수확작업의 소요동력 및 부하특성)

  • Lee, Ju-Yeon;Hwang, Seok-Joon;Nam, Ju-Seok;Kim, Jeong-Gil
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.1
    • /
    • pp.89-99
    • /
    • 2020
  • This study analyzed the load and the consumed power characteristics of a potato harvesting operation in a dry field. The potato harvesting operation was performed using an underground crop harvester mounted on an agricultural tractor with a rated engine power of 23.7 kW. The rotational speeds and the torque of the engine output shaft, rear axle, and power take-off (PTO) shaft were measured under various working conditions. The load spectrum and the consumed power were analyzed using the measured data. The results show that the consumed power of the rear axle increased as the working speed increased, while that of the PTO shaft decreased. The consumed power of the engine output shaft showed a similar trend with that of the PTO shaft, but the torque deviation was larger in the load spectrum. The results of previous studies were used to compare herein the consumed power and the load characteristics of the harvesting, rotary, and plow operations in a dry field. PTO and tractive power were highly consumed in the plow and rotary operations, respectively. The consumed power of the PTO shaft and the rear axle in the harvesting operation were 29-41% and 18-23% of the engine power, respectively. Compared to those in the rotary and plow operations, the engine power was relatively evenly distributed to the PTO shaft and rear axle in the harvesting operation.

Virtual Prototyping of Automated System for Adjustable Row Spacing of Hydroponic Gullies in Multilayer Plant Factory

  • Ashtiani-Araghi, Alireza;Lee, Chungu;Cho, Seong-In;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • v.40 no.1
    • /
    • pp.35-46
    • /
    • 2015
  • Purpose: To present a flexible and accurate autonomous solution for creating any desired row spacing value between the hydroponic gullies in multilayer growing units, and evaluate the capabilities and performance of the relevant automated system through the use of virtual prototyping technique. Methods: To build the virtual prototype of the system, CAD models of its different parts, including an autonomous vehicle and the mechanical mechanisms embedded in the multilayer growing unit, were developed and imported into the RecurDyn simulation software. In order to implement the automated row spacing operation, three spacing modes with different loading cycles and working steps were defined, and the operation of the system was simulated to obtain the target row spacing values specified for each of these modes. Results: Motion profiles related to the horizontal displacement of: 1) the lower and upper sliding bars installed in the cultivation layers, and 2) the hydroponic gullies, during the simulation of the system operation, were generated and analyzed. No deviation from the specified target spacing values was observed at the end of simulations for all spacing modes. Conclusions: The results of the motion analysis obtained by simulating the system operation confirm the effectiveness of the control scheme proposed for automated row spacing of gullies. It was also found that proper sequencing of the loading cycles and the precision of the working strokes of the upper bars are the critical factors for establishing a certain row spacing value. Based on the simulation results, precise control of the back and forth motions of the upper bars is highly necessary for sound operation of the real system.

Study on the Optimum Route Travel Time for Bus to Improve Bus Schedule Reliability (정시성 확보를 위한 버스노선 당 적정 운행시간 산정 연구)

  • Kim, Min ju;Lee, Young ihn
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.6
    • /
    • pp.112-123
    • /
    • 2017
  • The accurate forecasting of the public transportation's transit and arrival time has become increasingly important as more people use buses and subways instead of personal vehicles under the government's public transportation promotion policy. Using bus management system (BMS) data, which provide information on the real-time bus location, operation interval, and operation history, it is now possible to analyze the bus schedule reliability. However, the punctuality should always be considered together with the operation safety. Therefore, this study suggests a new methodology to secure both reliability and safety using the BMS data. Unlike other studies, we calculated the bus travel time between two bus stops by dividing the total travel length into 6 sections using 5 different measuring points. In addition, the optimal travel time for each bus route was proposed by analyzing the mean, standard deviation and coefficient of variation of the each section's measurement. This will ensure the reliability, safety and mobility of the bus operation.

Optimal Reservoir Operation Using Goal Programming for Flood Season (Goal Programming을 이용한 홍수기 저수지 최적 운영)

  • Kim, Hye-Jin;Ahn, Jae-Hwang;Choi, Chang-Won;Yi, Jae-Eung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.147-156
    • /
    • 2011
  • The purpose of multipurpose reservoir operation in flood season is to reduce the peak flood at a control point by utilizing flood control storage or to minimize flood damage by controlling release and release time. Therefore, the most important thing in reservoir operation for flood season is to determine the optimal release and release time. In this study, goal programming is used for the optimal reservoir operation in flood season. The goal programming minimizes a sum of deviation from the target value using linear programming or nonlinear programming to obtain the optimal alternative for the problem with more than two objectives. To analyze the applicability of goal programming, the historical storm data are utilized. The goal programming is applied to the reservoir system operation as well as single reservoir operation. Chungju reservoir is selected for single reservoir operation and Andong and Imha reservoirs are selected for reservoir system operation. The result of goal programming is compared with that of HEC-5. As a result, it was found that goal programming could maintain the reservoir level within flood control level at the end of a flood season and also maintain flood discharge within a design flood at a control point for each time step. The goal programming operation is different from the real operation in the sense that all inflows are assumed to be given in advance. However, flood at a control point can be reduced by calculating the optimal release and optimal release time using suitable constraints and flood forecasting system.

Shoulder Range of Motion in Postmastectomy Patients (유방암 절제술 후 환자의 어깨관절 가동범위 조사)

  • Eom, Ae-Yong;Lee, Eun-Ok
    • Asian Oncology Nursing
    • /
    • v.4 no.1
    • /
    • pp.62-70
    • /
    • 2004
  • The purpose of this study was to use as a basic data to develop suitable nursing intervention program and decide an appropriate intervention time after assessing shoulder range of motion in postmastectomy from 2 weeks to 3 month. 147 patients are chosen as study subject among patients who were in recovery of 2weeks, 1month, 2months and 3 months after surgical operation which is modified radical mastectomy. Data were collected at oncology medicine local and general surgery local in Seoul National University Hospital from May, 2003 to October, 2003. The range of motion of the shoulder(flexion, extension, abduction, internal rotation, external rotation) were examined. Analysis of data that shoulder range of motion average and standard deviation, percentage of the unaffected side and affected side compare with normal shoulder range of motion. Paired t-test was adopted to analyze the difference between affected side and unaffected side. Conclusion from this study is as following, 1. The most serious problem was external rotation (0.56%) and internal rotation is the next (19.9%) in 5 kinds of shoulder range of motion in 2 weeks after surgical operation 2. There was no difference in internal rotation after post operation 3 months but there were differences and shown to recover more than 90% in flexion and abduction. Also shoulder function incresed in flextion less than 80% and more than 80% in external rotation. As this study finding was shown that shoulder range of motion did not get back perfectly except of internal rotation and extension in point of 3 months after breast cancer surgical operation. External rotation was specially shown the lowest result so it is needed to exercise for improving their physical functioning recovery in postmastectomy patients. And it is suggested to study for helping to postmastectomy patients' physical and psycosocial functions with the early rehabilitation program which is based on these results.

  • PDF

A Study on the Electrocardiographic Change after the Senning Operation for Transposition of the Great Arteries (Senning씨 술식에 의해 교정한 완전 대혈관전위증에서의 심전도 변화에 관한 연구)

  • Kim, Gi-Bong;No, Jun-Ryang
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.623-634
    • /
    • 1985
  • One of the most widely recognized problems in patients with TGA [transposition of the great arteries] after the Senning operation is the occurrence of arrhythmias. From June 1982 through October 1984, 22 patients, 11 with "simple" and 11 with "complex" TGA, underwent correction of TGA by a modification of the Senning operation designed to avoid dysrhythmias. 16 were males and 6 females, with ages ranging from 3 months to 27 months. [mean age 10.8 months] 7 patients [31.8%], 1 with simple TCA and 6 with complex TGA, died in the early post-operative period. The operative mortality was 9.1% in "simple" TGA, and 54.9% in "complex" TGA. There were 4 late deaths but only one of these patients died of a dysrhythmia as a possible factor. The standard ECG [Electrocardiography] checked preoperatively showed sinus rhythm in 17 [77.3%], 1 AV block in 5 [22.7%]. In 22 patients studied postoperative 1st day, the incidence of arrhythmias was 63.6%, with significant incidence compared with preoperative study. [P<0.05]. But, in 15 patients studied postoperatively at intervals from 1 month to 26 months, the incidence of arrhythmias was 26.7%, with no significant incidence compared with preoperative study [P>0.1]. Our results indicate that a modified Senning operation may reduce the frequency of surgically induced arrhythmias. The mean frontal plane P-wave axis also revealed significant deviation to the right side [P<0.05], compared with preoperative study. These findings raise the possibility that what has been called sinus rhythm postoperatively may have a different origin and conduction sequence from normal. But the rhythm seems to be functionally similar.rhythm seems to be functionally similar.

  • PDF

A study on the change of air lead concentrations in lead-acid battery plants (축전지 사업장에서 공기 중 납 농도의 변화에 관한 연구)

  • Choi, Seung-Hyun;Kim, Nam-Soo;Kim, Jin-Ho;Cho, Kwang-Sung;Ham, Jung-O;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.4
    • /
    • pp.261-271
    • /
    • 2007
  • To provide necessary information for future environmental monitoring of storage batteries in Korea, authors analyzed environmental monitoring dataset of air lead concentration of 12 storage battery industries measured during 1989-2006. We calculated geometric mean and standard deviation with minimum and maximum value of each year dataset. Air lead concentration data were analyzed according to year of measurement, type of grid manufacturing method (grid casting type or expander type), size of industries and type of operation (casting, lead powder & pasting, assembly and others). The geometric mean and standard deviation of all lead industries for overall 18 years were $72{\mu}g/m^3$ and 3.65 with minimum of $6{\mu}g/m^3$ and maximum of $7,956{\mu}g/m^3$. The geometric mean air lead concentrations of years between 1989-1999 were above the Korean PEL($50{\mu}g/m^3$), whereas those of years after year 2000 were below the Korean PEL showing 50% of it. The geometric mean concentration of air lead was significantly lower in expander method battery industries than that of grid method battery industries and was lower in large sized battery industries than small & medium sized ones throughout the whole 18 years period. The distributions of over PEL($50{\mu}g/m^3$) were decreased by the years of environmental monitoring and those were lower in expander method battery industries than grid method battery industries. The significant reduction of mean air lead concentration during last 10 years may be induced partly due to more active environmental engineering control and new introduction of new operation in grid method battery industries, but may be also influenced by non-engineering method such as reduction of operation hours or reduction of exposure time during actual environmental measurement by industrial hygienist which is not concrete evidence, but just circumstantial evidence.