• 제목/요약/키워드: Operation Capacity

검색결과 2,148건 처리시간 0.024초

급행.완행 결합 운행에 따른 수송량 및 소비 에너지의 변화 (A Study on the Change of Energy Consumption and Transport Capacity Depending upon the Train Operation Mixing Slow Trains and Fast Trains)

  • 양경록;김재환;진인수;류형선;김시구;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1448-1450
    • /
    • 2000
  • The train system in a big city has the serious problem of the shortage of transport capacity. And because of the nowaday energy crisis, the research to reduce the energy consumption in the train system has been progressed. In this paper, it is expected that the train operation mixing slow trains and fast trains enable us to increase transport capacity and to reduce energy consumption. In this paper, the train operation mixing slew trains and fast trains is modelled and the change of energy consumption and transport capacity depending upon the operation formation is simulated.

  • PDF

송전선로의 설비특성을 고려한 운영그룹 분류 및 최고허용온도 (An Operation Grouping and Its Maximum Allowable Conductor Temperature Considering Facility-conditions of Transmission Lines)

  • 손홍관;김병걸;박인표;안상현;장태인;최종기
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.1922-1928
    • /
    • 2008
  • The thermal rating of a conductor are maximum continuous current capacity and short time emergency current capacity. The overload operation for a faults have an effect on a conductor lifetime. Its time duration and overload level are limited to facility conditions of transmission lines. The short time emergency current capacity in KOREA observe the KEPCO's DESIGN RULE 1210, but its rules are not included to concept of an allowable short time duration. This papers are described to the calculation concept of short time emergency current capacity considering a time duration and an overload level. And we suggested a operation grouping and its maximum conductor temperature considering facility conditions - conductor lifetime, stability of connection points, conductor height above ground and clearance, in the operating and new T/L.

지능형 고효율 철도물류터미널 구축 방안 (On the development of Intelligent Railway Logistics Terminal)

  • 김동희;홍순흠;김영훈;김경희;김경민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1596-1602
    • /
    • 2010
  • The government have plans to improve the railway transport capacity and transport hub for the sustainable national transport and logistics system. Specially, there are much efforts to improve transportation capacity such as high speed transportation of rail freight, enlargement of BT train, development of double stack train, etc. between railway transport hubs. If the transport capacity between railway logistics hubs is increased as planned, we must increase the handling capacity of railway hub terminals. But there are limits to enlarge the terminal infrastructure because of investment scale, location circumstances and urban development plans. To ensure the capacity, with the minimum required enlargement of infrastructure, it is necessary to extremely increase the efficiency of terminal operations. For improving the efficiency, we have to introduce the efficient terminal operation systems based on u-IT and operation optimize technologies. In this paper, we analyse the issues and problems of railway terminals(including ICD) and suggest the concept of intelligent railway terminal and the construction components of technology.

  • PDF

빙축열시스템의 실질적인 최대 축열 가능량 예측 (Prediction of practically chargeable cold energy in an ice storage system)

  • 이대영;강병하;김민수
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF

Relationship Between Farm Land Structure and Machine Operation in Korea

  • Singh, Gajendra;Ahn, Duck-Hyun
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.129-138
    • /
    • 1993
  • The shortage of agricultural labour due to industrial growth has greatly induced the mechanization in Korean agriculture. However small and scattered land holdings have been the main constraints in the process of mechanization. This paper describes the interrelationships of farm land structure, machinery selection and machinery operation areas. The sandy silt loam irrigated paddy land having single crop a year was selected as a target areas for this study. Machine operation cost is greatly influenced by operation period, plot geometry and operation area. On the improved geometry plots, optimal machine size increases slowly with increase in operation area. Operable area increases due to increased effective machine capacity on better geometry plot. The difference between the effects of operation period and plot geometry is that in the former case, the cost reduction is caused by delay in increase of machine size, whereas in the latter case timeliness cost is reduced by increase ffective capacity. The effect of farmland consolidation is greater on small plots than that on big plots. Increasing wage rates have induced the adoption of more labor saving machinery. Bigger labor saving machines require enlargement of operation area and larger plots through improvement in farm land structure. Machine cost on poor plot geometry increases more rapidly than that on the good plot geometry and as operation area increases machine cost reduces significantly. It is concluded that the development of agricultural mechanization ion Korea will depend on the improvement in farm land structure and enlargement of operation area.

  • PDF

현장에 타설된 연직배수재의 통수능력 분석 (Analysis on the Discharge Capacity of Vertical Drains Installed in the Field)

  • 박영목;진규남;정하익;정길수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.512-519
    • /
    • 2000
  • The discharge capacity of vertical drains installed in the field is reduced with time elapsed after installation due to deformation of drains and clogging effect. Discharge capacity of two types of vertical drains was analysed about three years after installation in the subsoil. Discharge capacity of two types of vertical drains were measured by small, middle, and large scale test apparatus. The results indicate that the discharge capacity of vertical drains after three years operation dramatically decreased compare to the initial discharge capacity.

  • PDF

픽셀값 모듈러 연산을 이용한 자료은닉 기법 (Data Hiding Using Pixel-Value Modular Operation)

  • 변진용;김평한;이준호;정기현;유기영
    • 한국멀티미디어학회논문지
    • /
    • 제18권4호
    • /
    • pp.483-491
    • /
    • 2015
  • Data hiding is one of protective methods that can authenticate the completeness of digital information and protect intelligent property rights and copyright through secret communications. In this paper, we propose a data hiding method using pixel-value modular operation that has a high capacity while maintaining a good visual quality. The proposed method can embed secret data on the every pixel of a cover image by modular operation. The experiment results demonstrate that the proposed method has a high capacity and good visual quality where the embedding capacity is 91,138 bytes, the PSNR is 47.94dB, and the Q index is 0.968.

장비능력에 의존적인 처리시간을 가진 애로공정의 일정계획 수립(몰드변압기 공장을 중심으로) (Scheduling of the Bottleneck Operation with Capacity-Dependent Processing Time)

  • 서준용;고재문
    • 산업공학
    • /
    • 제14권4호
    • /
    • pp.385-393
    • /
    • 2001
  • In this paper, a scheme of scheduling a bottleneck operation is presented for production planning of make-to-order. We focus on the problem of capacity-dependent processing time in which processing time of the bottleneck operation is not fixed, but varies with job sequence or equipment capacity. For this, a genetic algorithm is applied for job sequencing with an objective function of mean square of weighted deviation. An experimental study is implemented in power transformer plant and results are compared with those of the EDD rule. It shows that the genetic algorithm is relatively good for most cases.

  • PDF

시뮬레이션을 이용한 비행장능력 평가모형에 관한 연구 (A Study on Modelling the Airfield Capacity by using Simulation)

  • 오승학;이상진
    • 한국국방경영분석학회지
    • /
    • 제26권1호
    • /
    • pp.15-33
    • /
    • 2000
  • This paper deals with an estimation method of the airfield capacity for the airlift operation. In the US Air Force, airfield capacities has been estimated using MOG(Maximum -On-the-Ground) concept, which is known to having several weaknesses. Recently, RAND suggests a personal-computer- based model called the Airfield Capacity Estimator(ACE), which is a more advanced and realistic technique compared to the MOG. This paper attempts to modify the ACE appropriate to the Korean airlift operation. While ACE is developed on the basis of strategic mobilization, Korean airlift operation is done on the tactical basis. A designed mdel is tested with simulation technique.

  • PDF

Design of an LCL-Filter for Three-Parallel Operation of Power Converters in Wind Turbines

  • Jeong, Hae-Gwang;Yoon, Dong-Keun;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.437-446
    • /
    • 2013
  • This paper proposes a design scheme for an LCL-filter used for the three-parallel operation of the power converters in high-capacity wind turbines. The designs of the power devices and grid connected filter are difficult due to the high level voltages and currents in huge-capacity wind turbines. To solve these problem, this paper presents three-parallel operation and LCL-filter design techniques optimized by parallel operation. Furthermore, the design of an inverter side inductance of the LCL-filter is discussed in detail considering the switching modulation method. Simulation and experimental results demonstrate the validity of the designed filter and wind turbines.