• 제목/요약/키워드: Operation Characteristics

검색결과 7,644건 처리시간 0.032초

탈색단계별 과산화수소 농도에 따른 모발의 물리.형태적 손상정도 비교 (The Comparison of Physical & Morphological Damage of Hair According to the Bleaching Methods by the $H_2O_2$ Concentration)

  • 이은경;황중덕;김혜정
    • 한국패션뷰티학회지
    • /
    • 제5권1호
    • /
    • pp.71-77
    • /
    • 2007
  • This study attempted to comparative analysis about the physical and morphological damage degrees of hair according to the bleaching methods by $H_2O_2$ concentration. As a result of the changes in the physical characteristics of the hair according to the deceleration operation methods by 3-6-9% and 9% $H_2O_2$ concentration, the intensity of tension considerably decreased but the elongation was increased. And the more the damage of hair, the larger the degree of change. Regarding the method of deceleration operation, the 3-6-9% deceleration operation method was more damaging than the 9% single deceleration operation method. In the change of the characteristics of the form of the hair, the control group of the 5-level deceleration hair generally showed a smooth external appearance and regular and closely overlapped epidermis and undamaged cuticle were observed. But in the 3-6-9% deceleration operation method and 9% single deceleration operation method, damages such as the irregular form of the edge of the epidermis and the unclear boundary between the epidermis occurred.

  • PDF

천리안위성 정규 운영에 대한 임무계획 특성 (Characteristics of the Mission Planning for COMS Normal Operation)

  • 조영민;조혜영
    • 항공우주기술
    • /
    • 제12권2호
    • /
    • pp.163-172
    • /
    • 2013
  • 통신, 해양, 기상의 세 분야 복합 임무를 수행하는 천리안위성(Communication Ocean Meteorological Satellite: COMS)은 정지궤도 동경 $128.2^{\circ}$에서 2011년 4월부터 현재 정규 운영 임무를 수행하고 있다. 기상 및 해양 임무 운영과 위성 제어 및 관리를 위해 위성 임무 계획이 매일 수행되고 있다. 위성 임무 계획은 위성 실시간 운영을 통해 위성에 전송되고, 전송된 임무 계획에 따라 위성은 임무를 수행한다. 본 논문에서는 천리안위성의 임무 계획 특성으로 지상국 장비 구성과 일일, 주간, 월간, 계절별 운영 업무 특성을 논하였다. 천리안위성의 정규 운영 첫 1년간 운영 결과에 대한 토의를 통해 성공적인 임무계획 결과 확인도 제시하였다.

항타공법에 의한 발생 소음 특성 분석 및 축소 모형 실험을 이용한 저소음 말뚝 캡의 설계 (Investigation on Noise Characteristics of Pile Driving Operation and Design of a Low-noise Pile Cap Based on the Scale Model Experiment)

  • 이종화;이정권;이기홍;정승창
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.445-448
    • /
    • 2001
  • Noise radiated from pile driving operation is one of major sources of community noise pollution and thus its operation method is strictly restricted by regulations. Although the drilling method is now used been commonly used in urban areas because of its activity, the benefit of low noise decreases due to high working cost. In the present work, noise characteristics of pile driving operation are carried out. Based on the study result, a low-noise pile cap for driven piles is developed in order to satisfy both the noise level restriction and the economical efficiency. Effects of pile cap are investigated by a scale model experiment, which is focused on the variation of impact force and sound pressure level. The results show a good possibility of noise reduction by an appropriately designed pile cap.

  • PDF

고속철도 차륜답면의 마모 특성에 관한 연구 (A Study on the Wear Characteristics of Wheel Profile for High Speed Rolling-stock)

  • 허현무;유원희
    • 한국철도학회논문집
    • /
    • 제8권5호
    • /
    • pp.477-482
    • /
    • 2005
  • Through a year's commercial operation, Korea High Speed Railway has solved defectives from several breakages at the beginning and is going into the stage of stable operation. Among issues, wheel wear becomes a matter of primary concerns in view of vehicle's stability and maintenance. It was understood as above that wear status has been improved in the test by which railway system including vehicles and tracks was stabilized during a year's commercial operation, comparing to that with excessive wear in the trial operation prior to opening to the public. To make out wheel's wear status and characteristics of equivalent conicity at present when the service has been introduced a year ago and the average cumulative mileage of vehicles reach almost 500,000km, wheel's wear types were analyzed with the current vehicles in service.

A Comparative Study of Operation Characteristics of Active Clamp Forward Converter Based on Loss analysis

  • Oh, Deog-Jin;Kim, Hee-Jun
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.636-641
    • /
    • 1998
  • In this paper, operation characteristics of the Zero-voltage-Switching(ZVS) mode and Non-Zero-Voltage-Switching (NZVS) mode of the active clamp (ACL) forward converter are compared through the loss analysis. The losses of semiconductor devices, transformer and passive elements of the converter are analyzed and compared for each type of operation mode. In order to verify the validity of the analysis, we have built a 50W ACL forward converter and measured the losses of the converter. From the experiment it is known that the ACL forward converter shows nearly same loss distribution for both of operation modes

  • PDF

증기분사에 의한 가스터빈 열병합발전 시스템의 성능과 운전조건 변화 - 압축기 작동 변화를 중심으로 (Changes in Performance and Operating Condition of a Gas Turbine Combined Heat and Power System by Steam Injection - A Focus on Compressor Operation)

  • 강수영;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제14권6호
    • /
    • pp.68-75
    • /
    • 2011
  • This study simulated the effect of steam injection on the performance and operation of a gas turbine combined heat and power (CHP) system. A commercial simple cycle gas turbine was analyzed. A full off-design analysis was carried out to investigate the variations in not only engine performance but also the operating characteristics of the compressor caused by steam injection. Variation in engine performance and operation characteristics according to various operation modes were examined. First, the impact of full steam injection was investigated. Then, operations aiming to guarantee a minimum compressor surge margin, such as under-firing and partial steam injection, were investigated. The former and latter were turned out to be relatively superior to each other in terms of power and efficiency, respectively.

마이크로 가스터빈의 탈설계 운전 성능특성 (Performance Characteristics for Off-design Operation of Micro Gas Turbines)

  • 황성훈;김동섭
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.80-87
    • /
    • 2003
  • Micro gas turbines are designed with low turbine inlet temperature and pressure ratio. To overcome the efficiency defect of the simple cycle, adoption of the recuperator is an inevitable choice. In addition to the design performance, we should also pay attention to the off-design performance of gas turbines since they usually operate at part-load conditions for a considerable amount of the time. This study aims at analyzing off-design performance characteristics of micro gas turbines and addressing the importance of the recuperator in the part load operation. Comparative analyses have been performed to evaluate the part load performance differences among various design and operating options : simple vs recuperative cycles, single vs two shaft configurations, various operating strategies for the single shaft configuration (fuel only control, variable speed operation, variable inlet guide vane control), and current vs advanced engines. Major finding is that maintaining turbine at high level is crucial in efficient operation of micro gas turbines.

  • PDF

Steady-State Characteristics of Resonant Switched Capacitor Converters

  • Shoyama Masahito;Deriha Fumitoshi;Ninomiya Tamotsu
    • Journal of Power Electronics
    • /
    • 제5권3호
    • /
    • pp.206-211
    • /
    • 2005
  • Conventional switched capacitor converters have an inherent drawback that their efficiency decreases as the output current increases. This inherent drawback is due to a periodical forced charging and discharging operation in the internal switched capacitors accompanied by a large capacitor current. Their efficiency can not be increased by decreasing its internal resistance. As a result, conventional switched capacitor converters have been limited to uses with a very small output current. To solve this problem we presented a novel switched capacitor converter topology that uses a resonant operation instead of the forced charging and discharging operation. Its advantage over a conventional switched capacitor converter is higher efficiency even in a high output current region. In this paper, the operation analysis and steady-state characteristics are described in detail for a half buck type switched capacitor converter, and they are confirmed by experimentation.

테일팬 성능시험장치의 운용과 진동특성 (The Operation and Vibration Characteristics of Tail-Fan Performance Test System)

  • 송근웅;김준호;강희정;이욱;심정욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.508-512
    • /
    • 2004
  • This paper described operation and vibration characteristics of 'Tail-Fan' performance test system. KARI(Korea Aerospace Research Institute) developed 'Tail-Fan' system as a kind of helicopter anti-torque system(ATS) and designed ATS performance test-rig for Tail-Fan system performance test. Test-rig consists of driving parts, supporting parts and rotating parts. For Tail-Fan system performance tests, firstly, test-rig operation tests were carried out for verification of design specifications. Secondly, natural frequencies of fan blade and test-rig were measured respectively. Lastly, to find the operation rotating speed for performance tests, vibration tests using accelerometers on tail gear box(TGB) were carried out. Through the fanplot and vibration test results, Tail-Fan performance test conditions to avoid a resonance were found and performance tests were well done safely.

  • PDF

병렬운전 모델을 이용한 DC-DC 컨버터의 병렬운전 특성해석 (The Analysis of Parallel Operating Characteristics for DC-DC Converter Using the Parallel Operation Model)

  • 김수석
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.174-182
    • /
    • 2004
  • 높은 생산성, 시스템 설계의 단순화 및 미래 확장에 대비한 여분의 전원 확보 등의 병렬운전 방법의 장점으로 인해 대전력 전원장치에 있어 컨버터 시스템의 병렬운전에 대한 요구가 점점 증가되어 왔다. DC-DC 컨버터의 소신호 모델을 토대로 하여, 병렬운전 시스템의 모델을 제안하였으며 각 컨버터 모듈간의 균일한 전류분배를 위해 제안된 균등 전류 분배법을 사용한 병렬운전 시스템에 대하여 논의하였다. 모의실험 프로그램을 사용하여, 서로 특성이 다른 컨버터 모듈로 구성된 병렬운전 시스템에서 마스터와 슬레이브 모듈의 위치가 자동적으로 변하면서 전류분배 오차는 제한 값 이내로 유지됨을 확인하였다. 병렬운전을 위한 제안된 컨버터 시스템의 운전 특성을 확인하기 위하여 1[kW]의 DC-DC 컨버터 모듈 2대를 제작 실험하였으며 모의실험 결과는 과도특성 및 기동특성에 있어 실험 결과와 잘 일치됨을 확인하였다.