• Title/Summary/Keyword: Operating unit

Search Result 1,247, Processing Time 0.024 seconds

Reliability analysis of an embedded system with multiple vacations and standby

  • Sharma, Richa;Kaushik, Manju;Kumar, Gireesh
    • International Journal of Reliability and Applications
    • /
    • v.16 no.1
    • /
    • pp.35-53
    • /
    • 2015
  • This investigation deals with reliability and sensitivity analysis of a repairable embedded system with standby wherein repairman takes multiple vacations. The hardware system consists of 'M' operating and 'S' standby components. The repairman can leave for multiple vacations of random length during its idle time. Whenever any operating unit fails, it is immediately replaced by a standby unit if available. Moreover, governing equations of an embedded system are constructed using appropriate birth-death rates. The vacation and repair time of repairman are exponentially distributed. The matrix method is used to find the steady-state probabilities of the number of failed components in the embedded system as well as other performance measures. Reliability indexes are presented. Further, numerical experiments are carried out for various system characteristics to examine the effects of different parameter. Using a special class of neuro-fuzzy systems i.e. Adaptive Network-based Fuzzy Interference Systems (ANFIS), we also approximate various performance measures. Finally, the conclusions and future research directions are provided.

A Study on the Architectural Planning of the Patient's Recovery Unit - Focused on the General Hospital in Germany - (수술환자를 위한 회복유니트의 건축계획에 관한 연구 - 독일의 종합병원을 대상으로 -)

  • 채철균
    • Korean Institute of Interior Design Journal
    • /
    • no.40
    • /
    • pp.109-116
    • /
    • 2003
  • The space planning and interior layout of recovery unit should be determined carefully for patient's nursing and observation which is considered to prevent infection and to cope quickly with emergency situation after surgical operation. Recently, the recovery unit in medical facilities is planned and managed without consideration of operating system, sanitary facilities and prior condition of space. Therefore, there is required to the logical criterion of architectural planning for patient's recovery unit which is concerned about opinion of medical team, anesthetist, sanitarian, architect and patient as a user. As the result, this study would apply to design guideline for the architectural planning of patient's recovery unit.

The design of quantization and inverse quantization unit (Q_IQ unit) module with video encoder (비디오 인코더용 양자화 및 역양자화기(Q_IQ unit) 모듈의 설계)

  • 김은원;조원경
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.11
    • /
    • pp.20-28
    • /
    • 1997
  • In this paper, quantization and inverse quantizatio unit, a sa component of MPEG-2 moving picture compression system, ar edesigned. In the processing of quantization, this design adopted newly designed arithmetic units in which quantization matrices and scale code was expressed with SD(signed-digit) code. In the arithmetic unit of inverse quantization, quantization scale code, which has 5-bits length, is splited into two pieces; 2-bits for control code, 3-bits for quantization data, and the method to devise quantization step size is proposed. The design was coded with VHDL and synthesis results in that it consumed about 6,110 gates, and operating speed is 52MHz.

  • PDF

PERIODIC SAFETY REVIEW ON KORI UNIT 1 (고리 1호기 주기적안전성 평가)

  • Kim, Tae-Ryong
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.403-414
    • /
    • 2003
  • Periodic safety review on Kori Unit 1 has been successfully done for the first time in Korea. 11 safety factors of the review were fully evaluated in accordance with the domestic legal system. Although it is the oldest nuclear power plant in Korea, Kori Unit 1 was found to have maintained good operating conditions and continuously enhanced its safety by implementing post-TMI action plans and other safety issues, such as replacing steam generators and process/control system. It can be therefore confirmed that safe operation of Kori Unit 1 is guaranteed until next periodic safety review. Nevertheless, some corrective action items were recommended to enhance further its safety level, such as equipment qualification, additional ageing management program, strengthening of some procedures related to administration and human factor. The results of PSR can be utilized for the continued operation beyond the design life as long as the plant safety is maintained and improved. Experiences of the PSR on Kori Unit 1 can be also applied to PSR on other plants.

  • PDF

A Study on Direct Load Control including Unit Commitment (DLC와 기동정지계획의 연계방법에 관한 연구)

  • Lee, Buhm;Kim, Yong-Ha;Choi, Sang-Kyu;Kim, Hyung-Jung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.713-716
    • /
    • 2001
  • This paper describes Direct load control(DLC) method including unit commitment. To consider the unit commitment on DLC, 3-Dimensional dynamic programming as a new unit commitment method is developed. And, this method is applied to DLC. As result, optimization of operating schedule with DLC is possible. This method is applied to the test system, and usefulness of the method is verified.

  • PDF

The Development of Swivel Unit for Spot Welding Robots (스폿용접 로봇용 스위블 유닛의 개발)

  • Kim, Yong-Seok;Park, Sung-Ho;Yang, Soon-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.119-125
    • /
    • 2008
  • A new type of swivel unit is suggested in order to complement weak points of the existing. This new type of Swivel unit is developed by adopting a spring type cable which has elasticity and restoring force. To minimize the troubles in the process of manufacturing during operating the new type system, strength analysis and the check of interference between parts are accomplished with CATIA. The check of rotating performance is also carried out to determine the diameter and length of spring type cable by SimDesigner motion analysis. Swivel unit used in the robot spot welding is developed with spring type cable and its usefulness in the industrial field is verified through experiments. This system has been registered for patent.

Damping Patch Placement on Outdoor Unit of Air-conditioner by Using Structural Intensity Technique (구조 인텐서티법을 이용한 에어컨 실외기의 제진재 적용)

  • 김규식;진심원;정인화;이정우;강연준
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.577-585
    • /
    • 2004
  • In this paper, reactive shearing structural intensity method is extended to damping patches placement on outer panels of outdoor unit of air-conditioner to reduce its structural borne noise. The structural intensity is calculated from the normal velocities of structures that are measured by using a laser scanning vibrometer, and $textsc{k}$-space (wave-number domain) signal processing is used to obtain the spatial derivatives in formulation of structural intensity. This method is applied to the outdoor unit of air-conditioner on shaker-exciting mode and operating mode. and then damping patches are placed over area of high reactive shearing structural intensity for reducing the radiated noise. Experimental results show the largest reduction of sound pressure level of an outdoor unit by appling small damping patches to optimal position.

A Study on the Performance Improvement of a Simultaneous Heating and Cooling Water Source Heat Pump System by Controlling of the Refrigerant Flow Rate in an Outdoor Unit (수열원 냉난방 동시형 히트펌프 시스템의 실외 열교환기 유량제어를 통한 성능개선에 관한 연구)

  • Bae, Heung Hee;Lee, Dong Hyuk;Lee, Sanghun;Kim, Byengsoon;Ahn, Young Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.131-136
    • /
    • 2013
  • The present study has conducted cycle design and control technology of a water source VRF heat pump system. Previously, study of a simultaneous heating and cooling in an air source VRF heat pump system has been conducted. However, performance data and design methods for simultaneous heating and cooling in a water source VRF heat pump system are limited in the literature, due to various system parameters and operating conditions. In this study, the operating characteristics and performances of a simultaneous heating and cooling heat pump system are carried out, in simultaneous operation modes. Control logics of an EEV are developed for flow rate control to the outdoor unit, and are verified. When the control logics are applied, the simultaneous cooling and heating performances are sufficiently achieved, and system COPs are increased by up to 23.4%.

The Design of an Automatic System for Dairy Cattle Breeding I - The Choice of Temperature Sensor for Body Temperature Measuring - (낙농의 자동화 시스템 구성 I - 체온 감지 온도센서의 선정 -)

  • 김형주;정길도;한병성;김용준;김동원;김명순
    • Journal of Biosystems Engineering
    • /
    • v.23 no.1
    • /
    • pp.83-90
    • /
    • 1998
  • In this paper the automatic system for dairy cattle has been desisted such as body temperature measuring unit, feed supplying unit and temperature control unit. Since e disease is strongly related to the body temperature of cattle, early detection of the abnormal temperature would prevent the severe problems which nay occur in dairy farms. An electronic component AD590J is used as temperature sensor for the system, The device is highly robust against the noise since the output signal is the current so it can be applied to a long distance sensing The resolution of signal is 0.1$^{\circ}C$ and the current is 10㎷ Also 12-bit A/D converter is desisted fir interfacing the sensor with a one-chip microprocessor. A temperature measuring experiment using the developed system has been done for measuring the temperature of human beings and the system was proven to be useful for measuring the body temperature of dairy cattle properly. A geared AC motor is used for the feed supplying unit The heater and fm are used as temperature control unit. The feed supplying unit and temperature control unit are well operating in the laboratory experiment.

  • PDF

Open-Phase Condition Detecting System for Transformer Connected Power Line in Nuclear Power Plant (원자력발전소 변압기 연결 선로 결상 검출 시스템)

  • Ha, Che-Wung;Lee, Do-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.254-259
    • /
    • 2015
  • On January 30, 2012 an auxiliary component of Byron Unit 2 was tripped on bus under voltage. The cause of the event was the failure of the C-phase insulator track for the Unit 2 station auxiliary transformer(SAT) revenue metering transformer. In addition to this event, other events have occurred at other plants resulting in an open-phase condition.[1] Therefore, Nuclear Regulatory Commission(NRC) has requested that not only nuclear power plant(NPP) operating company but also its Design Certification(DC) applicant have to prepare open-phase detecting system in their operating plants and design document. In this paper, various open-phase conditions are simulated in NPP using Electromagnetic Transient Program(EMTP) and Atpdraw, and open-phase condition detecting system is proposed for Main Transformer(MT), Unit Auxiliary Transformer(UAT) and SAT connected power line in NPP.