• Title/Summary/Keyword: Operation Department

Search Result 13,787, Processing Time 0.038 seconds

Five-level Inverter for Excitation Control of SRM Drive

  • Oh, Seok-Gyu;Park, Sung-Jun;Ahn, Jin-Woo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.3
    • /
    • pp.64-69
    • /
    • 2001
  • Energy recovery in the regenerative region is very important when SRM is used in traction drive, This is to reduce en-ergy loss during mechanical braking and/or to have a high efficiency drive during braking To control excitation voltage in motor operation and regenerative voltage in the generator operation in the SRM multi-level voltage control is effective The paper sug-gests multi-level inverter which is useful for motoring and regenerative operation in SRM

Subdivision of Certain Barbell Operation of Origami Graphs has Locating-Chromatic Number Five

  • Irawan, Agus;Asmiati, Asmiati;Zakaria, La;Muludi, Kurnia;Utami, Bernadhita Herindri Samodra
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.9
    • /
    • pp.79-85
    • /
    • 2021
  • The locating-chromatic number denote by 𝛘𝐿(G), is the smallest t such that G has a locating t-coloring. In this research, we determined locating-chromatic number for subdivision of certain barbell operation of origami graphs.

Inner Automorphisms of an Abelian Extension of a Quandle

  • Yongju Bae;Byeorhi Kim
    • Kyungpook Mathematical Journal
    • /
    • v.63 no.4
    • /
    • pp.709-718
    • /
    • 2023
  • The inner automorphism groups of quandles are related to the classification problem of quandles. The inner automorphism group of a quandle is generated by inner automorphisms which are presented by columns in the operation table of the quandle. In this paper, we describe inner automorphisms of an abelian extension of a quandle by expressing columns of the operation table of the extended quandle as columns of the operation table of the original quandle. Such a description will be helpful in studying inner automorphism groups of abelian extensions of quandles.

A Microgrid Operation based on a Power Market Environment

  • Kim, Hak-Man;Kinoshita, Tetsuo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.61-68
    • /
    • 2009
  • A Microgrid is a private small-scale power system composed of distributed energy resources (DERs), storage devices and loads. And it is expected that the Microgrid will come into wide use in the near future. For this, the establishment of the Microgrid operation methodology is a very important problem. Especially, the Microgrid is greatly different from existing private small-scale power systems because of the multiple participants. Therefore, the Microgrid operation considered various requirements according to multiple participants is more complicated than the operation of existing private small-scale power systems. In this paper, Microgrid operation methodology based on a market environment is suggested. Through case studies, the effectiveness of the suggested methodology is verified.

One-stage Repair of Neonatal Hirschsprung's Disease (신생아기 일기식 방법으로 수술한 Hirschsprung병에 대한 고찰)

  • Rhim, Si-Youn;Jung, Poong-Man
    • Advances in pediatric surgery
    • /
    • v.13 no.1
    • /
    • pp.61-65
    • /
    • 2007
  • Conventional treatment of Hirschsprung's disease consists of initial colostomy followed by pull-through operation. But, the treatment of Hirschsprung's disease has been changed along with the development of new surgical technique. Since 1995, endo-GIA has been available at our hospital and one stage Duhamel operation has been performed for neonatal Hirschsprung's disease. Between May 1995 and April 2006, 26 neonates have been treated with one stage pull-through operation by one pediatric surgeon at HanYang University Hospital. The sex ratio was 4.2:1 with male predominance. Clinical findings included abdominal distension (96.2 %), vomiting (50.0 %), delayed passage of meconium (46.2 %), constipation (23.1 %), and enterocolitis (15.4 %). Twenty two cases (84.6 %) were short-segment and 4 cases (15.4 %) were long-segment disease, of which 2 cases were total colon aganglionosis. One of the two patients with total colonic aganglionosis had double transition zones - distal ileum and hepatic flexure of the colon. The average age at operation was $14.56{\pm}8.77$ days and the average weight at operation was $3.26{\pm}0.66kg$. Primary Duhamel operations were performed in 25 patients and Soave-Boley operations was performed in one patient. The endo-GIA 35 (Ethicon, USA) was used from 1995 until 1997, and after that endo-GIA 60 (USSC, USA) was used. The average Duhamel operation time was $88.57{\pm}22.80$ minutes. Wound abscess (n = 2) and septum formation (n =1) occurred after Duhamel operation. Bowel function was normalized in 59 % within 3 months and in 95% within 1 year after operation. There was no mortality after one stage pull-through operation in neonate.

  • PDF

A Study on the Optimal Control Algorithms for the Advanced Wastewater Treatment Process with Variable Hydrodynamic Flow Patterns (유로 변경식 고도하수처리 공정의 최적 제어 알고리즘에 관한 연구)

  • Kang, Seong-Wook;Cho, Wook-Sang;Huh, Hyung-Woo
    • Applied Chemistry for Engineering
    • /
    • v.16 no.2
    • /
    • pp.217-225
    • /
    • 2005
  • Because of the limitation of controllable operation variables for the wastewater treatment process with variable hydrodynamic flow patterns, it may preclude the use of this type of nutrient removal activated sludge process. As the operation variables, only temperature and dissolved oxygen (DO) have been used to operate the process. This study made an effort to improve treatment efficiency and operability of the process by the following methodologies: 1) process and operation data analysis using process simulation, 2) determination of optimal control logic or algorithm using a pilot-scaled experimental apparatus and its operations, and 3) application of experimental and simulation results to find the optimal process operation modes. In this study, it was found that the optimal operation mode named 'save mode' in the basis of process variables, such as the ammonia-nitrogen concentration of inlet flow, temperature and flow rate, can reduce the operation cost comparing with the present normal operation mode. And the stable conditions in nitrification were also shown by the proportional control of DO with the inlet air flow rate of blower and the mixing rate of mechanical aeration.

A Study on Integrated Operation of School Bus in Suburbs (교외지역 통학버스 통합 운영 방안 연구)

  • Ko, Young Dae;Oh, Yonghui
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.4
    • /
    • pp.899-910
    • /
    • 2018
  • Purpose: Generally, since the population density is lower in suburban areas, the distance to school is inevitably long. Therefore, schools in suburban areas often operate school buses to improve student welfare. However, since school buses are usually used only during going to and from school, the utilization rates are relatively low. Therefore, this study aims to establish integrated operation plan of public school bus covering all schools. Methods: It is necessary to decide which school buses will serve the specific demand node which want to go to certain school in order to design an integrated operation plan for school buses. Therefore, a mathematical model is developed for minimizing the total number of vehicles and the distance of transportation by reflecting the characteristics of school buses and students as constraints. To solve the proposed mathematical model, CPLEX, a commercial solver, is applied. Results: To validate and to confirm the proposed process, numerical example is designed with the comparison between before and after integrated operations of school buses in terms of total operation cost. The result shows that the integrated operation can lead the reduction of the number of school buses as well as the decreasing of the fuel cost. Conclusion: This study provides the quantitative method to perform the integrated operation of school buses in suburban areas. The optimal operation strategy is required because there are more complex decision-making elements considering the integrated operation. It is expected to apply this research result at real situation to expand this services based on an optimal operation.

Hydrothermal Synthesis of Fe Based MOFs with Energy Economy Approach

  • Israr, Farrukh;Kim, Duk Kyung;Kim, Yeongmin;Oh, Seung Jin;Ng, Kim Choon;Chun, Wongee
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.55-58
    • /
    • 2015
  • The mesoporous metal organic framework structure Fe-BTC was successfully synthesized by hydrothermal process with noticeable yield. The synthesis operation was conducted at intermediate temperature and for shortened operation time as compared to conventional procedures. This process approach with reduced operating temperature and shortened operation time may open an opportunity window towards process economy with reduction in energy consumption. A simple mathematical approach of diffraction indexing using X-ray diffraction patterns of synthesized powder was employed to confirm its crystalline nature and to investigate its high temperature stability. The crystallite size was calculated by using Debye-Scherrer equation.

Optimization of Operation Frequency of Orthogonal Fluxgate Sensor Fabricated with Co Based Amorphous Wire

  • Kim, Young-Hak;Kim, Yongmin;Yang, Chang-Seob;Shin, Kwang-Ho
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.159-162
    • /
    • 2013
  • We present how to optimize the operation condition including frequency of the orthogonal fluxgate sensor in this paper. The orthogonal fluxgate sensor was fabricated with a Co-based amorphous wire with 10 mm long and 100 ${\mu}m$ in the diameter and a 270-turn pickup coil wound on the amorphous wire. In order to investigate the frequency dependence of the sensitivity, output spectra of the sensor which was connected by using a coaxial cable with various lengths of 0.5-5 m were measured with a RF lock-in amplifier. The maximum sensitivities were obtained at different frequencies according to coaxial cable lengths. It was found that the optimal operation frequencies, at which maximum sensitivities were appeared, were almost identical to the frequencies of impedance resonance. The maximum sensitivity and optimal operation frequency were 1.1 V/Oe (${\approx}$ 11000 V/T) and 1.25 MHz respectively.