• Title/Summary/Keyword: Operating time

Search Result 5,664, Processing Time 0.037 seconds

Characteristics of Nitrogen and Phosphorus Removal According to the Variation of Operating Cycles in (AO)2 SBBR ((AO)2 SBBR에서 운전주기에 따른 질소와 인 제거 특성 비교)

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.45-53
    • /
    • 2007
  • This study was carried out to investigate the variation of organic, nitrogen and phosphorus in $(AO)_2$ SBBR process according to the variation of operating cycle at the high TOC concentration. The operation time in anoxic (anaerobic) time to oxic time was 1:1. Three lab-scale SBBRS were fed with synthetic wastewater based on glucose as carbon source, The variation of total TOC removal was similar each other irrespective of operation time, however, the TOC concentrations in SBBRs showed a little difference according to the operating condition. In SBBR, complete nitrification was not occurred at all reactors, however, R3 showed a higher nitrification than R2. And in SBBR, the variation of operating time more affected at phosphorus removal than nitrogen removal. R2 which had the shortest time at the 1st aeration time showed the lowest phosphorus release and uptake efficacy.

HEART: A Highly Customizable Real-Time Operating System for Diverse Embedded Systems (HEART: 다양한 종류의 내장형 시스템들을 위한 맞춤형 실시간 운영체제)

  • Park, Ji-Yong;Hong, Seong-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.717-718
    • /
    • 2006
  • In this paper, we present an RTOS named HEART (Highly Expandable AOP-based Real-Time operating system). It is modularized into a single base and multiple optional features. The base implements a core functionality and each feature implements a specific functionality of RTOS such as interrupt nesting, multithreading, inter-thread communication, and etc. Users can customize HEART just by selecting needed features. Then a specialized version of HEART is automatically generated. We argue that HEART enables the rapid construction of optimized and application-specific RTOSes for diverse embedded systems.

  • PDF

Dynamic Routing and Scheduling of Multiple AGV System (다중 무인운반차량 시스템에서의 동적 라우팅과 스케줄링)

  • 전동훈
    • Journal of the Korea Society for Simulation
    • /
    • v.8 no.3
    • /
    • pp.67-76
    • /
    • 1999
  • The study of the optimization of operating policy of AGV system, which is used in many factory automation environments has been proceeded by many researchers. The major operating policy of AGV system consists of routing and scheduling policy. AGV routing is composed with collision avoidance and minimal cost path find algorithm. To allocate jobs to the AGV system, AGV scheduling has to include AGV selection rules, parking rules, and recharging rules. Also in these rules, the key time parameters such as processing time of the device, loading/unloading time and charging time should be considered. In this research, we compare and analyze several operating policies of multiple loop-multiple AGV system by making a computer model and simulating it to present an appropriate operating policy.

  • PDF

A Study on the Operating Characteristics of the Aged ELCB according to the Overcurrent (노후화된 누전차단기의 과전류 동작 특성에 관한 연구)

  • Ye Jin Park;Sin Dong Kang;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.5
    • /
    • pp.1-7
    • /
    • 2023
  • This study analyzes the operational characteristics of 311 aged and non-aged residual current circuit breakers (RCCBs) in low-voltage consumer contexts. It investigates the influence of external temperature and harmonics based on the rated current multiples. To simulate temperature variations, a convectional oven was used around the circuit breakers. Additionally, the generation of harmonic reference signals and data measurement for overcurrent experiments were conducted using NI SCXI, myDAQ, and LabVIEW. An observation revealed that as the ambient temperature increased, the operating time of RCCBs decreased in the time delay region. This was attributed to the faster response or bending of the bimetal, which is the tripping element. However, aged RCCBs encountered challenges with tripping outside the protective curve. The operating time of the circuit breakers exhibited an acceleration influenced by the order and content of harmonic currents, potentially leading to malfunctions. Aged RCCBs demonstrated faster operating times than their non-aged counterparts. However, the difference in operating time varied based on the manufacturer's and operating environment of the RCCBs. Frequent malfunctions of RCCBs can result in power outages. In cases where these circuit breakers fail to operate, they can lead to secondary damages, including electrical fires and shocks. Consequently, it is imperative to consider the operating environment of RCCBs and provide appropriate replacement cycles to mitigate these risks.

Study on the Asymmetrical Fault Currents and the Operating Time Characteristics of OCR (비대칭과도 전류와 과전류계전기의 동작시간 특성에 관한 연구)

  • 김남호;김일남;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.9
    • /
    • pp.953-959
    • /
    • 1992
  • As the TC(time-current) curve corresponding to symmetrical time invariant RMS value has been traditionally chosen and used for setting the relay, it has caused the misoperation errors on relay coordination because of CT secondary current being actually an asymmetrical time varying RMS value. In this paper, an algorithm for calculating the relay operating time is developed to study the asymmetrical effect using the step-by-step method. We represent the relay operating time errors between with and without DC offset versus PSM(plug setting multiplier), TMS(time multiplier setting) and X/R ratio. And also we present the correction factor. Finally we confirm the validity of this technique through the case study.

An implementation and performance analysis for robot control software under real-time operating systems (실시간 운영체제를 이용한 로봇제어기 소프트웨어의 구현 및 성능 분석)

  • 손승우;이기동
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.375-378
    • /
    • 1996
  • Robot control software is a hard real-time system that must output the planned trajectory points within an explicit short time period. In this paper, we present a design and implementation method for robot control software using commercial real-time operating systems, RTKemel 4.5. Therefore, various robot motions, efficient user interface, and system failure check are easily implemented by using multitasking function, intertask communication mechanism, and real-time runtime libraries of RTKernel. The performance analysis of commercial real-time operating system for robot control is presented based on Timed Petri net(TPN) and we can use these results to design an optimal system.

  • PDF

The Relationship between the Fashion Industry and Macro Variables - Focus on Fashion Listed Company - (패션산업과 거시 변수들간의 관계 -패션 상장기업 중심으로-)

  • Kwon, Ki Yong;Choo, Ho Jung
    • Fashion & Textile Research Journal
    • /
    • v.22 no.1
    • /
    • pp.38-54
    • /
    • 2020
  • This study examines the time causal relationship between the operation profit of the listed fashion companies and the macro variables. Operating profit data of 36 listed fashion companies from 2000 to 2017 has been used. Macro variables include household income, household expenditure, number of Korean overseas travelers, number of foreigner travelers and sentiment index. The study results are as follows. First, the number of outbound travelers from Korea has a negative effect on the operating profit of listed fashion companies; however the number of foreigner visiting Korea has a positive effect at 0 time lag. Second, the consumer sentiment index had a positive effect on the sales and the operating profits of the listed fashion companies with a time difference between the 3rd and the 4th quarter. Third, a disposable income has a positive effect on the operating profit of listed fashion companies. Last, educational expenses have a negative effect on operating profit with a time lag between the first and the second quarter. The findings can be used as useful information to analyze the fashion industry and help fashion companies improve their financial performances.

Current Differential Relaying Algorithm for Power Transformer Protection Operating in Conjunction with a CT Compensating Algorithm (보상 알고리즘을 적용한 변압기 보호용 전류차동 계전방식)

  • Kang, Yang-Cheol;Park, Jong-Min;Lee, Mi-Sun;Jang, Sung-Il;Kim, Yong-Gyun;So, Soon-Hong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1873-1878
    • /
    • 2007
  • Current differential relays may maloperate during magnetic inrush and over-excitation because a significant differential current is produced. To prevent maloperation, the relays adopt some harmonic components included in the differential current. The harmonic restraints may increase the security of a relay but cause the operating time delay of a relay when an internal fault occurs. Moreover, the operating time delay is more increased if a current transformer (CT) is saturated. This paper describes a current differential relaying algorithm for power transformer protection with a compensating algorithm for the secondary current of a CT. The comparative study was conducted with and without the compensating algorithm. The performance of the proposed algorithm was investigated when the measurement CT (C400) and the protection CT (C400) are used. The proposed algorithm can compensate the distorted current of a CT and thus reduce the operating time delay of the relay significantly for an internal fault with CT saturation.

Safety Evaluation on Real Time Operating Systems for Safety-Critical Systems (안전필수(Safety-Critical) 시스템의 실시간 운영체제에 대한 안전성 평가)

  • Kang, Young-Doo;Chong, Kil-To
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3885-3892
    • /
    • 2010
  • Safety-Critical systems, such as Plant Protection Systems in nuclear power plant, plays a key role that the facilities can be operated without undue risk to the health and safety of public and environment, and those systems shall be designed, fabricated, installed, and tested to quality standards commensurate with the importance of the functions to be performed. Computer-based Instrumentation and Control Systems to perform the safety-critical function have Real Time Operating Systems to control and monitoring the sub-system and executing the application software. The safety-critical Real Time Operating Systems shall be designed, analyzed, tested and evaluated to have capability to maintain a high integrity and quality. However, local nuclear power plants have applied the real time operating systems on safety critical systems through Commercial Grade Item Dedication method, and this is the reason of lack of detailed methodology on assessing the safety of real time operating systems, expecially to the new developed one. This paper presents the methodology and experiences of safety evaluation on safety-critical Real Time Operating Systems based upon design requirements. This paper may useful to develop and evaluate the safety-critical Real Time Operating Systems in other industry to ensure the safety of public and environment.

Recovery of ammonium lactates from simulated fermentation broth by desalting electrodialysis (탈염전기투석에 의한 모사발효액으로부터의 암모늄 락테이트의 회수)

  • Han Taehee;Kim Hyun Han;Chang Yong Keun
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.11a
    • /
    • pp.263-266
    • /
    • 2004
  • An experimental study was carried out on the recovery of ammonium lactate from simulated fermentation brothby desalting electrodialysis (DSED). All experiments, using AM-1 and CM-1 membranes, were operated in a constant current and a subsequent constant-voltage mode, and the switching point was determined based on the previous results. The effects of operating conditions such as operating current, initial feed concentration, and initial feed pH were investigated. Increased operating current resulted in a decreased operating time but an increased energy consumption per unit amount of ammonium lactate recovered. As the initial feed concentration was increased, the operating time increased while energy consumption decreased. The operating time and energy consumption slightly decreased as the initial feed pH was increased up to 6.0. However, no significant influences on the recovery of ammonium lactate were observed over 6.0. The rejections of acetate, glucose, and proteins were $10\%,\;93\%,\;and\;98\%$, respectively. Sulfate was not rejected at all.

  • PDF