• Title/Summary/Keyword: Operation Conditions

검색결과 4,636건 처리시간 0.035초

인산제조공정의 모사연구 (An Intelligent Simulation of a Phosphoric Acid Plant)

  • 여영구
    • 한국시뮬레이션학회논문지
    • /
    • 제3권1호
    • /
    • pp.167-178
    • /
    • 1994
  • For the identification of the optimal operating conditions of phosphoric acid plant, an intelligent simulation was performed based on the dissolution reaction of phosphate rock. A phosphoric acid plant consists of three main processes : ball-mill grinding process, rock reaction process and slurry filteration process. The grinding and filteration processes are relatively simple processes and most of the simulation works are on the reaction process. The practical operation data of phosphoric acid plant at Namhae Chemical Corp. were utilized in the simulation. The operation of the phosphoric acid plant is highly dependent on the heuristics of operators and so the expert system technology was employed. The operation of phosphoric acid plant varies with the origin of phosphate rock. Results of the simulation showed the optimal values of major process variables and optimal operating conditions. The knowledgebase for the expert system was constructed based on the interview with the experienced plant operators.

  • PDF

Effect of Biofilter Operation Parameters on Dimethyl Disulfide Removal : Loading, Time, and Concentration

  • Arpacioglu, Bora C.;Kim, Jo-Chun;Allen, Eric R.;Kim, Seoung-Hyun
    • 한국환경과학회지
    • /
    • 제11권8호
    • /
    • pp.783-791
    • /
    • 2002
  • A laboratory-scale dual-column biofilter system was used to study the biofiltration of dimethyl disulfide(DMDS). The biofiltration of DMDS was found to depend on the pollutant loadings rather than the inlet concentrations. It was estimated that the pollutant was only inhibitory to the operation of the biofilters at DMDS concentrations greater than 5500 ppmv A residence time of 30 seconds(120 m$^3$/m$^2$/h volumetric loading) was determined as appropriate for efficient operation(>90%). The maximum elimination capacity for both compost mixtures under the current experimental conditions was found to range from 7.5 to 10 g-DMDS/m$^3$/h. A lower DMDS maximum elimination capacity was exhibited under acidified conditions.

복합화력 발전용 재열사이클 가스터빈의 운전상태 분석 (Analysis of Operation Conditions of a Reheat Cycle Gas Turbine for a Combined Cycle Power Plant)

  • 윤수형;정대환;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제9권6호
    • /
    • pp.35-44
    • /
    • 2006
  • Operation conditions of a reheat cycle gas turbine for a combined cycle power plant was analyzed. Based on measured performance parameters of the gas turbine, a performance analysis program predicted component characteristic parameters such as compressor air flow, compressor efficiency, efficiencies of both the high and low pressure turbines, and coolant flows. The predicted air flow and its variation with the inlet guide vane setting were sufficiently accurate. The compressor running characteristic in terms of the relations between air flow, pressure ratio and efficiency was presented. The variations of the efficiencies of both the high and low pressure turbines were also presented. Almost constant flow functions of both turbines were predicted. The current methodology and obtained data can be utilized for performance diagnosis.

Injection of Waste Plastics into the Blast Furnace and Its Effect on Furnace Conditions

  • Heo, Nam-Hwan;Baek, Chan-Yeong;Yim, Chang-Hee
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.755-758
    • /
    • 2001
  • Most of the waste plastics are incinerated and landfilled now, leading to much environmental problems. The technology of injection into the blast furnace was developed as a useful recycling method of waste plastics, and applied to the actual operation in several ironmaking companies. We carried out the test operation to inject continuously the two kinds of waste plastics through four tuyeres of the Foundry blast furnace in POSCO by 130 ton of total amount. From this test operation, we analyzed the coke replacement ratio, the permeability, the heat load and other changes of furnace conditions with the injection of waste plastics into the blast furnace. Some trials based upon the theoretical approaches were applied to examine the efficiencies of blast furnace.

  • PDF

SONOS two-bit 메모리의 측면확산에 영향을 주는 programming 조건 연구 (A study on the programming conditions suppressing the lateral diffusion of charges for the SONOS two-bit memory)

  • 이명식;안호명;서광열;고중혁;김병철;김주연
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.117-120
    • /
    • 2005
  • The SONOS devices have been fabricated by the conventional $0.35{\mu}m$ complementary metal-oxide-semiconductor (CMOS) process with NOR array. Two-bit operation using conventional process achieve the high density memory compare with other two-bit memory. Lateral diffusion phenomenon in the two-bit operation cause soft error in the memory. In this study, the programming conditions arc investigated in order to reduce lateral diffusion for two-bit operation of CSL-NOR type SONOS flash cell.

  • PDF

발전소 운전 중 증기터빈 밸브 시험 방식 소개 (An Introduction to Test Methods about Steam Valves of Steam Turbines in Power Plants)

  • 최인규;우주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1601-1602
    • /
    • 2007
  • Steam stop valves of steam turbine in the power plant are at their 100% position and have no movements. Steam control valves, ie governor valves have no movements either at their controlling position on load limit operation. By the way, if there were no change of operation state, steam valves could be sticked mechanically. Because the governor could fail in protecting and controlling steam turbine in case of emergency conditions, the closing test of 100% valve travel must be accomplished periodically for the purpose of testimony of their good conditions. And, As the difference between steam turbine structures exists according to the manufacturer or generation capacity, both steam stop valves and steam control valves differes in structure and operation method. Therefore, it is essential for not only turbine protection but also control for the control engineers to find out composition of steam valves and method of closing test.

  • PDF

송전선로의 설비특성을 고려한 운영그룹 분류 및 최고허용온도 (An Operation Grouping and Its Maximum Allowable Conductor Temperature Considering Facility-conditions of Transmission Lines)

  • 손홍관;김병걸;박인표;안상현;장태인;최종기
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1922-1928
    • /
    • 2008
  • The thermal rating of a conductor are maximum continuous current capacity and short time emergency current capacity. The overload operation for a faults have an effect on a conductor lifetime. Its time duration and overload level are limited to facility conditions of transmission lines. The short time emergency current capacity in KOREA observe the KEPCO's DESIGN RULE 1210, but its rules are not included to concept of an allowable short time duration. This papers are described to the calculation concept of short time emergency current capacity considering a time duration and an overload level. And we suggested a operation grouping and its maximum conductor temperature considering facility conditions - conductor lifetime, stability of connection points, conductor height above ground and clearance, in the operating and new T/L.

여름철 공조시스템의 최적 운전 제어 방식 (Optimal air-conditioning system operating control strategies in summer)

  • 허정호
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.410-425
    • /
    • 1997
  • Buildings are mostly under part load conditions causing an inefficient system operation in terms of energy consumption. It is critical to operate building air-conditioning system with a scientific or optimal manner which minimizes energy consumption and maintains thermal comfort by matching building sensible and latent loads. Little research has been performed in developing general methodologies for the optimal operation of air-conditioning system. Based on this research motivation, system simulation program was developed by adopting various equipment operating strategies which are energy efficient especially for humidity control in summer. A numerical optimization technique was utilized to search optimal solution for multi-independent variables and then linked to the developed system simulation model within a mam program. The main goal of the study is to provide a systematic framework and guideline for the optimal operation of air-conditioning system focusing on air-side. For given cooling loads and ambient outdoor conditions the optimal operating strategies of a commercial building are determined by minimizing a constrained objective function by a nonlinear programming technique. Desired space setpoint conditions were found through evaluating the trade-offs between comfort and system power consumption. The results show that supply airflow rate and compressor fraction play main roles in the optimization process. It was found that variable setpoint optimization technique could produce lower indoor humidity level demanding less power consumption which will be benefits for building applications of humidity problem.

  • PDF

실험계획법을 이용한 전자부품 위치정렬장치 최적 운영조건 사례연구 (A Study on Optimal Operation Conditions for an Electronic Device Alignment System by Using Design of Experiments)

  • 이동헌;이미림;배석주
    • 품질경영학회지
    • /
    • 제43권3호
    • /
    • pp.453-466
    • /
    • 2015
  • Purpose: The purpose of this study is to design a systematic method to estimate optimal operation conditions of design variables for an electronic device alignment system. Method: The 2-level factorial design and the central composite design are used in order to plan experiments. Based on the experiment results, a regression model is established to find optimal conditions for the design variables. Results: 3 of 5 design variables are selected as major factors that affect the alignment system significantly. The optimized condition for each variable is estimated by using a sequential experiment plan and a quadratic regression model. Conclusion: The method designed in this study provides an efficient and systematic plan to select the optimized operation condition for the design variables. The method is expected to improve inspection accuracy of the system and reduce the development cost and period.

Induction Motor with Adjustable Windings for High Efficiency Drive in Light Load Operation

  • Zhang, Y.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.508-513
    • /
    • 2014
  • Heavy load start but light load operation is a common case in practical drive applications. When an induction motor is employed for such applications, its rated power is usually chosen according to the heavy load start. Then, during light load operation, its efficiency and power factor are low. To solve this problem, it is proposed to adjust the motor windings from the startup to the normal operation conditions. In this paper, arrangement of the adjustable windings is introduced, air gap field with different windings is investigated, and steady state operation performance under various loads is examined. It can be seen that by using proper winding arrangement both startup and operation performances are satisfactory.