• Title/Summary/Keyword: Operating temperature range

Search Result 552, Processing Time 0.024 seconds

Feasibility study on the application of membrane distillation process to treat high strength wastewater (막 증발법(Membrane Distillation)을 이용한 고농도 하·폐수처리 가능성 연구)

  • Kim, Se-Woon;Lee, Dong-Woo;Min, Kyung-Jin;Cho, Jinwoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.261-269
    • /
    • 2015
  • In this study, we applied a membrane distillation process to investigate a feasibility of treating a wastewater with high concentration of organic matters including nitrogen and phosphorus. The laboratory scale experiment was performed by using a hydrophobic PVDF membrane with the pore size of $0.22{\mu}m$ and porosity of 75%. The installation was direct contact type where the temperature difference between a feed and permeate side was controlled to have a range from 20 to $60^{\circ}C$. We observed a flux variation and a concentration changes of COD, $PO{_4}^{3-}$-P, $NH_4{^+}$-N and conductivity of feed side as well as permeate side with various temperature differences (20 to $60^{\circ}C$), cross flow velocities (0.09 to 0.27 m/s) through the module, and pH (6.6 to 12.0) of the feed that has the initial concentration of COD about 1,000 mg/L, total nitrogen 390 mg/L, total phosphorus 10 mg/L, conductivity of $7,000{\mu}s/cm$. The results showed that the average flux was ranged from 4 to $40L/m^2/hr$ which was almost similar with the flux of NaCl and deionized water used as a feed solution. The lowest flux was obtained at the operating condition with the temperature difference of $20^{\circ}C$ and cross flow velocity of 0.09 m/s while the highest one was measured with $60^{\circ}C$ and 0.27 m/s. Above 99% of COD and $PO{_4}^{3-}$-P in the feed could be rejected regardless of an operating condition. However, the removal rate of ammonium nitrogen was varied from 64 to 99% depending on the pH of feed solution.

Reaction characteristics of hydrocarbon fuels under various operation conditions of hydro-upgrading process for vegetable oil-based bio-jet fuel production (식물성 오일 기반 바이오항공유 제조공정에서 수소첨가 업그레이딩을 위한 운전조건에 따른 탄화수소화합물의 특성)

  • Kwak, Yeonsu;Jang, Jung Hee;Kim, Sungtak;Ahn, Minhwei;Lee, Eun-Sil;Han, Gi Bo;Jeong, Byung Hun;Han, Jeong Sik;Jeon, Cheol-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.731-743
    • /
    • 2018
  • In bio-jet fuel production, selecting operating conditions of hydro-upgrading is of great importance to make iso-Paraffin rich hydrocarbons with carbon distribution including jet fuel range. Herein, iso-Paraffin rich biofuel including jet fuel range hydrocarbons ($C_8-C_{16}$) is produced from simultaneous cracking and isomerization using n-Paraffin rich hydrocarbon derived from hydrotreated vegetable oil over 0.5 wt..% Pt/Zeolite catalyst. We report and analyze the yields and compositions in the produced hydrocarbons affected by various operating conditions, such as reaction temperature, reaction pressure, molar ratio of reactants, and weight hourly space velocity. Aforementioned operating conditions not only can help interpret the reaction dynamics of hydro-upgrading, but also further produce bio jet-fuel after distillation.

Characteristics of Microwave Air Plasma With a Wide Range of Operating Pressures (운전압력 변화에 따른 마이크로파 공기 플라즈마의 특성연구)

  • 조정현;장봉철;박봉경;김윤환;정용호;김곤호
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.1
    • /
    • pp.68-75
    • /
    • 2002
  • It is observed the characteristic of the microwave air plasma in the wide range of the operating pressure, 1 mTorr ~ 760 Torr. The microwave air plasma was generated by an AC-type microwave source manufactured with a magnetron taken from a commertial microwave oven and the input power was fixed at 370 W. Characteristics of the plasmas were observed by an injection Langmuir probe and an OES(Optical Emission Spectroscopy). The breakdown electric field is drastically changed at 500 mTorr. For < 500 mTorr, the ratio of the breakdown electric field and the pressure decreased inversely to the pressure, $5.7\times10^4$V/m-Torr.However, the ratio increased linearly as 43 V/m-Torr for the operating pressure, > 500 mTorr. The minimum breakdown electric field was observed about 12. kV/m at 500 mTorr. It corresponds that the input frequency equals to the collision frequency. The effective collision cross section of the air at this pressure was calculated as $9.23\times10^{-l6}\textrm{cm}^2$.The results of the OES measurement revealed that the main ions were composed of the oxygen, argon, and nitrogen for > 500 mTorr. In contrast, only oxygen and argon ions were dominated for < 500 mTorr. ion temperature of oxygen (O(II)) in the air was decreased from about 1.2 eV to 0.5 eV as the pressure increased. Langmuir probe data shows that the plasma density for < 500 mTorr was higher that for > 500 mTorr.

Mechanical Properties and Creep Behaviors of Zr-Sn-Fe-Cr and Zr-Nb-Sn-Fe Alloy Cladding Tubes (Zr-Sn-Fe-Cr 및 Zr-Nb-Sn-Fe 합금 피복관의 기계적 특성 및 Creep 거동)

  • Lee, Sang-Yong;Ko, San;Choi, Young-Chul;Kim, Kyu-Tae;Choi, Jae-Ha;Hong, Sun-Ig
    • Korean Journal of Materials Research
    • /
    • v.18 no.6
    • /
    • pp.326-333
    • /
    • 2008
  • Since the 1990s, the second generation of Zirconium alloys containing main alloy compositions of Nb, Sn and Fe have been used as a replacement of Zircaloy-4 (Zr-Sn-Fe-Cr), a first-generation Zirconium alloy, to meet severe and rigorous reactor operating conditions characterized by high-burn-up, high-power and high-pH operations. In this study, the mechanical properties and creep behaviors of Zr-Sn-Fe-Cr and Zr-Nb-Sn-Fe alloys were investigated in a temperature range of $450{\sim}500^{\circ}C$ and in a stress range of $80{\sim}150\;MPa$. The mechanical testing results indicate that the yield and tensile strengths of the Zr-Nb-Sn-Fe alloy are slightly higher compared to those of Zr-Sn-Fe-Cr. This can be explained by the second phase strengthening of the $\beta$-Nb precipitates. The creep test results indicate that the stress exponent for the steady-state creep rate decreases with the increase in the applied stress. However, the stress exponent of the Zr-Sn-Fe-Cr alloy is lower than that of the Zr-Nb-Sn-Fe alloy in a relatively high stress range, whereas the creep activation energy of the former is slightly higher than that of the latter. This can be explained by the dynamic deformation aging effect caused by the interaction of dislocations with Sn substitutional atoms. A higher Sn content leads to a lower stress exponent value and higher creep activation energy.

BaCeO3-BaZrO3 Solid Solution (BCZY) as a High Performance Electrolyte of Protonic Ceramic Fuel Cells (PCFCs) (BaCeO3-BaZrO3 고용체(BCZY) 기반 프로톤 세라믹 연료전지(PCFC)용 고성능 전해질 개발)

  • An, Hyegsoon;Shin, Dongwook;Choi, Sung Min;Lee, Jong-Ho;Son, Ji-Won;Kim, Byung-Kook;Je, Hae June;Lee, Hae-Weon;Yoon, Kyung Joong
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.4
    • /
    • pp.271-277
    • /
    • 2014
  • To overcome the limitations of the solid oxide fuel cells (SOFCs) due to the high temperature operation, there has been increasing interest in proton conducting fuel cells (PCFCs) for reduction of the operating temperature to the intermediate temperature range. In present work, the perovskite $BaCe_{0.85-x}Zr_xY_{0.15}O_{3-\delta}$ (BCZY, x = 0.1, 0.3, 0.5, and 0.7) were synthesized via solid state reaction (SSR) and adopted as an electrolyte materials for PCFCs. Powder characteristics were examined using X-ray diffraction (XRD), thermogravimetric analysis (TGA) and Brunauer, Emmett and Teller (BET) surface area analysis. Single phase BCZY were obtained in all compositions, and chemical stability was improved with increasing Zr content. Anode-supported cell with $Ni-BaCe_{0.55}Z_{0.3}Y_{0.15}O_{3-\delta}$ (BCZY3) anode, BCZY3 electrolyte and BCZY3-$Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-\delta}$ (BSCF) composite cathode was fabricated and electrochemically characterized. Open-circuit voltage (OCV) was 1.05 V, and peak power density of 370 ($mW/cm^2$) was achieved at $650^{\circ}C$.

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF

Construction of Current Sensor Using Hall Sensor and Magnetic Core for the Electric and Hybrid Vehicle (홀소자와 자기코어를 이용한 하이브리드 및 전기자동차용 전류센서 제작)

  • Yeon, Kyoheum;Kim, Sidong;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.2
    • /
    • pp.49-53
    • /
    • 2013
  • A current sensor is one of important component which is used for the electrical current measurement during charge and discharge of the battery, and monitoring system of the motor controller in the electric and hybrid vehicle. In this study, we have developed an open loop type current sensor using GaAs Hall sensor and magnetic core has an air gap. The Hall sensor detect magnetic field produced by the current to be measured. The 3 mm air gap core was made by HGO electrical steel sheets after slitting, winding, annealing, molding, and cutting. Developed current sensor shows 0.03 % linearity within DC current range from -400 A to +400 A. Operating temperature range was extended to the range of $-40{\sim}105^{\circ}C$ using temperature compensating electronic circuit. To Improve frequency bandwidth limit due to the air flux of PCB (Printed Circuit Board) and Hall sensor, We employed an air flux compensating loop near Hall sensor or on PCB. Frequency bandwidth of the sensor was 100 kHz when we applied sine wave current of $40A{\cdot}turn$ in the frequency range from 100 Hz to 100 kHz. For the dynamic response time measurement, 5 kHz square wave current of $40A{\cdot}turn$ was applied to the sensor. Response time was calculated time reach to 90 % of saturation value and smaller than $2{\mu}s$.

Bioleaching of Heavy Metals from Shooting Range Soil Using a Sulfur-Oxidizing Bacteria Acidithiobacillus thiooxidans (황산화균 Acidithiobacillus thiooxidans를 이용한 사격장 토양 내 중금속 용출)

  • Han, Hyeop-Jo;Lee, Jong-Un;Ko, Myoung-Soo;Choi, Nag-Choul;Kwon, Young-Ho;Kim, Byeong-Kyu;Chon, Hyo-Taek
    • Economic and Environmental Geology
    • /
    • v.42 no.5
    • /
    • pp.457-469
    • /
    • 2009
  • Applicability of bioleaching techniques using a sulfur-oxidizing bacteria, Acidithiobacillus thiooxidans, for remediation of shooting range soil contaminated with toxic heavy metals was investigated. The effects of sulfur concentration, the amount of bacterial inoculum and operation temperature on the efficiency of heavy metal solubilization were examined as well. As sulfur concentration and the amount of bacterial inoculum increased, the solubilization efficiency slightly increased; however, significant decrease of heavy metal extraction was observed with no addition of sulfur or bacterial inoculum. Bacteria solubilized the higher amount of heavy metals at $26^{\circ}C$ than $4^{\circ}C$. Lead showed the highest removal amount from the contaminated soil but the lowest removal efficiency when compared with Zn, Cu and Cr. It was likely due to formation of insoluble $PbSO_{4(s)}$ as precipitate or colloidal suspension. Sequential extraction of the microbially treated soil revealed that the proportion of readily extractable phases of Zn, Cu and Cr increased by bacterial leaching, and thus additional treatment or optimization of operation conditions such as leaching time were required for safe reuse of the soil. Bioleaching appeared to be a useful strategy for remediation of shooting range soil contaminated with heavy metals, and various operating conditions including concentration of sulfur input, inoculum volume of bacteria, and operation temperature exerted significant influence on bioleaching efficiency.

A Study on the Compatibility of Korean Temperature Guidelines for Stockpile Material Environmental Test (저장물자 환경시험을 위한 한국적 온도기준 적합성 연구)

  • Lee, Il Ro;Byun, Kisik;Cho, Sung-Yong;Kim, Kyung Pil;Park, Jae Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.187-194
    • /
    • 2020
  • The T&E (Test and Evaluation) results were applied for a judgment basis to decide the developmental process of system engineering for efficient weapon system R&D (Research and Development). During the OT&E (Operational Test and Evaluation) and DT&E (Development Test and Evaluation), an environmental test is essential for weapon system development owing to their highly exposed operational conditions. Based on the MIL-STD-810, MIL-HDBK-310, and AECTP 200, the ROK armed forces recommended operating temperatures for the ROK weapon system and applied this to the DT&E and OT&E. This study examined the compatibility of Korean temperature guidelines for stockpile material considering recent climate change. Moreover, this study analyzed the data from hourly measured temperatures on 101 observatories during 60 years, from 1960 to 2020, and percentage (0.5%, 1%, 5%, and 10%) and the 𝜎 (3𝜎, 2𝜎, and 1𝜎) frequency of occurrence on rigorous hot (August) and cold (January) periods, respectively. The results indicate that the highest temperature was 41℃, and the 0.5% frequency of occurrence was 37.0℃. In the case of the cold period, the lowest temperature was -32.6℃ and the 0.5% frequency of occurrence was -21.1℃. By considering the previously recommended operating temperature range for a general ground system, -30 ~ 40℃, regional operation probability is recognized 99.999%. Despite the recent abnormal climate change from global warming, the Korean temperature guidelines are compatible with the stockpile material environmental test.

Separation of Chromophoric Substance from Amur Cork Tree Using GC-MS (GC-MS를 이용한 황벽의 색소 성분 분리 거동)

  • Ahn, Cheun-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.6
    • /
    • pp.980-989
    • /
    • 2009
  • Amur cork tree was extracted in methanol with the purpose of investigating the most effective extraction procedure for detecting the chromophore using the GC-MS analysis. Different procedures of waterbath and hotplate extractions were carried out and five different GC-MS instrument parameters including the operating temperatures in the GC capillary column and the MSD scan range were tested for their efficiencies. Berberine was determined by the detection of dihydroberberine at 15.0 min r.t. Hotplate was a better device for extracting amur cork tree than waterbath shaker either with or without presoaking in the room temperature. Water was not an adequate extraction medium for the berberine detection. The most effective GC-MS parameter was Method 4; the initial temperature at $50^{\circ}C$ followed by the temperature increase of $23^{\circ}C$/min until $210^{\circ}C$, then increase of $30^{\circ}C$/min until the final temperature reach at $305^{\circ}C$, then hold for 14 minutes to maintain the total run time 24.12 minutes. The MSD scan range for Method 4 was $35\sim400$m/z.